SFP+ BIDI Series Preliminary EOLP-BI1696-XAD & EOLP-BI1696-XDA Series

Similar documents
EOLP-BI1696-XAD & EOLP-BI1696-XDA Series

Part No. Data Rate Wavelength Interface Temp. DDMI EOLS-BI * (note1) EOLS-BI * (note1) Up to 4.25Gbps 1550nm SC Standard NO

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

CWDM BIDI SFP Series. EOLS-BI XX 21XX 24XX 26XX 34XX Series. Features. Applications. Ordering information

DWDM SFP Series. Laser

10GE BIDI SFP+ Series

EOLQ-851HG-02-MO Series Multi-Mode 100GBASE-SR4 QSFP28 Transceiver RoHS6 Compliant

GBIC BIDI Series EOLG-BI1X12-X series

GBIC BIDI Series EOLG-BI1X12-X series

CWDM / 12 Gb/s Medium Power SM Video Digital Diagnostic SFP+ Transceiver

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

Single Fiber SFP Series

CWDM SFP Series. EOLS-1624-XX Series. Features. Applications. Ordering Information

QSFP28 Series Preliminary. EOLQ-161HG-20-LA2 Series. Features. Applications. Ordering Information

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

XFP Bi-Directional 10G 20Km 1270/1330nmTx / 1330/1270nmRx SLXFB-XXXX-20

10Gbps 10km Range SFP+ Optical Transceiver

Dual Fiber SFP Series

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

10G- XFP- LR- AO. 10Gbs XFP Transceiver

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

T A S A 2 N B 1 F A H

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

XFP-1020-WA/B 10Gbps XFP Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

Part No. Input Output Burst-mode DDM Interface Temp. EOLS-GT-35-D* (note1) AC DC LVTTL YES SC 0~70 EOLS-GT-35-DI AC DC LVTTL YES SC -40~85

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS. Logic Symbol Name/Description Note 1 - GND Module Ground 1

10G- XFP- SR- AO. 10Gbs XFP Transceiver

3G-SDI Video SFP CWDM nm 40km Optical Transceivers

10G BiDi XFP 10km Optical Transceiver GBX-xxxx192-LRC

1310nm Single Channel Optical Transmitter

10Gbps SFP+ Optical Transceiver, 10km Reach

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

GbE SFP CWDM Transceiver (120km) RCP12SVX

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

10Gb/s XFP Optical Transceiver Module

OC-48/STM-16 SFP Transceiver (SR) RSP25SS1

1310nm Video SFP Optical Transceiver

Product Specification XFP 10G LR 20km LC Optical Transceiver

Product Specification. 10Gb/s, 10km XFP Optical Transceiver FTLX1413M3BCL

10Gb/s 40km DWDM XFP Optical Transceiver

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

Applications LX xDR 10Gb. Gb/s 10km XFP Optical Transceiver

GIGALIGHT 300m XFP Optical Transceiver GX SRC

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

FTS-S12G-B53Y-005. SFP 1000Base-LX, BiDi, 1550/1310nm, single-mode, 5km

1550 nm / 3 Gb/s Medium Power Single Optical SM Digital Diagnostic Transmitter FVD2-1TR-SM50

CWDM GBIC. 1.25Gbps GBIC Optical Transceiver, 80km Reach

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

XFP Optical Transceiver

WS G Gbps GBIC Optical Transceiver, 80km Reach

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

Very Long Haul Multi-rate Gigabit Ethernet SFP CWDM Transceivers with Digital Diagnostics

Intel Ethernet SFP+ Optics

XFP 10G 850nm 300M SR SLXF-1085-SR

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

XFP ZR Optical Transceiver, 80km Reach GX ZRC

FTS-R27G-S31L-002DI. Multirate SFP 125Mbps-2.67Gbps, 1310nm, single-mode, 2km

10G E-PON ONU PR-30 Transceiver (20km)

Gigabit Ethernet CWDM SFP Transceivers

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

AddOn Computer s SFP transceivers are RoHS compliant and lead- free.

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

SFP-Bxx-ttrr. Up to 80km Sinlge-Mode SFP Transceiver. Features. Applications. Benefits

10G/1G E-PON ONU SFP+ Bidi Optical Transceiver (20km) P3157-8D20-RSP

Applications: Features: Description: 10G SFP+ Transceiver LR 10km (PLS-10G-LR) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD

Tunable SFP+ DWDM 10G 80Km ZR SLSSD-10GE-ZR-T

3G-SDI Video SFP Rx Optical Receivers

SHQP28-100G-LR4-B. 103/112Gb/s QSFP28 Transceiver Hot Pluggable, Duplex LC, +3.3V, 1310nm DML/PIN, Single mode, 10km, 0~70 C

SNR-SFP-W43-GPON-C+ GPON OLT Series

Features: Compliance: Applications: Warranty: QSFP-40G-LR4-GT 40GBASE-LR4 QSFP+ SMF Module Cisco Compatible

QSFP+ 40GBASE-SR4 Fiber Transceiver

Part No. Data Rate Distance Interface Temp. DDMI MMF OM3 for 70m QSFP28.100G.SR Gbps

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

LambdaFLEX Zero Chirp Tunable XFP Module TL8800ZPCND

Part No. Input Output Burst-mode DDM Interface Temp. EOLS-GT-35-D* (note1) AC DC LVTTL YES SC 0~70 EOLS-GT-35-DI AC DC LVTTL YES SC -40~85

40GBd QSFP+ SR4 Transceiver

LambdaFLEX Negative Chirp Tunable XFP Module TL8900NACND

GPON ONU Triplexer Transceiver

LambdaFLEX Tunable XFP Module

Datasheet. 10GBASE-ZR SFP+ 1550nm 80Km DOM Transceiver SFP-10GZR-55. Features. Application

Gigabit Ethernet LC Bi-directional SFP Transceivers RBT12SLX

Parameter Symbol Min. Typ. Max. Unit. Supply Voltage Vcc V. Input Voltage Vin -0.3 Vcc+0.3 V. Storage Temperature Tst C

QSFP+ 40GBASE-LR4 Fiber Transceiver

100G QSFP28 SR4 Transceiver

CWDM Optical Transceiver

Small Form-factor Pluggable (SFP) Optical Module Cartridges (Ethernet) For Densité Frames and Grass Valley/Telecast Standalone Fiber Products

OP6F-S04-13-xM Datasheet

10303 (10G BASE-LRM SFP+) Datasheet

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

OC-48/STM-16 LC Bi-directional SFP Transceiver (2km) RBT25xS1

QSFP-100G-LR4-AR-LEG. 100Gbase-LR4 QSFP28 Transceiver

PRE-QSFP-LR4L 100G QSFP 28 Dual Range Optical Transceiver, 10km. Product Features: General Product Description:

Transcription:

EOLP-BI1696-XAD & EOLP-BI1696-XDA Series Tx: 1270nm/Rx: 1330nm BIDI SFP+ Transceiver for 10GbE Tx: 1330nm/Rx: 1270nm BIDI SFP+ Transceiver for 10GbE RoHS 6 Compliant Features Operating data rate up to 10.3Gbps Two types: A: 1270nm DFB / 1330nm B: 1330nm DFB / 1270nm Single 3.3 Power supply and TTL Logic Interface SC Connector Interface Hot Pluggable Power Dissipation < 1.2W Operating Case Temperature Standard: 0~+70 Extended: -10~+85 Compliant with SFP+ MSA Specification SFF-8431 Applications 10GBASE-LR at 10.3125Gbps 10GBASE-LW at 9.953Gbps Other Optical Links Compliant with SFF-8472 Ordering information Part No. Data Rate Laser Temp. Power Optical budget Interface DDMI EOLP-BI1696-9AD* 10.3Gbps 1270nm DFB Standard 9dB SC YES EOLP-BI1696-9DA 10.3Gbps 1330nm DFB Standard 9dB SC YES EOLP-BI1696-9ADI 10.3Gbps 1270nm DFB Extended 9dB SC YES EOLP-BI1696-9DAI 10.3Gbps 1330nm DFB Extended 9dB SC YES EOLP-BI1696-12AD* 10.3Gbps 1270nm DFB Standard 12dB SC YES EOLP-BI1696-12DA 10.3Gbps 1330nm DFB Standard 12dB SC YES EOLP-BI1696-12ADI 10.3Gbps 1270nm DFB Extended 12dB SC YES EOLP-BI1696-12DAI 10.3Gbps 1330nm DFB Extended 12dB SC YES EOLP-BI1696-14AD* 10.3Gbps 1270nm DFB Standard 14dB SC YES EOLP-BI1696-14DA 10.3Gbps 1330nm DFB Standard 14dB SC YES EOLP-BI1696-14ADI 10.3Gbps 1270nm DFB Extended 14dB SC YES EOLP-BI1696-14DAI 10.3Gbps 1330nm DFB Extended 14dB SC YES *Note1: Standard version. Page 1 of 13 1.a

Regulatory Compliance* Product Certificate Certificate Number Applicable Standard TU R50135086 EN 60950-1:2006+A11+A1+A12 EN 60825-1:2007 EN 60825-2:2004+A1+A2 UL E317337 UL 60950-1 CSA C22.2 No. 60950-1-07 EMC CE AE 50285865 0001 EN 55022:2010 EN 55024:2010 CB JPTU-049251 IEC 60825-1 IEC 60950-1 FCC WTF14F0514437E 47 CFR PART 15 OCT., 2013 FDA 1331340-000 CDRH 1040.10 ROHS RHS01G006464 2011/65/EU *The above certificate number updated to June 2014, because some certificate will be updated every year, such as FCC, FDA and ROHS. For the latest certification information, please check with Eoptolink. Product Description The EOLP-BI1696-XAD/DA series single mode transceiver is small form factor pluggable module for bidirectional optical data communications, such as 10GBASE-LR/LW defined by IEEE 802.3ae. It is with the SFP+ 20-pin connector to allow hot plug capability. The EOLP-BI1696-XAD module is designed for single mode fiber and operates at a nominal wavelength of 1270nm; EOLP-BI1696-XDA module is designed for single mode fiber and operates at a nominal wavelength of 1330nm. The transmitter section uses a multiple quantum well DFB, which is class 1 laser compliant according to International Safety Standard IEC-60825. The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. Absolute Maximum Ratings* Parameter Symbol Min. Max. Unit Storage Temperature T S -40 +85 C Supply oltage CC -0.5 3.6 *Note2: Exceeding any one of these values may destroy the device permanently. Recommended Operating Conditions Parameter Symbol Min. Typical Max Unit Power Supply oltage CC 3.14 3.3 3.46 Power Supply Current I CC 365 ma Surge Current I Surge +30 ma Page 2 of 13 1.a

Operating Case Temperature SFP+ BIDI Series T C @EOLP-BI1696-XAD/DA 0 70 C T C @EOLP-BI1696-XADI/DAI -10 85 C Baud Rate 9.953/10.3125 GBaud Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes CML Inputs(Differential) Input Impedance (Differential) Tx_DISABLE Input oltage - High Tx_DISABLE Input oltage - Low Tx_FAULT Output oltage - High Tx_FAULT Output oltage - Low CML Outputs (Differential) Output Impedance (Differential) Rx_LOS Output oltage - High Rx_LOS Output oltage - Low MOD_DEF ( 2:0 ) in 150 1200 mpp Zin 85 100 115 ohms 2 cc+0.3 0 0.8 2 cc+0.3 AC coupled inputs Rin > 100 kohms @ DC Io = 400µA; Host Data Rate 9.953/10.3125 Gbps Centre Wavelength λ C 1260 1270 1280 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power *note3 P out, AG -5 0 dbm Extinction Ratio ER 3.5 db Page 3 of 13 1.a cc 0 0.5 Io = -4.0mA out 350 700 mpp Zout 85 100 115 ohms 2 cc+0.3 AC coupled outputs lo = 400µA; Host cc 0 0.8 lo = -4.0mA oh 2.5 ol 0 0.5 Optical and Electrical Characteristics With Serial ID (EOLP-BI1696-9AD, 1270nm DFB & PIN/TIA) Parameter Symbol Min. Typical Max. Unit Power Budget 9 db

and Dispersion Penalty TDP 2 db Average Power of OFF -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 cc+0.3 Enable 0 0.8 Fault 2.0 CC +0.3 Normal 0 0.8 TX Disable Assert Time t_off 10 us Centre Wavelength λ C 1320 1340 nm Sensitivity *note4 P IN -14 dbm Overload P MAX 0.5 dbm Output Differential Impedance P IN 90 100 110 Ω LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm LOS High 2.0 CC +0.3 Low 0 0.8 (EOLP-BI1696-9DA, 1330nm DFB & PIN/TIA) Parameter Symbol Min. Typical Max. Unit Power Budget 9 db Data Rate 9.953/10.3125 Gbps Centre Wavelength λ C 1320 1330 1340 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power *note3 P out, AG -5 0 dbm Extinction Ratio ER 3.5 db and Dispersion Penalty TDP 2 db Average Power of OFF -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable Disable 2.0 cc+0.3 Enable 0 0.8 TX Fault Fault 2.0 CC +0.3 Normal 0 0.8 TX Disable Assert Time t_off 10 us Centre Wavelength λ C 1260 1280 nm Sensitivity *note4 P IN -14 dbm Overload P MAX 0.5 dbm Output Differential Impedance P IN 90 100 110 Ω Page 4 of 13 1.a

LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm High 2.0 CC +0.3 LOS Low 0 0.8 (EOLP-BI1696-12AD, 1270nm DFB & PIN/TIA) Parameter Symbol Min. Typical Max. Unit Power Budget 12 db Data Rate 9.953/10.3125 Gbps Centre Wavelength λ C 1260 1270 1280 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power *note3 P out, AG -2 3 dbm Extinction Ratio ER 3.5 db and Dispersion Penalty TDP 2 db Average Power of OFF -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 cc+0.3 Enable 0 0.8 Fault 2.0 CC +0.3 Normal 0 0.8 TX Disable Assert Time t_off 10 us Centre Wavelength λ C 1320 1340 nm Sensitivity *note4 P IN -14 dbm Overload P MAX 0.5 dbm Output Differential Impedance P IN 90 100 110 Ω LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm LOS High 2.0 CC +0.3 Low 0 0.8 (EOLP-BI1696-12DA, 1330nm DFB & PIN/TIA) Parameter Symbol Min. Typical Max. Unit Power Budget 12 db Data Rate 9.953/10.3125 Gbps Centre Wavelength λ C 1320 1330 1340 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power *note3 P out, AG -2 3 dbm Page 5 of 13 1.a

Extinction Ratio ER 3.5 db and Dispersion Penalty TDP 2 db Average Power of OFF -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 cc+0.3 Enable 0 0.8 Fault 2.0 CC +0.3 Normal 0 0.8 TX Disable Assert Time t_off 10 us Centre Wavelength λ C 1260 1280 nm Sensitivity *note4 P IN -14 dbm Overload P MAX 0.5 dbm Output Differential Impedance P IN 90 100 110 Ω LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm LOS High 2.0 CC +0.3 (EOLP-BI1696-14AD, 1270nm DFB & PIN/TIA) Parameter Symbol Min. Typical Max. Unit Power Budget 14 db Data Rate 9.953/10.3125 Gbps Centre Wavelength λ C 1260 1270 1280 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power *note3 P out, AG 0 5 dbm Extinction Ratio ER 3.5 db and Dispersion Penalty TDP 2 db Average Power of OFF -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable Disable 2.0 cc+0.3 Enable 0 0.8 TX Fault Fault 2.0 CC +0.3 Normal 0 0.8 TX Disable Assert Time t_off 10 us Centre Wavelength λ C 1320 1340 nm Sensitivity *note4 P IN -14 dbm Overload P MAX 0.5 dbm Page 6 of 13 1.a

Output Differential Impedance P IN 90 100 110 Ω LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm LOS High 2.0 CC +0.3 Low 0 0.8 (EOLP-BI1696-14DA, 1330nm DFB & PIN/TIA) Parameter Symbol Min. Typical Max. Unit Power Budget 14 db Data Rate 9.953/10.3125 Gbps Centre Wavelength λ C 1320 1330 1340 nm Spectral Width (-20dB) Δλ 1 nm Side Mode Suppression Ratio SMSR 30 db Average Output Power *note3 P out, AG 0 5 dbm Extinction Ratio ER 3.5 db and Dispersion Penalty TDP 2 db Average Power of OFF -30 dbm Relative Intensity Noise RIN -128 db/hz Input Differential Impedance Z IN 90 100 110 Ω TX Disable TX Fault Disable 2.0 cc+0.3 Enable 0 0.8 Fault 2.0 CC +0.3 Normal 0 0.8 TX Disable Assert Time t_off 10 us Centre Wavelength λ C 1260 1280 nm Sensitivity *note4 P IN -14 dbm Overload P MAX 0.5 dbm Output Differential Impedance P IN 90 100 110 Ω LOS De-Assert LOS D -18 dbm LOS Assert LOS A -30 dbm LOS High 2.0 CC +0.3 *Note3: Output is coupled into a 9/125um SMF. *Note4: Measured with worst ER, BER less than 1E-12 and PRBS 2 31-1 at 10.3125Gbps. Page 7 of 13 1.a

SFP+ Transceiver Electrical Pad Layout SFP+ BIDI Series Pin Function Definitions Page 8 of 13 1.a

Pin Plug Name FUNCTION Num. Seq. Notes 1 eet Ground 1 Note 5 2 TX Fault Fault Indication 3 Note 1 3 TX Disable Disable 3 Note 2, Module disables on high or open 4 SDA Module Definition 2 3 Data line for Serial ID. 5 SCL Module Definition 1 3 Clock line for Serial ID. 6 MOD_ABS Module Definition 0 3 Note 3 7 RS0 This pin has an internal 30k pull down to RX Rate Select 3 ground. A signal on this pin will not affect (LTTL). module performance. 8 LOS Loss of Signal 3 Note 4 9 RS1 This pin has an internal 30k pull down to TX Rate Select 1 ground. A signal on this pin will not affect (LTTL). module performance. 10 eer Ground 1 Note 5 11 eer Ground 1 Note 5 12 RD- Inv. Received Data Out 3 Note 6 13 RD+ Received Data Out 3 Note 6 14 eer Ground 1 Note 5 15 ccr Power 2 3.3 ± 5%, Note 7 16 cct Power 2 3.3 ± 5%, Note 7 17 eet Ground 1 Note 5 18 TD+ Transmit Data In 3 Note 8 19 TD- Inv. Transmit Data In 3 Note 8 20 eet Ground 1 Note 5 Page 9 of 13 1.a

Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor on the host board. Pull up voltage between 2.0 and cct/r+0.3. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7K 10 KΩ resistor. Its states are: Low (0 0.8): on (>0.8, < 2.0): Undefined High (2.0 3.465): Disabled Open: Disabled 3) Module Absent, connected to eet or eer in the module. 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10KΩ resistor. Pull up voltage between 2.0 and cct/r+0.3. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8. 5) eer and eet may be internally connected within the SFP+ module. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 350 and 700 m differential (175 350 m single ended) when properly terminated. 7) ccr and cct are the receiver and transmitter power supplies. They are defined as 3.3 ±5% at the SFP+ connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SFP+ input pin with 3.3 supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP+ transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. ccr and cct may be internally connected within the SFP+ transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 150 1200 m (75 600m single-ended). Page 10 of 13 1.a

EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not writing protected within the SFP+ transceiver. The negative edge clocks data from the SFP+ transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2h. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 10.2. Page 11 of 13 1.a

Recommend Circuit Schematic SFP+ BIDI Series Mechanical Specifications Page 12 of 13 1.a

Eye Safety This single-mode transceiver is a Class 1 laser product. It complies with IEC-60825 and FDA 21 CFR 1040.10 and 1040.11. The transceiver must be operated within the specified temperature and voltage limits. The optical ports of the module shall be terminated with an optical connector or with a dust plug. Obtaining Document You can visit our website:http://www.eoptolink.com Or contact Listed at the end of the documentation to get the latest document. Revision History Revision Initiated Reviewed Approved DCN Release Date 1.a Oliver Lyn/Fing Phlio Aug 28, 2014 Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5 Building 2 No. 21 Gaopeng Avenue High-Tech District CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 808 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:sales@eoptolink.com http://www.eoptolink.com Page 13 of 13 1.a