Contents RF-ID Reader MANUAL... 5 1. REM125 Series... 6 1.1. REM125 Series Specification... 6 1.1.1. Product specification... 6 1.1.2. Environment specification... 6 REM125 Series Parts... 7 1.1.3. REM125 Series Front... 7 1.1.4. REM125 Series upper section... 8 1.1.5. REM125-5 lower section... 8 1.2. REM125 Series installation... 9 1.2.1. Caution during REM125 Series installation.... 9 1.3. Power connection... 9 1.3.1. When the power is supplied normally... 9 1.3.2. When the power is not supplied normally,... 10 1.3.3. Check the followings... 10 1.4. ANTENNA Connection... 10 1.5. Communication Line Connection... 10 1.5.1. RS-232 Serial Cable Connection Road... 10 1.5.2. RS-422 Serial Cable Connection... 11 1.5.3. RS-485 Serial Cable Connection... 12 1.6. Menu... 13 1.6.1. REM125 Series Menu Tree... 13 1.6.2. REM125 Series Normal Operation... 14 1.6.3. REM125 Series Configuration... 14 1.6.4. REM125 Series Test (Trial mode)... 18 1.7. Host Communication... 18 1.8. Recognition Test... 18 1.9. Problems and solutions... 20 1.9.1. Power-related problems... 20 1.9.2. Problems on the connection between the networks... 20 1.9.3. Operation Related problems... 20
RF-ID ANTENNA MANUAL... 22 2. EA125C... 23 2.1. EA125C Specifications... 23 2.1.1. Product Specifications... 23 2.1.2. Environment Specifications... 23 2.2. EA125C Parts... 24 2.2.1. EA125C Front Section... 24 2.2.2. EA125C lower parts... 25 2.3. EA125C Installation... 25 2.3.1. Caution during E A125C Series installation... 25 2.4. EA125C Communication Line Connection... 26 2.4.1. Caution during cable connection.... 26 2.5. EA125C operation... 27 2.6. EA125C Problems and solutions... 27 3. EA125S... 28 3.1. EA125S Specifications... 28 3.1.1. Product Specifications... 28 3.1.2. Environment Specifications... 28 3.2. EA125S Parts... 29 3.2.1. EA125S Front Section... 29 3.2.2. EA125S lower part... 29 3.3. EA125S Installation... 30 3.3.1. Caution during EA125S installation... 30 3.4. EA125S communication Cable Connection... 31 3.4.1. Caution during cable connection... 31 3.5. EA125S operation... 32 3.6. EA125S Problems and solutions... 32 Supplement... 34 Supplement 1: Communication with the Host... 35... 35 4.1. RF mode... 35 1.1.1. Verbose mode... 35 1.1.2. Continuous mode... 35 4.2. Event report mode... 35 1.2.1 First talk mode(ft)... 35 1.2.2 Listen & talk mode(lt)... 35
5.... 35 Command Frame(Host to Reader... 36 5.2. Response Frame(Reader to Host)... 36 6.... 37 4. Frame Communication... 41 (1)READ Command Format (08h/2nh command)... 41 (2) WRITE Command Format (10h/18h/3nh command)... 41 Supplement 2: Device Check list... 42
RF-ID Reader MANUAL
1. REM125 Series 1.1. REM125 Series Specification 1.1.1. Product specification 1.1.2. Environment specification Item Specification Range of operation temperature Range of operation humidity No dew forms allowed Range of operation steam pressure steam pressure Range of storage temperature Range of storage humidity No dew forms allowed
REM125 Series Parts 1.1.3. REM125 Series Front LCD KEY 1.1.3.1. POWER and LED Lamp 1.1.3.2. LCD Display 1.1.3.3. KEY Parts
1.1.4. REM125 Series upper section 1.1.5. REM125-5 lower section 1.1.5.1. ANTENNA Connector 1.1.5.2. D-sub 9 Connector 1.1.5.3. DC power connection connector 1.1.5.4. Ground connection
1.2. REM125 Series installation can be installed on any place one can work with drills using M3.5 dish bolt on marked place( ) and in case of difficulty in drilling on the side of attachment, you can install it by using special bracket 1.2.1. Caution during REM125 Series installation. In case of difficulty in drilling on the face of attachment during the installation, install it on the designated area using the special bracket 1.3. Power connection 1.3.1. When the power is supplied normally
1.3.2. When the power is not supplied normally, 1.3.3. Check the followings. Confirm on polarity of power. 1.4. ANTENNA Connection 1.5. Communication Line Connection 1.5.1. RS-232 Serial Cable Connection Road The wiring diagram of serial cable is as follows
PC REM1356-5 Signal Pin No. Signal Pin No. CD 1 N.C 1 RD(RXD) 2 RD(RXD) 2 SD(TXD) 3 SD(TXD) 3 DTR(ER) 4 N.C 4 SG 5 SG 5 DSR(DR) 6 N.C 6 RS(RTS) 7 N.C 7 CS(CTS) 8 N.C 8 RI(CI) 9 N.C 9 1.5.2. RS-422 Serial Cable Connection
Ω 1.5.3. RS-485 Serial Cable Connection Ω
1.6. Menu 1.6.1. REM125 Series Menu Tree REM125-5 Ceyon Technology >>Run Apply POWER REM125 Series Func Func >>Configuration Set >>Configuration Reader Address Inc or Dec Set Func Reader Address >> Addr. : 01 Variation : Inc or Dec Confirm : Set >>Configuration RF Channel Inc or Dec Set Func RF Channel Variation : Inc or Dec >> RF Rfch1 Channel : On Confirm : Set >> Rfch2 RF Channel : On >> RF Rfch3 Channel : On >> RF Rfch4 Channel : On >> Rfch5 : On >>Configuration Serial Interface Inc or Dec Set Func Serial Interface >> Serial RS-232 Interface >> RS-485 RS-422 >> RS-422 Variation : Inc or Dec Confirm : Set >>Configuration Baudrate Inc or Dec Set Func Serial Interface >> Serial 9600bps Interface >> 19200bps >>Configuration Buzzer ON/OFF Inc or Dec Set Func Buzzer ON/OFF >> On On/Off toggle : Inc or Dec Confirm : Set Variation : Inc or Dec Confirm : Set >>Configuration RF Scan Weight Inc or Dec Set Func RF Scan Weight >> 03 Variation : Inc or Dec Confirm : Set Func >>Configuration Make Default Set Make Default >> Press <SET> Func Test Func Set Channel [1] Channel [2] Channel [3] Default : Set Channel [4] Channel [5] Func Variation : Inc or Dec Current Channel Test : Set
1.6.2. REM125 Series Normal Operation REM125-5 Ceyon Technology >>Run 1.6.3. REM125 Series Configuration 1.6.3.1. REM125 adress installation
1.6.3.2. RF Channel installation 1.6.3.3. Serial Interface installation
1.6.3.4. Baudrate installation 1.6.3.5. Buzzer ON/OFF installation
1.6.3.6. RF Scan Weight installation 1.6.3.7. Factory installation
1.6.4. REM125 Series Test (Trial mode) 1.7. Host Communication 1.8. Recognition Test
Antenna Connection Power On Communication line connection Are the active channels set? Tag Recognized Is the ID identified and the follow up action performed? Data output and transmission Completed
1.9. Problems and solutions 1.9.1. Power-related problems After connecting the power connector, LED isn t on When this problem occurs, check the followings. Check the equipment of the power supply. Remove the cable from power input port and after 10 seconds reconnect it and restart 1.9.2. Problems on the connection between the networks When the connection between the host and cannot be made When this problem occurs, checks the followings. Check again the connection status of all kinds of cables connecting the host and REM125. Also check if using the private cable or not. Check the operational status of the host and The connection between and cannot be made When this problem occurs, checks the followings. Check again the connection status of all kinds of cables connecting the and. Also check if using the private cable or not. Check the operational status of and 1.9.3. Operation Related problems
If the problem is not solved after above procedure, pull off the power cable after turning off the system and call SEYON Technology (+82-31-267-1163).
Ceyon RFID 125 Series APPROVED ANTENNA for RFID System (REM125-5). Product Name / model name Approved Antenna Model name REM125-5 EA125-C EA125-S About the antenna specification, please see the antenna manual. Caution Modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. FCC Compliance Information This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received. Including interference that may cause undesired operation. Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ tv technician for help.
RF-ID ANTENNA MANUAL
2. EA125C 2.1. EA125C Specifications 2.1.1. Product Specifications 2.1.2. Environment Specifications
2.2. EA125C Parts 2.2.1. EA125C Front Section 2.2.1.1. LED Part 2.2.1.2. Buzzer display part 2.2.1.3.
2.2.2. EA125C lower parts 2.2.2.1. Reader connection 2.3. EA125C Installation can be installed on any place one can work with drills using M3.5 dish bolt on marked place( ) and in case of difficulty in drilling on the side of attachment, you can install it by using special bracket 2.3.1. Caution during E A125C Series installation In case of difficulty in drilling on the face of attachment during the installation, install it on the designated area using the special bracket
2.4. EA125C Communication Line Connection 2.4.1. Caution during cable connection.
2.5. EA125C operation 2.6. EA125C Problems and solutions
3. EA125S 3.1. EA125S Specifications 3.1.1. Product Specifications 3.1.2. Environment Specifications
3.2. EA125S Parts 3.2.1. EA125S Front Section 3.2.1.1. LED Part 3.2.2. EA125S lower part 3.2.2.1. Reader connector
3.3. EA125S Installation can be installed on any place one can work with drills using M3.5 dish bolt on marked place( ) and in case of difficulty in drilling on the side of attachment, you can install it by using special bracket 3.3.1. Caution during EA125S installation In case of difficulty in drilling on the face of attachment during the installation, install it on the designated area using the special bracket
3.4. EA125S communication Cable Connection 3.4.1. Caution during cable connection
3.5. EA125S operation 3.6. EA125S Problems and solutions If the problem is not solved after above procedure, pull off the power cable after turning off the system and call SEYON Technology (+82-31-267-1163).
Supplement
Supplement 1: Communication with the Host 4.1. RF mode 1.1.1. Verbose mode 1.1.2. Continuous mode 4.2. Event report mode 1.2.1 First talk mode(ft) 1.2.2 Listen & talk mode(lt)
Command Frame(Host to Reader 5.2. Response Frame(Reader to Host)
A0H : WRITING FAIL, A8H : READING FAIL, 80H : CHECKSUM FAIL 88H : Overflow 40H : EEPROM WRITING FAIL 20H: RF Mode error 28H:Event Mode error 10H : Unknown command 18H : Time Out
(1)READ Command Format (08h/2nh command) (2) WRITE Command Format (10h/18h/3nh command)
Device Check list