DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Similar documents
DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331i / DMP 333i LMP 331 i

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Pressure transmitter For applications in hazardous areas Model IS-3

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

TFRN Industrial RTD temperature sensor. CombiTemp TM

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor BI1.5-EG08K-Y1

TFRN Industrial RTD temperature sensor. CombiTemp TM

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Inductive sensor With analog output BI15-M30-LI-EXI

PROPORTIONAL VALVES Sentronic plus

PMG. Vibration Energy Harvesters

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

RSCC. Load cells. Special features. Data sheet

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Pendant Light Fitting IEC Series 6470/2

TFRH Hygienic RTD temperature sensor. CombiTemp TM

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Photoelectrics Through-beam Type PA18C.T..., DC

Level Measurement silometer FMC 420, FMC 423

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Quality products from a single source

Selection matrix for electronic pressure switches

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Process transmitter RMA422

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Micro-Machined Silicon Transducers

Single Point Flow Monitor SW118 SW119

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Process Transmitter RMA 422

Mechanical flow switch for On/Off control

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Pressure transmitter COMPACT IO-Link,

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Capacitance Level Measurement Electronic insert FEC 12

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Linear flow control with actuator IFC

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Model JDF Field Indicator

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

3 Cleaning. 4 Technical data

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Quality products from a single source

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

IEPE Premium Accelerometer, Top Connector

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Eddy Current Probe System

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Gear Pump Units For single-line centralized lubrication systems

Operating instructions

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Linear encoders without bearings incremental System for linear motion feedback

IONIVAC Transmitter ITR 90

Capacitive sensor BCT5-S18-UP6X2T-H1151

Absolute Encoders Multiturn

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Flow Switch. Flow Switch

Speed sensor MiniCoder GEL 2471

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Datasheet - SRB-E-201ST

Capacitance Limit Detection nivotester FTC 420/421/422

Transcription:

DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity small thermal effect excellent long term stability Optional versions The pressure transmitter DMP 4 has been especially designed for the measurement of very low gauge pressure and for vacuum applications. Permissible media are gases, pressurized air and non-aggressive low viscos oils. The DMP 4 features excellent thermal behaviour and outstanding long term stability. A variety of output signals as well as mechanical and electrical connections make the DMP 4 covering a wide field of applications. IS-version: Ex ia = intrinsically safe for gases and dusts SIL application according to IEC 6508 / IEC 65 different electrical and mechanical connections specific versions Preferred areas of use are Plant and Machine Engineering Heating and Air Conditioning BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

DMP 4 Input pressure range Nominal pressure gauge [mbar] -000 0 0 6 5 40 60 00 60 50 400 600 000 Overpressure [bar] 0. 0. 0. 0.5 0.5 Burst pressure [bar] 5 0. 0. 0. 0.75 0.75.5 5 5 5 5 Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-protection -wire: 4... 0 ma / V S = 0... 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy : ± 0.5 % FSO nominal pressure 00 mbar: ± 0.50 % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0 A] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [mbar] -000... 0 00 400 > 400 Tolerance band [% FSO] ± 0.75 ±.5 ± ± 0.75 in compensated range [ C] -0 85 0 50 0 70-0 85 Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection Reverse polarity protection Electromagnetic compatibility Mechanical stability permanent no damage, but also no function emission and immunity according to EN 66 Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 500 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.4404 (6L) Housing stainless steel.4404 (6L) Seals (media wetted) FKM Sensor stainless steel.4404 (6L), silicon, epoxy or RTV, mineral glass Media wetted parts pressure port, seals, sensor Explosion protection (only for 4 0 ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX9-DMP 4 zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values Permissible temperatures for environment Connecting cables (by factory) U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0nF, L i 0 µh, the supply connections have an inner capacity of max. 7 nf opposite the housing in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone or higher: -0... 70 C cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Option SIL application according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 5 ma Weight approx. 40 g Installation position any CE-conformity EMC Directive: 004/08/EC ATEX Directive 94/4/EG pressure and level

DMP 4 Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) supply + p VS VS supply I supply I / U signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (only for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / metal (4-pin) Shield ground pin 5 4 field housing IN + IN - OUT+ cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request : m PVC cable without ventilation tube (permissible temperature: -5... 70 C) different cable types and lengths available, permissible temperature depends on kind of cable www.bdsensors.com

DMP 4 Mechanical connection (dimensions in mm) option G/" DIN 85 with ISO 4400 G/" EN 87 G/4" DIN 85 G/4" EN 87 metric threads and others on request G/" open port /" NPT /4" NPT This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. DMP4_E_7 pressure Tel: and +49 level (0) 9 5 / 98-0 www.bdsensors.com Fax: +49 (0) 9 5 / 98 - info@bdsensors.de

Ordering code DMP 4 DMP 4 - - - - - - - Pressure Input Output gauge 0 0 [mbar] 0 0 0 0 6 0 6 0 5 0 5 0 40 0 4 0 0 60 0 6 0 0 00 0 0 0 60 6 0 0 50 5 0 0 400 4 0 0 0 600 6 0 0 0 000 0 0-000 0 X 0 9 Accuracy for P N > 00 mbar 0.5 % for P N 00 mbar 0.5 % 5 Electrical connection Special version E 9 consult 0 0 0 0 T A 0 T R 0 M 0 : m PVC cable without ventilation tube (permissible temperature: -5 70 C), optionally cable with ventilation tube cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable metric threads and others on request 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal Compact field housing stainless steel.405 Mechanical connection G/" DIN 85 G/" EN 87 G/4" DIN 85 G/4" EN 87 G/" DIN 85 open pressure port /" NPT /4" NPT Seals FKM 8 5 0 0 0 0 0 0 0 4 0 0 H 0 0 N 0 0 N 4 0 9 consult 0 0 0 07.0.0 This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.