TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

Similar documents
HS-509 VIBRATION TRIP MODULE

Model IQ4-PC User Manual Revision Date:

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Operating instructions Electronic preset counter Type series 717

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Automation Interface Requirements for J602 Basic I/O Interface of a DPC 4 Welding System

SERIES 400 SERIES 620

SIGNET 5500 Flow Monitor ENGLISH

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Exercise 4-2. Counting of Actuator Cycles EXERCISE OBJECTIVE & & &

Luminaire installation box Surface-mounted box Ceiling installation box

Single Axis Position Controller

1900/25 Vibration Monitor

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

Operating Instructions

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

263 Series LED Bargraph Indicator and Controllers

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Operating Instructions for Throttle Valves Using VRC Valve Positioner

ProVu PD6000 Process Meter

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

16-BIT LOAD CELL/DUAL STATUS INPUT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Photoelectrics Through-beam Type PA18C.T..., DC

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

48x24. Options ORDER NUMBER OF TYPE PFL B

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Capacitive sensor BCT5-S18-UP6X2T-H1151

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

EZ Encoder : Optical Incremental (P Series)

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Omega.com TM. DPS3100 & DPS3200 series Programmable Scanners

APPLICATIONS. Automatic warehouse. Trasportation lines

Solid-State Digital Timer

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Solution Selection Guide

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

Smart-Encoder : Optical Incremental

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Technical data. General specifications. Indicators/operating means

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

T775U Series 2000 Electronic Stand-Alone Controller

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Electrical connection

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Operating instructions Through-beam sensor. OJ51xx / / 2004

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Standard signal metering in wall-mounting case

Digital differential Pressure switch Model DPS Instruction manual

DIGITAL TIMER - MODES- rev. 5.5

VIVO-D203(M) Quick installation and programming guide. Elements of the complete installation

OPERATION AND MAINTENANCE

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Pressure sensors with display

Signet Chlorine Transmitter

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Owner s Manual & 1802-EPD (Electronic Programmable Directory) Telephone Entry Systems

Innovative Air Systems ABN When Calling For Support Quote:.doc

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Modular Lube Lubrication Systems System Controls

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

02/11/2015

SAUTER flexotron RDT405 Manual

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

Multifunction devices

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

DVZ. Compact Vortex Flowmeter. for Low Viscosity Liquids

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

COUNTER - TOTALIZER TACHOMETER - TOTALIZER FREQUENCY METER CHRONOMETER INSTRUCTION MANUAL DM4500F

Assembly. Front view. LEDs. Parametrization interface. Power Bus

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Electrical connection

KNX Dimmer RGBW - User Manual

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

NEO-DYN 801P5 SMART SWITCH TM INSTALLATION AND OPERATION MANUAL. PN Rev D ECO 71349

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Ambiflex MF620 USER GUIDE

Standard RS232 RS ma

A summary of all menu lines available in self-diagnostic mode is shown below.

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Sentinel I24 Digital Input and Output Configuration

Revision 1.2d

The UK sequence is shown below. The duration of each phase can be easily adjusted during the programming to suit.

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Transcription:

TDEPD Field-Programmable Pressure Switch/Transducer with Integrated LED Display Programming Sequence Manual

Wiring Diagram Pin5 Maintenance Mode + Gray Vent Pin2 Digital Output 2 +/ Analog Output + White Pin1 10.5-28 VDC Power Supply + Brown Pin3 Common Blue Pin4 Digital Output 1 + Black Note: Any wires that are not electrically connected should be capped off with a small wire nut to prevent potential electrical shorts.

TDEPD Field-Programmable Pressure Switch/Transducer with Integrated LED Display Programming Sequence Manual Definitions PB1 = Press the #1 button briefly PB2 = Press the #2 button briefly PB1 for x = Press and hold the #1 button for x seconds PB2 for x = Press and hold the #2 button for x seconds Press BOTH for x = Press and hold both buttons at the same time for x seconds NOTE: After 30 seconds of inactivity on the pushbuttons, the TDEPD will automatically return to normal mode displaying pressure. Digit Placement 1 2 In sections of the manual that refer to setting a value or setpoint, first, second, digits, etc. are referenced as in the following diagram: 1

INNOVATIVE FOR INDUSTRIAL View/Program Sensor Characteristics Press BOTH for 3 seconds to enter programming mode Function: Places user in programming mode 1 2 NOTE: Programming parameters follow the sequence below. In order to return to a previous parameter, allow for 30 seconds of inactivity to return to normal mode and begin sequence again by pressing BOTH for 3 seconds to enter programming mode, beginning with step 1. ORIENTATION OF DISPLAY 1: Function: Change orientation of display (right-side up or upside down) Display OriE PB2 to alternate between right-side up and upside down PB1 to save change and move to next parameter Changes will ONLY be saved by PB1 and moving to the next parameter. If the TDEPD times out before PB1, changes will NOT be saved. 2

SENSORS AND HOME AUTOMATION POSITION OF DISPLAY 2: Function: Change position of display Display POSI PB2 to move position one digit NOTE: PB2 moves the position 1 place to the right around the unit. It does not move to the left. To move further left, use PB2 to circle the unit to the right to the desired place. TYPE OF OUTPUT 3: Function: Change the type of output for Digital Output 1 Display the current output type: 1nPn or 1PnP [250 ma max for (PNP) or 200 ma max for (NPN)] PB2 to change type 3

INNOVATIVE FOR INDUSTRIAL FUNCTION OF OUTPUT 4: Function: Change the function of Digital Output #1 Display the current output function: 1 no or 1 nc (normally open or normally closed) PB2 to change type LOW SETPOINT COLOR 5: Function: Change the display color when the pressure is below the lower setpoint Display 1 lo in the desired color (red or green) PB2 to change color 4

SENSORS AND HOME AUTOMATION SET LOW SETPOINT 6: Function: Change the lower setpoint (default setting is 10% of full pressure range) Display: Flash between 1 LS and the actual setpoint PB2 to enter change setpoint mode PB2 to change the first digit +1 (9 + 1 cycles back to 0) PB2 for 3 seconds and release to move to the next digit. (On release, active digit will blink on and off) - Next digit after thousands cycles back to ones. NOTE: Setpoint defaults to minimum 5 psi for units 100 psi or less and 10% of configured pressure range above 100 psi. For example, a unit configured for 250 psi will have a minimum set point of 25 psi. 5

INNOVATIVE FOR INDUSTRIAL HIGH SETPOINT COLOR 7: Function: Change the display color when the pressure is above the higher setpoint Display 1 hi in the desired color (red or green) PB2 to change color SET HIGH SETPOINT 8: Function: Change the higher setpoint (default setting is 90% of full pressure range) Display: Flash between 1 HS and the actual setpoint PB2 to enter change setpoint mode PB2 to change the first digit PB2 for 3 seconds and release to move to the next digit. (On release, active digit will blink on and off) - Next digit after thousands cycles back to ones. NOTE: Setpoint defaults to minimum 5 psi for units 100 psi or less and 10% of configured pressure range above 100 psi. For example, a unit configured for 250 psi will have a minimum set point of 25 psi. 6

SENSORS AND HOME AUTOMATION OPTION: If Digital Output 2 is present (TDEPD2), repeat Steps #3, 4, 6 & 8 for this output. [250 ma max for (PNP) or 200 ma max for (NPN)] NOTE: All instructions will be identical in Steps #3, 4, 6, & 8, but the initial number on the display will be 2 instead of 1. For example: OPTION: If the Analog Output is present (TDEPD3), continue to perform Steps #9 through #11. If no Analog Output is available, sequence will forward to Step #12. 7

INNOVATIVE FOR INDUSTRIAL PROGRAM ANALOG OUTPUT 9: Function: Program the type of analog output (voltage or current) Display: volt for voltage or Curr for current PB2 to change the type of analog output 10: Function: Program the analog output value at the minimum pressure Display: Flash between A Lo and the actual value PB2 to enter change value mode PB2 and release to change the digit. (On release, active digit will blink on and off) PB2 for 3 seconds to move to the next digit 8

SENSORS AND HOME AUTOMATION 11: Function: Program the analog output value at the maximum pressure Display: Flash between A Hi and the actual value PB2 to enter change value mode PB2 and release to change the first digit. (On release, active digit will blink on and off) PB2 for 3 seconds to move to the next digit 9

INNOVATIVE FOR INDUSTRIAL SET DISPLAY SPIN FUNCTION 12: Function: Program whether the display rotates continuously Display: nosp (if the display doesn t rotate or SPin if the display rotates continuously) PB2 to change whether the display rotates or not PB1 to save change and return to normal mode NOTE: If set to SPIN, upon re-entering programming sequence, active digits on display will revert to Step #2 setting for POSI(tion) for ease of programming. NOTE: After 30 seconds of inactivity on the pushbuttons, the TDEPD will automatically return to normal mode displaying pressure. NOTE: Missing any steps or requiring a change to any steps in the sequence can be remedied by allowing for inactivity, returning to normal mode, and re-entering the programming sequence beginning at Step #1 to make the necessary changes. 10

SENSORS AND HOME AUTOMATION Additional Functions PB1 for 10 sec. Function: Spike Counter. PB2 for 10 sec. You will see how many pressure spikes that spike counter #1 saw that were 1.2x and above the rated pressure. This number will rotate around the display one time (GREEN). Then you will see how many pressure spikes that spike counter #2 saw that were 2x and above the rated pressure. This number will rotate around the display one time (GREEN). Finally you will see the maximum pressure spike seen in psi. This will rotate around the display one time (RED). These numbers cannot be reset in the field. Return to Transducers Direct for reset. Function: Zero/Tare Display Press button #2 for 10 sec. If the pressure reading on the display is between -14.7 and 128 psi, the display will change to zero (0). If pressure is above 128 psi, display will not change. Minimum/Lowest Setpoint 5 psi for units 100 psi or less 10% of configured pressure range above 100 psi 11

INNOVATIVE FOR INDUSTRIAL Setpoint Information By setting the HIGH and LOW set points, you are saving the points at which the digital output(s) is activated and deactivated thusly creating the hysteresis between the two. Setting normally open and normally closed is based on the state of the digital output at zero pressure. Pressure (psi) In this example, normally open (no) has been selected. The digital output is active or on when the pressure reaches 60psi and deactivated or off at 30psi. OFF ON OFF ON OFF 60 psi ON High Set Point #1 (1 HS) 30 psi OFF Low Set Point #1 (1 LS) Time Maintenance Mode Maintenance Mode on the TDEPD is a digital output (pin 5 / gray wire) that activates if there is a half bridge failure on the unit typically due to pressure spikes or high shock or vibration. The TDEPD will still function but the digital output signal is to notify the user that the unit should be replaced before the other half bridge fails. The user should address any spike or high shock & vibration issues in the system at that time. 12

SENSORS AND HOME AUTOMATION Example Wiring Diagram for Digital Outputs (1).NPN OUTPUT TYPE 5 4 3 2 1 5 pin M12 cable Gray - Maintenance Mode + Black - Digital Out 1 Blue - DC power - White - Digital Out 2 Brown - DC power supply + DC 24V RELAY - COM DC +24V + N.O RELAY-SPDT N.C DC 24V RELAY - COM + N.O RELAY-SPDT N.C (2).PNP OUTPUT TYPE 5 4 3 2 1 5 pin M12 cable Gray - Maintenance Mode + Back - Digital Out 1 Blue - DC power - White - Digital Out 2 Brown - DC power supply + DC 24V RELAY - COM DC +24V + N.O RELAY-SPDT N.C DC 24V RELAY - COM + N.O RELAY-SPDT N.C 13

Transducers Direct, LLC 12115 Ellington Court Cincinnati, OH 45249 P 513-583-9491 F 513-583-9476 sales@transducersdirect.com www.transducersdirect.com REV. 10.18