FAULT MAPPER PRO GRAPHICAL TDR CA7027. User Manual

Similar documents
USER GUIDE CX10/CX10+ Cable Length Expert. D Rev.B01

Snap ShotTM User Manual

DATA LOGGER MODEL L452 ENGLISH

VDV Scout Pro 2. VDV Scout Pro 2 LT. Instruction Manual VDV VDV ENGLISH VOICE, DATA, AND VIDEO CABLE TESTING

Time Domain Reflectometer Megger TDR900

CABLE FAULT LOCATOR MEGGER CFL510F (TDR1000/2)

Cable Prowler TM. User Manual. Full-Color Cable Testing and Report Management.

Cable Prowler TM. User Manual. Full-Color Cable Testing and Report Management

Dynatel Advanced Cable Locator 2250

True RMS AC/DC Mini Clamp Meter

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

ScopeMeter 190 Series Specifications

BASIC PH METER BASIC PH METER KIT

Users Manual. Stroboscope. September 2014

Platinum Tools Inc. All rights reserved. 5/12 Voice, Data, Video + Length GENERAL SPECIFICATIONS WARNINGS

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

LAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection

HD-CM HORIZON DIGITAL CABLE METER

TestifierPROf Test Set

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Instructions. P MHz 1X/10X Passive Probe

Metal Electrode Meter

BS36 Waveform TDR (Time Domain Reflectometry) Cable Fault Locator

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

Certificate of Calibration

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

DisplayPort Extender over 2 LC Fibers

DVI over Single CAT5 Series CV-117. DVI over Single CAT5 Direct Plug-in Extender. User Manual. Made in Taiwan

User Manual rev: Made in Taiwan

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

22" Touchscreen LED Monitor USER'S GUIDE

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

PLL2210MW LED Monitor

PL2410W LCD Monitor USER'S GUIDE.

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

INSTALLATION MANUAL. ST-CVTMD420-WPIR-W Covert Motion Detection Color Camera. v1.3 8/11/11 1

DisplayPort Extender over 2 LC Fibers

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

OFI Optical Fiber Identifier User s Guide

Owner s Manual. Backup Monitor System. LCD Monitor & CCD Color Camera

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

PLL1920M LED LCD Monitor

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

SyncGen. User s Manual

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

VGA & Audio over CAT5 Distribution Series

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

Digital Storage Oscilloscopes 2550 Series

SCALE & WEIGHT DISPLAYS

One (1) fiber Detachable HDMI Extender

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Passive DVI Extenders Over single Cat5/6/7 AT-DVI60SRS

INSTRUCTION MANUAL DAFM2

OM2000N INSTALLATION MANUAL

Multi-Channel Passive Transceiver Hubs Installation Sheet

LAN Network Tester LAN Network Tester

OWNER'S MANUAL MYCRO SUB

ST-4000D SIGNAL LEVEL METER

Winmate Communication INC.

Model UH-2C-3S 3-port HDMI UTP Extender

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Kramer Electronics, Ltd. USER MANUAL. Models: 622T, Dual Link DVI Optical Transmitter 622R, Dual Link DVI Optical Receiver

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Technical description and user manual. Survey Meter SM 8 D. Sensortechnik und Elektronik Pockau GmbH. Siedlungsstraße 5-7 D Pockau-Lengefeld

Electronic converter for level transmitters MT03L Instructions manual

The Phono Box SUMIKO Fifth Street Berkeley, CA sumikoaudio.com

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VA-100P-5. Power Supply

ALPHA Personal Priority Display User Manual

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19

PRO-CoaxExt HDMI extender over Coaxial cable with bi-directional IR User s Guide

ST-4000 SIGNAL LEVEL METER

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

PXL2760MW LED LCD Monitor

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

USER MANUAL Full HD Widescreen LED Monitor L215ADS

NI PXI/PXIe-2543 Specifications

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

By CHANNEL VISION. Flush Mount Amplifier A0350

LA1500R USER S GUIDE.

Audio. 4K Ultra HD Extender. w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK. User Manual. Release A2

NS-3 RF Noise Source Operation Manual

Transcription:

FAULT MAPPER PRO GRAPHICAL TDR CA7027 E N G L I S H User Manual

Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications. The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: Catalog #: 2127.83 Model #: CA7027 Please fill in the appropriate date as indicated: Date Received: Date Calibration Due: Chauvin Arnoux, Inc. d.b.a AEMC Instruments www.aemc.com

Table of Contents 1. INTRODUCTION... 2 1.1 International Electrical Symbols...2 1.2 Receiving Your Shipment...3 1.3 Ordering Information...3 1.3.1 Accessories and Replacement Parts...3 2. PRODUCT FEATURES... 4 2.1 Description...4 2.2 Key Features:...4 2.3 Fault Mapper Pro Features...5 3. SPECIFICATIONS... 6 3.1 Accuracy...7 4. OPERATION... 8 4.1 Principles of Operation...8 4.2 Accuracy and Velocity of Propagation (Vp)...8 4.3 Getting Started...9 4.4 Set-up Mode...9 4.5 Backlight...10 4.6 Tone Generator...10 4.7 Selecting Full Scale Sensitivity...11 4.8 Adjusting the Vp Value...11 4.9 Determining and Measuring Vp Values...11 4.10 Attaching a Cable to the Fault Mapper Pro...12 4.11 Testing a Cable...13 4.12 Single Shot and Continuous Scanning Modes...14 4.13 Typical Fault Displays...14 5. MAINTENANCE... 15 5.1 Changing the Battery...15 5.2 Cleaning...15 5.3 Storage...15 Repair and Calibration...16 Technical and Sales Assistance...16 Limited Warranty...17 Warranty Repairs...17

CHAPTER 1 INTRODUCTION Warning This instrument meets the safety requirements of IEC61010-1:1995. The Model CA7027 is designed for use on de-energized circuits only. Connection to line voltages will damage the instrument and could be hazardous to the operator. This instrument is protected against connection to telecom network voltages according to EN61326-1. Safety is the responsibility of the operator. 1.1 International Electrical Symbols Signifies that the instrument is protected by double or reinforced insulation. CAUTION - Risk of Danger! Indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument in all cases where this symbol is marked. Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous. Compliance with the Low Voltage & Electromagnetic Compatibility European directives (73/23/CEE & 89/336/CEE) In the European Union, this product is subject to a separate collection system for recycling electrical and electronic components In accordance with directive WEEE 2002/96/EC 2 Fault Mapper Pro Model CA7027

1.2 Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. 1.3 Ordering Information Fault Mapper Pro Model CA7027...Cat. #2127.84 Includes carrying case, 4mm color-coded banana plugs with alligator clips, 4x1.5V AA batteries, user manual and product warranty card. 1.3.1 Accessories and Replacement Parts Tone Receiver / Cable Tracer Model TR03...Cat. #2127.76 Lead - Replacement set of 2, Color-coded 4 ft (Red/Black), Test Probes & Alligator Clips...Cat. #2152.01 Fault Mapper Pro Model CA7027 3

CHAPTER 2 PRODUCT FEATURES 2.1 Description The Fault Mapper Pro is a hand-held graphical TDR (Time Domain Reflectometer) designed for identifying and locating faults on power and communication cables, given access to one end only. The Fault Mapper Pro measures cable length and indicates the length and distance to cable faults to a range of 9 ft (3 m) to 19,000 ft (6000m) on virtually any type of cable. It injects a series of pulses into the cable under test. The velocity at which the pulses travel is determined by the type of cable, which is known as the velocity of propagation (Vp) of the cable. The Velocity of Propagation (Vp) is adjustable between 1% and 99% enabling accurate calibration to the cable under test. The Vp value is expressed as a percentage of the speed of light (e.g. 67% or ft/mtrs/micro-second), this value will vary according to the type of cable under test. The Fault Mapper Pro can accept user selectable values between 1 and 99% (or the equivalent value in feet or meters per micro-second). Based on the selected Vp and the time taken for the pulses to travel through the cable, a reflection profile of the cable under test is displayed. An adjustable cursor assists in locating faults and termination. The Fault Mapper Pro incorporates an oscillating tone tracer, which is detectable with a standard tone tracer, for use in the tracing and identification of cable pairs. 2.2 Key Features: Hand-held graphical TDR (Time Domain Reflectometer) Measures cable length and indicates distance to faults to a range of 19,000 ft (6000m) Graphical LCD Easy identification of short range faults Emits an audible tone, used to trace and identify the type of fault 4 Fault Mapper Pro Model CA7027

2.3 Fault Mapper Pro Features 1 Graphical TDR 2 AEMC Instruments Fault Mapper Pro VX.X 3 6 4 7 TEST / TDR / 5 8 FAULT MAPPER PRO MODEL CA7027 1. Banana plug input (Red/Black) 2. Graphical LCD 3. Cable select and Vp (Velocity of Propagation) decrement button 4. Test/function select button 5. Backlight button 6. Cable select and Vp (Velocity of Propagation) increment button 7. Mode select button (TDR/Tone tracer) 8. Power ON/OFF button Fault Mapper Pro Model CA7027 5

CHAPTER 3 SPECIFICATIONS MODEL ELECTRICAL Ranges @ Vp=70% Range Selection Accuracy* Resolution Minimum Cable Length Sensitivity CA7027 23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 19000 ft Manual range control ±1% of range Approximately 1% of selected range 1.5 ft (0.5m) Minimum 3 pixel return on a fault at 4km on 0.6mm 0, PE, TP Vp (Velocity of Propagation) Adjustable from 1% to 99% Output Pulse Output Impedance Output Pulse Width Scan Rate: Tone Generator Voltage Protection Power Supply Battery Life Auto-off MECHANICAL Dimensions Weight (with battery) Display Resolution Display Backlight ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Altitude SAFETY Safety Rating Protection Degree Electro-Magnetic Compatibility CE Approved +5V peak to peak into an open circuit Selectable between 25, 50, 75 & 100Ω 3 ns to 3 ms, Automatic with range 2 scans / second or scan held Oscillating tone 810Hz to 1110Hz 250VAC 4 x 1.5V AA alkaline batteries 60 hours continuous scanning Selectable 1, 2, 3, 5 minutes or disabled 6.5 x 3.5 x 1.5" (165 x 90 x 37mm) 12oz (350g) 128 x 64 pixel Graphical LCD Electroluminescent 14 to 122 F (-10 to 50 C) -4 to 158 F (-20 to 70 C) 5 to 95% RH non-condensing 6000 ft (2000m) IEC61010-1; EN60950 6 Fault Mapper Pro Model CA7027 IP54 EN61326-1 Compliant with current EU directives *Measurement accuracy of ±1% assumes the instrument setting for velocity of propagation (Vp) of the cable under test to be accurately set, and homogeneity of the velocity of propagation (Vp) along the cable length. Accurate positioning of the cursor is also required. **Specifications are subject to change without notice.

3.1 Accuracy The CA7027 is able to measure distances to faults and cable lengths to an accuracy of ±1%. This measurement accuracy is based on the correct value of Vp being used for the cable under test, and homogeneity of the Vp along the cable length. If the Vp is set incorrectly by the operator, or the Vp varies along the length of the cable, then additional errors will be incurred and the measurement accuracy will be affected. NOTE: The Vp is less well defined with unshielded multicore cable, including power cable, and is lower when a cable is tightly wound on a drum than when installed. Fault Mapper Pro Model CA7027 7

CHAPTER 4 OPERATION 4.1 Principles of Operation The Fault Mapper Pro works by measuring the time taken for a signal to travel to the far end of the cable under test, or to an intermediate fault and return. The velocity at which the signal travels Vp (Velocity of Propagation) will depend on the characteristics of the cable. Based on the selected Vp and the measured travel time of the test pulse, the Fault Mapper Pro calculates and displays impedance anomalies and their distances along the cable. 4.2 Accuracy and Velocity of Propagation (Vp) The Fault Mapper Pro measures distances to faults and cable lengths to an accuracy of ±1%. This measurement accuracy is based upon the correct value of Vp being used for the cable under test, and homogeneity of the Vp along the cable length. If the Vp is set incorrectly by the operator, or the Vp varies along the length of the cable, then additional errors will be incurred and the measurement accuracy will be affected. See 4.8 for setting the Vp. NOTE: The Vp is less well defined with unshielded multi-conductor cable, including power cable, and is lower when a cable is tightly wound on a drum than when it is installed in a linear fashion. Correct measurement of fault distances is also dependent on the cursor being positioned accurately by the operator. When locating faults with the Fault Mapper Pro the cursor should be positioned at the beginning of the feature on the cable waveform as shown below. Vp=72% Z=100Ω 621ft 8 Fault Mapper Pro Model CA7027

4.3 Getting Started The instrument is switched on and off using the green power button, found on the lower right side of the front panel. When the unit is first switched on it will display the opening screen giving the software version, the currently selected Vp (Velocity of Propagation), cable impedance and battery status indicator. AEMC Instruments Fault Mapper Pro VX.X 4.4 Set-up Mode 1. Hold down the TDR / button, then press the TEST / button to enter set-up mode. > TDR Vp % VC Vp=67% T/P 100Ω Meters Contrast Shutdown : 1 Minute 2. The following options can be configured: TDR or Tone Generation Set Vp to % (1 to 99%) or speed in micro-seconds (see 4.8) Set cable impedance (Z) to 25, 50, 75 or 100Ω Twisted pair (T/P) Set measurement units to Feet or Meters Adjust the display contrast Disable/Enable Auto-off function 3. Press the TEST / button to move the line selector (>) down the screen. 4. Press the and buttons to change the setting of the line selected. 5. Press the TDR / button again to save changes and exit set-up mode. NOTE: When the Fault Mapper Pro is turned off, it will retain the current set-up parameters. Fault Mapper Pro Model CA7027 9

Upon completion of configuring the instrument, a test screen will appear displaying the following information: Vp Setting Impedance setting (Z) Range scale 7 meters Battery condition indicator Distance of cursor Cursor Output pulse Scan mode icon (indicating scan mode selected) 4.5 Backlight The LCD display is fitted with an electroluminescent backlight to enable easy viewing under a variety of different lighting conditions. The backlight is switched on and off with the button. 4.6 Tone Generator The Fault Mapper Pro may also be used as a tone generator, to trace and identify cables and wires. The user will need a cable tone tracer, such as the AEMC Tone Receiver/Cable Tracer Model TR03 (Cat. #2127.76) or equivalent. Pressing the TDR / button will inject a warbling (oscillating) tone into the cable or link under test. When set, the following will be displayed: * * * * * * * * * * * * * * * * * * * AEMC Instruments Fault Mapper Pro VX.X Warble Tone * * * * * * * * * * * * * * * * * * * The injected signal oscillates between 810 and 1110Hz, six times per second. 10 Fault Mapper Pro Model CA7027

NOTE: The auto-off function is disabled in Tone Generator mode, so that the tone can be injected into a cable for an extended period of time while tracing takes place. See 4.10 for attaching a cable to the Fault Mapper Pro 4.7 Selecting Full Scale Sensitivity The Fault Mapper Pro has 11 range scales covering the range of 1.5 to 19,000 ft (0.5 to 6000m). To select a range scale, or scan the cable run, press and hold down the TDR / button, then press the button to decrease the range or the button to increase the range. 4.8 Adjusting the Vp Value To adjust the Vp, press and hold the TDR / button and press the TEST / button to enter the setup mode. Release both buttons. Press the TEST / button until the pointer (>) is next to Vp. Next use the and buttons to adjust the Vp to scroll between v/2, M/Ms or Vp % UC. Press the TDR / button to exit the set up mode. 4.9 Determining and Measuring Vp Values Vp, or Velocity of Propagation, values are characteristic of each cable type and brand. The Vp is used to measure the length of a cable and to measure a fault location. The more accurate the Vp, the more accurate the measurement result will be. The cable manufacturer may list the Vp on their specification sheet or may be able to provide it when asked. Sometimes this value is not readily available, or the user may wish to determine it specifically to compensate for cable batch variations or for special cable applications. 1. Take a cable sample of exact length increments (ft or m) longer than 300 ft (100m). 2. Measure the exact length of the cable using a tape measure. Fault Mapper Pro Model CA7027 11

3. Connect one end of the cable to the Fault Mapper Pro. Leave the end unterminated and make sure the wires do not short to each other. 4. Measure the length and adjust the Vp until the exact length is displayed. 5. When the exact length is displayed, Vp is established. 4.10 Attaching a Cable to the Fault Mapper Pro WARNING: Make sure that there is no power supply or equipment attached to the cable to be tested. 1. Check that the far end of the cable is either open or shorted (not fitted with a resistive termination). 2. Attach the Fault Mapper Pro to one end of the cable to be tested. The cable attachment is via a banana plug input located at the top of the unit. For unterminated cables use the alligator clip attachment provided. Coaxial Cable: Connect the Red clip to the center wire and the Black clip to the shield/screen. Shielded Cable: Connect the Red clip to a wire adjacent to the shield and the Black clip to the shield. Twisted Pair: Separate out one pair and connect the red and black clips to the two wires of the pair. Multi-conductor Cable: Connect the clips to any two wires. Coaxial Cable Shielded Cable Twisted Pair Multi-conductor Cable 12 Fault Mapper Pro Model CA7027

4.11 Testing a Cable After setting the Vp value and cable impedance (Z) to match the tested cable, attach the Fault Mapper Pro to the cable, as described in 4.10. Press the TEST / button, to get to the test screen. Vp=72% Z=100Ω 413ft The following display shows a cable with impedance anomalies on it. Vp=72% Z=100Ω 210ft The vertical cursor line is moved left and right along the line of the trace by pressing the and buttons. To determine the distance to an event, position the cursor at the beginning of the event and read off the distance as shown below. Vp=72% Z=100Ω 413ft On the fault curve shown in the previous two screens, a low impedance event occurs at 210 ft, shown by a downward spike on the curve, and a high impedance event occurs at 413 ft. The open end of the cable is shown as a large positive spike This is used to determine the end (length) of the cable. Fault Mapper Pro Model CA7027 13

4.12 Single Shot and Continuous Scanning Modes When the Fault Mapper Pro is first switched on, it is set to Single Shot mode. In this mode, the Fault Mapper Pro only fires a pulse into the cable under test when either the and buttons or the TEST / button is pressed. Single Shot Mode: Saves on battery life and also enables the Fault Mapper Pro to be disconnected from the cable while still leaving the fault display on the screen. To enter Continuous Scanning mode press and hold down the TEST / button. The icon will appear at the bottom right of the display, when Continuous Scanning mode is active. Continuous Scanning Mode: Fires pulses into the cable under test at the rate of 6.7 pulses per second. In this mode the Fault Mapper Pro is able to more easily identify intermittent cable faults. 4.13 Typical Fault Displays The following table shows typical fault traces to assist you in the identification of faults using the CA7027: Type Vp Z Type Vp Z Cat5 STP 72 100 T/Pair Jelly PE 64 100 Cat5 UTP 70 100 T/Pair PE 67 100 Coax Air 98 50/75 T/Pair PTFE 71 100 Coax Air Space 94 50/75 T/Pair PVC 58 100 Coax Foam PE 82 50/75 T/Pair Paper 72nF 88 100 Coax Solid PE 67 50/75 T/Pair Paper 83nF 72 100 14 Fault Mapper Pro Model CA7027

CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. 5.1 Changing the Battery Disconnect the instrument from any cable or network link. 1. Turn the instrument OFF. 2. Loosen the 2 screws and remove the battery compartment cover. 3. Replace the batteries with 4 x 1.5V AA alkaline batteries, observing the polarities. 4. Reattach the battery compartment cover. 5.2 Cleaning Disconnect the instrument from any source of electricity. Use a soft cloth lightly dampened with soapy water. Rinse with a damp cloth and then dry with a dry cloth. Do not splash water directly on the instrument. Do not use alcohol, solvents or hydrocarbons. 5.3 Storage If the instrument is not used for a period of more than 60 days, it is recommended to remove the batteries and store them separately. Fault Mapper Pro Model CA7027 15

Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be scheduled back to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures. For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#). This will ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the outside of the shipping container. Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com (Or contact your authorized distributor) Costs for repair and standard calibration are available. NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. 16 Fault Mapper Pro Model CA7027

Limited Warranty The Model CA7027 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the Warranty Coverage Information with your records. What AEMC Instruments will do: If a malfunction occurs within the one-year period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC Instruments will, at its option, repair or replace the faulty material. REGISTER ONLINE AT: www.aemc.com Warranty Repairs What you must do to return an Instrument for Warranty Repair: First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our Service Department (see address below), then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to: Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. Fault Mapper Pro Model CA7027 17

01/12 99-MAN 100361 v2 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (603) 749-6434 Fax: (603) 742-2346 www.aemc.com