Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

Similar documents
Operating Instructions BTX-1 Series Digital Band Tension Meter

Transmitter Interface Program

MS2540 Current Loop Receiver with RS485 Communication

Weighing Scale. 10key&12key User manual

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

SM-10 SAT Level Meter User s Manual

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

NS-3 RF Noise Source Operation Manual

SyncGen. User s Manual

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

ST-4000 SIGNAL LEVEL METER

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

ST-4000D SIGNAL LEVEL METER

PLL2210MW LED Monitor

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

22" Touchscreen LED Monitor USER'S GUIDE

16-CH Color Full Duplex Multiplexer Instruction Manual

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

LM-TV09-4K2K. 4K video wall controller. User. Manual

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

PL2410W LCD Monitor USER'S GUIDE.

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

USER MANUAL Full HD Widescreen LED Monitor L215ADS

LCD VALUE SERIES (32 inches)

USER MANUAL Full HD Widescreen LED Monitor L215IPS

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

DTV742 Installation Quick Start Guide

HD Digital Set-Top Box Quick Start Guide

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

USER MANUAL Full HD Widescreen LED Monitor L236VA

Quick Operation Guide of LTN7700/7600 Series NVR

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Introduction...2. Features...2 Safety Precautions...2. Installation...4

LA1500R USER S GUIDE.

aorun manual V2.0 MARCH 2018

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

DMX LED light effect with 4 lenses

Color TFT LCD Monitor The Art of Surveillance

SCALE & WEIGHT DISPLAYS

Noise Detector ND-1 Operating Manual

User Guide. HDMI Active Cable Extender. DVI-7370c

OMEGA SERIES COUNTING SCALE

HD Digital MPEG2 Encoder / QAM Modulator

TVAC20000 User manual

Operating Instructions

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

Digital Terrestrial Alignment & Installation Meter

MP 35" Zero-G 100Hz Curved Monitor with AMD FreeSync 2.0

COLOR TFT LCD MONITOR. Manual

Evolution Digital HD Set-Top Box Important Safety Instructions

P-2 Installing the monitor (continued) Carry out as necessary

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

PXL2470MW LED LCD Monitor

DH551C/DH550C/DL550C Double Sided Display User Manual

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Manual. Simrad IS80 Heading Repeater HR80. English

OPERATING INSTRUCTIONS TOM-0431IP

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

PLL2710W LED LCD Monitor

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

PX1710M LCD Monitor USER S GUIDE

CT12A USER INSTRUCTION MANUAL BARFIELD M/N CT12A. Doc. P/N: Revision F November 7, 2014 BARFIELD, INC.

MT03A Electronic converter for flow rate transmitters

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19

TABLE OF CONTENTS. Instructions:

2013, 2014 Hewlett-Packard Development Company, L.P.

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

CONTENTS 8 ACCESSORIES 13 9 TROUBLE SHOOTING AND ADVICE SPECIFICATIONS BATTERY USAGE CAUTION 13

Colour Explosion Proof Video Camera USER MANUAL VID-C

ASSEMBLY AND CALIBRATION

Electronic converter for level transmitters MT03L Instructions manual

OPTICAL POWER METER WITH SMART DETECTOR HEAD

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

RIGOL. 快速指南 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL Technologies, Inc. All Rights Reserved.

Dell D3218HN. User s Guide. Regulatory model: D3218HNo

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

IMPORTANT SAFETY INSTRUCTIONS

Controller, Scheduler-Timer Model UCS-01. User Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Sprite TL Quick Start Guide

LVP602S LED Video Processor USER S MANUAL

Camera 220C Document Camera User s Guide

Transcription:

733 S. Bowen Street Longmont, CO 80501 USA Phone: (303) 702-1980 Fax: (303) 702-1982 E-mail: sales@tensitron.com Web Site: www.tensitron.com Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

Step 2: Next you will be prompted ENTER WEIGHT 1. Using the or arrows select a minimum tension value. (Do not use zero.) Press ENTER. INDEX PAGE NO. Accuracy, How to Check 12 Analog Output (Option)... 4,7 Audio. 3 Backlighting... 3 Batteries, Charging. 2 Calibrations, Custom.. 4,16 Calibration, Naming...4 Contrast / Backlighting... 3 Data Logging.. 6 Display/Refresh Rates...3 Features 11 Flow Chart.. 8-9 Memory Function....2 Quick Start Instructions..2 Safety and Maintenance 1 Selecting Cable Size..2 Serial Communications (Option)...4 Standard Instruments.7 Tension Units...2 Zeroing. 2,13 Select increasing weight values for WEIGHT 2 THRU 4 (No. 4 being the maximum weight value). At each weight number select your weight value using the and arrows. ENTER each selection. Next you will calibrate the instrument to the weight values you just selected. To simulate tension loads for calibration, take a sample length of your material and suspend it from above. (See Page 12, Fig. 1) Next hang weights from your material in the weight values you previously selected in enter weights 1 through 4. Your instrument will now prompt you PLACE WEIGHT 0. With zero tension applied to the instrument press ENTER. Next you will be prompted PLACE WEIGHT 1. Suspend the exact weight value from your material that you previously selected. Engage instrument to the tensioned material and then press ENTER. Next suspend weight value 2 from your material, engage the instrument to your tensioned material and press ENTER. Repeat procedure for steps 3 and 4. Once you have entered the value for WEIGHT 4 you have finished the calibration and will be returned to the Main Display. The Main Display will now indicate the description of the calibration you just entered. This signifies you have now selected the calibration you just performed. To change calibration use the or arrows until you reach SELECT MATERIAL. Follow procedures outlined in Section 3.6. Page 17

PERFORMING A 5-POINT LINEARIZATION CALIBRATION If you only wish to verify that the calibration you ve selected is accurate, go to the How To Check Accuracy section on page 12. Before beginning this procedure, verify that your cable is within tolerance and not out of round. For optimum accuracy use weights traceable to National Standards. (See Page 12 for instructions.) KEEP IT SIMPLE. Only simulate tensions using free-hanging weights on correctly-sized cables. Never use any device that attempts to convert rotational torque values into tension loads, as these types of systems are highly inaccurate. * When calibrating instruments use lb weights values only. Note: If your standards are in kg, convert their values into lb. ( 1 kg = 2.2046 lb ) Step 1: From the Main Display press or arrows until you reach Setup. Press ENTER. Press the arrow button until you reach Cal Tension. Press ENTER. The screen will display: Setup, Calibrate Tension, Enter Password. Contact Tensitron at service@tensitron.com for the password. Now the screen will display Setup, Calibrate Tension and you will be able to scroll down the list to select the description that you want to use for the new calibration.* When this new description is highlighted, press ENTER. * Note: If your cable description is not in this list, press ESC and go to Section 4:7 for the procedure to enter a new name, then start Step 1 again. Sec 1. SAFETY AND MAINTENANCE. WARNING: When using cordless, electronic instruments, always follow basic safety precautions to reduce the risk of fire, electric shock and personal injury. READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE. Before use, ensure all users read and understand this manual, as well as any labels packaged with or attached to the instrument. 1. KNOW YOUR INSTRUMENT. Read this manual carefully to learn your tension meter s applications and limitations, as well as the potential hazards associated with this type of instrument. 2. AVOID DANGEROUS ENVIRONMENTS. Do not use your instrument in the presence of explosive atmospheres (gaseous fumes, dust or flammable materials). Do not submerge your instrument in liquids. 3. USE THE RIGHT TOOL OR INSTRUMENT. Do not use this instrument to do a job for which it is not recommended. 4. CHECK FOR DAMAGED PARTS. Inspect instrument before use. Check for any binding of moving parts, improper mountings, broken parts and any other condition that may affect operation. Do not use a damaged instrument. Tag damaged instrument DO NOT USE until repaired. If meter has been dropped or otherwise damaged, return it Tensitron for repair. 5. GUARD AGAINST ELECTRIC SHOCK when connecting power supply to voltage source. 6. MAINTAIN INSTRUMENT CAREFULLY. Protect meter frm exposure to water. Keep instrument dry, clean and free from oil and grease. Do not lubricate. All roller bearings are sealed. 7. DO NOT USE INSTRUMENT IF it has received a sharp blow, been dropped or damaged in any way. Do not disassemble. Incorrect reassembly may result in the risk of electric shock, fire or exposure to battery fluids. If instrument is damaged return it to Tensitron for repair. 8. STANDARD POWER SUPPLY IS RATED FOR 100-240 VAC and includes several blades allowing use with European, US, Australian and other plug configurations. 9. DO NOT USE INSTRUMENT WHEN TEMPERATURE is below 35 F or above 115 F. Charging in direct sunlight or near a heat source will not produce a full charge and may permanently damage battery pack. 10. STORE INSTRUMENT AND CHARGER in a cool, dry place. Do not store where temperatures may exceed 120 F or fall below 35 F for storage times less than one month. Never let LCD display or battery pack assembly freeze. 11. WARNING: Only use battery pack assemblies provided by Tensitron with your meter (P/N: Battery, ACX). Other types of batteries may leak or explode, causing personal or property damage if charged in this device. 12. TO CHECK THIS METER S ACCURACY, see Check Accuracy on page 12. If meter is out of calibration, return it to Tensitron for repair. 13. TENSITRON RECOMMENDS CALIBRATION by the manufacturer at oneyear intervals, or sooner if the meter is worn, damaged, or reading incorrectly. However, it is the responsibility of the user to establish a suitable calibration interval, considering such factors as the user s accuracy requirements, requirements set by contract or regulation, and environmental factors such as frequency and conditions of the meter s use. Page 16 Page 1

Sec. 2. CHARGING INSTRUMENT BATTERIES. 1. Use only a Tensitron power supply to avoid damage to instrument. Connect power supply cable to instrument. 2. Plug the power supply into a 100 240 VAC outlet. 3. Fully charge battery prior to first use (approximately eight hours). 4. Battery pack assembly cannot be overcharged, however instrument will remain on while plugged into power supply. 5. Fully charged battery assemblies will operate approximately six hours +/- 20% depending upon usage and backlighting intensity. 6. Battery charge level is indicated in upper, right-hand corner of display. Sec. 3. OPERATION: QUICK START. 1. TURN UNIT ON by pressing ON button. Display shows: Tension (LBS, Newtons, or Kilograms), Cable size selected and battery charge level. 2. MEMORY FUNCTION. Depress the MEMORY button to store and display up to five separate tension readings, plus the average (AVG) of these stored values. 3. MOVE BETWEEN SCREENS by pressing either the or arrows. To make, or enter a selection, depress the ENTER key. To exit a setting, depress the ESCAPE key. 4. ZERO THE INSTRUMENT before taking readings by holding the instrument in the attitude in which it will be used, and with no load applied press the button marked ZERO. 5. READING OF TENSION. Variations in materials and sizes affect tension readings. It is essential to select the correct material and size from the calibration menu before use, or values may be incorrect. 6. SELECT MATERIAL. From the Main Display (first screen seen when unit is turned on) use the or keys until SELECT MATERIAL is displayed. Press ENTER. Next toggle through the various selections using the or arrows until correct cable size is highlighted, and press ENTER to make your selection. If your specific material is not listed, follow the calibration instructions included at the end of these instructions, or send a sample and the instrument to Tensitron for a custom calibration. 7. SELECTING TENSION UNITS IN lb, kg or dan. Press the or keys until TENSION UNITS is displayed. Press ENTER. Next, select: LBS, Kilograms or Decanewtons and ENTER selection. 8. ENGAGE INSTRUMENT TO TENSIONED MATERIAL. For best accuracy hold the instrument in the attitude the measurement will be taken in and press ZERO. Push closure bar away from the instrument handle to raise the outer cable guides. Engage the tensioned material by routing the cable so that it falls under the outer cable guides and over the center, contact point. Squeeze the closure bar shut until it locks into position beside the handle, and note the tension reading. (See photo on Page 14.) Page 2 Verify the tension value. For example, if your suspended weight is 41.0 lb your instrument should also indicate 41.0 lb +/- 5.0 lb once properly engaged to the cable. This procedure confirms the instrument s accuracy and it is now ready for use. Note: Full-scale accuracy is +/- 2% for all menu selectable calibrations. Accuracy for custom calibrations is material specific. For an instrument with a full-scale range of 250 lb this translates into +/- 5.0 lb, and for an instrument with a full-scale range of 500 lb, accuracy is +/- 10.0 lb. * Should you have additional questions, please contact Tensitron to speak with an applications engineer. Page 15

Sec. 4. ADDITIONAL TECHNICAL INFORMATION. Proper Engagement of Instrument to Cable: Push the closure bar away from the instrument handle to raise the outer cable guides. Then engage the instrument so that the tensioned cable is routed under the outer cable guides and over the center contact point. Squeeze the closure bar shut until it locks into position beside the handle, and note the tension reading on the display. In this example the tension is 1. SPEEDING UP OR SLOWING DOWN DISPLAY LCD REFRESH RATES - DAMPENING ADJUSTMENT. To either speed up or slow down the rate at which tension values refresh on the display, use the or keys, select SETUP, and press ENTER. Next select Dampening and after entering this selection, choose the refresh rate from: 1Hz, 2Hz or 5Hz. When new rate is highlighted, press ENTER. 2. AUDIO. Turn on or off audio beep (with key inputs) by selecting: SETUP, then select Audio, and finally either select ON or OFF. 3. BACKLIGHTING INTENSITY. Increase or decrease backlighting intensity by selecting: SETUP, then BACKLIGHT, and finally intensity level. 4. DISPLAY CONTRAST. Increase or decrease LCD display contrast by selecting: SETUP, then select CONTRAST, and finally manipulate contrast using the or keys. Remember to ENTER your new setting. Fig 3, Proper Engagement FOR BEST RESULTS ALWAYS TAKE SEVERAL READINGS OF THE CABLE TENSION BY DISENGAGING AND THEN REENGAGING THE INSTRUMENT FROM THE CABLE ITSELF. 5. VERSION. Instrument Model No. along with software version information can be viewed under SETUP and then selecting Version. 6. CUSTOM CALIBRATIONS. Calibrations are password-protected to prevent unintended changes. See Page 16 for step-by-step instructions, or contact your Metrology Department or Tensitron for assistance. If you only want to verify your instrument s accuracy refer to: How To Check Accuracy, on Page 12. Page 14 Page 3

Section 4 (Con t.) 7. CUSTOM CALIBRATION NAMES. Custom Calibrations (listed as Custom 0-9) can be renamed so that the Main Display indicates your name for the calibration instead of Custom 1, 2, etc. From the Main Display use the and keys until SETUP is selected. Press ENTER. Using the and keys select Custom Names. Press ENTER. Next, using the and arrows select calibration number, or previous name you wish to rename. Press ENTER. Using the and keys select the number, letter or character for the beginning of your new name. Press ENTER. Follow the same procedure for each sequential letter or space of your new description. Continue pressing ENTER until all spaces in the description have entered values. Once your new name has been entered you will be returned to the SETUP screen. To select your new calibration follow the procedures outlined in Sec.3.6. NEVER SIMULATE TENSION LOADS ON THESE INSTRUMENTS BY USING A CALIBRATION BAR! Doing so could damage the instrument to the point of failure. 8. MONITORING TENSION THROUGH THE ANALOG OUTPUT. (Optional feature) Output values are: 0 5 VDC or 4 20 ma. Connect Analog Output Cable to receptacle located on the bottom side of instrument. Connect output cable leads to the analog input of your measurement or control device. The RED lead is Voltage +, the WHITE lead is ma, and the BLACK lead is ground. From the main display use the and keys until you reach SETUP. Press ENTER. Next using the and arrows select ANALOG OUTPUT. Press ENTER. Using the and arrows select from: ANALOG TENSION CURRENT or ANALOG TENSION VOLTAGE. Once correct selection is made press ENTER. 9. CALIBRATION OF ANALOG OUTPUT. (Optional feature) From Main Display press the and keys until you reach SETUP. Press ENTER. Press the and keys until you reach CALIBRATE ANALOG. Press ENTER. Using the and keys adjust display to show the value at which the instrument reads maximum current or voltage. Press ENTER. 10. SERIAL DATA COLLECTION (RS-232 option). (Optional feature) Instruments outfitted with the optional RS-232 feature (designated with an E in the part number) support serial communications as follows: a. The baud rate is 9600 with no parity bit, 8 data bits and 1 stop bit (9600 8N1). b. Serial communications will work with most PCs with a cable up to 15 feet long. Fig 2, Confirming Cable Selection * Confirm that the size cable you re working with is the same size selected in your ACX s display. (In this example we re checking 1/8 aircraft cable.) Fig 2. Before engaging the ACX instrument onto the cable, hold it in the same attitude you ll be taking the readings in and press the Enter or Zero button. This will eliminate any small tare effect created by gravity. Page 4 Page 13

How to check the accuracy of an ACX-Series Digital Aircraft Cable Tension Meter To verify the accuracy of your instrument, tension a sample length of cable by suspending known weights from the opposite end. Fig 1. When performing this test use a micrometer to ensure your cable diameter is dimensionally within tolerance, +/-.003 of size, and not out of round. Section 4 (Con t) c. Setting the dampening rate on the instrument to 1 Hz + Serial, 2 Hz + Serial or 5 Hz + Serial will cause the instrument to output the tension values at a rate of once, twice or five times per second, respectively. The dampening rate can be set by going to the SETUP menu, selecting DAMPENING, adjusting the value of the dampening rate with the and buttons and then pressing the ENTER button. d. The units output serially will be the same units that are selected in the Tension Units menu. The currently selected tension units (such as lb, kg or N) are also displayed on the main tension screen. e. Perform the following steps in order to log serial data from the instrument using Hyper Terminal on a PC and put it into a Microsoft Excel spreadsheet: Standard Aircraft Cables CWT Aircraft Cables 1/16 =.0625 5-CWT =.076 3/32 =.0938 10-CWT =.106 1/8 =.1250 15-CWT =.141 5/32 =.1562 20-CWT =.155 3/16 =.1875 25-CWT =.170 7/32 =.2188 * Only use free-hanging weights which are traceable to National Standards on correctlysized cables. * Never use any tensioning device that attempts to convert rotational torque values into tension loads, as these types of systems are highly inaccurate. 1) Ensure that the dampening rate is set to 1 Hz + Serial, 2 Hz + Serial or 5 Hz + Serial. 2) Connect the serial cable from the instrument to a serial port on your PC. 3) Go to the Windows Start Menu and choose Programs- >Accessories->Communications->Hyper Terminal 4) In the Connection Description dialog box that pops up, type in a name for the new connection (you can use any name you wish to describe this file) and press the OK button. 5) In the Connect To dialog box that pops up next, go to the drop down menu labeled Connect Using: and select the serial port you connected the cable to in step 2. It is most likely that you are connected to COM1. 6) In the COMx Properties dialog box that pops up next, set the Bits per second: to 9600, the Data bits: to 8, the Parity: to None, the Stop bits: to 1 and the Flow Control: to None. 7) Click the Apply button and then click the OK button. 8) You should now see tension values appearing in the Hyper Terminal window. 9) When you are finished collecting data, close Hyper Terminal. 10) To save the data in Microsoft Excel format, use Microsoft Excel to open the file you saved the data log in and save it as an Excel file. Fig 1, Simulating Cable Tension Page 12 Page 5

Section 4 (Con t.) 11. DATA LOGGING. (Optional feature) From the Main display use the or keys until Data Logging is displayed. Press ENTER. Next, select Logging Rate and select Hz rate at which your data will be collected in (choices are from 1Hz to 100Hz). Next select Duration and select the time period the data will be collected over by using the or keys. Finally select Begin Logging when you are ready to collect your data. Note: You can stop collecting data at any time by simply depressing ESC (escape). Collected data will remain in memory, regardless if instrument is turned off, and will only be overwritten once new data is collected. To view collected data select View Data Log and press ENTER. Logged Data can also be uploaded to your computer via the RS-232, serial port. Refer to Sec 4.12, Uploading logged data, for specific instructions. FEATURES Large, easy to read, graphic display with adjustable backlighting and contrast. Display shows Tension, Battery Charge Level, and Cable Size selected. Push the MEMORY button to activate the Memory Function to store and display up to five separate tension readings plus the average value (AVG) of these stored readings. Select tension value to indicate either in lb, kg or dan. Accuracy is +/- 2% full-scale for all menu-selectable calibrations. Accuracy for custom calibrations is material specific. Up to ten calibrations can be programmed into the instrument. (All calibrations are password protected to provide due diligence against unauthorized changes.) Adjustable LCD refresh rates allow for stable digital readings. All models are typically available from stock. All models are factory calibrated and ready for use. Includes easy to use, cable diameter gage to accurately determine correct cable size. All calibration values are traceable to National Standards. Calibration certificate is included. 12. UPLOADING LOGGED DATA via RS-232, SERIAL COMMUNI- CATIONS. (Optional Feature) a. Refer to the previous section, Sec. 4.10, Serial Data Collection (RS-232 option) and configure communication protocols as outlined. Note: Step c has no effect on transferring stored data and can be adjusted to any setting. b. To retrieve or upload logged data from the instrument, send a lower case d. c. Collected data will remain in memory, regardless if instrument is turned off, until overwritten with new data. Cable Diameter Gage Page 6 Page 11

STANDARD INSTRUMENTS Model Range Resolution Standard Cable Selections ACX-100 5-100 lb 0.5 lb 1/16", 3/32", 1/8", 5/32" ACX-250 20-250 lb 0.5 lb 1/16", 3/32", 1/8", 5/32", 3/16" ACX-500 40-500 lb 1.0 lb 3/32", 1/8", 5/32", 3/16" ACX-CWT 20-250 lb 0.5 lb CWT-5, CWT-10, CWT-15, CWT-20, CWT-25 ACX-CMB 20-250 lb 0.5 lb 1/16", 3/32", 1/8", 5/32", 3/16", CWT-5 to CWT-25 ACX-1200-SCB 50-1200 lb 5 lb 3/16" ACX-250-M 20-250 lb 0.5 lb 2.0 mm, 2.5 mm, 3.5 mm, 4.0 mm ACX-100, ACX-250, ACX-CWT, and ACX-CMB AVAILABLE OPTIONS FOR ALL INSTRUMENTS - A Analog Output option. 0-5 VDC or 4-20 ma with Software-definable ending sequences. Provided with 10 cable. Data outputted at 40 Hz. - E RS-232 Serial Output option. Provided with 10 cable to Interface with your receiving device. Select data sampling rate from 1, 2 or 5 Hz. - D Data Logging option. Capture and play back data within a userdefined time window. Select the time window, then select the sampling rate (adjustable from 1-100 Hz). After capturing the data, review the data on the instrument s display or upload it using the 10 serial interface cable. SPECIFICATIONS: Approximate weight is 1-1/2 lb (weight varies depending upon instrument configuration). Re-chargeable NIMH battery with power supply provided. Approximately 6 hours of operation per battery charge depending upon backlighting intensity. Power Supply operates with input voltages from 100 240V and includes several interchangeable blades allowing use with European, US, Australian, and other plug configurations. Instruments may be operated continuously while connected to power supply. Durable, lightweight carrying case with protective foam inserts. ACX-500 and ACX-1200-SCB Page 10 Instruments can be configured with any or all of these options. ACX-500 Page 7

FLOW CHART Model: ACX-SERIES DIGITAL TENSION METER 0.0 LBS 1/8 Cable 1. 2. 3. 4. 5. AVG Use and and keys to navigate main screens Press ENTER button to reach sub screens, and and keys to make selections. Select Material 1/16 Cable 3/32 Cable 1/8 Cable 5/32 Cable 3/16 Cable 5 CWT 10 CWT 15 CWT 20 CWT 25 CWT Custom 9 Tension Units Kilograms Decanewtons LBS Data Logging (Optional) Logging Duration Begin Logging View Data Setup Dampening Custom Names Resolution Re-Calibrate Tension Audio Backlight Contrast Settings Version Select: 1 Hz 2 Hz 5 Hz Select: Custom 1..9 Enter: Password Select: Beep On Beep Off Select: Off Half Intensity Full Intensity Press or to Adjust Contrast Model: Page 8 Page 9