STED, on the SP5WLL. Wellcome on the STED Tutorial

Similar documents
Indiana Center for Biological Microscopy. Zeiss LSM-510. Confocal Microscope

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Quick Start Guide. Multidimensional Imaging

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Standard Operating Procedure of nanoir2-s

Confocal Application Notes Vol. 2 May 2004

Preparing for remote data collection at NE-CAT

Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology

CONFOCAL MICROSCOPE. Instrument Details: Make: Zeiss. Modal: LSM 700. Specifications: Microscopes

Update Records. Scanning Update Records

Release Notes for LAS AF version 1.8.0

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

2.1. Log on to the TUMI system (you cannot proceed further until this is done).

NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER

Building Your Own 2-Photon Microscope: Challenges, Advantages and Limitations

TransitHound Cellphone Detector User Manual Version 1.3

Measurement of Microdisplays at NPL

The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

Mosaic. Mosaic Real Time Parallel Illumination of Multiple Regions. Features and Benefits. DMD Technology. Specifications Summary

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

SEM- EDS Instruction Manual

Digital SWIR Scanning Laser Doppler Vibrometer

LSR II Users Guide Stanford Shared FACS Facility

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

Raptor University. Raptor System Kiosk Training. Instructor: RAPTOR TECHNOLOGIES, LLC

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

TT AFM LongBeach Procedures and Protocols V2.1

Digital SWIR Scanning Laser Doppler Vibrometer

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

User Guide. Best Seat Help Desk 24 hours a day/7 days a week

Robarts Research Institute at the Western University London, Ontario, Canada

Screen investigations for low energetic electron beams at PITZ

PulseCounter Neutron & Gamma Spectrometry Software Manual

Quick Guide Book of Sending and receiving card

Test Records. Scanning Test Records. This document provides a step-by-step tutorial on how to scan Test Records and verify the imported information.

PHI 5000 VersaProbe TM Operator s Guide

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

GVD-120 Galvano Controller

Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer

Reflecta Super 8 Scanner. User Manual

LHC Beam Instrumentation Further Discussion

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

LedSet User s Manual V Official website: 1 /

XI'AN NOVASTAR TECH CO., LTD

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

WA-7000 Multi-line Wavemeter OPERATING MANUAL

Network Disk Recorder WJ-ND200

Mini Micro Pulse Lidar System

Specifications LED Display Video Controller VX4. Xi an NovaStar Tech Co., Ltd. Rev1.0.4 NS

Transmitter Interface Program

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Using the Agilent for Single Crystal Work

Specifications LED Display Video Controller VX4S

CytoFLEX Flow Cytometer Quick Start Guide

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION

Specifications. Video Controller VX4U. Xi an NovaStar Tech Co., Ltd.

HIGH DEFINITION MONITOR HDM 5049 PLUS USER S MANUAL

ValuNet Android ManageMyTVs Application User Guide

CI-218 / CI-303 / CI430

Part 1 Basic Operation

VIDEO GRABBER. DisplayPort. User Manual

Virtual Vibration Analyzer

Characterization of Diamond Samples CHESS Run Summer 2013

WINDOWS GUIDE LIBRESTREAM.COM

Android ManageMyTVs Application User Guide Version 3.0

111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK

Linrad On-Screen Controls K1JT

Projector Management Application Version 7.00 Instruction Guide

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Electron Beam Technology

Scanning Entry Records Entry Records 1) Tools Menu Scanning Wizard 2) Using Scanner Hardware Contro 3) Entry Front Side 1

NOTES ON FACSCalibur USE AND TROUBLESHOOTING PROCEDURES. Department of Immunology Monash University 14/12/07

User Manual OVP Raman

SCode V3.5.1 (SP-601 and MP-6010) Digital Video Network Surveillance System

SCode V3.5.1 (SP-501 and MP-9200) Digital Video Network Surveillance System

User s Manual. Network Board. Model No. WJ-HDB502

SPATIAL LIGHT MODULATORS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TracQ Basic. Spectroscopy Software v6.5. User's Manual

Dektak Step by Step Instructions:

Connection for filtered air

FRQM-2 Frequency Counter & RF Multimeter

Getting Started with the LabVIEW Sound and Vibration Toolkit

PASS. Professional Audience Safety System. User Manual. Pangolin Laser Systems. November 2O12

Electrical connection

ManageMyTVs App for AndroidTM

CFlow User Guide. Science is hard. Flow cytometry should be easy.

ON-THE-FLY SCANS FOR FAST TOMOGRAPHY AT LNLS IMAGING BEAMLINE. Gabriel B. Z. L. Moreno X-Ray Imaging Beamline Group, LNLS

16-BIT LOAD CELL/DUAL STATUS INPUT

HV/PHA Adjustment (PB) Part

Operation and Installation Guide

MTS/T-BERD 8000 Platform

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010

Checking the fluids of the cart

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Digital Storage Oscilloscopes 2550 Series

Transcription:

STED, on the SP5WLL. Wellcome on the STED Tutorial Before using the Sp5 WLL STED microscope, you will need to put down your name on the reservation system = https://sv-bbs.epfl.ch/ptbiop/ Version 1 27.08.2013 1

System start Up. (Page 3-8) Laser switch and calibration (page 11-13) Sted configuration(page 14-17) System shut down. (page 18-22) 2

System Start up (step 1) On the STED Tower, Switch ON the button 3

System Start up (step 2) The SHG led turns green for 3sec, then it s turns orange for 3 minutes, then it s turns green again after 1 minutes. 4

System Start up (step 3) Turn the key from the depletion laser 592-nm to vertical position. The SHG led turns green. 5

System Start up (step 4) Push the PC/Microscope button Push the Scanner Power button. Push the Laser Power button (White laser is on ). Turn the Key on the right position (Argon laser is on ). 6

System Start up (step 5) Turn on the XCite Light. 7

System Start up (step 6) When the computer is on Introduce your Username Introduce your Password Introduce your login Start the LASAF software. Under Configuration select Machine STED. Do OK 8

Choosing the objective Under Acquire and Acquisition Choose and select your objective in the list. To acquire a STED image you need to use the HCX PL APO CS 100x 1.40 OIL 9

Choosing the Filter You need to introduice a Notch filter to block the laser 592nm Select Analyzer Filter Deselect Auto Select Select NF STED filter 10

Laser Switch 1 Under Configuration select 2times the 592 depletion laser Be sure the Laser Enabled led appears white (on the STED tower). 11

Laser Switch 2 Under Hardware Configuration and Laser select the WLL and Argon Laser. Increase the power of the 592 Depletion laser to 75% ( minimum) 100%. Increase the wll laser to 70% ( good value = the laser is very stable). Increase the Argon laser to 30%. 12

Laser calibration/alignement Every time that you want to use the STED, you need to allign the 592 laser vs WLL laser. Go to the STED Setting dialogue and press the Align Beams fonction. Wait until the calibration is finish. Press OK. 13

Conventional configuration By using the depletion laser 592nm, the samples can be bleach very quickly, so first scan the sample in standard Confocal mode to find the focus and prepare the STED configuration close to work. Set the WLL laser line that you need to use (10 to 30 %). Select the Hyd 2 detector and set it, to 100%. Set the Hyd bandwidth. Its start must be 10nm bigger than the WLL excitation line used and its end must not exceed 582nm. Use a format like 512x512 or 1024x1024. Use a scan speed like 400HRZ. Use a zoom factor from 4 to 6. 14

STED configuration ( step1) Select the STED mode. Set the WLL laser line that you need to use ( for ex. 488nm at 30 % to 50% transmission ). Select the Hyd 2 detector and set it to 100%. Introduce to the Hyd a bandwidth that is 10nm fahter to the WLL line that you set, and maximum 10nm lower than the wavelength of the laser depletion ( +/-582nm). Open the Gate Setting; set the Wll value which is equal to the value you use to excite the fluorochrome (for ex 488nm) Set the Gate Start from 0,5 to 2,5 1,5 a compromise Set the Gate End to 6,5 15

STED configuration (step2) Use a format like 1024x1024 to 2048x2048. Use a scan speed like 200 to 400HRZ. Use a zoom factor from 4 to 6. Very important,control that the pixel size is 20nm or less. Use 3-4 Accu in frame mode. Use 0-4 average in line mode. Ex. if you use 200 HRZ, use 2 3 accu without average. If you use 400 HRZ use 2-3 accu with 2-4 average. 16

STED configuration (step3) Select Switch Conventionel Laser. Select the STED. Set the Depletion 592nm laser line at 100% You can use less than 100%, but you may lost some resolution, and win some intesity. Use Start and not live to acquire the image. 17

System Shut Down (step 1) Before you exit from the software.please clean the objective. Turn off the 3 lasers 18

System Shut Down (step 2) Exit from the LASAF software. Go to Start and shut down the computer. 19

System Shut Down (step 3) Turn on the XCite Light. 20

System Shut Down (step 4) Turn the Key on the left position (Argon laser is off ). Turn off the Laser Power button (White laser is off ). Turn off the Scanner Power button Turn off the PC/Microscope button 21

System Shut Down (step 5) On the STED Tower, turn the Key vertical position Switch off the button 22