Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Similar documents
2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Operating instructions Electronic preset counter Type series 717

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

EVENT INPUT/OUTPUT MODULE [PUME]

Fibre Optic Modem ODW-622

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Rack mounted telephone- and leased line modem for industrial applications

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Wall-/Pipe-Mount Level Indicator

SY-HDBT-100 Extender Set

Fibre Optic Modem ODW-611

Fibre optic router for TP/FT-10 LRW-112PP

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

ODW-621. RS-232 Point-to-point applications

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

INSTALLATION & USER GUIDE

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

MICROPROCESSOR CALCULATION MODULE - S2000

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

LONWORKS Fibre Optic Router

Process transmitter RMA422

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

SY-HDBT-SLIM-100S Extender Set

Preset counters, electronic

Installation Guide. HDMI 4x1 Switcher

Multifunction devices

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Electrical connection

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

LONWORKS Fibre Optic Converter

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Process Transmitter RMA 422

Configuration Vestas VMP3500

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Electrical connection

Single cable multiswich programmer PC102W

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Operating Instructions

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

48x24. Options ORDER NUMBER OF TYPE PFL B

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Pulse Counters, electronic

Electrical connection

OPERATING MANUAL. DMX / Constant Current Dekoder 3706A-H Mk1 RDM

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Electronic Pulse Counter Combination device

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

I N S T R U C T I O N D A T A

Intelligent Security and Fire Ltd

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

Material: Weight: IP Rating: Cable: Connector:

02/11/2015

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

Electrical connection

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

SPACESCAN SERIES SS 02

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LCD Thermometer / Clock S No. 1253

USER MANUAL Full HD Widescreen LED Monitor L215ADS

SY-MS121 SY-MS121-AP

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Model /29S RF Splitter

Absolute Encoders Multiturn

DMP 331i / DMP 333i LMP 331 i

02/11/2015

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Operating Instructions

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Photoelectrics Through-beam Type PA18C.T..., DC

Synchro System PHOTO NOT AVAILABLE. Description. Applications. Features

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

MULTIS L72. Operating instructions

SERCOS TSX CSY 84 Module V

DCL9AW. User Manual. English

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

Transcription:

S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings - Digital Inputs - Frontal Panel Leds Signalling s - Factory Settings - Module Layout - Decomissioning and Disposal Z-D-IN RS485 Modbus Module 5 Digital Inputs SENECA s.r.l. Via Austria, 26 35127 PADOVA ITALY Tel. +39.049.8705355-8705359 - Fax +39.049.8706287 For manuals and configuration software, see www.seneca.it This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the present documentation refers to products and technologies described in it. All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision. MI002056-E ENGLISH 1/8

General Specifications 5 digital inputs with self-powered 16 V shared negative pole. 2 Removable terminals with section of 2.5 mm Input protection by 600 W/ms TVS transient current suppressors. 5 inputs with 16 bit totalizer with 100 Hz max. frequency, with settable filter. Possibility to set the input n 5 to 32 bit fast totalizer, max frequency 10 khz. Possibility of ON-LINE configuration. RS485 serial communication with Modbus-Rtu protocol, maximum 32 nodes. 1500 V input insulation with respect to the remaining low voltage circuits. Power supply and serial connection wiring facilitated by means of a bus that can be housed in the DIN guide. Insertion and extraction from bus without: interruption to communication or system power supply Communication times below 10 ms (@ 38400 Baud). Connection distance up to 1200 m. DIP-Switch settings for Modbus speed and address, and for RS485 line termination. All the totalizers are saved in non-volatile memory (Fe-RAM). Input type Number of Channels 5 (4+1) Technical Specifications Inputs Reed, Contact, Proximity PNP, NPN (with external resistor) etc... Maximum Totalizers Frequency 10 khz only for channel 5 (if configured) UL (state OFF) UH (state ON) Absorbed Current Voltage 0 10 V, I < 2 ma 12 30 V, I > 3 ma 3 ma (for each input) Power Supply 10 40 V ; 19-28 V 50 60 Hz Consumption Typical: 1,5 W @ 24V, Max: 2,5 W Temperature Humidity Altitude Storage Temperature Protection degree Environmental Condition -10 +65 C (-10 +55 C UL) 30 90% a 40 C non condening Fino a 2000 m a.s.l. -20 +85 C IP20 MI002056-E ENGLISH 2/8

Connections Removable 3-way screw terminals, 5 mm pitch Rear IDC10 connector for DIN 46277 rail Dimensions Box Dimensions / Box L: 100 mm; H: 112 mm; W: 17,5 mm PA6, Black 2.. 11 Isolations Ingressi Digitali. IDC10 RS485. Standards The module complies with the following standards: EN61000-6-4 (electromagnetic emission, industrial environment). EN61000-6-2 (electromagnetic immunity, industrial environment). EN61010-1 (safety). Alimentazione IDC10 1500V ADDITIONAL NOTES : Use in Pollution Degree 2 Environment. Power Supply must be Class 2. A max 2.5 A rated fuse shall be installed near the module. Installation Rules The module is designed to be installed in vertical position on a DIN 46277 rail. In order to ensure optimum performance and the longest working life, the module(s) must be supplied adequate ventilation and no raceways or other objects that obstruct the ventilation slots. Never install modules above sources of heat; we recommend installation in the lower part of the control cabinet. MI002056-E ENGLISH 3/8

Inserting on the DIN rail As illustrated in the next figure: 1) Insert the rear IDC10 connector on a DIN rail free slot (the insertion is univocal because the connectors are polarized). 2) Tighten the two locks placed at the sides of the rear IDC10 connector to fix the module. Electrical Connections Power Supply and MODBUS Interface Power Supply and Modbus interface are available by using the bus for the Seneca DIN rail, by the rear IDC10 connector or by Z-PC-DINAL1-17.5 accessory. RS485 GND RS485 A RS485 B Power Supply AC / + Power Supply AC / - 1 IDC 10 Rear Connector (IDC10) The figure show the meaning of the IDC10 connector pins, when the signals are provided directly through this connector. Z-PC-DINAL2-17.5 Accessory Use When Z-PC-DINAL2-17.5 accessory is used the signals are provided by terminal blocks. The figure shows the meaning of the terminals and the position of the DIPswitch (present on each DIN rail supports listed on Accessories list) for network termination (not used in case of Modbus network). GNDSHLD: Shield to protect the connecting cables signal against interference (recommended). 19-28 V 10-40 V 2 3 Power Supply As an alternative to the bus connection by Z-PC-Dinx it is also possible use the terminals 2-3 to provide power supply to the module. The upper limits must not be exceeded, to avoid serious damage to the module. If the power source is not protected against overload, then a safety fuse with a maximum value of 0.5 A must be installed in the power supply line. MI002056-E ENGLISH 4/8

DIGITAL INPUTS REED, PROXIMITY PNP, NPN, and contact-type sensor can be connected to the input terminals. The terminal 12 (+16V) is able to deliver the power supply directly for this sensors. All the inputs are connected in shared connection to terminal 1 GND. The flowing current through a closed input is approx. 3 ma. + Z-D-IN-1 16V 12 7 8 9 10 11 12 #1 7 #2 8 #3 9 #4 10 #5 11 12 PNP #1 7 #2 8 #3 9 #4 10 #5 11 NPN R=1k5 #1 #2 #3 #4 #5 1k5 1k5 1k5 1k5 Input #1: 0 100 Hz Input #2: 0 100 Hz Input #3: 0 100 Hz Input #4: 0 100 Hz Input #5: 0 100 Hz input #5: 0 10 khz 1 1 1 Modbus connection rules 1) Install the modules on the DIN rail (max 120). 2) Connect the remote modules using cables of proper length. Data about the cable lengths are provided on the following table: -Bus Length: Modbus network Maximum length as a function of the Baud Rate. Is the cable length to connect the two modules with bus terminators (see Scheme 1). -Derivation Length: Derivation line Maximum length as a function of the Baud Rate (see Scheme 1). Bus length Derivation length 1200 m 2 m Scheme 1 Terminator Module1 Module4 Module3 DL Terminator Module2 Module5 Bus Length DL = Derivation Length GND B(-) A(+) 4 5 6 MODBUS RS485 RS485 communication connection with the Modbus master system as an alternative to the Z-PC-DINx bus. Note: the indication of the RS485 connection polarity isn't standardised and in some masters may be reversed. MI002056-E ENGLISH 5/8

For the best performances, the use of special shielded cables is suggested (BELDEN 9841 cable for example). DIP-switches settings The DIP-switches positions define the module Modbus communication parameters: address and Baud Rate. In the following table the Baud Rate and the address values are listed as a function of the DIP-switches positions: DIP-Switches Status POSITION BAUD POSITION ADDRES POSITION 1 2 3 4 5 6 7 8 910 RATE 1 2 3 4 5 6 7 8 910 S 1 2 3 4 5 6 7 8 910 TERMI- NATOR x x x x x x x x 9600 x x x x # 1 x x x x x x x x x Disabilitato x x x x x x x x 19200 x x x x # 2 x x x x x x x x x Enabled x x x x x x x x 38400 x x...... x x #... x x x x x x x x 57600 x x x x # 63 x x x x From EEPRO x x x x From EEPROM Note: when switches from 3 to 8 are in OFF, comunication settings are taken from the EEprom. Register Name Description 40002 INPUT, OVERFLOW Digital Inputs MODBUS registers: Holding registers The status of the inputs is available in the bits: input 1: 40002.0 input 2: 40002.1 input 3: 40002.2 input 4: 40002.3 input 5: 40002.4 The bits from 40002.8 to 40002.12 indicate overflow of the respective totalizers. NOTE: The overflow bits MUST be reset from master. 40003 TOTAL 1 16 bits totalizer of input 1. The overflow is available at bit 40002.8. 40004 TOTAL 2 16 bits totalizer of input 2. The overflow is available at bit 40002.9 40005 TOTAL 3 16 bits totalizer of input 3. The overflow is available at bit 40002.10 40006 TOTAL 4 16 bits totalizer of input 4. The overflow is available at bit 40002.11 40007 TOTAL 5 16 bits totalizer of input 5. The overflow is available at bit 40002.12 MI002056-E ENGLISH 6/8

Register Name Description 40014 INPUT, OVERFLOW The status of the inputs is available in the bits: input 1: 40002.0 input 2: 40002.1 input 3: 40002.2 input 4: 40002.3 input 5: 40002.4 The bits from 40002.8 to 40002.12 indicate overflow of the respective totalizers. NOTE: The overflow bits MUST be reset from master. 40015 TOTAL 1 16 bits totalizer of input 1. The overflow is available at bit 40002.8. 40016 TOTAL 2 16 bits totalizer of input 2. The overflow is available at bit 40002.9 40017 TOTAL 3 16 bits totalizer of input 3. The overflow is available at bit 40002.10 40018 TOTAL 4 16 bits totalizer of input 4. The overflow is available at bit 40002.11 40019 TOTAL 5 Lower part 40020 TOTAL 5 Upper part Less significant part of the 32 bit (Unsigned) totalizer for the input 5. Most significant part of the 32 bit (Unsigned) totalizer for the input 5. MODBUS Registers: Input status Register Name Description 10001 INPUT 1 Active status input 1. See bit 40009.0 10002 INPUT 2 Active status input 2. See bit 40009.1 10003 INPUT 3 Active status input 3. See bit 40009.2 10004 INPUT 4 Active status input 4. See bit 40009.3 10005 INPUT 5 Active status input 5. See bit 40009.4 MODBUS Registers: Coil registers Register Name Description 00017 OFTOTAL 1 Input 1 overflow totalizer. 00018 OFTOTAL 2 Input 2 overflow totalizer. 00019 OFTOTAL 3 Input 3 overflow totalizer. 00020 OFTOTAL 4 Input 4 overflow totalizer. 00021 OFTOTAL 5 Input 5 overflow totalizer. Frontal Panel LEDs Signallings LED STATUS Meaning of LEDs PWR Green On Power supply presence. FAIL Yellow Blinking Error setting. FAIL Yellow On Fault or Failure. RX Red Blinking Receiving data from RS485. RX Red On Verifying the connection. TX Red Blinking Transmitting data to RS485. TX Red On Verifying the connection. MI002056-E ENGLISH 7/8

Default Condition Module factory settings parameters All DIP-Switches position: OFF = setting from EEPROM MODBUS Protocol Communication parameters: 38400 8,N,1 Addr. 1 Reversed input status: DISABLED Digital filter: 3 ms Totalizer: UP counter 10 KHz on Channel 5: DISABLED MODBUS latency time: 5 ms Module Layout MODULE DIMENSIONS FRONTAL PANEL FAIL x PWR x 112 mm RX x TX x 1 x 2 x 3 x 4 x 5 x 17,5 mm Z-D-IN 100,0 mm Variation of standard parameters are possible by using configuration software (see: www.seneca.it) For more information about a list of all register and their function refer to the USER manual. Decommisioning and Disposal Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European countries with separate collections programs). This symbol, found on your producr or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical & electronic equipment. By ensuring this product is didposed of correctly, you will help prevent potential negative consequences to the environment and human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of materials will help to conserve natural resources. For more detailed information about the recycling of the product, please contact your local city office, waste disposal service of the retail store where you purchased this product. MI002056-E ENGLISH 8/8