Henkel Installation Handbook LINEGUARD 2001

Similar documents
Label Applicator HERMA 400

Standard RS232 RS ma

Digital output modules

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Wall-/Pipe-Mount Level Indicator

FLOMAT Electromagnetic Insertion Flowmeter

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

DLP600M 6+1 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

TOSHIBA Industrial Magnetron E3328

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

MS2540 Current Loop Receiver with RS485 Communication

LED Driver Linear / area fixed output

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Fibre Optic Modem ODW-622

Sensopress LCD Special English

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Telemetry Receiver Installation Guide

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Gamma instabus. Technical product information

AS09..S 3-pole Contactors - Spring Terminals

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Multifunction Digital Timer

LED Driver Compact fixed output

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Spectra Batten (Order code: LEDJ95)

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

IGNITION TRANSFORMER FOR BURNERS

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

multi-function meters

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact dimming

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Rack mounted telephone- and leased line modem for industrial applications

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

T +31 (0) F

LED Driver Compact fixed output

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LED control gear Compact fixed output

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

CERTIFICATE of EU TYPE-EXAMINATION

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Model KBF 115 Constant climate chambers with large temperature / humidity range

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Magnecraft Power Relays

LED Driver Compact fixed output

Process transmitter RMA422

LED MODULES READYLINE DL

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

LONWORKS Fibre Optic Converter

Inductive sensor BI1.5-EG08K-Y1

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

Telemetry Receiver Installation Guide

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

DCP100 Digital Control Programmer Specifications

MICROPROCESSOR CALCULATION MODULE - S2000

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Capacitance Limit Detection nivotester FTC 420/421/422

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

Trusted 40 Channel 120 Vac Digital Input FTA

1 Power Protection and Conditioning

Model KBF 1020 Constant climate chambers with large temperature / humidity range

PRINCIPLES AND APPLICATIONS

Modular Lube Lubrication Systems System Controls

TECHNICAL SPECIFICATION

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

The Art of Engineering

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

2.9 Sigma/ 2 Plunger Metering Pumps

Model IQ4-PC User Manual Revision Date:

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

Inductive sensor NI3-EG08K-Y1-H1341

Digital differential Pressure switch Model DPS Instruction manual

Trusted 40 Channel 120 Vac Digital Input FTA

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Inductive sensor NI10-M18-Y1X-H1141

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Interface Relays and Optocouplers Product group picture

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

TABLE OF CONTENTS. Instructions:

Switching Power Module

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

Transcription:

Henkel Installation Handbook LINEGUARD 2001

HENKEL ITALIA S.r.l. Microprocessor instruments Henkel Installation Handbook Lineguard 2001 Page 2

Summary 1. The Microprocessor Instruments... 4 1.1. Norms of Installation... 4 1.2. Technical Characteristics... 4 1.3. Main Technical Notes... 4 1.4. Technical Specifications... 5 2. Introduction... 6 2.1. Prescription LINEGUARD 2001... 7 2.2. General Prescriptions for the Installation... 8 2.3. Technical Prescription... 9 3. Wiring Diagram... 10 3.1. Cables List... 19 3.2. Hydraulic Connections... 21 Henkel Installation Handbook Lineguard 2001 Page 3

1. The Microprocessor Instruments The microprocessor instruments LINEGUARD series are the most adaptable to whichever requirement of customer. Thanks to their programming and theirs robustness, can be installs in the most varied methodologies system. 1.1. Norms of Installation Make sure to place the LINEGUARD 2001 far away from heat sources. Feed LINEGUARD 2001 with 220 stabilized VAC (possibly connected to same 220 VAC used from computers or similar). To avoid to place the instrument on bases or pedestals, subject to vibrations. Don t place the cables for conductivities probes or ph transmission inside cable channel where there is cables of feeding to high voltage 380 V. 1.2. Technical Characteristics Container of the electronics Cable holder unit electronic Weight (total) Feeding electrical worker Hydraulic feeding Climatic Conditions Display Other incomes Width 300, height 260, depth 120 in ABS; IP65 PG9 for serration cables 5...7mm of diameter (others configurations upon request) Approximately 7 kg 220 +/- 10% 50-60 Hz, 40 GO minimum 10 l/h and 0.2 BAR Storage temperature -20...+60 C Temperature of exercise -10...+50 C Humidity MAX 90% without condenses Alphanumeric LCD two lines for 16 characters On terminal box high isolation. 1.3. Main Technical Notes 1. Programmable output relay set-point, min-max alarms, auto cleaning. 2. Galvanic separation between input/microprocessor and current output. 3. Alarms and errors (diagnostic) visualize directly on the display. 4. Always time dater, also in feeding absence. Henkel Installation Handbook Lineguard 2001 Page 4

5. Rescue of the data program/calibration on memory (retention minimum 10 years). 6. RS232C output for data exchange with PC, PLC and software LINEGUARD DIGILOG. 1.4. Technical Specifications Standard combinations Possible combinations Input specifications Output relay In1(mis1)=pH, In2(mis2)=mV, In3(mis3)= C In4(mis4)=mA. In 1: ph, redox In 2: ph, redox In 3: ph, redox, ms, ma o Volt In 4: ph, redox, ms, ma o Volt ph: standard 0.00... 14.00 ph. Impedance input > 10^12. Precision better than 0.02 ph, repeatability better than 0.01 ph Rx: standard -1000...+1000 mv Impedance input > 10^12 Precision better than 0.02 mv, better repeatability of 0.01 mv ma: Whichever scale specify to the order. Better precision of the 0.1% of the F.S., better repeatability of the 0.05% of the F.S. N 5 for regulations ON-OFF called K1,K2,K3,K4 and K5. output relay are free contact. N 4 for alarms ON-OFF called K6,K7,K8,K9 output relay are free contact. They are available on terminal box. Contacts capacity max 250 VAC 3A. All the input and the output are on terminal box. Henkel Installation Handbook Lineguard 2001 Page 5

2. Introduction Henkel can modify the instrument or the handbook without warning. The handbook describes standard version. The indications in this document represent the peripheral electrical connections for the correct installation of LINEGUARD 2001. The electronic planning of the Lineguard and all the devices connection has been executed from the HENKEL, which assures one corrected functionality and guarantee some regarding European norms. Electronic characteristics of the input and output are brought back to page 4. In standard version, the LINEGUARD 2001 is complete of: 1. n. 1 electronic unit 2. n. 3 dosing pumps VMF 3. n. 1 set for wallet installation 4. n. 1 electrode of ph 5. n. 2 probes conductivity induction 6. n. 1 probe of conductivity 7. n.4 amplifier-converters of signal The wiring diagram in function of the real requirements, could be modified, respecting however the general criteria indicates in the standard typology. The remote control switch of the re-circulate pump isn t supplied by HENKEL, but it must be present in the system. Henkel Installation Handbook Lineguard 2001 Page 6

2.1. Prescription LINEGUARD 2001 1. All the clips are not always present in the input, depend on the initial configuration (Vs. order). 2. To exchange phase with neutral of the feeding it means to have the inner fuse of protection (F1) connected to the neutral instead to the phase; for the Lineguard 2001 is not important. 3. The feeding earth (clip 3) is connected to the grounding of the electrical system. The connection is not obligatory for the emergency, (draft of an apparatus of class II) but is indispensable to dispel eventual disturbs coming from electrical line of feeding. 4. The output max load relay is 3A to 250V A.C.; with inductive the max current is 1A (can be supply directly pumps or electro valves with powers of 200VA to 220V A.C.). 5. In event of output in tension (24V A.C.), the max power is of 20VA; eventual overloads can burn fuse of protection F2 1A. 6. In the inductive case the output must be protect with opportune systems of arches disturbs suppression. Inner to Lineguard 2001 they are previewed suppressors for 250V A.C. if contacts output or for 24V A.C. if in tension output. A corrected suppressor of disturbs must determinate by the customer in function of the cargo/feeding. 7. In order to obtain a correct operation of the apparatus also in worse disturbance conditions, we advise following prescription: a. block ferrite radio frequency in the feeding cable; b. shielding of input cables signal with connected metallic girdle to earth; c. suppressors RC (or equivalents) in parallel to the cargo (determine the proportions opportunely) d. good connection to earth of the Lineguard; e. shielding with grounding of output current cables in case to exceeds 20m of length. Henkel Installation Handbook Lineguard 2001 Page 7

2.2. General Prescriptions for the Installation Classification of the installation system place and respect of CEI norms: Classification of the fundamental system and norms CEI: ordinary system CEI 64-8 IV ed. system risk in fire case CEI 64-8/7 IV ed. system with danger of outbreak CEI 31-30, CEI 31-33, CEI 31-35/A, etc. Analysis of atmospheres: temperatures of exercise - 10/+ 50 C to avoid installation in proximity of heat sources implantations in structures not subject to vibrations install far away from zones with elevated presence of water and humidity 90% to avoid the contact with chemical agents to avoid installation in zone with presence of systems that can generate disturbs (magnetic). Henkel Installation Handbook Lineguard 2001 Page 8

2.3. Technical Prescription The installation and the eventual maintenances of such systems must to be executed from a qualified installation company. To respect the supplied indication in the wiring diagram, with particular cure for numeration of conductors (ex. L1 cable conductors 1-2-PE). Devices connections with cables type: see tab. 1. Cables rest, previously indicates, in ducts dedicated and opportunely chosen in function of the installation atmosphere. Ducts with isolate cables for the high voltage, isolation 450/750V and max tension of exercise 250V. The splices must to be executed with clips in opportunely derivation box, with protection minimal IP 44 and chosen in function of the installation atmosphere. The Lineguard and the amplifiers converters coverings, are supplied with protection minimal IP 44, with cable holder PG7 from 5-7 millimetres and in II class. Feeding from mains voltage 220V +/- 10%, 50/60 Hz. Measure of the short circuit current in the point of feeding of the Lineguard. Verification that the values of the short circuit currents F-F, F-N and F-PE, is inferior to the interruption power of the switch. Measure of the earth resistance in the feeding point; verify that value is inferior to 833 ohm, tension of contact Vc = 25V, Idn = 0,03A [ Rt = Vc/ Idn = 25/0,03 = 833ohm ] Henkel Installation Handbook Lineguard 2001 Page 9

3. Wiring Diagram Henkel Installation Handbook Lineguard 2001 Page 10

Connection Lineguard 2001 Particolar Henkel Installation Handbook Lineguard 2001 Page 11

Connection SG91mV/mV ph particular Henkel Installation Handbook Lineguard 2001 Page 12

Connection SG96 Particolar Henkel Installation Handbook Lineguard 2001 Page 13

Connection SG05 CO Particolar Henkel Installation Handbook Lineguard 2001 Page 14

Connection Dosing Pump Particolar Henkel Installation Handbook Lineguard 2001 Page 15

Connection Remote Control Switch Particolar Henkel Installation Handbook Lineguard 2001 Page 16

Connection Lineguard 2001 + Alarm Box (Example) Henkel Installation Handbook Lineguard 2001 Page 17

Connection Lineguard 2001 Long Distance (Digilog 4.0 Connection) Henkel Installation Handbook Lineguard 2001 Page 18

3.1. Cables List CABLES LEGEND Multipolar Shielded cables type FR20HH2R 450/750 V (CEI 20-21 II / CEI 20-37 I) INITIAL CABLE NUMERATION SECTION (mm 2 ) L1 1-2-PE 3X1,5 L2 15-16-PE 3X1,5 L3 5-6-PE 3X1,5 L8 31-32-PE 3X1,5 L10 35-36 2X1,5 L11 37-38-PE 3X1,5 L12 41-42-PE 3X1,5 L13 45-46-PE 3X1,5 L14 49-50-PE 3X1,5 L15 39-40 2X1,5 L16 43-44 2X1,5 L17 47-48 2X1,5 L18 51-52 2X1,5 L19 17-18 2X1,5 L20 19-20 2X1,5 L21 27-28 2X1,5 L22 29-30 2X1,5 L23 9-10-PE 3X1,5 L24 7-8 2X1,5 L25 53-54 2X1,5 Coaxial Cables RG (Directions MIL C e IBM) INITIAL L4 L5 TYPE Coaxial cable (RG 58 C/U) MIL C17/E 50 OHM M 17/28 RG 58 (RG C/U) RS 19x0,18 Henkel Installation Handbook Lineguard 2001 Page 19

Special Cables Plus Probe INITIAL CABLE NUMERATION SECTION (mm 2 ) L6 11-12-13-14-15-16 6X0,5 L7 21-22-23-24-25 26 6X0,5 Special Cables Plus Probe INITIAL CABLE NUMERATION SECTION (mm 2 ) L9 33-34 2X0,5 Henkel Installation Handbook Lineguard 2001 Page 20

3.2. Hydraulic Connections. Henkel Installation Handbook Lineguard 2001 Page 21

Hydraulic Connections (Inox tube probe) Henkel Installation Handbook Lineguard 2001 Page 22

Hydraulic Connections (Inductive probe) Henkel Installation Handbook Lineguard 2001 Page 23

Hydraulic Connections (cck5 probe) Henkel Installation Handbook Lineguard 2001 Page 24

Hydraulic Connections (Washing panel) Henkel Installation Handbook Lineguard 2001 Page 25

Henkel Installation Handbook Lineguard 2001 Page 26