Patriots Theater at the War Memorial Technical Data

Similar documents
Technical Information

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

SHUBERT THEATER 247 College Street, New Haven, CT

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

THE MORTENSEN HALL. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Technical Specifications

Sandusky State Theatre Technical Specifications

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Technical Specifications

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Performing Arts Theatre

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

PRODUCTION INFORMATION

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Bloomington Center for the Performing Arts. Technical Specifications

NORTH CHARLESTON PERFORMING ARTS

Dale F. Halton Theater Technical Specifications

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

NORTH CHARLESTON PERFORMING ARTS

Concert Hall Technical Specifications

FOX THEATRE ST. LOUIS

TECHNICAL PACKAGE.

Technical Specifications

Palace Theatre 61 Atlantic Street Stamford, Connecticut

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Arcadia Performing Arts Center Technical Specifications and Information

TECHNICAL INFORMATION & SERVICES

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Technical Specifications. Taylor Little Theater

Camden Opera House Theater. Technical Information

Technical Specifications and Inventory Spring 2018

Concert Hall Technical Specifications

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

NORTH CHARLESTON PERFORMING ARTS

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Baker Hall Technical Information Package

SAINT ANSELM COLLEGE DANA CENTER

Technical Services and Specification

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Information

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Quick-Advance Fact Sheet

Technical Specifications

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Main Stage Technical Specs - Hall #2

Technical Specifications

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

General & Technical Specifications:

The Breen Center for the Performing Arts Saint Ignatius High School

Hard Rock Cafe Times Square Sound System Advance Sheet

UF Performing Arts - Curtis M. Phillips Center for the Performing Arts

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Technical Specifications

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Dr JOHN GALLAGHER CONCERT CHAMBER

General & Technical Specifications

THE WASHINGTON CENTER TECHNICAL INFORMATION (as of 9/16/16)

The Port Theatre Technical Specifications

Center Theater Technical Information 9/1/12

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

VENUE TECHNICAL REQUIREMENTS

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Jane Mallet Theatre Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

PARAMOUNT ARTS CENTER ASHLAND, KENTUCKY

Theater Technical Information

Paramount Theatre Production Recap

JOHN W.H. BASSETT THEATRE

The University of Arizona s Centennial Hall Technical Information

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

VICTORIA THEATRE DAYTON, OHIO TECHNICAL SUMMARY

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Technical Facilities Specifications Erling B. and Dorothy E. Hanson Auditorium West Delaware High School

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Marjorie S. Deane Little Theater

FIVE FLAGS THEATER SERVICES STATEMENT

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

NORTH CHARLESTON PERFORMING ARTS

SECREST AUDITORIUM TECHNICAL PACKAGE

STATE THEATRE 805 Hennepin Avenue Minneapolis, MN 55403

Facility Technical Information

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Production Advance Information

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

THEATRE TECH MANUAL. Location and Mailing Address: Irving Arts Center 3333 North MacArthur Suite 300 Irving, Texas 75062

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

STAGE ELECTRICAL 1 OF 1. - COMPANY SWITCH - SERVICE OPTIONS: - 3-Phase, 4-Wire, 208V Amps per Leg: Phase, 4-Wire, 208V

Transcription:

Patriots Theater at the War Memorial Technical Data Stage House Dimensions Proscenium Opening: 50-0 wide x 25-0 high Batten Travel: 48-10 Batten Length: 60-0 Stage depth: 26 smoke pocket to back wall Pit depth at centerline: 12-6 Smoke pocket to edge of pit: 4-6 Center line to off stage left: 36-0 Center line to off stage right: 43-0 Orchestra pit in up position: 48-0 wide x 12-0 deep Orchestra pit in travel: 15-0 deep House curtain operates S.R. (Guillotine) Pin rail stage right Legs & full stage blacks: 24-0 Loading Raised loading dock for two 48-0 trucks with levelers Interior freight elevator at dock level, capacity: 10,000 lbs. Cab size: 6 wide x 12 long x 7 high Exterior Gala Scenic lift at dock level, capacity: 14,000 lbs. Lift size: 6 wide x 12 long Stage level loading door at top of scenic lift: 6-0 wide x 10-0 high Electrics Power: (2) 400 amp 120/208 volts AC with female cam locks upstage left (1) 200 amp 120/208 volts AC mid stage left with female cam locks Outside truck tie-in 200 amp 120/208 volts AC in basement with mouse hole to outside with female cam locks George Washington Ballroom stage left 200 amp 120/208 volts AC with female cam locks Delaware River Room 60 amp 120/208 volts AC with female cam locks Follow spot booth 200 amp 120/208 volts AC with female cam locks

Dimmers 278 2.4 KW 4 6.0 KW Control ETC ION with focus remote and remote video monitors (See attached Rep Plot) FOH Positions No. of circuits distance @ center line to smoke pocket Far cove 24 78-0 Near cove 24 54-0 Balcony rail 12 60-0 L & R Box booms 12 each side 57-0 1 Electric 24 2 Electric 18 3 Electric 18 * Due to fire regulations, fog or haze cannot be used without management approval Lighting Instrument Inventory *Note: Instrument inventory and light plot subject to change. Please talk to Operations Manager for current information Number: Type Lamp 2 ETC 5 Source-Four HPL 575 watt 15 ETC 10 Source-Four HPL 575 watt 30 ETC 19 Source-Four HPL 575 watt 35 ETC 26 Source-Four HPL 575 watt 60 ETC 36 Source-Four HPL 575 watt 40 PAR 64 40: FFR (medium flood) 20: FFS (wide flood) 6 6-cell cyc. Ground row FDN 500 watt 25 3-circuit mini-strips EYC 75 watt/12 volt MR-16 12 3-circuit PAR 56 Strips/8 ft. PAR 56 medium floods 2 Strong Super Trouper 2K Xenon Accessories Number: Type 8 21 ft. booms 50 18" side-arms - 2 -

Light Plot *Note: Instrument inventory and light plot subject to change. Please talk to Operations Manager for current information - 3 -

Sound House Console: Yamaha CL5 House Mix Positions: Back of house orchestra seating level house right of center Visiting back of house, behind house mix position Monitor Console: Midas M32 Monitor Mix Position: House stage right, Visiting either stage left or stage right Speakers: Stereo Fills: Left & Right: 4- EAW KF-850 per side 2 up & 2 down Center Cluster: Loge: 2 EAW KF-650 Orchestra: 3 EAW KF-300 Balcony: Over Balcony: 3 EAW JF-260 Rear Balcony: 6 EAW JF-80 Under Balcony:3 EAW UB-42 Stage Lip: Front Fills: 6 EAW JF-80 On Stage: Monitors: 12 EAW SM 15 3 EAW SM 200 IH Side Fills 2 EAW KF-650: 1 per side 2 EAW SB-250: 1 per side Play Back/Record: 2 - TASCAM CD-401 1 - TASCAM DAT-DA 30 2 - TASCAM Cassette-112 1 - TASCAM CDRW-700 ) Processing: House: dbx Driverack 480 with remote control Monitor: dbx Driverack (sidefills), QSC (monitor wedges) Amplification: House: QSC & Crest Monitor: QSC Microphones: Shure, Neuman, AKG, EV, BSS, Whirlwind, Crown, Sennheiser, etc.. Shure U1 Wireless: Beta 87 handheld or WL183 lavalier (6 channels total) A complete list is available upon request. Intercom: Clear Com 4 channel with 8 belt packs & single muff headsets Telex Wireless 2 channel with 4 belt packs & single muff headsets (compatable with channels A & B of Clear Com) Paging: Dressing Room page from stage right Infra red hearing impaired system with120 headsets Full stage coverage 4 towers with doors onstage 4 ceiling panels Full stage with no color down lighting Concert Shell - 4 -

Hanging Plot (Top-View) - 5 -

Hanging Plot (Section) - 6 -

LINE SET SCHEDULE (11/04) *Note: Line Set Schedule subject to change. Please talk to Operations Manager for current information 40A 23-11 Cyclorama (Hemp Set) 40 23-5 Concert Shell Back Wall 39 22-11 Concert Lighting Strip 38A 22-5 (Hemp Set) 38 21-11 37 21-5 Concert Shell Ceiling 36 20-11 35 20-5 34 19-11 Legs 33 18-11 Border 32 18-5 Concert Lighting Strips 31 17'-11 30 17'-5" 29 16 11 28 16-5 #3 Electric 27 15-11 26 15-5 Concert Shell Ceiling 25 14-11 Legs 24 14-5 Border 23 13-11 22 13-5 21 12-11 20 12-5 Concert Lighting Strips 19 11-11 18 11'-5" 17 10-5 #2 Electric 16 9-11 15 9-5 Concert Shell Ceiling 14 8-11 13 8-5 Legs 12 7-11 Border 11 7-5 Stage Right Side Tab 10 6-11 9 6-5 Concert Lighting Strips 8 5-11 7 5-5 6 4-11 5 4-5 Legs 4 3-11 #1 Electric 3 3-5 Concert Shell Ceiling 2A 3-2 Legs (spotted) 2 2-11 Border 1 2-5 Stage Left Side Tab 0 DATUM LINE (back of proscenium) - 7 -

Notes: All Legs, border and electrics may be moved if required (and must be restored after the event). All concert shell-ceiling panels and the concert shell back wall cannot be moved. Concert electric strips may be used but if anything is required to be moved, it all must be restored. Wardrobe 1-25 x 38 room basement level adjacent to dressing rooms 2 washers and 2 dryers coin operated basement level 1 Clothing steamer 1- Iron and Ironing board 6- Wardrobe Hanging Racks Dressing Rooms Stage Level: Basement Level: #1-3 mirror spaces with private restroom #2-10 mirror spaces w/ sink #3-10 mirror spaces w/ sink #4-4 mirror spaces w/ sink #5-5 mirror spaces w/ sink 2 common restrooms 2 single showers #6-10 mirror spaces w/ sink #7-5 mirror spaces w/ sink #8-2 mirror spaces w/ private restroom - 8 -

Company and Stage Management A separate office is available on request. - 9 -

Contact phone numbers at the War Memorial Operations Manager Bill Nutter 609-943-9921 609-777-1872 Dressing Room 1 609-984-9267 Backstage: 609-984-9577 Administrative Office: 609-984-8484 Administrative Fax: 609-292-7636 Box Office: 609-984-8400 Union Stagehands: Steward: Union Business Agent: Local 8 IATSE Chris Day Tel: 856-905-6045 Michael Barnes Tel: 1-800-732-9335 - 10 -

Patriots Theater Stage Layout - 11 -

George Washington Ballroom Layout - 12 -