BREAK-TW-V.4/4, BREAK--V.4/4 BOX DIN RACK IP56 Optoconverters are designed to transfer videosignal and or data. I FM modulation I AGC optical loss I Universal for MM and SM fibres I Up to 3 independent outputs I Overvoltage protections I Current limiter in supply I FIBRE LOSS relay ORDERING NAME CODE SUPPLY BREAK-TW-V.4/4-BOX/12-24 1-532-254 12/24 VDC-AC BREAK-TW-V.4/4-DIN/12-24 1-532-354 12/24 VDC-AC BREAK-TW-V.4/4-RACK 1-532-544 RACK/3U-SU BREAK-TW-V.4/4-IP56 1-532-614 230VAC BREAK-TW-V.4/4-IP56/12-24 1-532-654 12/24 VDC-AC BREAK--V.4/4-BOX/12-24 1-632-255 12/24 VDC-AC BREAK--V.4/4-DIN/12-24 1-632-355 12/24 VDC-AC BREAK--V.4/4-RACK 1-632-545 RACK/3U-SU Accessories - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards IN BREAK-... (jumper EXP is ON) BREAK- PLACEMENT OF THE BOARDS IN 19 RACK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 BREAK-RACK/3U-SU Note: only cards can be expanded REV:201010 www.metel.eu 1/7
BREAK-TW-V.4/4, BREAK--V.4/4 Parameter Value Unit Note Video Input / output level 1 Vpp adjust. 0.5-1.5Vpp Overvoltage protections input: coarse + fine lightning arresters + transils output: fine transils Bandwidth 10-7M Hz Ratio signal / noise min. 60 db Data Supported formats - full duplex - 2 pairs - half duplex - 1 pair Speed DC - 115.2 Kbps Optics Output optical power 14 to 8 / 10 to 0 dbm SM / MM Optical fibres 1x SM 9/125 - SC connectors µm max. 20 km 1x MM 50(62.5)/125 - SC con. µm max. 6 km Sensitivity 31 dbm SM / MM ATTENTION: class 1 LASER PRODUCT COMPLIES WITH 21 CFR 1040.10 and 1040.11 (EN 60825-1-1) - Relay FIBRE LOSS NC contact - optical power loss signalling Power Supply.../12-24 12VDC-AC / 24VDC-AC (11-30VDC/10-30VAC) max. 3VA RACK BREAK-RACK/3U-SU max. 3VA IP56 230VAC max. 8VA Protections overvoltage / current fine* / reversible Environment Operational range 40...+70 C temperature of environment Humidity max. 95 (non-condensing) % Mechanical Dimensions - w / h / l BOX: 107 x 23 x 140 mm with connectors Parameters DIN: 107 x 53 x 140 mm with connectors RACK: width 1slot / 3U - up to 20 cards to rack BREAK-RACK/3U - up to 18 cards to rack BREAK-RACK/3U-SU IP56: see outdoor housings IP56-PG7 Weight typ. 0.20 / 0.23 / 0.15 / 1.80** kg BOX / DIN / RACK / IP56** The producer retains the right to change any technical parameters without previous announcement. *fine + coarse at TW-V.4/4-IP56 (optionally lightning arrester) **Including supply transformer 230V/12V-14VA SAFETY INSTRUCTIONS - devices can be installed only by persons that have a valid licence to work with electrical devices under voltage - revision of electrical connection before being put into the operation is required for modifications with 230VAC power supply - in case of a failure, immediately disconnect the device from supply and send it to METEL s.r.o. for revision REV:201010 www.metel.eu 2/7
BREAK-TW-V.4/4, BREAK--V.4/4 Installation and Setting 1. Converter mounting BOX a IP56 - to flat surface DIN - to a DIN35 rail RACK - to a 19 rack RACK/3U 2. Connect supply Modification RACK - by pushing it into the 19 frame Modification.../12-24 GND(PE) +12/24VDC VDC GND(PE) * 12VAC x 12VAC Modification...- IP56 - connect 230VAC to the power transformer 3. Ground overvoltage protections (TW) VAC Mode - full duplex / 2pairs - Z GND (FTP shielding) - B After the previous steps the optoconverters are ready to use LED LED POWER OK x LED SYNC OK x LED FIBRE LOSS x OPTO RX OK LED TX INACTION DATA TX TWIST LED RX INACTION DATA RX TWIST Alternative Setting Videosignal output level adjusting Default setting: Vout () = Vin (TW) Vout=0.5-1.5Vpp 1.5-2.5mm 2 * - video otputs splitter 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 4. Connect optic fibres RACK/3U-SU TW SM - 1x 9/125µm or MM - 1x 62.5(50)/125µm IN jumper EXP 5. Connect videosignal 1Vpp TW: IN (input) : (output) 6. Connect (422) Mode - half duplex / 1pair HIGH Impedance Y/Z 120Ω - RELAY FIBRE LOSS OPTO RX OK = closed OPTO RX LOW = opened - Z GND (FTP shielding) - B REV:201010 www.metel.eu 3/7
BREAK-TW-V.4/4, BREAK--V.4/4 TW-V.4/4-BOX and DIN/12-24 -V.4/4-BOX and DIN/12-24 IN OPTO WDM IN/ LASER CLASS1 Z GND B IN/ 12/24VDC OPTO WDM IN/ LASER CLASS1 RELAY Z GND B IN/ 12/24VDC BREAK-TW-V.4/4-BOX12-24 O MM O SM BREAK--V.4/4-BOX12-24 O MM O SM REV:201010 www.metel.eu 4/7
BREAK-TW-V.4/4, BREAK--V.4/4 MM SM RX TX FIBRE LOSS SYNC POWER TW-V.4/4 NOTE: MM SM SYNC RX TX FIBRE LOSS POWER TW-V.4/4-RACK -V.4/4-RACK -V.4/4 NOTE: REV:201010 www.metel.eu 5/7
BREAK-TW-V.4/4, BREAK--V.4/4 Specification of custom-made modification: BREAK-TW-V.4/4-IP56C This custom/made modification of optical converters video + duplex data /422 is designed above all for installation to close proximity of rotating cameras in both outdoor and industrial environment. Plastic box with IP56 cover level (in accordance to IEC 60529) contains: 1x optical converter BREAK-TW-V.4/4-BOX/12-24 1x (optical) splice cassette for 12 fibres 1x toroid 100W transformer 230VAC/24VAC. The transformer output is adjusted for supplying of one rotating camera up to the gain of 80W. ORDERING NAME CODE SUPPLY BREAK-TW-V.4/4-IP56C 1-532-754 230VAC SAFETY INSTRUCTIONS - devices can be installed only by persons that have a valid licence to work with electrical devices under voltage - revision of electrical connection before being put into the operation is required for modifications with 230VAC power supply - in case of a failure, immediately disconnect the device from supply and send it to METEL s.r.o. for revision Parameter Value Unit Note Video Input 1 Vpp Overvoltage protection input: coarse + fine lightning arresters + transils Bandwidth 10-7M Hz SNR min. 60dB Data Supported formats - full duplex - 2 pairs / - half duplex - 1 pair Speed DC - 115.2 Kbps Optics Output optical power 14 to 8 / 10 to 0 dbm SM / MM Optical fibres 1x SM 9/125 - SC connectors µm max. 20 km 1x MM 50(62.5)/125 - SC con. µm max. 6 km Sensitivity 31 dbm SM / MM ATTENTION: class 1 LASER PRODUCT COMPLIES WITH 21 CFR 1040.10 and 1040.11 (EN 60825-1-1) Power Supply BREAK-TW-V.4/4-BOX/12-24 12VDC-AC / 24VDC-AC (11-30VDC/10-30VAC) max. 3VA Protections overvoltage / current fine* / reversible BREAK-TW-V.4/4-IP56C 230VAC Environment Operational range 40...+70 C temperature of environment Mechanical Dimensions - w / h / l 315 x 420 x 130 mm Parameters Weight typ. 3.5 kg The producer retains the right to change any technical parameters without previous announcement. Installation and Setting 1. Converter mounting Screw the box to flat surface or attach it to a column using HOLDER-PG10 holder. 2. Converter connection Connect optical cable to (optical) splice cassette and weld SC patch cords. Fibre type (MM/SM) of the patch cord must correspond to the type of fibre in the optical cable. After welding and measuring connect the patch cord to SC connector of the converter. Port /422 is pre-set to half duplex (terminals and Z). In case of using full duplex unscrew the upper lid and switch the DIP switch to position (see page 3). Then connect data cables and video signal to the converter inputs. Connect 230VAC to the input of toroid transformer. 3. Verification of converter functioning - yellow LED POWER is on after the connection of power supply - red LED FL (FIBRE LOSS) is off after the connection of a BREAK--V.4/4 receiver - green LED SYNC is on after the connection of video signal to the input - activity of data port is indicated by blinking LED Tx and Rx If all LEDs behavior corresponds to the description above proceed to initial revision of connection and afterwards to continuous use. REV:201010 www.metel.eu 6/7
BREAK-TW-V.4/4, BREAK--V.4/4 Specification of custom-made modification: BREAK-MTW-V.4/4-BOX/12-24 This custom-made modification of optical converters is a miniaturized modification of BREAK-TW-V.4/4. Its reduced dimensions predetermine this modification for installation directly to camera covers. All electrical and optical parameters are therefore identical to the original modification. ORDERING NAME CODE SUPPLY BREAK-MTW-V.4/4-BOX/12-24 1-532-854 12/24 VDC-AC Parameter Value Unit Note Environment Operational range 40...+70 C temperature of environment Mechanical Dimensions - w / h / l 54 x 45 x 90 mm with connectors Parameters Weight typ 0.16 kg The producer retains the right to change any technical parameters without previous announcement. INPUT RS 485/422 POWER SUPPLY SC OPTICAL INPUT / PUT FL Tx IN HIGH GND 12/24V DC + AC Class 1 Laser Product Complies with 21 CFR 10410.10 and 1040.11 2 ON PWR Rx 120R -B GND -Z RS 422 RS 485 Installation and Setting 1. Converter connection Port /422 is pre-set to half duplex (terminals and Z). In case of using full duplex switch the DIP switch to position (see picture). Then connect data cables, video signal and MM or SM optical cable to the converter inputs. 2. Verification of converter functioning - yellow LED POWER is on after the connection of power supply - red LED FL (FIBRE LOSS) is off after the connection of a BREAK--V.4/4 receiver - activity of data port is indicated by blinking LED Tx and Rx If all LEDs behavior corresponds to the description above the converter is ready for continuous use. REVISION HISTORY: 201003 new corporate colours 201004 custom-made modifications added REV:201010 www.metel.eu 7/7