LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Similar documents
VariTime TM Digital Sync Generator, PT 5210

specification MSE series MSE and MSE+ colorimeter

DISPLAY COLOR ANALYZER MODEL 7123 MODEL Display Color Analyzer. Key Features:

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Calibration of Colour Analysers

ICAC User Manual. ICAC - ( Intelligent Connection for Alignment & Calibration ) Setup Calibration Measurement USO RESTRITO. Version 14.2.

specification hyperion colorimeter

specification hyperion colorimeter

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

FLAT DISPLAY TECHNOLOGY

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

IMPAC Infrared Thermometers

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

Advantech Proudly Presents Professional Monitor Series

BVM-D Series. Multiformat Monitors. Unquestioned performance. Uncompromising quality. this is not a rehearsal.

Process Transmitter RMA 422

MODEL NUMBER BVM-D32E1WU

Embedded Analog Audio Output. Embedded Audio Indicator. Remote (Infrared rays) Auto Set-up Marker. 16:9mask

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

1. General Specification

Signal Stability Analyser

V R171P-HDA R171P-HDA

Broadcast and Professional Monitors

specification display applications cronus spectrometer & colorimeter

Selected Problems of Display and Projection Color Measurement

Video VBOX Waterproof

Broadcast and Professional Monitors

CM-392-Video to HDMI Scaler Box ID#481

Showcasing Brilliant Photos with Superb High- Definition Clarity

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: FC-46xl HDMI Audio De-Embedder. P/N: Rev 6

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

3CCD Color Video Camera BRC-300 BRC-300P. USA Security Systems

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

PRODUCT NO.: PT-L735 PRODUCT NAME: Ultra Portable LCD Projector

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

What is a Visual Presenter? Flexible operation, ready in seconds. Perfect images. Progressive Scan vs. PAL/ NTSC Video

POWER TO YOUR NEXT STEP

CP-255ID CV, SV, VGA and DVI to DVI Scaler / Converter OPERATION MANUAL

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

MX194. Your advantages. 1MP Medical-Display

MODEL NUMBER PVM-20L5

Video VBOX Lite RLVBVD10LT2. Powerful VBOX data logging and video technology in a user-friendly, affordable product. What can Video VBOX Lite do?

LCD MODULE SPECIFICATION

UNIGAS Hand-held combustion gas analyzer with 3 sensors

Setup Guide. SpectraCal C6 HDR2000 Colorimeter. Rev. 1.2

Measurement of Microdisplays at NPL

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

HDMI Extender via 4 Single-mode fibers 4 x LC Connector Extends HDMI + RS232 full-duplex up to 1500 meters

Using Low-Cost Plasma Displays As Reference Monitors. Peter Putman, CTS, ISF President, ROAM Consulting LLC Editor/Publisher, HDTVexpert.

System Interface Unit SIU-100/100T

Technical Developments for Widescreen LCDs, and Products Employed These Technologies

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

The measurements are stored in non-volatile memory, which retains data even when the power down.

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses

SMART Board interactive whiteboard system Model 685i5

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

CORIO master C3-540 Series

Multi-Monitor Dynamics, Picture-Perfect Communication

PRODUCT NO.: PT-L735NT PRODUCT NAME: Ultra Portable Wireless LCD Projector

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

NEC MultiSync PA322UHD-2. Wide Gamut 4K UHD resolution, LED-backlit color accurate desktop display

RVP-511DMS RVP-411DMS

ST-4000 SIGNAL LEVEL METER

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

USER MANUAL. Table of Contents. 1.0 Introduction Specifications Package Contents Panel Descriptions.. 4

Colour Matching Technology

MX215. Your advantages. 2MP Medical-Display

Microwave Counter, Power Meter and DVM in One Portable Package

SIMATRIX NEO V2 Modular Video Matrix

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

V9A01 Solution Specification V0.1

NEC MultiSync PA243W. Wide Gamut color critical accurate desktop display

28 To 48 Rugged UltraWide Industrial Displays

LED TEST. ATX Hardware GmbH West and Feasa Enterprises Limited a long-standing partnership. SPECIALIST FIXTURE SOLUTIONS

ST-4000D SIGNAL LEVEL METER

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

BRAVIA LCD TV - MFM-HT205

LCD Display Wall Narrow Bezel Series

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Click to Print This Page. 9,500 ANSI / 10,500 ISO Lumens Contrast Ratio: 10,000:1 (Dynamic Black) 1,000:1 native Part Number:

BARCOVISION 708 SERIES

NEC MultiSync PA Series Wide Gamut LED-backlit color accurate desktop displays

PMCL300 Series TFT LCD Monitor 17-INCH, 19-INCH, OR 19-INCH WIDE, WITH MULTIMODE FUNCTIONALITY

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

Advanced Test Equipment Rentals ATEC (2832)

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

D-ILA PROJECTOR DLA-G15 DLA-S15

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

NVISION Compact Space and cost efficient utility routers

NEC MultiSync P403. NEC LCD 40" Large Format Display DELIVERING GENUINE BENEFITS OUTSTANDING PERFORMANCE. Order Code: P403

USER MANUAL. Kramer Electronics, Ltd. Models:

SMART Board interactive whiteboard system Model 685i5

Transcription:

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94 Colour balance alignment of LCD/EL displays Optical system for spot measurements High speed operation for automatic manufacturing systems Communicates with standard RS-232 interface True CIE Standard Observer characteristics Numerical outputs of CIE XYZ values Calibration to any white reference Operates independent of field rate, also computer graphics and HDTV Calibration traceable to international standards The PM 5639 LCD Colour Analyser family has been developed for the purpose to assure the same high standard of picture quality as we have achieved with CRT colour nalysers. As flat panel display technology increases its presence on the market, from computers to the monitors on the broadcast industry, the same need for controlling colour fidelity, as for the CRT s, is necessary. The LCD Colour Sensor, PM 5639/94 can be delivered as 2 systems: one for handheld operation and one for industrial use. LCD Colour Analyser, PM 5639/06; handheld use This system consists of the LCD colour sensor and a handheld display unit. A rechargeable battery in the display unit enables easy operation anywhere. The units are delivered in a suitcase. LCD Colour Analyser, PM 5639/26, Industrial and PC-based The industrial version consists of a LCD colour sensor and a software package, which runs under DOS, or in a DOS-window under Windows 95 or 98. A ruggedized power supply and necessary cables complete the package. The LCD colour sensor is designed for measurement at a certain distance from the display. Although calibrated at fixed distance it can be used at distances from a few millimetres up to some 20cm. Only the luminance value is slightly affected of the distance. A correction table to be applied. Test signals When the sensor is used together with the handheld display unit, full benefits of the PM 5639/82 and PM 5639/83 Colour Alignment Generators can be achieved. The display unit works in this set-up as a control unit for the generator. The required test signals can then be recalled automatically

Measurement and Display modes The Absolute Measuring Modes: xyy and u v Y Two absolute measuring modes both defined by CIE the International Commission on Illumination are realised in the PM 5639. The xy system is the original CIE 1931 colour measuring system. The u v CIE 1976 is later made as a change to the original xy system. The latter system is more colour uniform than the original, meaning that the system is a better description of the human colour perception, related to the perception of colour differences. It is possible by numeric calculation to convert from the one system to the other. The colour coordinates is showed in either an xy or an u v diagram, and at the same time the numerical chromaticity values are shown together with the luminance value (Y) and the correlated colour temperature. In the RGB bargraph display the difference between the reference values and the measured values are displayed. In all modes the colour error de CIELUV is calculated as the difference between the reference and the actual colour according to the CIE 1976 L*u*v* (CIELUV) colour space definition. 1 CIE- LUV is very close to the smallest colour difference, detectable by the human eye. The display, either on the Display Unit or on the PC, will show the measurement graphically in a coordinate system, where the pre-programmed colour reference is shown as a small box and the measured colour as a dot. The monitor is adjusted correctly when the dot falls within the box. Using the zoom function this adjustment can be done very accurately. The luminance Y is shown in the unit selected by the user i.e. candela/m 2, NIT or foot-lambert. These absolute measurements are made possible by using the concept, which relies on optical interference (dichroic) filters. The concept makes it possible to make CIE filters, which are completely equal the colour response of the Standard Observer as defined by CIE. This together with a traceable calibration assures a correct white reference on any monitor independent of the actual phosphor. RGB Measuring Mode In the RGB measuring mode the red, green and blue values are shown as three analogue bars. These bars are displayed relative to the white reference. There are four possibilities. Two of the primary colours are related to the third All three primary colours are related to a pre-programmed white reference All three primary colours are related to one of the measurements stored in the memory of the colour analyser All three primary colours are related to an absolute reference level selected by the user In all cases the absolute luminance value will be displayed in Candela/m 2, NIT or foot- Lambert as selected by the user. In the RGB display mode, the adjustment is carried out by bringing the amplitude of the three bars into the centre of the display. It is also possible to use a zoom function to increase the resolution and make a more accurate adjustment. For the RGB mode to work correctly, the instrument has to know the actual phosphor. This is accomplished in a couple of minutes by use of the monitor controls and the Colour Analyser "learn" mode. The "learn" mode procedure removes the interaction (crosstalk) between phosphors when viewed by the trireceptors. The phosphor can be stored and named in the colour analyser for later use. The following parameters have been factory programmed. The user can program more himself: Two different standard phosphors have been pre-programmed: EBU and SMPTE "C" A maximum of 28 different phosphors can be stored with the "learn" facility The three most used references: D6500, 3200 K and 9300 K are preset from the factory. Different white references can be programmed into Display unit or PC either as a measurement of the CRT, or the reference can be entered directly as x and y values Three different measuring units. The user can select between Canela/m 2, NIT or foot-lambert PM5639/06, PM5639/26 & PM5639/94 - Datasheet

Sensor Head PM 5639/94 Measurement Range Luminance 0.5 to 1000 Cd/m 2 (0.15 to 300 FtL) x and y values 0.000 to 0.800 Correlated Colour Temperature: 1900 K CCT to 12.000 K CCT Angle of aperture: ±10 Measuring distance: calibrated at 130mm. Luminance within ±2 Cd/m 2 in range 5 to 200mm Accuracy The following specifications apply to a measurement with an illuminant D6500 standard monitor 1 ) at a luminance level of 80 Cd/m 2 (23.3 FtL) and at a distance of 130mm and at an ambient temperature of 15 C to 30 C (59 F to 86 F) Chromaticity (measured on white): Accuracy: ±0.002 Repeatability: ±0.002 Luminance Accuracy at reference distance: ±2% ±1 digit Repeatability: ±0.3% ±1 digit XYZ/RGB bars: ±1% Repeatability: ±1% Luminance(Y): ±2% ±1 digit Measuring rate: When used with the display software: 3 and 10 measurements/second. When used wth the communication modules: up to 15 measurements/second programmable Correlated colour temperature: ±50 K CCT Scan Rates The PM 5639/94 automatically adjusts itself to the field-scanning rate including HDTV and graphical systems Accessories: The PM 5639/94 is delivered without any accessories but the Operating Manual. 1) Calibration of the standard monitor is traceable to NIST, USA with respect to chromaticity, and to BIPM, France with respect to luminance LCD Colour Analyser PM 5639/06 with display unit Handheld LCD Colour Analyser This stand-alone system consists of the LCD Colour Sensor, Display Unit plus necessary accessories. For the basic measurement specification, refer to chapter above. Display Type:64 by128 dot matrix LCD display with switchable back-lighting (auto switch-off function is provided) Display Modes CIE xyy mode: x and y coordinates are plotted in a CIE1931 xy diagram and shown numerically together with the correlated colour temperature and the colour error in CIELUV. CIE u'v'y mode: u' and v coordinates are plotted in a CIE1976 u 'v diagram and shown numerically together with the colour error in CIELUV. The x'y' and u'v' modes give readout of the difference between the measured and the reference chromaticity coordinates. RGB mode: Red, Green and Blue values are shown as bar graphs. The colour balance is displayed relative to a selected reference: one of the bars, the luminance, an absolute level or relative to a previous measurement (memory location) Memory References: 10 memories for colour white references Range for x and y: 0.2 to 0.6 CRT-phosphors: 30 memories for different phosphors Set-ups: 10 memories for different measuring set-ups. Factory Programming White references: D6500 (x=0.313, y=0.329) 3200K (x=0.423, y=0.399) 9300K (x=0.285, y=0.293) Other white references may be stored by using the Learn white reference function. The numbers, as measurements, can also be input directly into the file. Power Supply Battery operated. Interchangeable NiCd rechargeable 7.2 V battery pack. Consumption: 85 ma (illumination off) 115 ma (illumination on) Operating time: >5 h with fully charged batteries Battery charging time: <14 h with instrument off Mains voltage: 85-140 V AC or 187-250 V AC Consumption of charger: < 6 VA Frequency: 48 Hz to 65 Hz Accessories The PM 5639/06 package includes: PM 5639/94 LCD Colour Sensor PM 5639/80 Display Unit Interconnection Cable Rechargeable Battery Pack 110V AC or 230V AC Battery Charger Operating Manual Carrying Case PM5639/06, PM5639/26 & PM5639/94 - Datasheet

LCD colour Analyser PM 5639/26 for PC-solutions LCD Colour analyser for Industrial use and PC-based solutions. This stand-alone system consists of the LCD Colour Sensor, Power Supply, PC- Software plus necessary accessories. For the basic measurement specification, refer to chapter above. The Display Software Module The display software shows the measured results directly as CIE values, or as differences between the preprogrammed white reference and the actual measured colour on a PC picture monitor. The results may also be shown as relative RGB values. The display software module uses the 4800 baud mode only. The xyy, u v and uv modes. The chromaticity coordinates are plotted in the relevant CIE chromaticity diagram: xy uses CIE 1931 definition u v uses CIE 1976 definition uv uses CIE 1960 definition The luminance value Y and the colour difference between the reference and the measurement are displayed as numerical values below the display. The äxäy, äu äv and äuäv modes. The difference modes display a coordinate system with origin at the selected white reference and the measured colour deviation from this reference. The numerical values are shown below the coordinate system. The bargraph modes The XYZ and RGB modes show the measured values as bar graphs. The graphs may be normalised to a selected phosphor, a specific luminance level or relative to the measured luminance. The Communication Software The communication with the PM 5639/26 sensor is with standard RS 232 interface. The communication software modules explain how to implement application specific programs. Examples are written in Basic, C and Pascal. The modules in Basic and Pascal can be used in the 4800 baud mode only, whereas the C modules are for both 4800 and 9600 baud modes. Memory References: The white references are stored in the computer. Legal values for x and y are between 0.200 and 0.600 CRT/Phosphors: 30 different phosphors may be stored in the sensor, additional phosphors may be stored in the computer. Phosphors may be stored via the Learn phosphor function. The phosphors are only applicable when using the RGB bar graph display Set-ups: an unlimited number of measuring set-ups may be stored in the computer. A measuring set-up includes the display mode, CRT/Phosphor (RGB displays only), white reference and measuring units Measurements: an unlimited number of measurements may be stored and recalled for later investigation and statistical analysis. Stored measurements may also be used as white references Factory Programming White references: D6500 (x=0.313, y=0.329) 3200K (x=0.423, y=0.399) 9300K (x=0.285, y=0.293) Other white references may be stored by using the Learn white reference function. The numbers, as measurements, can also be input directly into the file. Hardware Requirements PC with RS 232 port Floppy disk drive 3½ Operating system: MS-DOS, Windows 95 and 98. The software is DOS-based with a Windows like appearance. It runs in most Windows 95 or 98 environments in a DOS-box Power supply box: A rugged unit interfacing between sensor and PC Size: 185 x 95 x 65 mm (7.3 x 3.8 x 2.6 ) PM 5639/06, PM 5639/26 & PM 5639/94 Data Sheet

General Specification Environmental condition Operating temperature: 10 C to 40 C (50 F to 104 F) (noncondensing) Storage temperature: -10 C to 70 C (-14 F to 158 F) (non-condensing) Vibration: IEC 68-2-6 F; 5-50-200 Hz 0.7 mm PP 50 m/s 2 ; 1 octave/min; 3x30 min Bump: IEC 68-2-29 part 2; 350 m/s 1000 bumps in 3 directions Repetitive bump: 120 m/s 2 Mechanical data Colour Sensor Diameter of sensor: 40 mm (1.6 ) Length: 300 mm (11.8 ) Weight: 270 g (0.6 lb) Accessories Accessories: PM 5639/06 The PM 5639/06 LCD Colour Analyser package includes: PM 5639/94 LCD Colour Sensor PM 5639/80 Display Unit with Rechargeable Battery Pack Interconnection Cable between sensor and display unit. 110V AC or 230V AC Battery Charger Operating Manual Carrying Case Accessories: PM 5639/26 The PM 5639/26 LCD Colour Analyser package includes: PM 5639/94 LCD Colour Sensor Software package with display module and communication modules with source code in Pascal, C and Basic Power supply box for one sensor Interface cable between controller and power supply box (9 pole sub-d connectors) Interface cable between sensor and power supply (9 pole sub-d connectors) Mains cable Operating manual, including Source Code documentation Accessories: PM 5639/94 The PM 5639/94 is delivered with: Operating manual. PM 5639/82 and /83 The optional PM 5639/82 Colour Alignment Generator Component and the PM 5639/83 Colour Alignment Generator Composite are designed to operate automatically together with the Display Unit of the PM 5639/00 and Optional Accessories PM5639/06. The generators may be connected to the display unit, which thus operates as a remote control unit. The required test signals for the different calibrations of the monitor can then be recalled automatically. This is especially time saving when performing the low level and high level white balance adjustments. PM 5639/06, PM 5639/26 & PM 5639/94 Data Sheet

PM 5639 Related Products PM 5639/00 9449 056 39001 CRT colour analyser with hand-held display unit PM 5639/01 9449 056 39011 CRT colour analyser with PC interface & software PM 5639/02 9449 056 39021 CRT Colour Alignment System for Barco Monitors PM 5639/03 9449 056 39031 CRT Colour Alignment System for Sony Monitors Projector PM 5639/06 9449 056 39061 LCD Colour Analyser with handheld display unit PM 5639/20 9449 056 39201 Industrial CRT Colour Analyser, single sensor version PM 5639/21 9449 056 39211 Industrial CRT Colour Analyser, double sensor version PM 5639/25 9449 056 39251 Miniature CRT Colour Analyser PM 5639/26 9449 056 39261 LCD Colour Analyser for Industrial and PC-applications PM 5639G/82 9449 056 39823 Colour Alignment Generator, component 625 lines PM 5639M/82 9449 056 39828 Colour Alignment Generator, component 525 lines PM 5639G/83 9449 056 39833 Colour Alignment Generator, composite 625 lines, PAL PM 5639M/83 9449 056 39838 Colour Alignment Generator, composite 525 lines, NTSC Options PM 5639/61 9449 056 39611 Expansion kit - to upgrade PM 5639/20 to PM 5639/21 PM 5639/62 9449 056 39621 Expansion kit -.to upgrade PM 5639/00 to PM 5639/01 PM 5639/63 9449 056 39631 CRT Auto Colour Alignment Option for Barco Monitors PM 5639/64 9449 056 39641 CRT Auto Colour Alignment Option for Sony Monitors PM 5639/80 9449 056 39801 Display unit PM 5639/90 9449 056 39901 CRT Colour sensor PM 5639/92 9449 056 39921 Industrial CRT sensor PM 5639/93 9449 056 39931 Miniature CRT colour sensor PM 5639/94 9449 056 39941 LCD Colour Sensor PM 8549/06 9449 085 49061 6 m extension cable for PM 5639 PM 8549/10 9449 085 49101 10 m extension cable for PM 5639 PM 8550 9449 085 50001 Calibrating software for PM 5639/90 and PM 5639/92-93 PM 8563 9449 085 63001 Interface cable for PM5639/80 to connect to PM8639/93 and PM5639/94 PM 8664 9449 085 64001 Auto set-up cable for auto alignment of Barco HDM 5049 monitor series Ordering Information PM 5639/06 9449 056 39061 LCD Colour Analyser with handheld display unit PM 5639/26 9449 056 39261 LCD Colour Analyser for Industrial and PC-use PM 5639/94 9449 056 39941 LCD Colour Sensor FOR FURTHER INFORMATION Contact the PTV sales office in your area, or contact us directly: International: DK-AUDIO A/S Marielundvej 37D DK-2730 Herlev Denmark Tel: +45 44 85 02 55 Fax: +45 44 85 02 50 e-mail: info@dk-audio.com UK: DK-AUDIO (UK) Ltd Crableck Lane Sarisbury Green Southhampton SO31 7ZN England Tel: +44 870 2414 118 Fax: +44 870 2414 119 e-mail: apa@dk-audio.com Germany: DK-AUDIO Germany Ziegeleiweg 16 D-31832 Springe Germany Tel: +49 (0) 5041 80 29 80 Fax: +49 (0) 5041 80 29 99 e-mail: info.de@dk-audio.com USA: DK-AUDIO America Inc. 4417 East Villa Rita Drive, Phoenix, AZ 85032, USA Tel: +1 602 765 0532 Fax: +1 602 765 1473 e-mail: jdt@dk-audio.com Data subject to alteration without notice. Printed in Denmark 2003-09-03