INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

Similar documents
Hybrid Chart Recorder 250 mm (10")

FP93 Program Controller

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

FX0N-3A SPECIAL FUNCTION BLOCK

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Global Water Instrumentation, Inc.

USER S MANUAL. FX2N-8AD Analog input block

Display Information Type Backlit blue on white STN Type

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Set Point Controller OC557. Operator s Manual

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Digital Ratio Controller

3M Sensored Termination (15 kv) QX-T15I-vi1-E

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

TABLE OF CONTENTS. Instructions:

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

LAUREL ELECTRONICS, INC.

JENCO ELECTRONICS, LTD.

02/11/2015

Quick Operation Guide of LTN7700/7600 Series NVR

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

DCP100 Digital Control Programmer Specifications

K3NX Process Meter OPERATION MANUAL

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

SCALE & WEIGHT DISPLAYS

Instruction Manual Model BlockUpconverter

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Instruction Manual Model # Block Upconverter

Process Transmitter RMA 422

SAFETY TERMS AND SYMBOLS

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

R&S RT-Zxx High-Bandwidth Probes Specifications

Analogue output module DAO 081

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

actions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

EM70 Servo Controller Instruction Manual

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Eddy Current Probe System

Spectra Batten (Order code: LEDJ95)

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

CARLO GAVAZZI Automation Components

Micro-DCI 53ML5100 Manual Loader

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Model Number Structure

User s Manual TOS7200. Insulation Resistance Tester DANGER. 1. Preface Preparation Safety Precautions during Testing 19

Standard signal metering in wall-mounting case

Solid-State Digital Timer

Kuhnke Technical Data. Contact Details

EVENT INPUT/OUTPUT MODULE [PUME]

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

LED Driver Linear / area fixed output

Series CT7N Bimetallic Overload Relays

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

PRINCIPLES AND APPLICATIONS

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Process transmitter RMA422

Digital output modules

CONDITIONER TERMINAL BLOCK 8 ISOLATED ANALOG INPUTS STB 582

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Type Contact form Model

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Ezecal MK3 User Manual

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

GC30 Digital Differential Pressure Gauge Operation Manual

The Art of Engineering

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Electronic converter for level transmitters MT03L Instructions manual

Wall-/Pipe-Mount Level Indicator

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

LED Backlight for Technics amplifiers

Transcription:

INST No.CP970-2 CP Computing unit Model CP970 Instruction Manual Important Notice Keep this manual with due care after understanding operation. 新栄熱計装株式会社

- Contents - Preface... 1 1 Outline... 2 2 Specifications... 2 1. Input specifications 2. Output specifications 3. Impedance check function 4. Computation specifications 5. CP value correction function 6. Explanation of status 7. Explanation of operation key 8. General specifications 3 Operation procedure... 7 4 Parameter directory... 8 5 Parameter list... 11 6 External dimensions... 13 7 Error and warning... 14 8 Parameter sheet... 15

Preface Please be sure to observe the following warnings for safe use. 1. Mounting location and terminal cover This instrument has been designed to be mounted on a panel. For preventing electric shock, take safety measures to avoid contact with power and input/output terminals. Keep 50cm or more away from power line and other communication line to avoid noises. After connections, mount the terminal cover at all times. 2. Use crimp style terminals Use the crimp style terminals with insulations sleeve. Use the O type termination for power terminal and ground terminal. Recommend to use the O type termination for other than above terminals. O type Y type Insulation sleeve Insulation sleeve B B A A Size A: 3.7mm or above B: 7.0mm or above 3. Take safety measures separately When this instrument is assembled into the final product (equipment) requiring security measures, take safety measures on the final product side to be observed, if a control failure occurred due to a temperature sensor trouble, wrong operation or other circumstances. 4. Prepare a power switch separately Neither power switch nor fuse is mounted in this instrument. Mount them on the final product side. 1) For the contents of this manual, alteration is reserved without notice in the future. 2) This manual has been prepared by making assurance doubly sure about its contents. However, if any question arises or if any error, an omission, or other deficiencies were found, please inform your nearest CHINO's sales agent of them. 3) You are requested to understand that CHINO is not responsible for any operation results in spite of item 2). - 1 -

1 Outline This CP computing unit computes CP (carbon potential) value by inputting O2, temperature, CO, and CO2, and outputs the result. Input type is switched by CP computation mode selection parameter of mode. Type 1: 3 inputs of O2, temperature, and CO2 Display CP value computed from O2 in upper of display 1, and display computed result of CO2 in display 2. Type 2: 3 inputs of CO2, temperature, and CO Display CP value computed from CO2 in upper of display 1, and display analog input value of CO2 in display 2. Type 3: 4 inputs of O2, temperature, CO, and CO2 Display CP value computed from O2 in upper of display 1, display CP value computed from CO2 in lower of display 1 (depending on setup), and display analog input value of CO2 in display 2 (depending on setup). 2 Specifications 1. Input specifications 1) Mesured value input Input signals: 1. Temperature input 0 to 1200 (K thermocouple) 0 to 1200 (N thermocouple) 0 to 1700 (R thermocouple) 0 to 1700 (S thermocouple) 2. CO input 1 to 5V DC (0.00 to 50.00%) 3. O2 input 0 to 1500mV DC 4. CO2 input 1 to 5V DC (0.000 to 5.000%, change of scale upper limit is possible) Input isolation: Without isolation between CO input and CO2 input Isolation between O2 input and other input Sampling period: 2 seconds or less Burn-out: Thermocouple input Upper limit Scale out CO, O2, and CO2 input None Rated measuring accuracy: Thermocouple input ±0.2% ±1 digit for temperature range (in the standard operation condition) O2 input ±0.1% ±1 digit for 0 to 1500mV DC CO, O2 input ±0.1% ±1 digit for 1 to 5V DC Reference junction compensation accuracy: K, N ±0.5 or equivalent value of 20µV, whichever is greater. (Ambient temperature: 23 ±10 ) Others ±1.5 or equivalent value of 60µV, whichever is greater. Input resistance: Temperature, CO, CO2 input 1MΩ or more O2 input 20MΩ or more Allowable signal source resistance: Temperature, CO, CO2 input 100MΩ or more O2 input 30MΩ or more Maximum input voltage range: Temperature input -2 to 2V O2 input -1 to 2V CO, CO2 input -0.3 to 10V - 2 -

2) Temperature input There are four types of thermocouple (K, N, R, and S), and selected by front setup. Less than -50 is lower limit scale out and more than upper limit +50 of used thermocouple is upper lime scale out. 3) CO input (fixed value is available by inside setup) Full scale of CO input is 0.00 to 50.00%. Less than -0.10% is lower limit scale out and more than 60.00% is upper limit scale out. 4) O2 input Full scale of O2 input is 0 to 1500. Less than -100 is lower limit scale out, and more than 1600 is upper limit scale out. 5) CO2 input Full scale of CO2 input is 0.000 to 5.000% and set by front setup. (Available to change the of scale upper limit) Less than -0.01% is lower limit scale out and more than scale upper limit is upper limit scale out. 6) First order leg computation Perform first order leg computation for all analog inputs and use in internal processing. 7) Contact input: 3 points 1. Impedance check Execute after ON more than 3 seconds 2. CP value shift During ON, effective CP value correction constant 3. CP value hold During ON, fix CP value display and output signal 2. Output specifications 1) Transmission output Output points: 3 points Output signal: 1 to 5V DC (output 1, output 2), 0 to 10mV DC (output 3) Output kinds of output 1 to 3 are different for each type of selection, and computation result is as follows. Type 1 O2CP value/temperature/emf Type 2 CO2CP value/temperature Type 3 O2CP value/ CO2CP value/temperature/emf Output scale: available to set each computation method 1. O2CP value 0.000 to 2.000 2. CO2CP value 0.000 to 2.000 3. Temperature K, N thermocouple: 0 to 1200/R, S thermocouple: 0 to 1700 Output update period: Less than 2 seconds at 3 points Output resolution: About 1/10000 Output accuracy: 1. Output 1 (DAC): ±0.1% (for indication value) 2. Output 2 (PWM): ±0.3% (for indication value) 3. Output 3 (PWM): ±0.3% (for indication value) Isolation: Isolate between each input and output, do not isolate among outputs First order leg computation: Available to set first order leg computation of output (OFF, 1 to 100 seconds) 2) Impedance abnormal output Output signal: Relay output: ON during abnormal Contact capacity: Resistive load 100V AC 3A 200V AC 3A 30V DC 3A Inductive load 100V AC 1.5A 200V AC 1.5A 30V DC 1.5A Electrical life duration: About more than 100,000 times - 3 -

3) Deviation alarm output of CP computation value Make the determine of follows by computation result of CP value CP value (O2) CP value (CO2) > Deviation set value Alarm output is ON during the above formula Output signal: Relay output ON during alarm Contact capacity: Resistive load 100V AC 3A 200V AC 3A 30V DC 3A Inductive load 100V AC 1.5A 200V AC 1.5A 30V DC 1.5A Setting range: 0.000 to 0.999 (0.000 is without alarm computation.) Dead band: 0.1% fixed Electrical life duration: About more than 100,000 times 3. Impedance check function 1) O2 input perform the impedance check once when contact input for impedance is ON more than 3 seconds or front key is pressed more than 3 seconds. However, not perform it for temperature less than 800. Front IMP lamp is lighted during operation. 2) Impedance check measure O2 input by inserting 1MΩ resistance to O2 input circuit and waiting for about 10 seconds. 3) Display calculated impedance value in display 2 for 5 seconds. 4) Abnormal output signal is ON for impedance abnormality when calculated result is over the set value. (Set value: 0 to 30kΩ) Abnormal output signal is reset by following situations. (Without backup) 1. Perform the impedance check again and be in normal range. 2. Turn on the power again. 3. Execute impedance abnormality reset of mode. Note) During impedance check operation, computation function is stopped and last value (computation result, analog output) is stored, and key operation is rejected. 4. Computation specifications 1) Computation for O2 input (Require CP value of temperature, O2, and CO) Exception of CP value computation CP value is fixed 2.000 when temperature input is less than 500 (including lower limit scale out). CP value is fixed 2.000 when temperature input is less than 1350 (including upper limit scale out). CP value is proportion to O2 input and reaches 2.000 when CP value is more than 1.68. 2) Computation for CO2 input (Require CP value of temperature, CO2, and CO) Exception of CP value computation CP value is fixed 2.000 when temperature input is less than 500 (including lower limit scale out). CP value is fixed 2.000 when temperature input is less than 1350 (including upper limit scale out). CP value is fixed 2.000 when CP value is more than 1.68. - 4 -

5. CP value correction function 1) There is the function which is CP value is corrected by following formula. Corrected CP value is used display and output. Available to set in range of -19.9 to 19.9 (A) and -0.999 to 0.999 (B and C). Available to set each computation of O2 input and computation of CO2 input. CPn = CP A + B + C A: Ratio B: Bias C: Bias CPn: CP value after correcting CP: CP value before correcting 2) Setting of A and B is always effective and C is added when external shift contact signal is ON. Front CPSF lamp lights when external shift contact signal is ON. Example) A = 1.1, B = 0.05, C = -0.06 is set and computation result of CP value is 1.234. CP value after correcting is CPn = 1.234 1.1 + 0.05 = 1.4074 A B When external shift contact signal is ON, CP vale after correcting is CPn = 1.234 1.1 + 0.05-0.06 = 1.3474 A B C 6. Explanation of status 1 Display 1 2 3 4 5 6 Display 2 1 (green) Display CP value Light for O2CP mode and CO2CP mode 2 (yellow green) Upper stage displays O2CP and lower stage displays CO2CP Light for O2CO2CP mode 3 (yellow green) Display lock status Light for key lock 4 (yellow green) Display lower display item which is set by mode In case of extinction, display CO2 calculation result 5 (red) Display alarm status IMP Impedance abnormality CP CP value deviation alarm 6 (yellow green) Display external signal input status IMP Impedance check CPSF CP correction value C HOLD CP value hold - 5 -

7. Explanation of operation key Operation key Description Execution impedance check by pressing the key more than 3 seconds Into mode screen Move to next parameter for operation mode and mode Change the number down of each parameter and each digit Change the number up of each parameter and each digit Change the digit of each parameter, Cursor movement of each parameter selection item Switch effective/invalid of key lock by pressing the key more than 3 seconds during operation mode Settlement of parameter changes 8. General specifications Rated power voltage: 100V to 240V AC 50/60Hz free Allowable power voltage: 90 to 264V AC Working temperature range: -10 to 50 (Maximum 40 during closed instrumentation) Working humidity range: 10 to 90%RH (no dew condensation) Insulation resistance: Between primary terminal and secondary terminal 500V DC more than 20MΩ Between primary terminal and ground terminal 500V DC more than 20MΩ Between secondary terminal and ground terminal 500V DC more than 20MΩ *Primary terminal: Each terminal of power supply and alarm terminal Secondary terminal: Terminal of other than those above Withstand voltage: Between primary terminal and secondary terminal 1500V AC for 1 minute Between primary terminal and ground terminal 1500V AC for 1 minute Between secondary terminal and ground terminal 500V AC for 1 minute *Primary terminal: Each terminal of power supply and alarm terminal Secondary terminal: Terminal of other than those above Power failure protection: Settings are stored by EEPROM (number of rewriting less than 100,000 times) Power consumption: Maximum 20VA Case assemble material: Nonflammable polycarbonate Color: Grey Weight: About 580g - 6 -

3 Operation procedure 1. Operation mode Display 1 is always displayed CP value, EMF, and etc. Switch the display 2 every pressing and switch to mode screen after pressing key. key 2. Setting mode 1) Type selection Switch to mode (CP computation mode selection screen) after pressing key in operation mode. Type 1 Display CP value computed from O2 in upper of display 1, and display computed result of CO2 in display 2. Type 2 Display CP value computed from CO2 in upper of display 1, and display analog input value of CO2 in display 2. Type 3 Display CP value computed from O2 in upper of display 1, display CP value computed from CO2 in lower of display 1 (depending on setup), and display analog input value of CO2 in display 2 (depending on setup). 2) Setting parameter Switch to mode (CP computation mode selection screen) after pressing key in operation mode. Switch each parameter screen of mode every pressing There are following items of mode. key. 1CP computation mode selection, 2Lower stand display item selection, 3Thermocouple type, 4Temperature unit, 5CP value decimal point, 6EMF/temperature decimal point, 7Transmission type, 8Output scale of O2 computation CP value, 9Output scale CO2 computation CP value, 10EMF output scale, 11Temperature output scale, 12CP deviation alarm set value, 13O2 scale upper limit value, 14With or without of first order leg computation of output, 15CO correction, 16CO2 correction, 17Key lock, 18Impedance abnormal reset, 19Impedance abnormal determine value, 20Initialize of set value 3. Key lock Become the key lock status after pressing key more than 3 seconds in operation mode. Reset the key lock after pressing key more than 3 seconds in key lock status. Light the lock lamp during key lock. Available to set following level for mode parameter. MODE. LOCK NO. DISP Display mode screen, but do not change. Do not display mode screen. [Flow chart] Power ON 10 seconds all lighting during start up Operation mode 3 seconds Key lock status Setting mode - 7 -

4 Parameter directory CP value computed from O2 (type 1) Operation mode Setting mode Disp01 Operation mode in display 2 TEMP : 1200 CO : 50.00 % Disp02 Disp03 CO2 calculation result CO2 CALCULATION Disp07 Available to display TEMP or EMF on upper stand. 5.000% Disp04 CO internal/external selection CO INT/EXT SELECT INT EXT Disp05 CO internal fixed value CO INT VALUE 23. 50% Disp06 O2CP value correction O2CP REV A: 1. 0 B: 0.000 C: 0.000 Disp08 EMF/temperature correction EMF REV: 0.0MV TEMP REV: 0.0 Disp01 Return to operation mode in display 2 Operation mode screen Disp11 CP computation mode selection MODE CP OPERATION O2 CO2 O2CO2 Disp12 Lower display item selection DOWN DISPLAY CO2 EMF TEMP Disp13 Thermocouple type/unit selection TC INPUT TC:K UNIT: Disp14 CP value decimal point position CP DOT O2CP: 3 Disp15 EMF/temperature decimal point position PV DOT EMF:0 TEMP:0 Disp16 Transmission output selection TRANS KIND 1:O2CP 2:TEMP Disp18 3:O2CP Disp17 O2CP value transmission scale O2CP TRANS SCALE L:0.000 H:2.000 Disp19 EMF transmission scale EMF TRANS SCALE L: 0.0 H:1500.0 Disp20 Temperature transmission scale TEMP TRANS SCALE L: 0.0 H:1300.0 Disp21 Transmission output filter TRANS FILTER 1:OFF 2:OFF 3:OFF Disp22 Disp23 Disp24 CO/CO2 shift correction CO REV: 0.000 Disp25 Key lock level KEY LOCK LEVEL MODE. LOCK NO.DISP Disp26 Impedance abnormal reset IMPEDANCE ER.RESET OFF ON Disp27 Impedance abnormal determine value IMPEDANCE ER.LEVEL Disp28 Setting parameter initialize PARAMETER INIT OFF 30.0kΩ ON Disp11 Return to CP computation mode selection screen - 8 -

CP value computed from CO2 (type 2) Operation mode Setting mode Disp01 Operation mode in display 2 CO : 50.00 % CO2 : 5.000 % Disp02 Operation mode screen Disp11 CP computation mode selection MODE CP OPERATION O2 CO2 O2CO2 Disp12 Disp20 Temperature transmission scale TEMP TRANS SCALE L: 0.0 H:1300.0 Disp21 Transmission output filter TRANS FILTER 1:OFF 2:OFF 3:OFF Disp03 Disp04 CO internal/external selection CO INT/EXT SELECT Disp06 INT EXT Disp05 CO internal fixed value CO INT VALUE 23. 50% Disp13 Thermocouple type/unit selection TC INPUT TC:K Disp15 EMF/temperature decimal point position PV DOT UNIT: Disp14 CP value decimal point position CP DOT CO2CP:3 TEMP:0 Disp16 Transmission output selection TRANS KIND 1:CO2CP 2:TEMP 3:CO2CP Disp22 Disp23 CO2 input scale upper limit value CO2 SCALE H Disp24 CO/CO2 shift correction CO REV: 0.000 CO2 REV: 0.000 Disp25 Key lock level Disp26 H:2.000 KEY LOCK LEVEL MODE.LOCK NO.DISP Disp07 CO2CP value correction CO2CP REV A: 1.0 B: 0.000 C: 0. 000 Disp17 Disp27 Disp08 EMF/temperature correction TEMP REV: 0.0 Disp01 Return to operation mode in display 2 Disp18 CO2CP value transmission scale CO2CP TRANS SCALE L:0.000 Disp19 H:2.000 Disp28 Setting parameter initialize PARAMETER INIT OFF ON Disp11 Return to CP computation mode selection screen - 9 -

CP value computed from O2 and CO2 (type 2) Operation mode Setting mode Disp01 Operation mode in display 2 1/2 EMF : 1200 MV TEMP : 1200 Disp02 Operation mode in display 2 2/2 CO : 50.00 % CO2 : 5.000 % Disp03 CO2 calculation result CO2 CALCULATION 5.000% Disp04 CO internal/external selection CO INT/EXT SELECT INT EXT Disp05 CO internal fixed value CO INT VALUE 23. 50% Disp06 O2CP value correction O2CP REV A: 1. 0 B: 0.000 C: 0.000 Disp07 CO2CP value correction CO2CP REV A: 1.0 B: 0. 000 C: 0. 000 Disp08 EMF/temperature correction EMF REV: 0.0MV TEMP REV: 0.0 Disp01 Return to operation mode in display 2 1/2 Operation mode screen Disp11 CP computation mode selection MODE CP OPERATION O2 CO2 O2CO2 Disp12 Lower display item selection DOWN DISPLAY CO2CP EMF TEMP Disp13 Thermocouple type/unit selection TC INPUT TC:K UNIT: Disp14 CP value decimal point position CP DOT O2CP: 3 CO2CP:3 Disp15 EMF/temperature decimal point position PV DOT EMF:0 TEMP:0 Disp16 Transmission output selection TRANS KIND 1:O2CP 2:TEMP 3:O2CP Disp17 O2CP value transmission scale O2CP TRANS SCALE L:0.000 H:2.000 Disp18 CO2CP value transmission scale CO2CP TRANS SCALE L:0.000 H:2.000 Disp19 EMF transmission scale EMF TRANS SCALE L: 0.0 H:1500.0 Disp20 Temperature transmission scale TEMP TRANS SCALE L: 0.0 H:1300.0 Disp21 Transmission output filter TRANS FILTER 1:OFF 2:OFF 3:OFF Disp22 CP value deviation alarm CP GAP ALARM Disp24 CO/CO2 shift correction CO REV: 0.000 CO2 REV: 0.000 Disp26 Impedance abnormal reset IMPEDANCE ER.RESET OFF ON Disp27 Impedance abnormal determine value IMPEDANCE ER.LEVEL Disp28 Setting parameter initialize PARAMETER INIT OFF GAP:0.000 Disp23 CO2 input scale upper limit value CO2 SCALE H Disp25 Key lock level H:2.000 KEY LOCK LEVEL MODE. LOCK NO.DISP 30.0kΩ ON Disp11 Return to CP computation mode selection screen - 10 -

5 Parameter list 1. Operation mode Disp No. Operation parameter Initial value Setting range 01 Operation mode display 2 1/2 02 Operation mode display 2 2/2 03 CO2 calculation result 04 CO internal/external selection INT INT Internal set value EXT External analog input value 05 CO internal fixed value 23.50% 0.00 to 50.00 Each type of display *1 1 2 3 - - 06 O2CP value correction A:1.0 B:0.000 C:0.000 07 CO2CP value correction A:1.0 B:0.000 C:0.000 08 EMF/temperature correction EMF: 0.0MV TEMP: 0.0 A ±19.9 B ±0.999 C ±0.999 A ±19.9 B ±0.999 C ±0.999 EMF ±19.9mV Temperature ±19.9 - *2 *1 Displayed parameter is different by selection of mode (CP computation mode selection screen). Type 1 CP value computed from O2 Type 2 CP value computed from CO2 Type 3 CP value computed from O2 and CO2 *2 EMF is not displayed and set when select type 2 (CO2CP value) in CP computation mode. - 11 -

2. Setting mode Disp No. Operation parameter Initial value Setting range 11 CP computation mode selection Type 1 Display CP value computed from O2 in upper of display 1, and display computed result of CO2 in display 2. Type 2 Display CP value computed from CO2 in upper of display 1, and display analog input value of CO2 in display 2. Type 3 Display CP value computed from O2 in upper of display 1, display CP value computed from CO2 in lower of display 1 (depending on setup), and display analog input value of CO2 in display 2 (depending on setup). O2 12 Lower display item selection Type 1 EMF Type 2 - Type 3 CO2CP 13 Thermocouple type/unit selection TC: K UNIT: 14 CP value decimal point position O2CP: 3 CO2CP: 3 15 EMF/temperature decimal point position EMF: 0 TEMP: 0 16 Transmission output selection Type 1 Output 1: O2CP Output 2: TEMP Output 3: O2CP 17 O2CP value transmission scale 18 CO2CP value transmission scale Type 2 Output 1: CO2CP Output 2: TEMP Output 3: CO2CP Type 3 Output 1: O2CP Output 2: TEMP Output 3: O2CP L: 0.000 H: 2.000 L: 0.000 H: 2.000 19 EMF transmission scale L: 0.0 H: 1500.0 20 Temperature transmission scale L: 0.0 H: 1300.0 21 Transmission output filter Output 1: OFF Output 2: OFF Output 3: OFF O2/CO2/O2CO2 CO2CP/EMF/ Each type of display *1 1 2 3 TEMP/CO2 CO2CP selection is not displayed during O2CP mode. CO2 selection is not displayed during O2CO2CP mode. Thermocouple K/N/R/S Unit /F O2CP 1 to 3 CO2CP 1 to 3 CO2CP value is not displayed during O2CP mode. O2CP value is not displayed during CO2CP mode. EMF 0/1 TEMP 0/1 EMF decimal point is not displayed during CO2CP mode. O2CP/CO2CP/ TEMP/EMF CO2CP transmission is not appeared in selection during O2CP mode. O2CP/EMF transmission is not appeared in selection during CO2CP mode. L 0.000 to 0.500 H 0.000 to 2.000 But, L<H L 0.000 to 0.500 H 0.000 to 2.000 But, L<H L 0.0 to 1500.0 H 0.0 to 1500.0 But, L<H - L Input lower limit value to input upper limit value H Input lower limit value to input upper limit value But, L<H Scale L and H are linked to thermocouple input range K/N 0.0 to 1300.0 R/S 0.0 to 1700.0 OFF, 1 to 10 seconds Available to set transmission 1 to 3 individually OFF for every output, set 1 to 10 seconds 22 CP value deviation alarm 0.000 0.000 to 0.999 - - 23 CO2 input scale upper limit value 2.000 0.000 to 5.000-24 CO/CO2 shift correction CO: 0.000 CO correction ±0.099 CO2: 0.000 CO2 correction ±0.099 25 Key lock level MODE. LOCK MODE. LOCK/NO. DISP MODE. LOCK Display mode, but no change NO. DISP No mode display 26 Impedance abnormal reset OFF OFF/ON Automatically change to OFF after ON 27 Impedance abnormal determine value 30.0kΩ 0.0 to 30.0kΩ 28 Setting parameter initialize OFF OFF/ON Return to cursor OFF after initialize - 12 -

6 External dimensions CO input + CO2 input (with terminal cover) Transmission output 1 + transmission output 2 O2 input + contact input Unit: mm Transmission output 3 Input terminal Alarm terminal Ground Power supply [Terminal arrangement] Thermocouple input K, N, R, S Alarm output CO input + CO2 input Transmission output 1 1 to 5V Transmission output 2 1 to 5 V - 13 - O2 input + Contact input Transmission output 3 0 to 10mV 1 12 CO 19 Output 2 26 Impedance check 35 Output 3 2 TC 13 CO 20 Output 2 27 CP shift 36 Output 3 3 TC 14 21 Output 1 28 PV hold 4 15 CO2 22 Output 1 29 COM 5 16 CO2 23 30 6 Impedance abnormality 17 24 31 7 CP deviation alarm 18 25 32 8 COM 33 O2 34 O2

7 Error and warning 1. Error Display Content Cause/action on error SYSTEM ERROR NO.01 CALIBRATION ERROR SYSTEM ERROR NO.02 A/D COUNT : TC SYSTEM ERROR NO.03 A/D COUNT : RJ SYSTEM ERROR NO.04 A/D COUNT : EMF SYSTEM ERROR NO.05 A/D COUNT :CO/CO2 Calibration data error A/D conversion error for thermocouple A/D conversion error for RJ A/D conversion error for EMF A/D conversion error for CO/CO2 Calibration data is destroyed. Contact your dealer or our nearest office. A/D conversion of analog input is not functioning properly. When this error is displayed after pressing key, turn off the power once and turn on the power. If the error is not improved, contact your dealer or our nearest office. 2. Warning Display Content Cause/action on error WARNING NO.10 KEY LOCK Key lock Display for tying to change during key lock. Reset the key lock for change. (Press key more than 3 seconds in operation mode.) WARNING NO.32 INVERTED Z>S Transmission scale range error Display for L H in transmission scale. Check the range. - 14 -

8 Parameter sheet Date: Number: 1. Operation mode (Parameter sheet 1/2) Each type Disp Operation parameter Set value Initial value Setting range of display *1 No. 1 2 3 01 Operation mode in display 2 1/2 02 Operation mode in display 2 2/2 - - 03 CO2 calculation result 04 CO internal/external selection INT INT Internal value EXT External analog input value 05 CO internal fixed value 23.50% 0.00 to 50.00 06 O2CP value correction A: 1.0 B: 0.000 C: 0.000 A ±19.9 B ±0.999 C ±0.999 07 CO2CP value correction A: 1.0 B: 0.000 C: 0.000 A ±19.9 B ±0.999 C ±0.999-08 EMF/temperature correction EMF: 0.0MV TEMP: 0.0 EMF ±19.9mV Temperature ±19.9 *2 *1 Displayed parameter is different by selection of mode (CP computation mode selection screen). Type 1 CP value computed from O2 Type 2 CP value computed from CO2 Type 3 CP value computed from O2 and CO2 *2 EMF is not displayed and set when select type 2 (CO2CP value) in CP computation mode. - 15 -

Disp No. 2. Setting mode Operation parameter Set value Initial value 11 CP computation mode selection O2 Type 1 Display CP value computed from O2 in upper of display 1, and display computed result of CO2 in display 2. Type 2 Display CP value computed from CO2 in upper of display 1, and display analog input value of CO2 in display 2. Type 3 Display CP value computed from O2 in upper of display 1, display CP value computed from CO2 in lower of display 1 (depending on setup), and display analog input value of CO2 in display 2 (depending on setup). 12 Lower display item selection Type 1 EMF Type 2 - Type 3 CO2CP 13 Thermocouple type/unit selection TC: K UNIT: 14 CP value decimal point position O2CP: 3 CO2CP: 3 15 EMF/temperature decimal point position EMF: 0 TEMP: 0 16 Transmission output selection Type 1 Output 1: O2CP Output 2: TEMP Output 3: O2CP 17 O2CP value transmission scale 18 CO2CP value transmission scale Type 2 Output 1: CO2CP Output 2: TEMP Output 3: CO2CP Type 3 Output 1: O2CP Output 2: TEMP Output 3: O2CP L: 0.000 H: 2.000 L: 0.000 H: 2.000 19 EMF transmission scale L: 0.0 H: 1500.0 20 Temperature transmission scale L: 0.0 H: 1300.0-16 - O2/CO2/O2CO2 CO2CP/EMF/ Date: Number: (Parameter sheet 2/2) Each type Setting range of display *1 1 2 3 TEMP/CO2 CO2CP selection is not displayed during O2CP mode. CO2 selection is not displayed during O2CO2CP mode. Thermocouple K/N/R/S Unit /F O2CP 1 to 3 CO2CP 1 to 3 CO2CP value is not displayed during O2CP mode. O2CP value is not displayed during CO2CP mode. EMF 0/1 TEMP 0/1 EMF decimal point is not displayed during CO2CP mode. O2CP/CO2CP/ TEMP/EMF CO2CP transmission is not appeared in selection during O2CP mode. O2CP/EMF transmission is not appeared in selection during CO2CP mode. L 0.000 to 0.500 H 0.000 to 2.000 But, L<H L 0.000 to 0.500 H 0.000 to 2.000 But, L<H L 0.0 to 1500.0 H 0.0 to 1500.0 But, L<H L Input lower limit value to input upper limit value H Input lower limit value to input upper limit value But, L<H Scale L and H are linked to thermocouple input range K/N 0.0 to 1300.0 R/S 0.0 to 1700.0 OFF, 1 to 10 seconds Available to set transmission 1 to 3 individually OFF for every output, set 1 to 10 seconds - 21 Transmission output filter Output 1: OFF Output 2: OFF Output 3: OFF 22 CP value deviation alarm 0.000 0.000 to 0.999 - - 23 CO2 input scale upper limit value 2.000 0.000 to 5.000-24 CO/CO2 shift correction CO: 0.000 CO correction ±0.099 CO2: 0.000 CO2 correction ±0.099 25 Key lock level MODE. LOCK MODE. LOCK/NO. DISP MODE. LOCK Display mode, but no change NO. DISP No mode display 26 Impedance abnormal reset OFF OFF/ON Automatically change to OFF after ON 27 Impedance abnormal determine value 30.0kΩ 0.0 to 30.0kΩ 28 Setting parameter initialize OFF OFF/ON Return to cursor OFF after initialize

新栄熱計装株式会社 4-20-3 Meguro Honcho, Meguro-ku, Tokyo 152-0002 Telephone: 03-3711-7346 Facsimile: 03-3710-4103 Printed in Japan