AT47SAW Programmable Selective Amplifier

Similar documents
AT450SAW Programmable Selective Amplifier

ATS50SAW Programmable Selective Amplifier

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

Multi Channel Programmable Filter-Equalizer. Use Manual. Digital. Terrestrial. Ref. : 6505

beyond your expectations

Single cable multiswich programmer PC102W

Multi channel programmable Filter-Amplifier

SAT IF distribution system

Noise Detector ND-1 Operating Manual

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

Satellite B or D. Satellite Inputs (LNB Trunk)

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

USB Smart Power Sensor

User Manual. Profiler Revolution Ref PATENT PENDING. SW Version 1.3.0

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

12.1 Inch CGA EGA VGA SVGA LCD Panel - ID #492

MAW-201 (3031) MULTISTANDARD VHF/UHF TV MODULATOR

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

21 Channel Light Show PWM LED Controller with Remote Control

Technote 1: Setting up ZA- 431/331 processor modules

Installation location

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

Multicom Optical Return Path Receiver MUL HRPR 4B

28 4K LED monitor. User Manual M284K

USB Smart Power Sensor

Applications & Features of the SB- SDQM- 2130

USB Smart Power Sensor

DM1624, DM1612, DM812

HD-CM HORIZON DIGITAL CABLE METER

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Electronic converter for level transmitters MT03L Instructions manual

Siteco Service Box User Manual 1/31

USB Mini Spectrum Analyzer User s Guide TSA5G35

CM 4HD-TC. Digital encoder-modulator 4 HDMI-COFDM/QAM. User s Manual

TM180HD. HD encoder DVB-T out USER MANUAL V1.0

Extra long-range RFID (proximity) card reader

MT03A Electronic converter for flow rate transmitters

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion.

15 Inch CGA EGA VGA to XGA LCD Wide Viewing Angle Panel ID# 833

User Manual POE. Twisted Pair POE Extender

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

Revision 1.2d

R-1580A Microwave Downconverter. Product Brochure

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Compact Mini Amplifiers Series and Series

AW900mT. User s Manual. Point-to-multipoint. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

MyM-3S Micro Master. Installation Guide. English. design for TV

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

MULTIBANDE HEADENDS. ONEZERO. Programmable Terrestrial Filtering Header. Broadband Catalogue 39

NS-3 RF Noise Source Operation Manual

Installation & Operational Manual

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

DVB-T Box, USB Monheim/Germany Tel. +49 (0)9091/ Fax +49 (0)9091/ Hama GmbH & Co KG.

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

Smart Control SC16 3-Channel for matrix

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

Intelligent Security and Fire Ltd

DX-10 tm Digital Interface User s Guide

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Ten-Tec (865) Service Department:(865)

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

USB-TG124A Tracking Generator User Manual

TV4U DVB-S2 to DVB-S2 TRANSMODULATOR

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Compact EGC Amplifier Model 93250

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

SDA 3302 Family. GHz PLL with I 2 C Bus and Four Chip Addresses

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

FOREST SHUTTLE S / L / M RECEIVER

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Model 5240 Digital to Analog Key Converter Data Pack

It receives contents from 4 DVB-T/T2, DVB-S/S2 or DVB-C transponders/muxes and broadcasts them in 4 DVB-T, DVB-C or IP output channels.

Outdoor & Indoor Full Color LED Display Screen. Installation Manual

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

User guide MAW-300. Ref HD Encoder & Modulator HDMI to DVB-T

Configuration and setting guide. ONE series ONESAT ; ONE118 ; ONEHOME. Programmable multichannel amplifiers

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

Single & Dual Input HD Digital DVB-T Modulators

Video Wall Display User s Manual

Installing the FOREST SHUTTLE S / L

ED5229GT-E/GTRE Series

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

VSP 198CVS Quick Start

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

AMD-53-C TWIN MODULATOR / MULTIPLEXER AMD-53-C DVB-C MODULATOR / MULTIPLEXER INSTRUCTION MANUAL

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Transcription:

AT47SAW Programmable Selective Amplifier LEMELETTRONICA srl Via Grezze 38 25015 Desenzano del Garda (BS) ITALY Tel. +39 030-9120006 Fax +39 030-9123035 www.lemelettronica.it

Technical Specifications N Input BI/BII (40 108 MHz) 1 N Input BIII/DAB (170 320 MHz) 1 N Input UHF Selectable 470 790 MHz/470 700MHz 2 N Programmable Clusters 7 N Channel per Cluster 1 7 (8 56 MHz) UHF Cluster Settings UHF1 UHF2 7 0 6 1 5 2 4 3 Clusters Gain Adjustment 0 30 db Clusters Selectivity +/- 10 MHz 12 db VHF Input attenuators 0 25 db UHF Input attenuators 0 20 db UHF Input range 60 100 dbµv Gain UHF 40 db Gain VHF 35 db Max Output Level 119 dbµv Noise Figure VHF 6,5 UHF 6,5 Return Loss In/Out >12 db Remote Power Supply VHF UHF 12/24 VDC 100 ma Supply Voltage (External power supplier) 230VAC +/- 10% Max Power Consumption 8 W Programming Port USB Dimensions 192 x 217 x 37 mm Electrical Diagram

Congratulations for buying the AT47SAW programmable selective amplifier. Read carefully the following instructions to ensure correct operation of the amplifier. Safety instructions - Do not expose the amplifier to extreme temperatures. - Place the amplifier in a dry and well-aired location. - Install the unit on a vertical wall, or in a waterproof cabinet to a minimum IP55 rating, and fix it safely using the special through holes supports. INSTALLATION AND START-UP - Connect the ground wire (you find it on the amplifier s chassis) to the IRS or MATV earth. - Connect the TV aerial(s) to the amplifier s inputs. - Terminate the unused inputs with 75Ω terminators. - Connect the supplied power pack. - Only then connect the amplifier to the mains plug. IMPORTANT! Use only the power pack supplied together with the amplifier. The use of other power packs can cause malfunctioning and irreparable damages which will invalidate any warranties. Programming It is possible to programme the AT47SAW from either the front panel controls or from a the GUI software which is downloadable free of charge from our website LEM Graphic User Interface (GUI) From the download area in our website http://www.lemelettronica.it. it is possible to download a special free PC compatible software conceived to operate with the AT47SAW amplifier from your PC. Hardware requirements PC Windows compatible with USB interface. Processor 800MHz or more. 256Mb RAM USB A-B cable. Software minimum requirements Windows XP SP2 operating system or more recent Microsoft Framework.NET 3.5* or higher and langpack (free download from Microsoft website). Installation procedure Close all the active applications (included antivirus programs) Start the Setup.exe program Follow the guided procedure until the installation is completed

The program needs the Framework.NET 3.5 or higher to work. It is usually in the PC if there is a recent version of Windows XP. If not the Framework.NET can be freely downloaded from the Microsoft website. Use If correctly installed and started the GUI software will automatically find the USB interface of the AT47SAW amplifier, then all the setting, reading and storing operations, are available. Android Tablet e Smartphone Programming Hardware requirements Android OS Tablet or Smartphone with USB supporting the On The Go (OTG) mode USB A-B Cable USB-OTG Cable Adapter Software requirements Android OS 4.0 or successive release Application Installation Procedure The application LEMGUI can be free downloaded from Google Play https://play.google.com/ Power the AT47SAW connecting the power supplier unit. Connect the USB-OTG cable and the USB A-B cable to tablet/smartphone. Swith on the tablet/smartphone and connect The cable to AT47SAW. The tablet/smartphone automatically activate the application recognizing the programmable amplifier model.

Manual Programming (from the keys on the front panel of the amplifier) At start-up (i.e. connection of the mains cable) the letter b will appear on the display. It indicates the microprocessor boot phase. Then the release Firmware will be indicated for a while to confirm the correct system initialization. At the end of the start-up procedure the amplifier is in the POWER ON status. This status is indicated by the lighting of the fourth LED on the display. The POWER ON status denotes that the amplifier is operative and ready to be programmed. PARAMETERS SET AND PROGRAMMING A 4 digit display indicate the amplifier s selectable modes. Using the UP, DOWN and ENTER keys you can see the factory set parameters and program new ones. LED fixedly on LED blinking slowly LED blinking rapidly Parameters visualisation Parameters configuration Not desirable programming or setting To access the UHF input attenuators programming menu: press the DOWN key for 3 seconds. To access the clusters programming and UHF-VHF output level adjustment menu: press the ENTER key for 3 seconds. To access the programming menu of the remote supplies by the inputs: press the UP key for 3 seconds. Any change of the parameters (blinking display) must be confirmed by pressing the ENTER key. In this way it will be permanently stored. Note To quit any programming menu: press the UP and the DOWN keys simultaneously, this will happen automatically after 5 minutes if the menu is unused.

1) Lte G4 / G5 selection filter The AT47SAW UHF inputs are protected by selectable Lte G4 or G5 filters. To select the proper Lte filter press the key ENTER for 3 seconds and the display will prompt Lt E.5 for G5 (blue led) to set a different Lte filter press again ENTER and the display start to blink, press UP or DOWN keys to select the proper filter and confirm pressing ENTER. Lt E.5 = 5G mode (blue led) UHF channel range 21 48 Lt E.4 = 4G mode (green led) UHF channel range 21 60 2) UHF inputs attenuator This is manually adjustable from 0 to 20 db. To access the UHF attenuators programming menu: - press the DOWN key for 3 seconds. - the display will show the word U1.00. : this indicates that the UHF1 input attenuation level is at zero. - press the ENTER key. The display will start blinking. This indicates the parameters setting mode. - press UP or DOWN to adjust the attenuation level from 0 to 20dB. The display will return with a fixed light, this indicates that the new setting was saved. NOTE: the attenuation settings will be cancelled if you do not press the ENTER key for confirmation at the end of the procedure. To adjust the UHF2 and UHF3 input attenuators: - press UP or DOWN to choose the desired attenuator. - then follow the described procedure above. To leave the remote power supply setting menu: - press the UP and DOWN keys simultaneously. - the display will return to POWER ON status. 3) selection of the cluster-groups configuration There are 4 possible configurations: Input UHF1 UHF2 Cluster-groups 7 0 6 1 5 2 4 3 You can enter into these configurations by pressing the ENTER key for 3 seconds. The display indicates the selected configuration: it views the cluster-groups corresponding UHF inputs.

Note: The cluster-group 6-1 assigns: 6 clusters to the UHF1 input and 1 cluster to the UHF2 input. Each cluster can be programmed for a bandwidth variable from 8 to 56 Mhz. with a 8 Mhz. step, that means from 1 to 7 UHF channels with 1 channel steps. To select a different configuration: - press ENTER : the display starts blinking. - press UP or DOWN to choose the desired configuration. - press ENTER again to confirm your choice: the display will return with a fixed light and it will show the selected configuration. 4) UHF cluster attenuation levelling The attenuation of each cluster can be levelled from 0 to 30 db with 1 db steps. The cluster can also be switched off. This function will be shown on the display by the visualisation of L+ cluster number. Procedure From the cluster-groups visualisation/configuration mode you can sequentially go to the visualisation of the clusters levels + channels parameters. To enter into the adjustment mode: - press the ENTER key. The display will start blinking. This indicates the parameters setting mode. - press UP or DOWN to adjust the cluster s attenuation level. To deactivate a cluster: - press the ENTER key.the display will start blinking. This indicates the parameters setting mode. - press the UP and DOWN keys simultaneously. - the display will show the word o F. - 5) Clusters amplitude setting The bandwidth (from 1 to 7 channels) and the attenuation level (from 0 to 30 db Typ) of the 10 clusters can be independently adjusted. For the setting you need to select the desired cluster (F1 F0) and then adjust the attenuation level, if you require to use it, or switch it off choosing o F. Afterwards you can select the cluster s start and stop channels. If you switch a cluster off, it is better to reset its channels to zero choosing o F.

Procedure - start from visualisation mode (display fixed switched on) of the first cluster s level settlement. - press the UP key: the display will show the F1 cluster. - The display will also indicate the F1 cluster s start channel by the lighting of the second LED. - press UP again. - the display will show the F1 cluster s stop channel followed by a dot F I 27. Note: If the start channel is at the same value as the stop one ( single-channel setting) the display will indicate this mode viewing the word o F as cluster s stop channel F I of. To reset the cluster s start channel: - select the desired cluster on the display. - the lighting of the second LED confirms that you are at the cluster s start channel. - press the ENTER key.the display will start blinking. - press UP to increase the channel s number or DOWN to decrease it. To reset the cluster s stop channel: - press the UP key. - the lighting of the fourth LED confirms that you are at the cluster s stop channel. - press the ENTER key.the display will start blinking. - press UP to increase the channel s number or DOWN to decrease it. To deactivate the cluster s start or stop channel: - press the UP and DOWN keys simultaneously. - the display will show the word o F. Note: Channel overlapping is possible and it is shown on the display by the rapid blinking of the overlapped clusters. Note: The setting of the F1 cluster s start channel at the value 21 and of the stop channel at the value 24 while the F2 cluster has the start channel at the value 24 and the stop channel at the value 26 implicates an overlapping of the F1 cluster s stop channel with the F2 cluster s start channel.

5) Interstage attenuator regulation (UHF output level) After the input levels setting a further adjustment of the total output level of the UHF signals can be useful. Procedure - press the UP or DOWN key to select LU.00 on the display. - press the ENTER key.the display will start blinking. This indicates the parameters setting mode. - press UP or DOWN to adjust the UHF total attenuation level. 6) B I/FM and B III/DAB input level adjustment. The B I/FM and B III inputs are provided with level attenuators from 0 to 25 db with 1 db step. Procedure - press the UP or DOWN key to select b1.00. or b3.00. on the display. - press the ENTER key. The display will start blinking. This indicates the parameters setting mode. - press UP or DOWN to adjust the band I and band III cluster attenuation level. NOTE: the attenuation settings will be cancelled without pressing the ENTER key for confirmation at the procedure s end. 7) Clusters Self-Alignment Setting SELF-ALIGNMENT can be used after programming all the UHF clusters. Running this function the programmable amplifier will automatically level all clusters to get an equalized and optimized output. To set the SELF-ALIGNMENT select the L. E. v. L. menu and press the ENTER key, when the display start flashing press again the key ENTER and the display show the word A D J followed by a moving cursor. Wait till the procedure is finished. The SELF-ALIGNMENT algorithm provides an UHF output level standard of 100 dbµv. With input UHF signals 70 dbµv the inter-stage attenuator will be set at 10dB level. This allows an output level range that can be set from 95 dbµv to 110 dbµv. With input UHF signals 60 dbµv and 70 dbµv the inter-stage attenuator will be set at 0 db. This allow an output level range that can be set from 80 dbµv to 100 dbµv. With input UHF signals that are too low, to guaranty a good Signal/Noise ratio the display alert will show the cluster number followed by the symbol Lo. Press the key ENTER to continue. With input UHF signals too high the display alert will show the cluster number followed by the symbol HI. Press the key ENTER to continue. Safety Code To enable or change the safety three digit PIN code go to the P.000 menu, press the key ENTER to activate the procedure (flashing display) press the keys UP or DOWN to set the first digit and confirm pressing ENTER. Follow the same procedure to set the other two digits. The code P.000 = PIN code disabled (default setting).

7) Remote power supply Each RF input can supply 12 or 24 VDC power, 100mA. * *amount of the total consumption of all the remote power supplied inputs. Procedure - You can enter into the remote power supply setting menu only if the display is in POWER ON status. - if the amplifier is not yet in the POWER ON mode, then press the UP and DOWN keys simultaneously. - keep pressing the UP key for 3 seconds. - the display will indicates the remote power supply menu. To set the remote power supplied voltage: - press the ENTER key. The display will start blinking. This indicates the parameters setting mode. - press UP or DOWN to select 12 or 24 Volt voltage. To switch on the remote power supply or to check its presence at the UHF and VHF inputs of the amplifier: - press UP or DOWN. - the UHF1, UHF2, bi, biii inputs will be sequentially viewed on the display. - for each input: of means that input doesn t provide remote power supply. - for each input: on mean that input provides remote power supply. To change the mode: - press ENTER. - press UP or DOWN to select on or of. To leave the remote power supply setting menu: - press the UP and DOWN keys simultaneously. - the display will return to POWER ON status. If a short circuit or an overload occurs to one input or more, the first LED on the display will start blinking. In case of short circuit: switch the amplifier off by disconnecting the mains cable. Remove the problem s origin, then switch the amplifier on. 8) Amplifier s initial setting restoration The amplifier can be reset at any time, this restores the initial factory setting. This will remove all of the individual settings that have been previously entered. The amplifier will need to be reprogrammed at this stage.

Procedure - disconnect the mains cable of the power supplier unit from the 220V electric system. - keep pressing the ENTER key. - in the meantime reconnect the 220V mains cable. - wait till the display indicates 4 hyphens (it means that the reset was successful). - then release the ENTER key. - the display will return to POWER ON status. - now the amplifier is programmable again.