Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

Similar documents
Bulletin 100-G IEC Contactors

Bulletin 100-G IEC Contactors

Bulletin 190 Compact. Combination Starters

Bulletin 305 AC Starters

Bulletin 190 IEC Modular Starter System

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

ALLEN BRADLEY TIMING RELAY

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Relays and Timers Quick Selection Table

Series CT7N Bimetallic Overload Relays

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Selection guide siemens.com/sirius-modular-system

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Contactors and Contactor Assemblies

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

llen-bradley 194R-HM4-NFPA3

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

3-pole contactors for standard applications

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

AS09..S 3-pole Contactors - Spring Terminals

Magnecraft Power Relays

Series CDP2 Definite Purpose Contactors

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Series CDP2 Definite Purpose Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Minicontactorrelay,2NO/2NC,DCoperated

AC1036. Definite Purpose Contactors

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

XT IEC Power Control Combination Motor Controllers

Bulletin 150, 154 Softstarters Quick Selection Table

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

High performance circuit breakers

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Bulletin 509 Full Voltage

A V 50Hz / V 60Hz

Features XT SC 012 B B A

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Features XT SC 012 B B A

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Manual Motor Starter Specifcations

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Definite Purpose Contactors

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys circuit-breakers

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

Data Sheet Definite Purpose Contactors Ex9CK Series

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Bulletin 500 Top Wiring For Motor Loads

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME. Main. Device short name. Device application

16 A and 25 A power contactors with or without handle

Datasheet - SRB301LC 24VAC/DC

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Main. Device short name. Device application

.1 Product Overview The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Magnetic and Hydraulic-Magnetic Circuit Breaker

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

relays Electromechanical 2006 /2007

VAT 20 Adjustable Frequency Drive

Power Circuit of a UL508A Panel. Typical UL489 Application

30 mm Push Buttons 9001 K and SK Selector Switches

Ordering details. Approval. Classification

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

30 mm Push Buttons 9001K and SK Selector Switches

Modular pulse operated latching relay 16 A

Transcription:

Bulletin 100-M Miniature Contactors Compact Size Uniform Panel Mounting Dimensions Full oltage Non-Reversing and Reversing Contactors 5, 9, and 12 A Contactors Compatible with Bulletin 193-E solid-state and 193-M bimetal Overload Relays Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories Allen-Bradley miniature contactors are designed for commercial and light industrial applications where panel space is at a premium. These miniature devices, while 45 mm wide, are shallower and have less panel depth requirements than standard IEC contactors. These mini-contactors are designed with flexibility in mind. They are available in several contact ratings, offer 2- and 4-pole adder decks, and a wide variety of contact configurations. Additionally, the contactor is available with both AC or DC operating coils. Standards Compliance and Certifications Standards Compliance EN/IEC 60947 CSA C22.2 No. 14 UL 508 Certifications CE Marked (Per EU Low oltage Directive 73/23/EEC 93/68/EEC) CSA Certified (File No. LR1234) UL Listed (File No. E3125; Guide No. NLDX 2nd NYT)

Product Selection Mini-Contactors Non-Reversing Mini-Contactors 3 N.O. Power Poles/Auxiliary Contact Rated Operation al Current Ratings for switching AC motors 3 AC-3 kw Hp (60 Hz) Ratings (50 Hz) AC- AC- 230 400/415 500 1 3 3 1 115 230 200 5.3 20 1.5 2.2 2.2 1/2 1 1-1/2 9 20 3 4 4 1/2 1-1/2 230 1-1/2 460 575 3 3 2 2 5 5 12 20 3 5.5 4 1/2 2 3 3 7-1/2 10 Auxiliary Contact Configuratio n Pkg. Qty. Cat. No. N.O. N.C. 1 0 10 100-M05N 3 0 1 10 100- M05N 31 1 0 10 100-M09N 3 0 1 10 100- M09N 31 1 0 10 100-M12N 3 0 1 10 100- M12N 31 Contactors may be ordered in quantities of 1. Add the letter S to the end of the cat. no. (Example: 100-M09ND3S). Reversing Mini-Contactors 3 N.O. Power Poles/Auxiliary Contact Rated Ratings for switching AC motors Operationa l Current 3 AC-3 kw Hp (60 Hz) Ratings (50 Hz) AC-3 AC-1 230 400/415 500 1 3 115 230 200 230 460 575 5.3 20 1.5 2.2 2.2 1/2 1 1-1/2 1-1/23 3 9 20 3 4 4 1/2 1-1/2 2 2 5 5 12 20 3 5.5 4 1/2 2 3 3 7-1/2 10 Auxiliary Pkg Cat. No. Contact. Configuratio Qty n. N.O. N.C. 1 0 1 104-M05N 3 0 1 1 104- M05N 31 1 0 1 104-M09N 3 0 1 1 104- M09N 31 1 0 1 104-M12N 3 0 1 1 104- M12N 31 Preferred value according to IEC 60072-1. Contactors may be ordered in quantities of 1. Add the letter S to the end of the cat. no. (Example: 100-M09ND3S).

Not available with DC coil. Coil oltage Code The cat. no. as listed is incomplete. Select a Coil oltage Code from the table below to complete the cat. no. Example: Cat. No. 100-M05N 3 becomes Cat. No. 100-M05NKD3. For other voltages, consult your local Allen-Bradley distributor. oltage 24 48 110 110 120 220 230 230 240 380 50 Hz KD KH D A KK 60 Hz KD KH D A KK DC Z24 DC with integrated diode ZD24 Contactors may be ordered in quantities of 1. Add the letter S to the end of the cat. no. (Example: 100-M09ND3S). Not available with DC coil. Bulletin 100-M/104-M Accessories Cat. No. 195-MB22 Description Type For Use Cat. No. With Auxiliary 2 N.C. 100/104-195-MB02 Contact 2 N.O. M05 M12 195-MA20 Adder Deck 1 N.O./1 N.C. 195-MB11 Top mounted 4 N.O. 195-MA40 2 N.O./2 N.C. 195-MB22 Solid-State 0.3 3 s On- 100-M 196-MT3S Timing Delay, 110 250 Element AC or DC 1 30 s On-Delay, 196-MT30S 110 250 AC or DC Star-Delta 110 AC 196-MTSDA1 Timer 220 AC 196-MTSDA2 48 196-MTSDA3 35 mm DIN Rail Mounting Adapter for Above 196-MTM Timers Mechanical Mechanical 100-199-MXM1 Interlock Kit Interlock Only M05 M12 (AC Coils Only) Power Wiring Kit For Reversing Contactors 100- M05 M12 140-KCR4 R-C 24 48 AC 100/104-199-MSMA48 Suppressor 110 280 AC M05 M12 199-MSMA1 MO Suppressor 12 55 AC/12 77 DC 199-MSM1

Diode Suppressor R-C Suppressor MO Suppressor Diode Suppressor 56 136 AC/78 162 DC 137 277 AC/163 350 DC 12 250 DC 199-MSM2 199-MSM3 199-MSMD1 24 48 AC 100M 199-MSMNA48 110 280 AC 199- MSMNA280 380 480 AC 199- MSMNA480 12 55 199-MSM4 AC/12 77 DC 56 136 199-MSM5 AC/78 162 DC 137 277 199-MSM6 AC/181 350 DC 12 250 DC 199-MSMD2 PQ = Package Quantity Discount Group PRO Must be ordered in multiples of 10. Sold in quantities of 1. Not for use with direct-mounted overload relays. Bulletin 100-M Miniature Contactors Labelling Material Description Pkg. Qty.Cat. No. Labels 10 199-ID1 Adhesive Paper 105 per sheet Marking Tags 10 199-ID2 160 per sheet Cover 100 199-ID3 Transparent/Tag Tag Carrier 100 199-ID4 For Clip-On Tags Bulletin 100-M/104-M Life-Load Curves Electrical life; U e = 400 460 AC AC-3 Switching of squirrel-cage motors while starting AC-1

Non- or slightly inductive loads, resistance furnaces Electrical life; U e = 400 460 AC AC-4 Stepping of squirrel-cage motors

Bulletin 100-M/104-M Approximate Dimensions Bulletin 100-M Miniature Contactors and Accessories Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Mini-Contactor or Mini-Relay With Auxiliary ContactAdder Deck or Timer Mounted to Front.Cat. No. 100-M or 700-M Mini-Contactor or Mini-Relay With SurgeSuppressor Mounted to Front.Cat. No. 100-M or 700- M

Mini-Contactor or Mini-Relay With Auxiliary Contact Adder DeckMounted to Front and Timer Mounted to SideCat. No. 100-M or 700-M Surge SuppressorCat. No. 199-MSM Reversing Mini-Contactors With Auxiliary Contact Adder DeckCat. No. 104-M Timer With DIN Rail Mounting Adapter on 35 mm DIN RailCat. No. 196-MT Timer With DIN Rail Mounting Adapter on 35 mm DIN RailCat. No. 196-MT Mounting Position

Renewal Parts Bulletin 100-M Replacement Coils AC and DC coils are not interchangeable. Bulletin 100-C Replacement Coils Description Pkg. Qty. Cat. No. 24 50/60 Hz 10 MA014 48 50/60 Hz 10 MA024 110 50 Hz/110 120 60 Hz 10 MA034 220 50/60 Hz 10 MA050 240 50/60 Hz 10 MA052 380 50/60 Hz 10 MA062 440 50 Hz/480 60 Hz 10 MA082 12 DC 10 MB708 18 DC 10 MB710 24 DC 10 MB714 48 DC 10 MB724 60 DC 10 MB734 110 DC 10 MB744 125 DC 10 MB746 220 DC 10 MB766 24 DC with Diode Suppressor10 MD714 AC Standard Control oltages AC [] Coil Code 50 Hz 60 Hz 50/60 Hz 100- C09 100- C16 100-C23 100-100- C37, 100L-C20 C40, - C43 100- C60 100- C85 100- C90 Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 12 Q TA006 TC006 TD006 TE006 TF006 12 R TA404 TC404 TD404 TE404 TF404 24 J TA013 TC013 TD013 TE013 TF013 24 K TA407 TC407 TD407 TE407 TF407 24 KJ TA855 TC855 TD855 TE855 TF855 32 36 TA481 TC481 TD481 TE481 TF481 36 W TA410 TC410 TD410 TE410 TF410 42 48 X TA482 TC482 TD482 TE482 TF482 48 Y TA414 TC414 TD414 TE414 TF414 48 KY TA860 TC860 TD860 TE860 TF860 100 100 110 100 KP TA861 TC861 TD861 TE861 TF861 110 120 D TA473 TC473 TD473 TE473 TF473 110 KD TA856 TC856 TD856 TE856 TF856 120 P TA425 TC425 TD425 TE425 TF425

127 S TA428 TC428 TD428 TE428 TF428 200 200 220 200 KG TA862 TC862 TD862 TE862 TF862 208 H TA049 TC049 TD049 TE049 TF049 200 220 208 240 L TA296 TC296 TD296 TE296 TF296 200 230 KL TA864 TC864 TD864 TE864 220 240 A TA474 TC474 TD474 TE474 TF474 220 230 260 F TA441 TC441 TD441 TE441 TF441 230 KF TA851 TC851 TD851 TE851 TF851 230 240 A TA440 TC440 TD440 TE440 TF440 240 277 T TA480 TC480 TD480 TE480 TF480 240 KA TA858 TC858 TD858 TE858 TF858 347 I TA065 TC065 TD065 TE065 TF065 380 E TA067 TC067 TD067 TE067 TF067 380 400 440 N TA071 TC071 TD071 TE071 TF071 400 KN TA863 TC863 TD863 TE863 TF863 400 415 G TA457 TC457 TD457 TE457 TF457 440 480 B TA475 TC475 TD475 TE475 TF475 440 KB TA859 TC859 TD859 TE859 TF859 500 M TA479 TC479 TD479 TE479 TF479 550 600 C TA476 TC476 TD476 TE476 TF476 Coils, Continued DC Standard Control oltage [] DC Coil Code 100- C09 100- C16 100-C23 100- C37, 100L-C20 100-C40, - C43 100- C60 100- C85 100-C90 Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 9 ZR TA766 TC766 TD766 9 Diode DR TE766M TF766M 12 ZQ TA708 TC708 TD708 12 Diode DQ TE708M TF708M 24 ZJ TA714 TC714 TD714 24 Diode DJ TA714M TC714M TD714M TE714M TF714M 36 ZW TA719 TC719 TD719 36 Diode DW TE719M TF719M 48 ZY TA724 TC724 TD724 48 Diode DY TE724M TF724M 60 ZZ TA774 TC774 TD774 60 Diode DZ TE774M TF774M 64 ZB TA727 TC727 TD727 64 Diode DB TE727M TF727M 72 ZG TA728 TC728 TD728 72 Diode DG TE728M TF728M 80 ZE TA729 TC729 TD729

80 Diode DE TE729M TF729M 110 ZD TA733 TC733 TD733 110 Diode DD TE733M TF733M 115 ZP TA734 TC734 TD734 115 Diode DP TE734M TF734M 125 ZS TA737 TC737 TD737 125 Diode DS TE737M TF737M 220 ZA TA747 TC747 TD747 220 Diode DA TE747M TF747M 230 ZF TA749 TC749 TD749 230 Diode DF TE749F TF749F 250 ZT TA751 TC751 TD751 250 Diode DT TE751F TF751F oltage operating range: 0.65 1.3 x Us. oltage operating range: 0.7 1.25 x Us. Bulletin 190 IEC Modular Starter System AC Operating Coils Used with Cat. Nos. 190-A40, 190-CPS40, and 190R-CPS40 oltage [] Frequency [Hz] Cat. No. 24 50 JB407 24 60 JB013 110 50 JB473 120 60 JB473 208 60 JB049 220 50 JB474 240 60 JB474 380 50 JB454 415 50 JB457 440 50 JB475 480 60 JB475 550 50 JB476 600 60 JB476 Bulletin 193 Overload Relays with Current Transformers For Use With Panel Adapter Assembly Cat. No. Overload Relay Only Cat. No. 193-HPD110 40781-607-01 193-NX23 193-DPC88 40781-607-01 193-NX24 193-DPD120 40781-607-01 193-NX25 193-DPD200 40781-607-01 193-NX26 193-EPD180 40781-607-01 193-NX27 193-EPD300 40781-607-01 193-NX28 193-FPD240 40781-607-01 193-NX29 193-FPD40 40781-607-01 193-NX30 193-GPD378 40781-607-01 193-NX32 193-GPD630 40781-607-01 193-NX33 Contact kits for Cat. Nos. 100-A09 100-A30 are not available as replacement parts.

AC Operating Coils Used with 193-GPD Devices oltage Frequency [Hz]Cat. No. 24 AC 50 HA407 24 AC 60 HA013 110 AC 50 HA473 110 AC 60 120 AC 50 120 AC 60 HA473 208 AC 50 208 AC 60 HA049 220 AC 50 HA474 220 AC 60 HA051 240 AC 50 HA442 240 AC 60 HA474 277 AC 60 HA060 380 AC 50 HA454 380 AC 60 415 AC 50 HA457 440 AC 50 HA475 440 AC 60 HA071 480 AC 50 480 AC 60 HA475 500 AC 50 HA464 500 AC 60 600 AC 60 HA476 Description Coil Type For Use With Cat. No. Arc Chambers for Contactors Conventional 100-D95 100-DA-95 For 3-pole 100-D Contactors 100-D110 100-DA-110 100-D140 100-DA-140 100-D180 100-DA-180 Electronic 100-D95 100-DAE-95 100-D110 100-DAE- 110 100-D140 100-DAE- 140 100-D180 100-DAE- 180 100-D210 100-DAE- 210 100-D250 100-DAE- 250 100-D300 100-DAE- 300 100-D420 100-DAE- 420 Main Contacts for Contactors Conventional 100-D95 100-DC-95 Set for 3-pole 100-D Contactors 100-D110 100-DC-110 100-D140 100-DC-140

Terminal Hardware Set of 6 100-D180 100-DC-180 Electronic 100-D95 100-DCE-95 100-D110 100-DCE-110 100-D140 100-DCE-140 100-D180 100-DCE-180 100-D210 100-DCE-210 100-D250 100-DCE-250 100-D300 100-DCE-300 100-D420 100-DCE-420 100-D630 100-DCE-630 100-D860 100-DCE-860 Conventional 100-D95 D110 100-DHF110 100-D140 D180100-DHF180 Electronic 100-D95 D180 100-DHF180 100-D210 D420100-DHF420 100-D630 D860100-DHF860 Bulletin 100-D Replacement coils Conventional AC AC Standard Control oltages 50 Hz 60 Hz 50/60 Hz Conventional DC AC 100-100- 100- DC DC 100-100- 100- Coi D95 D D210 DD630 DStandar Coi D95 D D210 DD630 D l 180 420 860 d l 180 420 860 Co Cat. No. Cat. No. Cat. No. Control Co Cat. No. Cat. No. Cat. No. de oltage de s 24 K TG407 12 ZQ TG708 24 J TG013 24 ZJ TG714 32 36 TG481 36 ZW TG719 36 42 W TG410 48 ZY TG724 48 Y TG414 60 ZZ TG774 42 48 X TG482 110 ZD TG733 100 KP TG861 125 ZS TG737 110 120 D TG473 130 ZF TG738 110 KN TG856 220 ZA TG761 208 H TG049 240 ZL TG750

200 KG TG862 250 ZT TG751 220 KL TG857 220 2 240 A TG441 30 240 277 T TG480 277 KT TG060 230 KF TG851 240 KA TG858 380 4 440 N TG071 00 415 480 B TG475 440 G TG478 500 M TG479 550 600 C TG476 Electronic AC Electronic DC AC Standard AC 100-100- 100- DC DC 100-100- 100- Control oltages Coi D95 D D420 D630 DStandar Coi D95 D D420 D630 D l 300 860 d l 300 860 50 Hz 60 50/60 Co Cat. No. Cat. No. Cat. No. Control Co Cat. No. Cat. No. Cat. No. Hz Hz de oltage de 24 EJ TGE855 24 EZ TGE708 J 42 64 EY TGE864 48 72 EZ TGE779 Y 100 EP TGE861 THE861 TJE861 110 1 30 EZ TGE780 THE780 D 110 1 30 ED TGE865 THE865 TJE865 ED TJE865 200 EG TGE862 THE862 200 2 55 EZ TGE781 THE781 A 208 2 77 EA TGE866 THE866 EA TJE879 200 2 EG TJE878 20 230 2 EA TJE879 50 277 ET TJE880 380 5 00 EN TGE867 THE867 380 4 EN TJE867 15 440 4 EB TJE868 80 500 EM TJE869 600 EC TJE870

Applies to 100-D95 -D110 contactors only. Not available with 100-D140 -D180 contactors. Not available on 100/104-D300. Bulletin 100-G Renewal Parts Description Arcing Chamber For 3 poles For Use With Cat. No. 100-G550 100-AC550 100-G700, 100-AC860 100-G860 Arcing Chamber For 1 pole 100-G1000, 100-G1200 100-AC1200 Main Contact Set Set for 1 pole Auxiliary Contact Block Special 2-pole design: 1 N.O. delayed make, 1 N.C. contact N.O. delayed make contact used for operation of the Feeder/Group Coil mechanism One contact block supplied standard with contactor 100-G550 100-CP550 100-G700 100-CP700 100-G860 100-CP860 100-G1000 100-CP1000 100-G1200 100-CP1200 100-G1000, 100-EB11DC 100-G1200 Coils and Supply Modules AC Standard Control oltages DC Standard Control oltage Coil Code100-G550 100-G700...100- G860 50/60 Hz 110 120 100 110 KD TX734TXS734TY734 TYS734 220 240 200 220 KF TX747TXS747TY747 TYS747 380 415 345 380 KN TX779TXS779TY779 TYS779 440 480 400 440 KB TX780TXS780TY780 TYS780

Coils sold in pairs. AC Standard Control oltages 50/60 Hz Coil Code100-G1000...100-G1200 Coil Cat. No. Supply Module Cat. No. 110 115 KD TZ734 TZS734 220 230 KF TZ747 TZS747 380 400 KN TZ779 TZS779 440 KB TZS780 TZS780