Sub-Synchronous PLACE Vibration FOR TITLE on Centrifugal Compressor with Tilt-Pad AUTHORS

Similar documents
Compressor rub verified by rotating phase symptoms

Pelletizer Motor Bearing Damage Detection Based on Vibration Data. John J. Yu Carl Feng Wang Tony Wei Zhou Nicolas Péton Haibo Lin Jun Quan

Machinery Diagnostic Plots Part 2 ORBIT Back-to-Basics: What does the data really tell us?

Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us?

Transient Vibration Analysis of Refinery Steam Turbines using Labview Program

Dramatic Vibration Improvement due to Ring-Section Pump Foundation Repair Based on ODS in a Power Plant

onitoring Bearing Vibration with Seismic Transducers

VIBRATION ANALYSIS AND BALANCE REPORT. Sample Facility

The above chart is used in ISO method to determine the alarm and trip limit for rotating machines equipped with rolling element bearings.

Reciprocating Machine Protection

Work no. 2. Doru TURCAN - dr.ing. SKF Romania Gabriel KRAFT - dr.ing. SKF Romania

Overall vibration, severity levels and crest factor plus 3 CF+ White Paper

Defense Technical Information Center Compilation Part Notice

The Turbomachinery Vibration Software

Overall vibration, severity levels and crest factor plus

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

Affected Products: Product Line Category Device Version Machinery Health Management. Data Analysis

An Introduction to Vibration Analysis Theory and Practice

System 1* Evolution - Part 2

Maintenance Strategies For Cost Reduction and Quality Improvement

Belt Faults. This paper looks at the vibrations produced by a bad belt.

Phase Analysis: the missing weapon

Bunch-by-bunch feedback and LLRF at ELSA

Form-wound Squirrel Cage Induction Motors 375 kw (500 Horsepower) and Larger API STANDARD 541 FIFTH EDITION, DECEMBER 2014

9070 Smart Vibration Meter Instruction Manual

Application Note Using Buffered Outputs and Patch Panels with the SETPOINT Machinery Protection System

HOW TO START A PREDICTIVE MAINTENANCE PROGRAM. Richard D. Hall. National Electrical Carbon Products

Digital BPMs and Orbit Feedback Systems

Online correlation of data quality and beamline/beam instabilities History and motivation 1.1 Symptoms

Analysis of WFS Measurements from first half of 2004

LabVIEWTM. Order Analysis Toolkit User Manual. LabVIEW Order Analysis Toolkit User Manual. July C-01

Robert J. Sayer, PE President, The Vibration Institute Oak Brook, IL, USA Owner, Applied Structural Dynamics Westerville, Ohio, USA

Eddy Current Probe System

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Processing for Improved Spectral Analysis

TOP-FLO Pump Sizing Application Data

Limitations of a Load Pull System

Operation Manual for. SCU1 Signal Conditioning Unit

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

MachineryMate 800 operating guide Handheld vibration meter

-1.1/49 0 C. 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 06TS**

Virtual Vibration Analyzer

3500/42M Proximitor * /Seismic Monitor Bently Nevada* Asset Condition Monitoring

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION

New Filling Pattern for SLS-FEMTO

The Effect of Time-Domain Interpolation on Response Spectral Calculations. David M. Boore

Vibration Measurement to Condition-Based Management Closing in on a Century of Continuous Progress

Series 8800 Radial Tip Fans Design 8812

3500/42E Vibration Monitor

Advanced Seed Monitoring

3500/72M Rod Position Monitor

3500/42M Proximitor * /Seismic Monitor Bently Nevada* Asset Condition Monitoring

CASE HISTORY#3 COOLING TOWER GEARBOX BEARING FAULT. Barry T. Cease Cease Industrial Consulting

1900/25 Vibration Monitor

Getting Started with the LabVIEW Sound and Vibration Toolkit

3500/42M Proximitor*/Seismic Monitor

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Immersion Pumps HCT (High Chem) sealless

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

COMMISSIONING OF THE ALBA FAST ORBIT FEEDBACK SYSTEM

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

ECE 402L APPLICATIONS OF ANALOG INTEGRATED CIRCUITS SPRING No labs meet this week. Course introduction & lab safety

Basic Specifications. Driver Model SD12B/15B SD20B SD30B SD30C SD40C SD50C SD75C

Application of cepstrum prewhitening on non-stationary signals

Laser measurements in the motor bearing diagnostics. Ariel Dzwonkowski 1, Leon Swędrowski 2

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Troubleshooting and Rectification of a Giant C 3 Splitter Tower Problem

ih Series Drypumps (505) idealvac.com idealvac.com

PEP-II longitudinal feedback and the low groupdelay. Dmitry Teytelman

Phase (deg) Phase (deg) Positive feedback, 317 ma. Negative feedback, 330 ma. jan2898/1638: beam pseudospectrum around 770*frev.

Table of Contents. Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES

BY ADRIAN MESSER, UE Systems, Inc.

DA E: Series of Narrowband or Wideband Distribution Amplifiers

EMI/EMC diagnostic and debugging

TROV TROUBLE SHOOTING GUIDE. A comprehensive trouble shooting guide for TROV

Agilent High Capacity RV Pumps & Roots Pumping Systems

EZ Encoder : Optical Incremental (P Series)

Condition Monitoring Program: A Need to Improve Performance of Machineries

THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays. Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image.

ANALYSING DIFFERENCES BETWEEN THE INPUT IMPEDANCES OF FIVE CLARINETS OF DIFFERENT MAKES

Series description: Wilo-Sub TWU 3 HS

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

800 Displaying Series Flowmeter

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Part-Turn Electric Multi-Turn Electric

ASK THE EXPERTS: Procedure for Verifying Magnetic Pickup Signal Integrity Using a Windrock Portable Analyzer

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

013-RD

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Acoustical Testing 1

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Results of Vibration Study for LCLS-II Construction in FEE, Hutch 3 LODCM and M3H 1

SPECIFICATION NO NOTE

Results of the June 2000 NICMOS+NCS EMI Test

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

REPORT DOCUMENTATION PAGE

White Paper Measuring and Optimizing Sound Systems: An introduction to JBL Smaart

ULTRALOW TEMPERATURE FREEZERS -86 C

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS

Transcription:

Sub-Synchronous PLACE Vibration FOR TITLE on Centrifugal Compressor with Tilt-Pad AUTHORS Bearings John J. Yu Nicholas Hanson

Author Biographies Dr. John J. Yu joined Bently Rotor Dynamics Research Corporation in 1998, followed by General Electric - Bently Nevada. Since 2002, he has been troubleshooting machinery vibration problems in the field directly, and is now Global Technical Leader for Machinery Diagnostic Services. He holds a PhD in Mechanical Engineering from University of Alberta, and is a fellow of ASME. Nicholas Hanson joined Flint Hills Resources as a Machinery Reliability Engineer in 2013. He has been working with rotating machinery in the Chemical and Oil & Gas industry for 10 years. He holds a degree in Mechanical Engineering from the University of Minnesota. 2

Abstract This presentation provides a success story that subsynchronous vibration was eliminated on a centrifugal compressor. The sub-synchronous vibration originally occurred at high operational speed on this 5-stage hydrogen recycle centrifugal compressor supported by tilt-pad bearings. Vibration data is reviewed to find its root-cause. Each possible malfunction is discussed to see if it was likely the root-cause. It is shown that sub-synchronous vibration not caused by surge or stall could still happen even with tilt-pad bearings. A solution was implemented to successfully resolve the issue. 3

1. Introduction Outline 2. Problem Statement 3. Vibration Data Review 4. Conclusion and Recommendation 5. Final Results 6. Lessons Learned 7. Most Recent Update 4

1. Introduction 5 5-stage hydrogen recycle centrifugal compressor Supported by 5-pad tilt bearings with LBP arrangement Maximum speed 8600 rpm Vibration monitored by X-Y pairs of proximity probes at all bearings, with site convention of looking from outboard to inboard of the compressor.

2. Problem Statement The compressor experienced high vibration of 2.5 mil pp with Sub-Synchronous Vibration (SSV) amplitude of 1.5 mil pp at frequency of 3000 cpm, at both inboard and outboard bearings. Very trivial level of SSV from steam turbine bearings. 1X filtered Direct or broadband 6

3.1 Vibration Data Review Waterfall plot 7 Vibration components: 1X and harmonics normal SSV at 3000 cpm abnormal from Compressor Inboard Bearing X-probe 3000 cpm 1X and low harmonics

3.2 Vibration Data Review Cascade plot 8 Characteristics of SSV: Not tracking with speed. Almost constant frequency of 3000 cpm, likely the lowest natural frequency. from Compressor Inboard Bearing X-probe 3000 cpm 1X

3.3 Vibration Data Review Operation condition When did SSV occur? At high speed that is also related to high horsepower. SSV was able to disappear at speed even higher than the onset speed. >0.1 mil pp @3000 cpm Ended at 7768 rpm (>7597rpm) Molecular weight decreased after SSV Started at lasted for a while but 7597 rpm before reducing speed. 9

10 3.4 Vibration Data Review Orbit and spectrum plots Shaft vibration: Varying orbit shapes due to combined SSV and 1X, etc. SSV level even higher than 1X as shown in spectrum plots Orbits at OB & IB Bearings Spectrum plots from X-probes at OB & IB Bearings

11 3.5 Vibration Data Review SSV orbits SSV ( 0.38X filtered at 7930 rpm) orbits at OB & IB Bearings SSV properties: Fairly circular orbits with forward precession. In-phase between IB and OB, indicative of the self-excited vibration with the 1 st mode.

12 4.1 Conclusion and Recommendation Root-causes: Oil whip? unlikely Tilt-pad bearings with narrow oil rings of 0.017 clearance. No hysteresis effect was observed on oil bearings as SSV ending speed was even higher than its beginning speed. Surge? definitely not now Surge occurred a few months ago that might affect aerodynamic stability, but no sign of surge right now. Misalignment? less likely Though shaft centerline plots are not available due to lack of startup/shutdown data, orbits look normal.

4.2 Conclusion and Recommendation Root-causes (cont.): Rub? not now Rub at natural frequency of 3000 cpm would be reverse processional (dry whip), but the current one is forward. Slight changes in 1X vibration were due to changes in speed. Bouncing type of rub would be at fractional frequency tracking with speed. Several loops in orbit were due to combined different frequencies, not contact. Aerodynamic instability from seals possible Current abradable seal clearances of 0.026-0.030, doubling the previous spec 0.013-0.015 diametral clearance. 13

4.3 Conclusion and Recommendation Root-causes (cont.): Aerodynamic instability from compressor impellers possible Destabilizing impeller forces exist, similar to turbines and pumps (Thomas-Alford forces), though less. It was reported that no SSA occurred at 8000 rpm with molecular weight of 2. Higher bearing clearance possible Previous bearings (0.004 diametral clearance) replaced with the current ones (L/D=1.6 /3.5, 0.0055 clearance) with self-aligning spherical contact surface, probably reducing their damping to cope with destabilizing forces from seals and impellers. 14

4.4 Conclusion and Recommendation 15 Therefore, the source of the instability might have come from the seals and impellers, not from the tiltpad bearings. However, the current higher bearing clearance might have reduced stability margin of the whole compressor-bearing system. A recommendation was made to reduce the bearing clearance.

16 4.5 Conclusion and Recommendation Changes made: Bearings were replaced with tighter clearance (reduced from 0.0055 to 0.0035 diametral, bearing preload increased from 0.27 to 0.53).

5.1 Final Vibration Results After replacing bearings 17 SSV virtually suppressed to zero at all operational conditions Cascade plot from Compressor IB X-probe

5.2 Final Vibration Results 18 The 1 st resonance increased from 3000 rpm to 3400 rpm Bode plots from compressor bearings

19 5.3 Final Vibration Results At 8566 rpm, overall vibration amplitude became < 0.3 mil pp at both IB and OB bearings, as the unit was operating near the antiresonance point. Orbits at OB & IB Bearings Spectrum plots from X-probes at OB & IB Bearings No SSV 1X No SSV 1X

5.4 Final Bearing Metal Temperatures 20 Bearing metal temperatures increased slightly (<10 F) due to reduction in bearing clearance, but not exceeding 180 F (alert limit being 240 F).

6. Lessons Learned Sub-synchronous vibration not caused by surge or stall could still happen even with tilt-pad bearings, because centrifugal compressor destabilizing forces always exist, such as those from seals and impellers to possibly make the unit rotordynamically unstable. Sometimes it is impossible to eliminate the sources of instability. However, since the stability margin is determined by overall rotorbearing system properties, modification of other parts in the field may resolve the issue. In this case, it seems that the overall stability margin could be enhanced by decreasing bearing clearances. The effective damping might still be increased by raising both stiffness and damping of the bearings. 21

22 7. Most Recent Update No sub-synchronous vibration has occurred since the changes in bearings in 2008. In 2012, shaft was stiffened, which raised the 1 st critical speed to about 3700 rpm.