Single Point Flow Monitor SW118 SW119

Similar documents
Mechanical flow switch for On/Off control

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

SERIES 400 SERIES 620

Panel-mounting thermostats, type series EM

EXPlora. Introduction

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Bimetal Temperature Switch

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Pressure transmitter COMPACT IO-Link,

Filters for Power Lines (Low Leakage Current)

Selection matrix for electronic pressure switches

02/11/2015

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Panel-mounting Thermostats EM Series

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

LCS 2 RJ 45 Cat. 6A HD panels and units

Signet 2250 Hydrostatic Level Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ALLEN BRADLEY TIMING RELAY

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Panel-Mounted Thermostat

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnecraft Power Relays

Proportional output thumbwheels - sprung to centre

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

LD OEM/LD PDS/LD PeCo

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Photoelectrics Through-beam Type PA18C.T..., DC

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Flexibility and Safety. BERNSTEIN safety hinge switches

Process Transmitter RMA 422

Pulse Counters, electromechanical

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Linear flow controls VFC Linear flow controls with actuator IFC

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

PROPORTIONAL VALVES Sentronic plus

TUC: Universal thermostat

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

TFRN Industrial RTD temperature sensor. CombiTemp TM

Linear flow control with actuator IFC

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor


Linear encoders without bearings incremental System for linear motion feedback

Connecting cables NEBS, for sensors

TFRN Industrial RTD temperature sensor. CombiTemp TM

Surface-mounting thermostats ATH series

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Modular Lube Lubrication Systems System Controls

Photoelectric Sensors E3F2

TFRH Hygienic RTD temperature sensor. CombiTemp TM

IONIVAC Transmitter ITR 90

DMP 331i / DMP 333i LMP 331 i

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Kuhnke Technical Data. Contact Details

LCS2 Cat. 6 RJ 45 Patch panels and units

Horn loudspeaker, Ex proof, short/long flare

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

High performance circuit breakers

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Absolute Encoders Multiturn

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

2291 Guided Wave Radar Level Transmitter

Capacitance Limit Detection nivotester FTC 420/421/422

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

AS09..S 3-pole Contactors - Spring Terminals

Solenoid valves VZWD, directly actuated

Coils for solenoid valves

TFR5 Room or outdoor temperature sensor. CombiTemp TM

HARTING Ethernet cabling cables and connectors, 4 wire

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

APPLICATIONS. Automatic warehouse. Trasportation lines

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

The full range of performance

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Transcription:

SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either no delay, or with a 60 s switch-on delay or a 0 s change over delay. Features Adjustable to a wide range of flow rates No moving parts in the flow Operation largely independent of pipe diameter LED status indication Fast response time MIN or MAX switch point Suitable for water, oil and air SW8 SW9 General data TECHNICAL DATA SW8 in a compact housing Suitable for liquids, gases liquids, gases Monitoring function SW9 for surface mounting flow rate switch point (MIN or MAX) switch point (MIN or MAX) wire break/circuit failure standard Anzeigeart flow rate dual colour LED dual colour LED Temperaturbereich Electrical data medium -25... +70 C/-3 +58 F -40... +00 C/-40 +22 F electronic control unit -25... +50 C/-3 +22 F -25... +50 C/-3 +22 F AC 230, 5, 24 V 50/60 Hz +0 %, -5 % AC 230, 5, 24 V 50/60 Hz +0 %, -5 % DC 24 V ±0 % DC 24 V ±0 % Power consumption approx.,2 VA approx.,2 VA Relay Flow monitoring flow rate Flow response level adjustment (steplessly by means of a potentiometer) SPDT contact AC 250 V/DC 30 V, max. load 5 A Overvoltage category II gases: 0,5... 50 m/s /.64 64 fps liquids: 0,0... 4 m/s /.0328 3. fps Repeatability () ± 3 % ± 3 % Response delay (2) SPDT contact AC 250 V/DC 30 V, max. load 5 A Overvoltage category II gases: 0,5... 50 m/s /.64 64 fps liquids: 0,0... 4 m/s /.0328 3. fps 2 s with water, 4 s with oil, 7 s with air selectable delay (no delay, 60 s switch-on delay or 0 s change over delay) Switch point drift through temperature change of the medium approx. ± 0,7 %/ C / ±,26 %/ F approx. ± 0,7 %/ C / ±,26 %/ F Mechanical data Type and size of monitoring head G/2A, /2 NPT G/2A, /2 NPT, push-in type MKV Pressure resistance of monitoring head (3) 00 bar/450 psi 00 bar/450 psi Degree of protection Materials Housing dimensions Cable length to monitoring head monitoring head IP67 IP67 (connector) electronic control unit IP65 IP65 fitting stainless steel.457/aisi 36Ti stainless steel.457/aisi 36Ti sensor stainless steel.457/aisi 36Ti stainless steel.457/aisi 36Ti seals laser welded laser welded electronic control unit housing ABS ABS cover polycarbonate polycarbonate 80,5 x 82,5 x 55 mm/ 3.7 x 3.25 x 2.7 in. x 80 x 55 mm/ 4.72 x 3.5 x 2.7 in. standard - 2 m/6.56 ft (6 x 0.4 mm 2 /AWG 26) max. length - 00 m/328 ft () Of the set value, at constant temperature and flow conditions, and stable thermal conductivity. (2) Delay with the switch point set to m/s / 3.28 fps ftand the flow at 2 m/s / 6.56 fps, after a sudden complete stop. (3) Admissible operating pressure to DIN 240, measured at the max. admissible temperature (= max. medium temperature) 09 5

SW8 SW9 Ordering information SW8 Dimensions SW8 SW8 in a compact housing, with integral monitoring head AC 230 V 50/60 Hz (standard) AC 5 V 50/60 Hz AC/DC24 V (AC: 50/60 Hz) Process connection MK G/2A (standard) MK /2 NPT Monitoring head material ST only NPT thread ST2 only G/2A (standard) SW8 - AC230V - MKG/2A - ST2 ordering example 82.5 3.25 80.5 3.7 SW27.06 in. PG3.5 55 2.7 4.55 G /2A 4.55 NPT /2" Ordering information SW9 67.5 2.66 36.42 67.5 2.66 36.42 Electronic Control Unit SW9 for surface mounting, with separate monitoring head AC 230 V 50/60 Hz (standard) AC 5 V 50/60 Hz AC/DC24 V (AC: 50/60 Hz) SW9 - AC230V ordering example Connection diagram SW8 Monitoring Head MK thread-mounted MIN/MAX switch V V2 medium switch delay switch V, V2 V V2 Fitting size MK G/2A (standard) MK /2 NPT Material ST only NPT thread ST2 only G/2A (standard) MK G/2A - ST2 ordering example MIN MAX MIN or MAX L N G R 2 3 4 5 LED MIN/MAX flow potentiometer II III I V V2 V V2 without delay switch-on delay 60 s change-over delay 0 s Monitoring Head MKV push-in type (see separate page) 2 3 4 5 L N 0 I mains relay relay not energized (LED red) 0 = medium to be monitored is in the unadmissible range I = medium to be monitored is in the operating range SW9 Cable type 2 with connectors Flow ranges Cable and plug between monitoring head and control unit 7-pole round connector, PVC insulated cable type LiYCY 6x0.4 mm 2 (AWG 26), RAL 7032 Available cable lengths...m 2 m, 3 m, 5 m, 8 m, 0 m, 5 m, m, 25 m, 30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m and 00 m (up to max. 00 m/328 ft) liquid - 2 m/6.56 ft ordering example gases See data sheet monitoring head MKV. 0.0 0. 0 00 000 flow rate of the medium in m/s 6 09

SW8 SW9 Dimensions Electronic Control Unit SW9 Dimensions Monitoring Head MK SW9 50.97 PG9.06 in. cable 08.5 4.27 G /2 A 4.72 4 36.55.42 sensors rotated by 90 4.57.06 in. cable 23.906 80 3.5 ø4.2.65 PG9 55 2.7 NPT /2" 4 36.55.42 sensors rotated by 90 Connection diagram SW9 MIN/MAX switch V V2 delay switch V, V2 mains relay L N 2 3 4 5 MIN G R MAX I III II 3 4 5 6 7 8 9 yellow green brown black white grey shield LED MIN/MAX 54 3 26 monitoring head V V2 V V2 V V2 without delay switch-on delay 60 s change-over delay 0 s flow potentiometer medium switch MIN or MAX 2 3 4 5 L N 0 I mains relay relay not energized (LED red) 0 = medium to be monitored is in the unadmissible range I = medium to be monitored is in the operating range All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 09 7

SW9 Monitoring head MKV-3 SW9 Calorimetric monitoring head Extended calorimetric monitoring head with variable immersion depth for use in larger pipe sizes (DN50 plus). Caution: Fix with locking set 0 (see accessories). Features Temperature range: -40... +00 C/-40 +22 F Material: stainless steel.457 MKV-3 Technical data Type of head Nominal shank dia. Length of shank Length of sensor Suitable for (medium) push-in 8 mm/.709 in. without thread 300 mm/.8 in. 4 mm/.55 in. liquids and gases Temperature range *) -40... +00 C/-40 +22 F (of medium) Pressure resistance () (of monitoring head) Pressure resistance () (installation) Degree of protection (2) 00 bar/450 psi 25 bar/363 psi (with threaded installation bush) IP67 Material stainless steel.457 Cable to electronic unit Weight 2 m/6.56 ft (up to max. 00m/328 ft) 70 g/.57 lb () Admissible operating pressure DIN 240, measured at max. temperature (= max. medium temperature) (2) with mating connector *) max. +80 C/+76 F in the connector area Ordering information Type MKV Push-in type monitoring head with calorimetric sensors Monitoring head design 3 Monitoring head with variable immersion depth Medium X Liquids and gases Material of areas exposed to medium M stainless steel.457 Process connection 00 without flange; see accessories for cable gland**) Length of shank/thread L30 300 mm/.8 in. (standard) other lengths upon request Electrical connection E30 round connector Rd24, 7-pole (plug and cable to order separately) Certification T0 without certificate (standard) *) Specification of medium xxx MKV - 3 X M 00 L30 E30 T0 -... ordering example *) for detailed information please see section 0. **) see next page. Dimensions 4 L = 300 52.5.55 L =.8 2.07 ø38 ø.47 Rd 24 Rd.945 3 4 2 5 6 flow direction ø8 ø.709 SW 5 SW.590 8 09

SW9 cable types and accessories (MKV-3) Cable type 2 with connectors Cable between push-in type monitoring head MKV and flow monitor SW9. SW9 Cable type 2 with connectors Cable and plug - 2 m/6.56 ft See data sheet monitoring head MKV. between monitoring head and control unit 7-pole round connector, PVC insulated cable type LiYCY 6x0.4 mm 2 (AWG 26), RAL 7032 Available cable lengths...m 2 m, 3 m, 5 m, 8 m, 0 m, 5 m, m, 25 m, 30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m and 00 m (up to max. 00 m/328 ft) ordering example Technical data Cable type 2 Features: flexible, fully shielded, electrical and thermal properties at + C/+68 F Conductor resistance: Insulation resistance: Operating voltage: Withstand voltage: Max. load: < 3 Ω/km > 0 MΩ max. 350 V 0 V.5 A Temperature range -0... +80 C/+4 +76 F (processing and operation) -30... +80 C/-22 +76 F (transport and storage) Threaded installation bush 0Z22Z00096 Teflon sealing ring 0Z22Z00097 Accessories Locking set 0 0Z22Z0004 front sealing ring union nut threaded installation bush rear sealing ring 2 3 R 3/4 Ø8 Ø.708 Ø8 Ø.708 9.748.06 in. 52 2.05 SW 29.4 in. Suitable up to 25 bar/2.5 MPa/363 psi if used with stainless steel MK monitoring head. (Observe instructions for installation.) Caution: Stainless steel ring is designed to cut into monitoring head. Pressure resistant to 25 bar/2.5 MPa/363 psi. Teflon ring can only be used from 0 to 2 bar/0,2 MPa/29 psi. Please observe user manual and safety guidelines! chain 4 x 32 DIN 5685 (approx. m/3.28 ft) 2 catch for chain NG 5 3 clip with screw and nuts DN5 to DIN 850 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 09 9