DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Similar documents
DATA SHEET Panorama Rudder Indicator, TRI-2

02/11/2015

Process transmitter RMA422

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

multi-function meters

Grid feeding monitoring according to VDE-AR-N 4105 and BDEW CM-UFD.M31

CAMTO LTD. Arc detecting system DC/AC

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Process Transmitter RMA 422

SyG 02 and SyG 02-SB

Assembly. Front view. LEDs. Parametrization interface. Power Bus

EA350. Generator Automatic Voltage Regulator Operation Manual

Series CT7N Bimetallic Overload Relays

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

Bulletin 190 IEC Modular Starter System

ABB CM-UFD.M31 monitoring datasheet

BE3-GPR GENERATOR PROTECTIVE RELAY

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

KRF EMC Filters Installation, Operation and Maintenance Manual

REGO Start&Go USER MANUAL

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Standard RS232 RS ma

Gamma instabus. Technical product information

Actuators IC 20, IC 40

ALLEN BRADLEY TIMING RELAY

Linear flow control with actuator IFC

PRINCIPLES AND APPLICATIONS

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Kuhnke Technical Data. Contact Details

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

AS09..S 3-pole Contactors - Spring Terminals

SAUTER flexotron RDT405 Manual

Lt DELTA USA, Inc

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Operating instructions Electronic preset counter Type series 717

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Single Point Flow Monitor SW118 SW119

Multifunction devices

Electronic Pulse Counter Combination device

Minicontactorrelay,2NO/2NC,DCoperated

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

MICROMASTER Encoder Module

51109 Köln St. Asaph, Denbigshire LL17OLJ

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

263 Series LED Bargraph Indicator and Controllers

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LAUREL ELECTRONICS, INC.

Telemetry Receiver Installation Guide

Generator protection relay

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Type: DILM25 10(24V50HZ) Article No.:

Electrical connection

Electrical connection

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Level Measurement silometer FMC 420, FMC 423

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Power Circuit of a UL508A Panel. Typical UL489 Application

Certificate of Calibration

HS-509 VIBRATION TRIP MODULE

Improved Synchronization System for Thermal Power Station

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Linear flow controls VFC Linear flow controls with actuator IFC

MILLITARY SPECIFICATION SHEET

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Preset counters, electronic

Form C: Type Test Verification Report

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

High performance circuit breakers

EMC Solutions Noise filtering

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Arc-fault Protection System

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Selection guide siemens.com/sirius-modular-system

Datasheet - SRB301LC 24VAC/DC

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Magnecraft Power Relays

Ordering details. Approval. Classification

Dimming actuators GDA-4K KNX GDA-8K KNX

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

EG4015. Digital Generator Governor Controller User Manual

INSTALLATION & USER GUIDE

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

Transcription:

DATA SHEET Synchronisers, ANSI code 25 Synchronisation of generator to busbar Circuit breaker time compensation LED indication of status LED for activated control LED for synchronising signal 35 mm DIN rail or base mounting Document no.: 4921240114J

Application The synchroniser is applied for synchronisation of a generator to the busbar and closing of its circuit breaker when the difference, the slip frequency and the phase angles are within the preset limits. The synchroniser can be applied in conjunction with a wide range of prime movers, as its control pulses may be set to fit several types - from slowly reacting diesel engines to swiftly reacting gas turbines. Function The performs a dynamic synchronisation, ensuring that the slip frequency is always positive to prevent the occurrence of reverse power conditions (see option D). In order to calculate when to transmit the closing signal to the generator breaker, the synchroniser measures the actual slip frequency and compares this with the circuit breaker closing time (potentiometer marked BREAKER). When the slip frequency and the deviation are within the settings (potentiometers marked FREQ and VOLTAGE), the above calculation is performed, and the synchroniser transmits the closing signal to the breaker x degrees before top, allowing time for this to close. In case of harmonic distortion or noise on the inputs, the is equipped with special filters on the AC inputs to avoid imprecise synchronisation pulse being transmitted. Furthermore, a df/dt (ROCOF) function is implemented. If the filters are unable to make the necessary filtering of the input signals, the df/dt function will prevent imprecise synchronisation pulse from being transmitted. If the df/dt function is active, the situation will be indicated by a flashing f LED (see option C). The is provided with an analogue frequency output and an analogue output intended for common control of the frequency and the of DEIF load sharing units type LSU-112/113/114DG and LSU-122DG, a function applied for simultaneous synchronisation of all generators of a plant to the busbar. Regulator output The unit is provided with two contact outputs for speed control: T N (pulse length): The min. duration of the control pulse. X P (proportional band): The zone within which the pulse/pause ratio changes proportionally to the frequency deviation from f set. Deadband 0.05 Hz: The zone within which no control pulses are emitted. The phase angle advance is calculated and a synchronising signal transmitted, provided that: 1. the difference is within ±2 to ±12 % of the busbar, and 2. the frequency difference is within ±90 % of the value set on the FREQ potentiometer, and 3. the generator frequency is higher than the busbar frequency (also see option D). When the above three conditions are fulfilled, a synchronising signal is transmitted, the yellow LED SYNC is lit, and the output contact is activated for 400 ms. Special function for commissioning The is equipped with a function for checking of the phase sequence. When the frequency and the between the busbar and the generator inputs are the same, and the phase is inside ±5 for 1 s, the sync. relay is activated. If the generator is stopped and the star point is opened and the generator breaker closed, the will transmit a closing signal if the phase sequence is OK. Self-monitoring The is equipped with a self-monitoring function. The function supervises the built-in microcontroller and hereby verifies if the programme is running correctly. The green LED marked POWER is connected to this function. Constant green light indicates that the supply is accepted and the unit is running correctly. Flashing green light 2-3 Hz indicates that the supply is accepted but the unit is running incorrectly. In this situation, the status output terminals 17 and 18 are activated (open). Frequency control: The regulating speed of the servomotors for the prime mover is controlled by the built-in P controller of the according to its setting for: DEIF A/S Page 2 of 7

Terminals/function Connection Connect Busbar L1 to term. 24 L2 to term. 26 Generator L1 to term. 29 L2 to term. 31 Terminal no. Description/action 1 and 3 Input for supply. X1/X2 8, 9 and 10 Relay contact for circuit breaker. On time 400 ms. 17 and 18 Status output, activated (closed) when the supply is connected and the unit is working correctly. Sta 24 and 26 Input for busbar measurement. This input becomes active when the level exceeds 80 % BB/L1 of nominal. BB/L2 29 and 31 G/L1 G/L2 33 ( U ) Option F 34 and 35 ( INH ) 36 ( f ) 35 ( ) 38 and 39 Relay contacts SG 40 and 41 Relay contacts SG NOTE: Relay contacts Input for generator measurement. When the level on this input exceeds 60 % of nominal, the is activated and the regulator outputs (SG) become active. Note that with an auxiliary contact on the generator circuit breaker this function can be used to reset the after synchronisation and hereby deactivate the SG outputs. This function allows the supply to be connected at any time. This output is intended for common control of the of all the connected reactive power load sharing units type LSU-122DG in a generator island. If terminal 33 is connected to the common line (US) on the LSU-122DGs, the will regulate the on the generator island so it matches the on the unit the island is about to be connected to. May be connected to a potential-free N/O contact. When this contact is activated, the will not transmit a closing signal (terminals 9 and 10), but the SYNC LED will be lit when the sync. pulse is transmitted. This function can be used for testing purposes. Note that if the is equipped with option A or B, this input has a different function. This output is intended for common control of the frequency of all the connected load sharing units type LSU-112/113/114DG in a generator island. If terminal 36 is connected to the common frequency line (FS) on the LSUs, the will control the frequency on the generator island so it matches the frequency on the unit the island is about to be connected to. Common earth terminal for the above input/output. Relay contact for increase of the speed. Relay contact for decrease of the speed. Relays (SG) should always be connected via external aux. relays when a DC pilot motor is applied. A transient suppressor should always be connected across the relay coil of the external relays. DEIF A/S Page 3 of 7

Options The can be configured with the following options: Frequency controller, option A The is set to act as a frequency controller ensuring a stable generator frequency according to the setting (50 Hz or 60 Hz). The function is activated when the INH input is closed. If the INH input is open, the functions as a normal synchroniser. When the input INH is activated, the will act as a frequency controller and regulate the generator to the frequency setting (50 Hz or 60 Hz) ±0.05 Hz and no sync. pulse will be transmitted. It is not possible to have option A and option B at the same time. Dead bus, option B When implemented, the dead bus function enables the to transmit a closing signal to the generator breaker when no busbar is present. When the generator is within 60 % of nominal level and the busbar is below 20 % of nominal level, the will start to control the generator frequency according to the setting (50 Hz or 60 Hz). When the frequency becomes nominal within ±0.05 Hz, ±0.5 Hz or ±3 Hz depending on internal jumper setting, ±0.5 Hz is set as default if no specific request is made, and when the level is nominal ± the setting (potentiometer marked VOLTAGE), the sync. pulse is transmitted to the breaker. Please note that after closing of the breaker ( on both inputs on the ), the input on terminal 29 or 31 or the supply on terminal 1 or 3 must be disconnected, otherwise the will run the generator into overspeed. If the INH input is activated (closed), the will not activate the sync. relay even if there is a dead bus situation. When INH is deactivated, the will transmit the closing signal. It is not possible to have option A and option B at the same time. Accept of both undersynchronisation and oversynchronisation of the generator breaker, option D Option D can be activated in applications where a fast synchronisation has priority and the risk for reverse power is unimportant. With this option activated, the will regulate the generator to perform either an under- or an oversynchronisation. The parameter used for either under- or oversynchronisation is the parameter which first obtains a synchronisation as fast as possible. Extended circuit breaker closing time, option E In applications with very slow generator circuit breakers with closing time up to 400 ms, this option will prolong the setting of the closing time (potentiometer marked BREAKER) to cover the range 200 to 400 ms. Voltage difference analogue output, option F This output is standard 0 to 5 to 10 V corresponding to 80 to 100 to 120 % of U nom for control of the LSU- 122DG. If option F is selected, the output is changed to -10 to 0 to 10 V corresponding to 90 to 100 to 110 % of U nom for control of the units in the Multi-line series, for example PPU/GPC. Deactivation of the df/dt protection function, option C If instability in the speed loop control system occurs, resulting in jitter on the signals (fast instability typically occurs, if the governor is responding to engine firings), and it is not possible to adjust this on the governor, or in applications with much noise and harmonic distortion (frequency converters), the df/dt protection function can be activated resulting in NO sync. pulse. If this is the case, and the switchgear is properly protected against wrong synchronisation, the df/dt protection function can be disabled. Please note that when this function is disabled, noise on the busbar and the generator inputs of the can, at worst, result in a 180 out of phase synchronisation. DEIF A/S Page 4 of 7

Technical specifications Accuracy: Breaker closing: Slip frequency 0.05 to 0.25 Hz: ±3 el. Slip frequency 0.25 to 0.5 Hz: ±5 el. Temperature: -25 to 70 C (-13 to 158 F) (operating) UL/cUL Listed: Max. surrounding air temp. 60 C/140 F Meas. : 57.7-63.5-100-110-127-200-220- 230-240-380-400-415-440-450-480-660-690 V AC UL/cUL Listed: 57.7 to 450 V AC Load: 2 k /V Temperature drift: Galv. separation: Set points: Max. ±0.2 % of full scale per 10 C/50 F Between inputs and outputs: 3250 V - 50 Hz - 1 min. Frequency range: Breaker closing pulse length: Inhibit input: 40 to 45 to 65 to 70 Hz 400 ms ±10 ms Potential-free contact Open: 5 V. Closed: 5 ma UL/cUL Listed: +/-5 V DC (using pot. free ext. contacts) Contact outputs: Sync. pulse output: 1 change-over switch Freq. control outp.: 2 make contacts Contact ratings: AC1/DC1: 250V AC/24V DC, 8 A AC15/DC13: 250V AC/24V DC, 3 A Life electrical: Analogue output: Freq. difference: Volt. difference: UL/cUL Listed: Resistive load only 1 10 5 (nominal value) 1 analogue output: -10 to 0 to 10 V DC ~ -5 to 0 to 5 Hz 1 analogue output: 0 to 5 to 10 V DC ~ 80 to 100 to 120 % of U n -10 to 0 to 10 V DC ~ 90 to 100 to 110 % of U n with option F activated UL/cUL Listed: +/-10 V DC Optocoupler outp.: System status off = Failure Max. 30 V DC, max. current 5 ma Voltage drop 1.5 V ~ 2 ma UL/cUL Listed: 30 V DC, 5 ma Supply (U n ): 57.7-63.5-100-110-127-220-230- 240-380-400-415-440-450-480-660-690 V AC ±20 % (max. 3.5 VA) 24-48-110-220 V DC -25/+30 % (max. 2.5 W) UL/cUL Listed: Only 24 V DC and 110 V AC DC supply must be from a class 2 power source Climate: HSE, to DIN 40040 EMC: To IEC/EN 61000-6-1/2/3/4 Connections: Materials: Protection: Type approval: UL markings: Max. 4.0 mm² (single-stranded) Max. 2.5 mm² (multi-stranded) All plastic parts are selfextinguishing to UL94 (V1) Case: IP40. Terminals: IP20, to IEC 529 and EN 60529 The Uni-line components are approved by the major classification societies. For current approvals see www.deif.com or contact DEIF A/S. UL Listed only on request UL Listing will be lost if the product is re-customised outside DEIF DK's production plant Wiring: Use 60/75 C (140/167 F) copper conductors only Wire size: AWG 12-16 or equivalent Installation: To be installed in accordance with the NEC (US) or the CEC (Canada) DEIF A/S Page 5 of 7

Settings Setting of Range T N Control pulse length 25 to 500 ms X P Proportional band @ 50 Hz ±0.25 to ±2.5 Hz X P Proportional band @ 60 Hz ±0.50 to ±2.5 Hz f set Slip frequency 0.05 to 0.5 Hz * U max. Acceptable volt. diff. ±2 to ±12 % of U BB T BC Breaker closure time 20 to 200 ms (200 to 400 ms) option E * Accept of max. df/dt depends on f set 0.05 Hz ~ 2.5 Hz/sec. 0.5 Hz ~ 12.5 Hz/sec. Indication LEDs U G Generator U BB Busbar f Frequency difference (df/dt check) U Voltage difference SYNC Synchronising SG Increase speed (freq.) SG Decrease speed (freq.) Light Green, when value is within the acceptable range Switched off, if outside this range Yellow, when relay is activated Once the relay has been mounted and adjusted, the transparent front cover may be sealed to prevent unwanted change of the setting. Connections/dimensions (in mm) See installation instructions for information about status output (17-18) Weight: Approx. 0.750 kg DEIF A/S Page 6 of 7

Available variants Item no. Variant no. Variant description 2913010160 01 - DC supply 2913010160 02 - AC supply Variants: Order specifications Mandatory information Item no. Type Variant no. Measuring Supply Generator frequency Additional options to the standard variant Option Example: Mandatory information Item no. Type Variant no. Measuring Supply Generator frequency Additional options to the standard variant Option 2913010160-01 01 380 V AC 24 V DC 50 Hz Option A NOTE: Option A and option B cannot be chosen at the same time. Regarding option B, please remember to indicate the accuracy for the frequency if this differs from ±0.5 Hz. Other settings are ±0.05 Hz or ±3 Hz. DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Due to our continuous development we reserve the right to supply equipment which may vary from the described. Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: deif@deif.com, URL: www.deif.com