THE XZIEX INDUSTRIAL / COMMERCIAL ATMOSPHERIC WATER GENERATOR SYSTEMS Technical Specifications

Similar documents
Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

Thermo Scientific Merlin Recirculating Chillers

Cooling systems for ORBIMAT

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Agilent High Capacity RV Pumps & Roots Pumping Systems

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Split System Air Conditioner

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

P Output Ratings. Dimensions and Weights. Prime Rating

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P1350P1/P1500E1 50Hz

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

Series description: Wilo-Jet HWJ

Powermax Selection Guide

Ultra Quiet Series Electric Air Handler

MAKING MODERN LIVING POSSIBLE. Bi-flow filter driers, DMB/DCB. Flare connection. Solder connection (copper) Technical Brochure

TWIN-PUMP. Dual line system. Designed to work all the day, every day in extreme condition and difficult environments

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

80G1 PRODUCT SPECIFICATIONS GAS FURNACE SINGLE STAGE CONFIGURATIONS HEAT EXCHANGER DESIGN CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

User Manual Digital Stroboscope

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Optical Cryostat - Omniplex TM

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

DM 50 / DM / 2- component dosing and mixing system. engineering

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

Model KBF 115 Constant climate chambers with large temperature / humidity range

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

-1.1/49 0 C. 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 06TS**

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Series. Processes TIG (GTAW) MIG (GMAW) Plasma Cutting Resistance Welding. Coolmate V3. Coolant systems are warranted for 1 year, parts and labor.

Technical Specifications

GENESIS Indoor Air Conditioners

MultiZone reverse cycle systems

Product Data Sheet 4656 EZ

Product Data Sheet 4656 ZW

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Product Data Sheet 8506 VW-691

ih Series Drypumps (505) idealvac.com idealvac.com

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

A801D PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE INSTALLATION FEATURES


Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

DENTAL LABORATORY EQUIPMENT

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Stage Wash 7x 10W LED Moving Head (RGBW)

Model KBF 1020 Constant climate chambers with large temperature / humidity range

800 Displaying Series Flowmeter

PRIMEROYAL Series. Metering Pump. Model PN

Technical Specifications

OTHER FEATURES UNIQUE FEATURES

Technical Specifications

If you have questions or problems in providing anything described as Customer

THE MODERN HVAC SYSTEM. J. Michael Carson P.E. Senior Mechanical Engineer Purdue University

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

CLINICAL SOLUTIONS THE TECHNOLOGICAL ADVANTAGE FOR DENTAL CLINICS AND UNIVERSITIES

KEMPPI K5 WELDING EQUIPMENT. Kempact Pulse 3000 QUALITY, SPEED AND PRODUCTIVITY

THE ULTIMATE DRY CHOICE

INSTALLATION REQUIREMENTS - THERMAL ANALYSIS & RHEOLOGY SYSTEMS

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

Air Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed

Electrical Services. The MCCA offers a variety of electrical services through our experienced in-house team of electricians.

Optical Cryostat - Economy

GENESIS Indoor Air Conditioners

CME500 SERVICE PARTS

T +31 (0) F

HOBO H Energy Logger

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

Elcometer Circular Ball Type. Drying Time Recorder. Operating Instructions

PCR AUTOMATIC HEAT TREATMENT CONSOLE

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

OLD WORLD AUDIO U33A VARI-MU STEREO COMPRESSOR INSTALLATION AND OPERATING NOTES

Fluid Cooling P-BAR b Industrial BOL Series

Küba comfort DP. Draught-free ventilation and extremely quiet operation

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

User Manual. Digital Stroboscope Tachometer. Model and Model

Features. Specifications. Finish. Notes

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

New Eppendorf Freezers Sample security meets the latest in energy efficiency. Stay Cool. CryoCube ULT Freezers: Efficiency has a new name

Transcription:

THE XZIEX INDUSTRIAL / COMMERCIAL ATMOSPHERIC WATER GENERATOR SYSTEMS Technical Specifications

The XZIEX Industrial/Commercial Atmospheric Water Generators We have 16 different models ranging in capacity and sizes to fit all your water needs. In addition to producing purified drinking water, all the IWS models can be simultaneously used as a: Climate Control System (Air Conditioning) Central Air Purifier Humidity Level Controller This is the technical specifications sheet of the XZIEX water generators. For product information, please refer to the presentation slides

Retail Sales Sell a Xziex ELITE Water Atmospheric Water Generator Generators $2,495 Retail $2,120.75 with 15% IBO discount OVERVIEW: earn up to 30% bonus. For a Grand Total up to $700.00 for each Generator sold at Retail. (Must hit monthly qualifier)

An Overview of Our Water Generators: Products that only produce water. 50/60 Hz Models XZIEX-25-60 XZIEX-50-60 XZIEX-60-60 XZIEX-75-60 XZIEX-100-60 XZIEX-150-60 Gallons / Day 530 1,080 1,300 1,620 2,055 3,350 Liters / Day 2,008 4,088 4,921 6,132 7,788 12,680 Pow er kwh 31 63 77 94 131 190 Dimensions LxWxH (in.) 219 x 80 x 70 219 x 96 x 102 219 x 81 x 72 249 x 96 x 102 249 x 96 x 102 341 x 127 x 133 Dimensions LxWxH (m) 5.6 x 2 x 1.8 5.6 x 2.5 x 2.6 5.6 x 2 x 1.8 6.3 x 2.4 x 2.6 6.3 x 2.4 x 2.6 8.7 x 3.2 x 3.4 Weight +/- 10% 6,000 7,250 5,400 8,400 9,625 14,410 Performance based on entering air conditions of 85 F (29 C) and 70% RH. The HCU models utilize Desiccant Wheel

An Overview of Our Water Generators: Products that produce water and supply cool, dry air. 50/60 Hz Models Po Gallo Liter wer Dimension ns / s / kw s LxWxH Day Day h 188 (in.) x 80 x XZIEX-25-50-A 560 2,120 32 219 70 x 96 x XZIEX-50-50-A 1,135 4,296 65 249102 x 96 x XZIEX-75-50-A 1,700 6,435 96 311102 x 96 x XZIEX-100-50-A 2,230 13,13 8,441 134 556102 x 96 x XZIEX-150-50-A 3,470 4 195 102 XZIEX-HCUb1004 83 314 7 80 109 x 42 x 55 x 44 x XZIEX-HCUb2008 169 602 15 62 XZIEX-HCUb2010 200 757 17 109 112 x55 x 66 x 62 x XZIEX-HCUc3012 231 875 19 127 57 x 66 x XZIEX-HCUc4016 303 1,147 20 127 72 x 66 x XZIEX-HCUc4020 380 1,438 23 173 72 x 96 x XZIEX-HCUc6030 XZIEX-HCUc8040 599 813 2,270 3,081 32 40 249 72 x 96 x 86 Dimension s LxWxH (m) 4.8 5.6 x x 22.4 x 1.8 x 6.3 x 2.62.4 x 7.9 x 2.62.4 x 14.12.6 x 2.4 x 2.6 2 x 1 x 1.2 3 x 1.5 x 1.6 32.8 x 1.5 x 1.7 x 1.6 x 3.2 x 1.41.7 x 3.2 x 1.81.7 x 4.4 x 1.82.4 x 6.3 x 1.82.4 x 2.2 Weight +/- 10% 4,000 7,250 8,400 9,970 15,100 900 2,300 2,300 3,500 4,250 4,250 5,600 8,500 A/C Air (SCF M) 12,50 6,250 18,75 0 21,50 0 36,00 0 0 1,000 2,000 2,000 3,000 4,000 4,000 6,000 8,000 LAT ( F)(gr /lb) 60 / 83 61 / 83 62 / 83 59 / 74 61 / 80 75 / 63 75 / 65 72 / 55 76 / 65 80 / 68 78 / 49 75 / 53 74 / 52 Total Btuh 359,719 1,079,15 719,438 1,435,77 6 2,174,04 0 0 56,880 110,880 131,580 163,080 191,340 253,620 383,400 525,600 The HCU models utilize Desiccant Wheel

XZIEX 25 50/60 Hz With A/C Technical Specifications 560 gallons / 2,120 liters of water per day or 204,400 gallons / 773,800 liters per year Energy consumption 32 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 70 in/1.8 m x 80 in/2 m x 188 in/4.8m & Weights 6,000 lbs./2,722 kgs. Moisture removal rate of 196 lbs/hr at 85 F and 70% RH Utilities: 208 or 230 Volts, Single or Three Phase 50/60 Hz Cost of water/gallon = 1.37 x electric cost per kwh Conditioned Air = 6,250 SCFM Uses 25 tons of compressor cooling Total BTU = 359,719 The HCU models utilize Desiccant Wheel

XZIEX 25 50/60 Hz Without A/C Technical Specifications 530 gallons / 2,006 liters of water per day or 193,450 gallons / 732,190 liters per year Energy consumption 32 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 70 in/1.8 m x 80 in/2 m x 219 in/5.6m & Weights 6,000 lbs./2,722 kgs. Moisture removal rate of 196 lbs/hr at 85 F and 70% RH Utilities: 208 or 230 Volts, Single or Three Phase 50/60 Hz Cost of water/gallon = 1.37 x electric cost per kwh Conditioned Air = 6,250 SCFM Uses 25 tons of compressor cooling Total BTU = 359,719 The HCU models utilize Desiccant Wheel

XZIEX 50 50/60 Hz With A/C Technical Specifications 1,135 gallons / 4,296 liters of water per day or 414,275 gallons / 1,568,040 liters per year Energy consumption 65 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 102 in/2.6 m x 96 in/2.4 m x 219 in/5.6m & Weights 9,600 lbs./4,355 kgs. Moisture removal rate of 397.25 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase Cost of water/gallon = 1.37 x electric cost per kwh Conditioned Air = 12,500 SCFM Uses 50 tons of compressor cooling Total BTU = 719,438 The HCU models utilize The Desiccant HCU models Wheel utilize Desiccant Wheel

XZIEX 50 50/60 Hz Without A/C Technical Specifications 1,080 gallons / 4,088 liters of water per day or 394,200 gallons / 1,492,120 liters per year Energy consumption 63 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 102 in/2.6 m x 96 in/2.4 m x 219 in/5.6m & Weights 9,600 lbs./4,355 kgs. Moisture removal rate of 378 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase Cost of water/gallon = 1.40 x electric cost per kwh Conditioned Air = 12,500 SCFM Uses 50 tons of compressor cooling The HCU models utilize The Desiccant HCU models Wheel utilize Desiccant Wheel

XZIEX 75 50/60 Hz With A/C Technical Specifications 1,700 gallons/6,435 liters of water per day or 620,500 gallons/2,348,775 liters per year Energy consumption 96 kilowatt/hour (kwh) at 85 F and 70% RH H x W x L = 102 in/2.6m x 96 in/2.4m x 249 in/6.3 m & Weights 9,600 lbs/4,355 kgs Supply Fan: Centrifugal with variable speed control Utilities: 460/208 or 230 Volts, 50/60Hz Three Phase Cost of water/gallon = 1.36 x electric cost per kwh Moisture removal rate of 595 lbs/hr at 85 F and 70% RH Conditioned Air = 18,750 SCFM Uses 75 tons of compressor cooling Total BTU = 1,079,156 The HCU models utilize Desiccant Wheel

XZIEX 75 50/60 Hz Without A/C Technical Specifications 1,620 gallons/6,132 liters of water per day or 591,300 gallons/2,238,180 liters per year Energy consumption 94 kilowatt/hour (kwh) at 85 F and 70% RH H x W x L = 102 in/2.6m x 96 in/2.4m x 249 in/6.3m & Weights 9,600 lbs/4,355 kgs Supply Fan: Centrifugal w. variable speed control Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase Cost of water/gallon = 1.39 x electric cost per kwh Moisture removal rate of 567 lbs/hr at 85 F and 70% RH Conditioned Air = 18,750 SCFM Uses 75 tons of compressor cooling The HCU models utilize Desiccant Wheel

XZIEX 100 50 Hz With A/C Technical Specifications 2,230 gallons/8,441 liters of water per day or 813,950 gallons/3,080,965 liters per year Energy consumption 134 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 102 in/2.6m x 96 in/2.4m x 280 in/7.1m & Weights 9,300 lbs/4218 kgs Moisture removal rate of 780.5 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50 Hz, Three Phase Cost of water/gallon = 1.44 x electric cost per kwh Conditioned Air = 21,500 SCFM Uses 100 tons of compressor cooling Total BTU = 1,435,770

XZIEX 100 50/60 Hz Without A/C Technical Specifications 2,055 gallons/7,778 liters of water per day or 750,075 gallons/2,838,970 liters per year Energy consumption 131 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 102 in/2.6m x 96 in/2.4m x 249 in/7.1m & Weights 9,300 lbs/4218 kgs Moisture removal rate of 719.25 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50/60 Hz, Three Phase Cost of water/gallon = 1.53 x electric cost per kwh Conditioned Air = 21,500 SCFM Uses 100 tons of compressor cooling Total BTU = 1,435,770 The HCU models utilize Desiccant Wheel

XZIEX 150 XZIEX 25 50/60 Hz Without A/C A/C Technical Technical Specifications 3,470 gallons/13,134 liters of water per day or 1,266,550 gallons/4,793,910 liters per year Energy consumption 195 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 133 in/3.4m x 127 in/3.2m x 403 in/10.2 m & Weights 9,300 lbs/4,218 kgs Moisture removal rate of 1,214.50 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase Cost of water/gallon = 1.35 x electricity cost per kwh Conditioned Air = 39,750 SCFM Uses 150 tons of compressor cooling Total BTU = 2,174,040 The HCU models utilize Desiccant Wheel

XZIEX 100 XZIEX 25 50/60 Hz Without A/C Technical Specifications 3,350 gallons/12,680 liters of water per day or 1,222,750 gallons/4,628,200 liters per year Energy consumption 190 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 133 in/3.4m x 127 in/3.2m x 403 & Weights 9,300 lbs/4,218 kgs Moisture removal rate of 1,172.50 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase Cost of water/gallon = 1.36 x electricity cost per kwh Conditioned Air = 39,750 SCFM Uses 150 tons of compressor cooling The HCU models utilize Desiccant Wheel

HCU 1004 60/50 Hz Technical Specifications @ 60Hz = 83 gallons/313 liters of water per day or 30,295 gallons/114,515 liters/yr @ 50Hz = 69 gallons/261 liters of water per day or 25,185 gallons/95.200 liters/yr Energy consumption 7 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 44 in/1m x 50 in/1.2m x 99 in/2.3m & Weights 900 lbs/408 kgs Moisture removal rate of 29.05 lbs/hr at 85 F and 70% RH Utilities: 208 or 230 Volts, Single or Three Phase 50 Hz Cost of water/gallon = 1.47 x electric cost per kwh Conditioned Air = 1000 SCFM @ 60Hz = 4 tons of refrigeration/@ 50Hz = 3 tons of refrigeration Total BTU = 56,880 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only) Please do not hesitate to contact us for more details on the specifications The HCU models utilize Desiccant Wheel

XZIEX HCU 2008 60/50 Hz Technical Specifications @ 60 Hz =169 gallons/641 liters of water per day or 61,685 gallons/233,965 liters per yr @ 50 Hz = 133 gallons/503 liters per day or 48,545 gallons/183,500 liters per yr Energy consumption 15 kilowatts/hour (kwh) at 85 F and 70%RH H x W x L = 54 in/1.4m x 60 in/1.5m x 118 in/3m & Weights 1,550 lbs/703 kgs Supply Fan: Centrifugal w. variable speed controls Utilities: 230 Volts, Three Phase 50/60 Hz Cost of water per gallon = 1.69 x cost of electricity per KwH Moisture removal rate of 55.65 lbs/hr at 85 F and 70%RH Conditioned Air = 2000 SCFM @ 60 Hz = 8 tons of refrigeration/@ 50 Hz = 7 tons of refrigeration Total BTU = 110,880 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only) The HCU models utilize Desiccant Wheel

XZIEX HCU 3012 60/50 Hz Technical Specifications @ 60 Hz =231 gallons/873 liters of water per day or 84,315 gallons/318,711 liters per yr @ 50 Hz = 193 gallons/730 liters of water per day or 70,445 gallons/266,282 liters per yr Energy consumption 19 kilowatts/hour (kwh) at 85 F and 70%RH H x W x L = 54 in/1.4m x 60 in/1.5m x 118 in/3m & Weights 1,500 lbs/680 kgs Supply Fan: Centrifugal w. variable speed controls Utilities: 230 Volts, Three Phase 50/60 Hz Cost of water per gallon = 1.63 x cost of electricity per KwH Moisture removal rate of 55.65 lbs/hr at 85 F and 70%RH Conditioned Air = 3000 SCFM @ 60 Hz = 12 tons of refrigeration/@ 50 Hz = 10 tons of refrigeration Total Btuh = 163,080 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only) Please do not hesitate to contact us for more details on the specifications The HCU models utilize Desiccant Wheel

XZIEX HCU 4016 50/60 Hz Technical Specifications @ 60 Hz = 303 gallons/1,145 liters per day or 110,595 gallons/418,049 liters per year @ 50 Hz = 253 gallons/956.34 liters per day or 92,345 gallons/ 349,064 liters per year Energy consumption 20 kilowatts/ hour (kwh) at 85 F and 70% RH H x W x L = 70 in/1.8m x 66 in/1.7m x 127 in/3.2 m & Weights 4,250 lbs/1,928 kgs Supply Fan: Centrifugal with variable speed control Utilities: 460/208 or 230 Volts, Three Phase 50/60 Hz Cost of water/gallon = 1.57 x electric cost per kwh Moisture removal rate of 106.50 lbs/hr at 85 F and 70% RH Conditioned Air = 4000 SCFM @ 60 Hz = 16 tons of refrigeration/ @ 50 Hz = 13 tons of refrigeration Total BTU = 191,340 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)

XZIEX HCU 6030 50/60 Hz Technical Specifications @ 60 Hz = 599 gallons/2,264 liters per day or 218,635 gallons/826,440 liters per year @ 50 Hz = 499 gallons/1,886 liters per day or 182,135 gallons/688,470 liters per year Energy consumption 32 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 70 in/1.8m x 66 in/1.7m x 127 in/3.2 m & Weights 4,850 lbs/2,200 kgs Moisture removal rate of 209.65 lbs/hr at 85 F and 70% RH Utilities: 220 Volts, Single or Three Phase 50/60 Hz Cost of water/gallon = 1.65 x electric cost per kwh Conditioned Air = 6000 SCFM @ 60 Hz = 30 tons of refrigeration/ @ 50 Hz = 25 tons of refrigeration Total BTU = 383,400 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (in the United States only)

XZIEX HCU 8040 50/60 Hz Technical Specifications @ 60 Hz = 813 gallons/3,073 liters per day or 296,745 gallons/1,121,696 liters per year @ 50 Hz = 678 gallons/2,563 liters per day or 247,470 gallons/935,437 liters per year Energy consumption: 40 kilowatts per hour (kwh) at 85 F and 70% RH H x W x L = 86 in/2.2m x 81 in/2m x 187 in/4.5m & Weights 5,850 lbs/2,654 kgs Moisture removal rate is 284.55 lbs/hr at 85 F and 70% RH Utilities: 460/208 or 230 Volts, 50/60 Hz Three Phase Cost of water/gallon = 1.18 x electric cost per kwh Conditioned Air = 8000 SCFM @ 60 Hz = 40 tons of refrigeration/ @ 50 Hz = 33 tons of refrigeration Total BTU = 525,600 Utilizes Desiccant Wheel. Qualifies for L.E.E.D credits (United States only)

STANDARD FILTRATION SYSTEM Technical Specifications 1. Recirculation and delivery pump constantly re circulates water in storage tank and delivers water to point of use (POU). Has built in controls that protect pump from running in zero flow condition 2. Sediment filter five micron string wound filter the removes suspended solids from water 3. Carbon filter removes organics and oxidants from the water 4. Pressure gauges show the inlet and outlet pressures of the filter cartridges. Change the filters when there is a 10 psi increase in the difference between these two gauges. 5. Germicidal Ultraviolet Unit. the UV chamber allows filtered water to be exposed to high levels of ultraviolet (UV) light. UV treatment disinfects water and prevents buildup of bacteria. 6. Ozone injection. ozone gas is drawn into the tank recirculation stream. Ozone is a very strong oxidant and provides a residual disinfectant that keeps water in the tank free of any biological growth

ATMOSPHERIC WATER GENERATORS ON THE CUTTING EDGE OF A WATER REVOLUTION

Thank you!