X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Similar documents
CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

DT3130 Series for Machine Vision

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Fiber-coupled light sources

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

GFT Channel Digital Delay Generator

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Fluorescence Spectrophotometer

CBF500 High resolution Streak camera

Create excitement in your venue

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

User Manual. pe-300 Series. White Light Fluorescence Illumination System. DOC-005 Iss 8 1

Quick Start Guide. Multidimensional Imaging

Synthesized Block Up- and Downconverter Indoor / Outdoor

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

Engineered to meet your needs T he oldest name in stud welding,

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy) HP L5006tm 15-inch LCD Touchscreen Monitor

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

MTS/T-BERD Platforms WDMPMD Module

Mosaic. Mosaic Real Time Parallel Illumination of Multiple Regions. Features and Benefits. DMD Technology. Specifications Summary

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

V9A01 Solution Specification V0.1

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

Live events staging. Media centers

SPATIAL LIGHT MODULATORS

Boosting Performance Oscilloscope Versatility, Scalability

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

EW400. Plug and Play Projection. Native WXGA, 4000 ANSI Lumens. USB plug and play presenting. Up to 6000 hours lamp life and 70% energy saving

Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Satellite Up- and Downconverter Indoor / Outdoor

VPL-HW45ES Home Theater Projector

VPL-DX102. 2,300 lumens XGA Desktop projector. Overview

SC26 Magnetic Field Cancelling System

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

SMART Board interactive whiteboard system Model 685i5

Home Cinema LS100 Full HD 3LCD Ultra Short-throw Laser Projector

Spiider THE NEXT BIG THING FROM ROBE!

TRANSDUCTION USER S MANUAL. TR-LCD1900-OCD 19 Rack/Panel Mount TFT LCD Monitor with Front LCD Controls

QuickSpecs. HP V214a 20.7-inch Monitor. HP V214a 20.7-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

SmartCrystal Cinema Neo

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

SmartCrystal Cinema Neo

QuickSpecs. HP N inch Monitor. Technical Specifications

Truck router (3Gbps/HD/SD/ASI)

imso-104 Manual Revised August 5, 2011

SMART Board interactive whiteboard system Model 685i5

Spatial Light Modulators XY Series

013-RD

Oscilloscopes for field applications

Agilent 81600B Tunable Laser Source Family

Specifications SMART Hub SE240 with SMART Board SB680i2. Model SB680i2-SE240. Physical Specifications. SMART Board 680 Interactive Whiteboard

STAR-07 RGB MULTI-COLOR INDUSTRIAL PATTERN PROJECTION

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

Sharp Electronics Corporation Consumer Electronics Group, Sharp Plaza, Mahwah, NJ Call us toll free at BE-SHARP

QuickSpecs. Models Part Number: EM869AA. HP L1940T Flat Panel Monitor. Overview

55 (54.6 viewable) Full HD Direct-lit LED Commercial Display CDE5502 Direct LED backlight technology for superior color performance

Optical Component Environmental Test System

OPTICAL POWER METER WITH SMART DETECTOR HEAD

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy)

InSight Pro. Valuable real-time process insight

Telephony Training Systems

Industrial Diode Laser (IDL) System IDL Series

2 MHz Lock-In Amplifier

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

PicoScope 6407 Digitizer

UNIIQA+ NBASE-T Monochrome CMOS LINE SCAN CAMERA

2013, 2014 Hewlett-Packard Development Company, L.P.

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

1. Opens, selects or exits the OSD menu. 4. Selects video input, DVI-I#1 or DVI-I#2.

Optoma DLP Projector

Retired. 1. Power On/Off Button 4.Minus (-) Button 2. Power Indicator LED 5.Menu Select Button 3. Plus (+) Button 6.

HDMI Over IP Extender Kit - 4K

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

TROJANUVTORRENTTM. Drinking Water Disinfection

GFT channel Time Interval Meter

Selection Table. Ordering Information

Datasheet. Shielded airmax Radio with Isolation Antenna. Model: IS-M5. Interchangeable Isolation Antenna Horn. All-Metal, Shielded Radio Base

XC-77 (EIA), XC-77CE (CCIR)

Microwave Counter, Power Meter and DVM in One Portable Package

QuickSpecs. Models Part Number: GF904AA. HP L inch LCD Monitor. Overview

STAR-07. Industrial Pattern Projection. System Architecture. System Control

SMART Board interactive whiteboard system Model 680i5

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Smart Laser cinema projectors. Reduced total cost of ownership, superior image quality

Transcription:

Advanced LED Illumination for Fluorescence Microscopy X-Cite XLED1 Resetting the standard for LED illumination Optimized excitation with high power LED illumination at the sample plane Instant switching between wavelengths; ideal for multi-color live cell imaging High-Speed automation with advanced internal pulse generation and external triggering options Ease of use through an optional interactive touch screen controller and intuitive user interface Flexible and scalable to allow you to tailor to specific applications

The X-Cite Advantage. Designed with researchers in mind, the X-Cite XLED1 combines high power excitation specificity with high-speed imaging capabilities for maximum control, versatility, flexibility and ease of use. Inspired by over 27 years of light applications expertise, X-Cite XLED1 is the superior choice in LED technology ideal for microscopy applications involving fast, automated multi-color live cell imaging. With the recent advancements in LED technology, researchers can benefit from the intrinsic advantages of LEDs: Reliability with long lifetimes Fast on/off switching with no warm-up required Elimination of frequent mercury and xenon lamp changes No need for mechanical shutters - prevents vibration and increases imaging speed Optimized excitation through narrow bandwidth and diverse wavelengths Reduced phototoxicity and bleaching Compact size, low heat generation, and energy efficiency Stability (spatial and temporal) Increased excitation specificity without the high cost of lasers What does X-Cite XLED1 offer? Uniform and stable, high-power LED illumination Narrow LED bandwidth that reduces crosstalk between fluorophores Efficient wavelength mixing for uniform and powerful illumination of up to four fluorophores at the sample plane Fast triggering both internally and externally with pulse duration as short as 10µs for advanced system control Instantaneous wavelength switching for fast multi-color imaging applications Ultra-fine control of intensity (0.1%) for precise adjustments to output power Ease of use for a novice or an expert microscopist Intuitive, intelligent GUI offering full system control via PC or optional touch screen controller Simple plug and play modules allowing fast and easy system reconfiguration Compatibility with third party software for simplified integration into existing experimental set-ups 20,000 hours (or 3 years) LED module guarantee

We foun flexible i fluoresce Holly Aaron, M X-Cite XLED1 represents the industry s next generation of LED illumination for fluorescence microscopy applications. The XLED1 includes user configurable high power LEDs with specific excitation modules ranging from 365-735nm to image from the most commonly used fluorophores to those used in niche applications. The X-Cite XLED1 offers superior power output and advanced control for high-speed automated fluorescence imaging. Harnessing the intrinsic advantages of solid-state LED technology, the X-Cite XLED1 provides unprecedented wavelength and power stability over extended lifetimes. Integrated with state-of-the-art technology that provides full control over LED intensity and signaling, the X-Cite XLED1 can trigger, or be triggered by, external hardware. By combining these features with an easy-to-use intelligent GUI or optional controller, the XLED1 offers maximum control with the convenience and versatility of an X-Cite. Maximum Power and Specificity for your Application The X-Cite XLED1 offers up to four high-powered LEDs with narrow spectral profiles that enable excitation specificity while maintaining high power at the peak excitation wavelength via efficient optics including optimized microscope adaptors. In certain applications, excitation filters may not be required, and the use of multi-band filters negates the need to rely on a filter wheel, thus enabling high-speed imaging. The X-Cite XLED1 is well-suited for applications including live cell imaging (high-speed or long-term), optogenetics and even fixed cell imaging involving fluorescent probes, conjugates and the ever-popular fluorescent proteins (FP s) along with the Normalized Spectra 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% Figure 1. LED Spectral Profiles 365nm 385nm 405nm 447nm 460nm 525nm 635nm 660nm 735nm standard Alexa, ATTO dyes and traditional DAPI, FITC, and Cy dyes. The XLED1 system maximizes excitation specificity to which laser users are accustomed, but without the high cost of lasers (Figure 1). Control Options The X-Cite XLED1 has been designed with an optional touchscreen controller featuring an intuitive interface for easy navigation and advanced system control (Figure 2). With a touch screen display, users have the ability to view LED and system status while ensuring peace of mind when exchanging modules. Advanced operators and lab managers can manage more complicated imaging protocols through the triggering screen (Figure 3). A unique virtual oscilloscope feature plots all programmed channel and trigger waveforms (Figure 4), ensuring proper system set-up, as well as potentially eliminating the need for external electrical or optical test equipment. A PC version of this GUI is also included with every X-Cite XLED1. For those who choose to control the system through their own software, a full SDK is available, as well as drivers for common software packages. Flexibility and Ease of Use The X-Cite XLED1 system allows operators to control the intensity of each LED in large steps through a slider, or through smaller steps using simple up and down arrows associated with each LED. With the touch of a button, intensity levels used from past experiments can be set via a numerical value of the required intensity. The XLED1 touch screen controller also offers the ability to save optimized settings for future experiments with up to five user profiles that are password protected. By simply logging in when starting an experiment and logging out at the end of the day, individual settings will be saved for future use. 0% 350 450 550 650 750 Wavelength (nm)

d the new XLED1 LED light source from Lumen Dynamics to be extremely n a multi-user environment, providing great excitation for all of our favorite nt proteins. We found the new XLED1 LED light source from Lumen Dynamics to be extremely flexible in a multi-user environment, providing great excitation for all of our favorite olecular Imaging Center, UC, Berkeley fluorescent proteins. Holly Aaron, Molecular Imaging Center, UC, Berkeley Ideal for Live Cell Imaging The X-Cite XLED1 system is ideal for single or multi-color live cell imaging including high-speed applications, long-term development imaging, protein activation and interactions (FRET) and the popular optogenetics techniques. With super-fine control of power intensity as little as 0.1% increments, users can fine tune the exact power required for optimal imaging. With instantaneous switching between wavelengths and ability to pulse each LED for a defined time period or continuously, the XLED1 system will allow you to image for long time periods while minimizing photobleaching and phototoxicity when compared to alternative light sources. Programmable for High-Speed Automated Imaging Designed with a sophisticated internal pulse generator, the X-Cite XLED1 allows full control of the LEDs according to experimental needs. Signals can also be directed into each or all of the LEDs through TTL inputs generated by external hardware connected to the XLED1. Timing protocols can be defined as per experimental design to turn each LED ON and OFF, as well as transmit trigger signals to peripherals (e.g. stages, cameras, electrophysiology rigs) connected to the XLED1. Configurable with Plug and Play Modules The X-Cite XLED1 can be configured specifically for each user s applications. Simply choose two or more LEDs and our online configurator will help you choose the dichroics required for the LED combination and help you determine the system for your needs. The XLED1 offers easy replacement of LEDs with additional modules that may be required for niche applications for greater flexibility. Just simply plug and play - no wires to reconnect and no need for special tools. Optical table visualization (Figure 5) on the maintenance screen provides researchers with useful system configuration information and also pinpoints the location and details of each LED source and dichroic, making reconfiguration straightforward. Setting the New Standard for LED Illumination X-Cite is recognized as the industry standard for fluorescence illumination and was the first to introduce a commercial replacement for traditional HBO systems in 2002. The X-Cite XLED1 represents a new generation of LED microscopy illuminators with optimum LED power where it is most essential at the sample while offering the convenience and ease of use researchers have come to expect from an X-Cite.

What X-Cite XLED1 offers High power at the sample plane (365nm - 735nm modules) Narrow LED bandwidth Instantaneous wavelength switching Fast ON/OFF Advanced triggering and pulsing options Configurable plug and play modules Optimized X-Cite adaptors Uniform and stable illumination Intuitive GUI and interactive touch screen Easy module exchange How researchers benefit. Increased spectrally targeted excitation power where it matters most to excite/ uncage/activate fluorophores at the sample High signal to noise ratio; reduces crosstalk between fluorophores leading to high signal specificity Enables fast multi-color image acquisition and pulsing applications (down to 10µs) Eliminates vibration and latency of mechanical shutters, allowing precise, short exposure times to limit photobleaching and phototoxicity Flexibility with experimental design and system control Easy configuration according to user application High efficiency coupling to a wide variety of microscopes currently available with X-Cite products Reliable and consistent image data Ease of use; no advanced training required GUI verifies system set-up and ensures worry-free module exchange 0.1% intensity control increments Repeatable illumination and optimal imaging Figure 2 Figure 3 Figure 4 Figure 5 XLED X-Cite XLED1 offers superior power output and advanced control for high-speed automated microscopy in LED fluorescence illumination. Designed with researchers in mind, the X-Cite XLED1 combines excitation specificity and high speed imaging capabilities for maximum control, versatility and ease of use. Recognized as the industry standard in fluorescence illumination, X-Cite offers the XLED1 as the next generation of advanced LED technology for microscopy applications.

SPECIFICATIONS X-Cite XLED1 package includes: X-Cite XLED1 illumination system, optional XLED1 touch screen controller, up to four modules, user manual (CD) with GUI and USB driver, quick start guide, liquid light guide, microscope adaptor, power cord, trigger cables, USB cable X-Cite XLED1 System Wavelengths: Dimensions: Weight: Wavelengths available at http://www.ldgi-xcite.com/downloads/misc/spectra.pdf 8.5 (W) x 8 (H) x 15 (D) (22cm x 20cm x 39cm) ~7.3kg, ~16lbs (full system) Supply: Universal input of 100-240Volts AC, 50-60Hz. Fused at 6.3A Connectivity: Triggering: Sync Out: Sync Out Phase Control: Switching Speed: USB type-b female Trigger Input BNC (TTL-compatible) Sync Output BNC (TTL-compatible) Internal/External User-defined per channel Global trigger input User-defined free-running or single shot pulse modes Internal triggering generated from internal pulse generator 10µs (min), up to 18 hours (max) Mapped echo of LED cycles on separate output pins Individual control of sync phase advance/retard (half of max cycle duration) Instantaneous Minimum Duty Cycle: 10µs X-Cite XLED1 Touch Screen Controller (Optional) Screen: Resolution: Display Viewing Area: External Dimensions: Program: Connectivity: Power: Certifications: Warranty: Medical/Industrial grade 7 TFT viewable diagonal. Resistive touch screen with 16:9 aspect ratio and LED backlight with adjustable intensity 800 x 480 pixels 6 (W) x 3.5 (H) (15cm x 9cm) 8 (W) x 2.5 (H) x 5.5 (D) (20cm x 7cm x 14cm) Lumen Dynamics proprietary graphical user interface ~2.5m connectorized power and data combo cable <10 watts CE Marked, Certified to IEC, Canadian and US standards, RoHS compliant X-Cite XLED1 System, XLED1 touch screen controller and XLED1 LED drivers: 12 months from shipping. LED modules: 20,000 hours or 3 years 2260 Argentia Road, Mississauga, Ontario, L5N 6H7 Canada www.ldgi-xcite.com Telephone: +1 905 821-2600 Toll Free (USA and Canada): +1 800 668-8752 Facsimile: +1 905 821-2055 X-Cite@LDGI.com Lumen Dynamics Group Inc. is certified under the globally recognized ISO 9001 Quality Management System and the ISO 14001 Environmental Management System. Our global customers can trust that Lumen Dynamics strives to be the best possible supplier in all aspects of our business. X-Cite is a registered trademark of Lumen Dynamics Group Inc. All rights reserved. Alexa is a registered trademark of Life Technologies corporation Images acquired using an XLED1 by Dr. Kavita Aswani, Senior Applications Scientist, Lumen Dynamics Lumen Dynamics has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Contact Lumen Dynamics for prices and availability or to obtain the phone number of your local Lumen Dynamics representative.