Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

Similar documents
Cold Shrink Straight Joint

Instructions. Cable with Armor F CAUTION. October Rev A

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5416A

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

Cold Shrink Silicone Rubber Termination QT-II

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

Industrial Loadbreak Elbow

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

HSK Mine and Portable Cable Splice

3M Cold Shrink Foldback Splice Jacket Kit

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

LEGEND POWER SYSTEMS

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Cold Shrink Rubber Splicing Kit 5552

2016 Cable Splicing Courses

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

3 Cold Shrink Products

Aging test: integrated vs. non-integrated splices shield continuity systems.

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

3M Better Buried Closures

3 SLiC Aerial Closure with Rubber End Seal

PRODUCT CATALOGUE 2016

MOTOR LEAD TO DOWN HOLE CABLE SPLICE PROCEDURE

ENERGY /// TRICKS OF THE TRADE TRICKS OF THE TRADE

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

92-AK620-1/C 92-AK630-1/C 92-AK621-1/C 11kV 92-AS610-1/C 92-AS620-1/C STND. 93-AK621-1/C 93-AK630-1/C 22kV 93-AK631-1/C 93-AS620-1/C STND

Low Voltage Splices, 1000 V or less


3M Better Buried Compound Compression Closure System

Student Services & Classroom Addition

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

UNSIGNED HARDCOPY NOT CONTROLLED

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES

Crimp & Cleave Termination Instructions for SEL ST Connectors

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

POLICY & APPLICATION GUIDE FOR 11kV POLYMERIC CABLES

RAIL D-SUB BACKSHELLS

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

L1-CHE-SPE-299 TECHNIQUES & MATERIALS FOR THE JOINTING & REPAIR OF RAILWAY SIGNALLING MULTI CORE AND POWER SUPPLY CABLE

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors

OCT 15 Rev B

Coaxial Cable Feedline Choke Kit - 50 Ω

British Rail Approved Items for 3M EMD Products

3M Distribution Box (DDB)

FOSC 450 C6 and D6 Closures

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

Electrical Cable Ties

VITALink Taped Splice Straight Through Crimp

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2178-L/S Series Fiber Optic Splice Case with Gasket

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

K & B Flame Retardant Building Riser Closures

RESIDENTIAL SUBDIVISION BILL OF MATERIALS

PYROTENAX TERMINATION KITS COMMERCIAL WIRING. For Pyrotenax copper sheathed mineral insulated (MI) wiring cable

AMP+ HVA280-2phm High-Voltage Plug Connector with Shunted HVIL

UNDERGROUND CONSTRUCTION MANUAL MATERIAL DATA

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

D-COAX, Inc. D-COAX Male-Female 1501 Series Cables and Cable Pairs. High Frequency, Skew Matched, Phase Stable Cable Pair (40 GHz)

IP-LINX. Installation Guide

FISCHER MINIMAX TM SERIES

Instrumentation Cables

Solderless RF Connectors

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

LCC (Little Coaxial Connector) Installation Instructions)

Medium Box for Cable Termination

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

HARTING Ethernet cabling cables and connectors, 4 wire

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Aruba Outdoor AP Antenna Weatherproofing

One Core Dual Shield Mini RG59. Three Core Dual Shield Mini RG59. Five Core Dual Shield Mini RG59. Eight Core Dual Shield Mini RG59

Adapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication

Stainless Steel SMA Connectors Product Catalog

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Transcription:

Quick Term III 3M Cold Shrink 3 Core Indoor Termination Instruction Sheet All dimensions shown are mm unless otherwise stated Kit Contents 3 QT-III Termination Assembly 1 Cold Shrink Breakout Boot 3 Phase Re-jacketing Sleeves 1 CC-2 Cable Preparation Kit * Sealing Mastic Strips 1 Scotch Super 33+ 3 Copper Foil Tape 1 Constant Force Spring 1 Instruction Sheet * Quantity varies according to kit model number Kit Selection Chart NOTE: Final determining factors are cable jacket and insulation diameters. Kit Number BIL kv Jacket Diameter Range mm Cable Insulation Range mm 3.3 kv 6.6 kv Cable Size 11 kv 15 kv 22 kv 7620-T-95-3W-AU 95 33-49 8.4-12.7 16-35 16-25 - - - 7621-T-95-3W-AU 95 37-68 12.7-17.8 50-95 35-70 10-50 - - 7621-T-110-3W-AU 110 37-68 12.7-17.8 50-95 35-70 10-50 16-25 - 7622-T-110-3W-AU 110 49-79 17.8-23.4 120-185 95-150 70-150 35-95 - 7624-T-110-3W-AU 110 64-110 23.4-30.0 240-300 185-300 185-300 120-185 - 7625-T-110-3W-AU 110 66-119 30.0-38.6 400-500 400-500 400-500 240-300 - 7693-T-150-3W-AU 150 49-79 17.8-23.4 120-185 95-150 70-150 35-95 25-70 7694-T-150-3W-AU 150 64-110 23.4-30.0 240-300 185-300 185-300 120-185 95-185 7695-T-150-3W-AU 150 66-119 30.0-38.6 400-500 400-500 400-500 240-300 240-300 NOTE: For 33 kv three core indoor terminations, select from the 33 kv kits in the QT-III Cold Shrink 3 Core Outdoor Termination Instruction Sheet. 3M AUSTRALIA PTY LTD ALL STATEMENTS TECHNICAL INFORMATION AND RECOMMENDATIONS CONTAINED HEREIN ARE BASED ON TESTS WE BELIEVE ARE RELIABLE. HOWEVER SINCE THE CONDITIONS OF USE AND THE APPLICATIONS ARE BEYOND OUR CONTROL THE PURCHASER IS RESPONSIBLE FOR THE TERMINATIONS MADE IN CONNECTION WITH THE USE OF THE DATA OR SUGGESTIONS HEREIN. Drawn : SELVA Modified : Des. Eng : SELVA Checked : SELVA ELECTRICAL PRODUCTS 3 FOR RELEASE SELVA 09.07.13 2 SUPERSEDED SELVA 23.05.13 ISSUE DESCRIPTION PAGE 1 OF 8 BY 3M COLD SHRINK QT-III SILICONE RUBBER TERMINATION FOR INDOOR APPLICATION for three core polymeric insulated copper wire screened cables according to IEC 60502 up to 12.7/22 (24) kv AV011427430 DATE A4

Prepare cable using dimensions shown in the following table. Dimensions Kit Number A G M mm mm mm 7620-T-95-3W-AU 140 40 100 7621-T-95-3W-AU 110 40 125 7621-T-110-3W-AU 185 40 125 7622-T-110-3W-AU 185 40 125 7624-T-110-3W-AU 185 80 125 7625-T-110-3W-AU 185 80 125 7693-T-150-3W-AU 275 40 125 7694-T-150-3W-AU 275 80 125 7695-T-150-3W-AU 275 80 125 ELECTRICAL PRODUCTS A4 PAGE 2 OF 8 AV011427430

D Copper Wire Screen Length of Phase Semi-Conductive Screen 5 G 30 Bedding Armour Jacket 1st Mastic Strip G 1st Mastic Strip Fig. 1a Jacket Fig. 1 1.1 Remove cable jacket for length of phase + D mm D = Depth of lug barrel * Allow 5 mm allowance for crimp lugs 1.2 Clean cable jacket for a length of approximately 200 mm. 1.3 Apply one layer of mastic strip onto the cable jacket according to given dimension. Fig. 1a Armoured cable: Prepare the cable crotch as shown. ELECTRICAL PRODUCTS AV011427430 PAGE 3 OF 8 A4

D Copper Wire Length of Phase Semi-Conductive Screen Constant Force Spring Copper Wire Screen 2nd Mastic Strip Copper Wire Screen 2nd Mastic Strip Fig. 2a Jacket Fig. 2 2.1 Bend the copper wire screen back onto the cable jacket, leaving a wire for each phase. Fix them with vinyl tape. 2.2 Fix the copper wire onto each phase with vinyl tape. 2.3 Apply a second mastic strip covering the copper wires onto the first layer. 2.4 Cover the mastic tape with two layers of vinyl tape. Fig. 2a Armoured cable: Contact the bent back copper wires to the armour using the large constant force spring. Cover the constant force spring with two layers of vinyl tape ELECTRICAL PRODUCTS AV011427430 PAGE 4 OF 8 A4

D Finger Cores Finger A Neck Neck Core 50 Copper Foil Tape Copper Wire Finger Cores Boot Fingers Boot Neck Neck Core Breakout Boot Fig. 3a Fig. 3 3.1 Unwind a few turns at the finger cores as shown in Fig. 3a. Do not remove too far that the fingers begin to collapse. 3.2 Slide the breakout boot into position. 3.3 Remove the neck core and shrink the boot neck onto the cable jacket. 3.4 Remove the core from each of the fingers. 3.5 Trim the copper wires at dimension A + D. 3.6 Wrap a layer of the copper foil tape over the copper wire according to the dimension given. ELECTRICAL PRODUCTS AV011427430 PAGE 5 OF 8 A4

Termination End Trim Line D S *Dimension is 20mm for 7620-T-95-3W-AU kit only. 75 30* 5 20 Boot End S Re-jacketing Sleeve Right 25 Wrong Breakout Boot Fig. 4a Fig. 4 4.1 Determine required phase re-jacketing sleeve length S. 4.2 Trim re-jacketing sleeve to length (S). Cut tubing and inner braid together. Inner polyester braid should extend approx. 75 mm beyond re-jacketing tube end before cutting. 4.3 Slide re-jacketing sleeve and overlap the finger by 25 mm. 4.4 Wrap the end of the re-jacketing sleeve with one half-lapped layer of vinyl tape according to dimension given in Fig. 4. ELECTRICAL PRODUCTS AV011427430 PAGE 6 OF 8 A4

D Conductor Connector Insulation A 35* Semi-con Screen *Dimension is 20mm for 7620-T-95-3W-AU kit only. Copper Foil Tape M Fig. 5 5.1 Remove the outer semi-conductive screen according to the dimensions given. 5.2 Remove the primary insulation according to dimension D. * Allow 5 mm allowance for crimp lugs NOTE: Ensure termination body inner core diameter is greater than the lug. Fig. 6 6.1 For compression lugs, crimp the lugs as per normal practice. 6.2 For shear-bolt lugs, install the lugs as per the instructions provided with the lugs. 6.3 Abrade all sharp edges and burs from the lugs. 6.4 Clean the insulation and lug using the CC-2 cable cleaning kit provided. 6.5 Apply a layer of vinyl tape according to dimension M. ELECTRICAL PRODUCTS AV011427430 PAGE 7 OF 8 A4

QT-III Termination Body Fig. 7 7.1 Slide the QT-III termination body into position. Remove the collapsible zip core by unwinding it in counter clockwise direction. Start to shrink from the vinyl tape. 7.2 Remove the vinyl tape marker after application of the termination body. Fig. 8 8.1 Termination completed. ELECTRICAL PRODUCTS AV011427430 PAGE 8 OF 8 A4