Role of Color in Telemedicine Applications. Elizabeth A. Krupinski, PhD

Similar documents
3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

White Paper. Uniform Luminance Technology. What s inside? What is non-uniformity and noise in LCDs? Why is it a problem? How is it solved?

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017

Coronis 5MP Mammo. The standard of care for digital mammography

This talk covers currently available display technology.

Guidelines for Assuring Softcopy Image Quality

Solution for Nonuniformities and Spatial Noise in Medical LCD Displays by Using Pixel-Based Correction

White Paper. Diagnostic Color Displays. What s inside?

MX215. Your advantages. 2MP Medical-Display

Monitor QA Management i model

Nio. Industry-standard diagnostic display systems

Mammo Tomosynthesis 5MP

MX194. Your advantages. 1MP Medical-Display

The Diagnosis of Small Solitary Pulmonary Nodule:

Hospital Wide. Healthcare Display Solutions DICOM Displays, Large Screen Displays and Projectors

What to consider when choosing a mammography display

Optimizing the Workflow of Radiologists

CLINICALLY PROVEN DESIGNS

MX215. Your advantages. 2MP Medical-Display

+ Human method is pattern recognition based upon multiple exposure to known samples.

Contrast-Detail Characteristic Evaluations of Several Display Devices

Nio. Industry-standard diagnostic display systems

Technical Developments for Widescreen LCDs, and Products Employed These Technologies

Guidance for Quality Assurance of PACS Diagnostic Display Devices

Selection and Quality Assurance of Monitors for Mammogram Diagnosis

Is image manipulation necessary to interpret digital mammographic images efficiently?

COMPUTER APPLICATIONS

Aging display s effect on interpretation of digital pathology slides

Coronis Fusion multi-modality displays. The ultimate in diagnostic flexibility

Advantech Medical Monitor Q1/2016 Roadmap

Medical Monitor Solutions

Global Trade Medical Supplies

Medical Monitor Solutions

Setup Guide. EIZO Monitors. Rev. 1.4

RX850. Your advantages. 8MP Medical-Display

Clarity and confidence. Raising the bar in diagnostic imaging with Barco radiology and mammography displays

NEC MultiSync PA243W. Wide Gamut color critical accurate desktop display

Intuitive Workflow by Barco. Designed for the way you work, naturally.

Colour Matching Technology

Requirement for graphic arts display

MDSC-2232 Full HD 32-inch surgical display

Hardware Calibration LCD Monitors. ColorEdge Series. Color as it s meant to be

NEC MultiSync PA322UHD-2. Wide Gamut 4K UHD resolution, LED-backlit color accurate desktop display

NEC MultiSync PA Series with SpectraView II

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

Medical Monitor Solutions

Audio and Video II. Video signal +Color systems Motion estimation Video compression standards +H.261 +MPEG-1, MPEG-2, MPEG-4, MPEG- 7, and MPEG-21

Medical Monitor Solutions

Using Low-Cost Plasma Displays As Reference Monitors. Peter Putman, CTS, ISF President, ROAM Consulting LLC Editor/Publisher, HDTVexpert.

Quality Assurance (QA) Guidelines for Medical Imaging Display Systems

FFDM Quality Control in Canada - a Vendor Neutral Approach

White Paper. In Plane Switching Pro technology for medical imaging. Geert Carrein Director Product Management. What s inside?

NEC MultiSync PA Series Wide Gamut LED-backlit color accurate desktop displays

Evaluation report. Eizo RadiForce G33-N 3MP greyscale flat panel liquid crystal display (LCD) CEP 07003

World First Slim Cassette Type Digital Mammo. Upgrade Solution

Detectability of breast cancer and reading time on screening mammography: Comparison between 5-MP and 8-MP LCD monitors.

systems that are found throughout the large acute hospital sector so it would not be unusual to find a range of commercialoff-the-shelf

Principles of LCD monitor colors

Advantech Medical Monitor Q4/2015 Roadmap

Coronis Uniti (MDMC-12133) 12MP diagnostic display system for PACS and breast imaging

Coronis Fusion 6MP DL. 6 MegaPixel wide-screen diagnostic color display system

Australian Dental Journal

RX350. Your advantages. 3MP Medical-Display

Interpretation of Digital Chest Radiographs: Comparison of Light Emitting Diode versus Cold Cathode Fluorescent Lamp Backlit Monitors

Medical Physics and Informatics Original Research

Full-Field Digital Mammography on LCD Versus CRT Monitors

Accurate Colour Reproduction in Prepress

Performance Evaluation of Industrial Computed Radiography Image Display System

This paper is part of the following report: UNCLASSIFIED

Medical Imaging Working Group

S1934H-BK. Your advantages. 19" Office-Monitor

IBM Research Report. Color and Luminance Management for High-Resolution Liquid-Crystal Displays

Understanding Multimedia - Basics

Is that the Right Red?

Performance characteristics and quality assurance considerations for displays used in interventional radiology and cardiac catheterization facilities

Barco Healthcare. Product catalog

ColorEdge Color Calibration LCD Monitors

Communication Theory and Engineering

CG3145. Your advantages. 31.1" Graphics-Monitor

LCD Display Wall Narrow Bezel Series

Comparision Guide. Product Comparison HP Z Displays. HP Z Displays

Influence of display quality on radiologists performance in the detection of lung nodules on radiographs

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

Comparision Guide. Comparison Guide HP Z Displays. HP Z Displays

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

Setup Guide. Creating 3D LUTs. CalMAN Overview. Rev. 1.1

MANAGING HDR CONTENT PRODUCTION AND DISPLAY DEVICE CAPABILITIES

LMT X1 - a 12.1" VHB

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow

DATA SHEET. 14 cm (5.5 Type), Pixels, Full color NTSC/PAL mode, Incorporated backlight with inverter

CARESTREAM DIRECTVIEW Elite CR System

DEM A VMH-PW-N 5 TFT

HITACHI. Instruction Manual VL-21A

Medical Monitor Solutions

Flat Panel Displays: LCD Technologies and Trends

Coronis. A new generation of premium diagnostic display systems

Simply Exceptional Color. LCD Monitors for Graphics

3528 1W 2 Series White (IP)

Transcription:

Role of Color in Telemedicine Applications Elizabeth A. Krupinski, PhD

Background Color displays common clinical practice Radiology growing acceptance & use Other ologies & telemed routinely used No validated color display calibration protocol for medical color image applications No universally accepted image quality program for color displays in medicine Significant lack data showing that poor/inappropriate calibration affects diagnostic performance &/or workflow

Telerad & Color Color routine CT, MRI, US but what about bone, chest, mammo? Diagnostic accuracy & visual search efficiency high luminance (400 cd/m 2 ) MG color equivalent to high luminance (400 cd/m 2 ) MG monochrome display? Yes = MG color displays can be used as allpurpose diagnostic displays Krupinski et al. (2011). High luminance monochrome vs color displays: impact on performance & search. Proc SPIE Med Imag 7966 79661R1-6

Images 50 DR chest images Half solitary pulmonary nodule half without Locations confirmed DR & CT images Nodules size = 9 26 mm Shape = round or round with spiculations Subtlety = subtle to moderately subtle

Displays Eizo MG 3-Mpixel monochrome Eizo MG 3-Mpixel color Portrait mode Calibrated to DICOM GSDF Pixel pitch: color = 0.21075 mm (323.7 x 431.6 mm Diagonal: 540 mm) monochrome = 0.2115 mm (324.8 x 433.1 mm Diagonal: 541 mm) Max luminance = 400 cd/m 2 Min luminance = 0.75 cd/m 2

Study Details 6 radiologists view images each display Counterbalanced min 3 wks between sessions Ambient room lights = 25 lux Viewing distance ~ 45 cm Window & level allowed Report nodule present or absent & rate confidence definite, probable, possible MRMC ROC used to analyze Total viewing time recorded

Eye-Position Study Separate session viewed sub-set 15 images Eye-position recorded using 4000SU Eye-Tracker with head tracker

Diagnostic Accuracy No significant difference color vs mono F = 0.0136, p = 0.9078 Reader Color Az Monochrome Az 1 0.9209 0.9031 2 0.8913 0.8964 3 0.9002 0.8294 4 0.9455 0.9097 5 0.8597 0.9097 6 0.8710 0.9187 Mean 0.8981 0.8945

Viewing Time (sec) Total Viewing Time No significant differences color vs mono F = 0.392, p = 0.5315 35 30 25 20 15 Monochrom Color 10 5 0 Normal Image Type Abnormal

Typical Search Patterns Red dots = fixation or location eye lands foveal vision Size circle = dwell time: larger = longer dwell Lines = order fixations generated during search

Decision Dwell Time (msec) Decision Dwells No significant differences color vs mono F = 0.133, p = 0.7154 1600 1400 1200 1000 800 600 400 TP FN FP TN 200 0 Monochrome Display Color

Summary At least for task detecting chest nodules diagnostic accuracy & visual search efficiency equivalent using 3-Mpixel MG color & monochrome LCD displays

Common TM Applications

Common Calibration Tools

Common Calibration Tools

Less Common Tools

Rarely Used Methods

What About the Users? Improved understanding human observers Reduce errors Develop better training tools Improve workflow Improve image presentation Develop better displays, calibrations, tools etc. Intelligent compression Tailored computer processing & decision tools Better navigation tools Streamlined retrieval, display & reporting tools

Early Studies Teledermatology SF = In-person? 308 dermatology cases from IP Digital photos 832 x 608, 24-bit 3 dermatologists (intra & inter) 83% diagnostic concordance 62% very definite or definite Image sharp 83% good/excellent Image color 93% good/excellent Krupinski et al. (1999). Diagnostic accuracy & image quality using digital camera for teledermatology. TMEH 5;257-263.

Recent Studies

Calibration, Characterization & Profiling Silverstein et al. Achieving High Color Reproduction Accuracy in LCDs for Color-Critical Applications. JSID 2012;20:53-62

Calibration, Characterization & Profiling

Methods MatLab module evaluates color reproduction accuracy using display characterization & ICC profile Sets test colors generated taking intersection uniform sampling CIE Lab color space axes with reference color space (srgb) Set 210 test colors created

Uncalibrated Calibrated

Does It Matter? Whole slide images DMetrix scanner Breast biopsy specimens 250 ROIs selected by expert pathologist ½ malignant & ½ benign Independently graded 2 nd pathologist excellent or good quality

Study Methods 6 pathologists 2 Board certified, 4 residents NEC 2690 Color LCD 1920 x 1200 Lmax = 320 cd/m 2 Contrast ratio = 1000:1 Wide gamut Calibrated/color managed & off-the-shelf Counterbalanced min 3 weeks between Rate benign vs malignant Trials timed automatically

Ishihara s Test Color Deficiency

Interface

MRMC ROC Az Reader Uncalibrated Az Calibrated Az 1 0.9003 0.9142 2 0.9747 0.9856 3 0.8235 0.8586 4 0.7827 0.7884 5 0.8098 0.7889 6 0.8015 0.8062 Mean 0.8488 0.8570 F = 0.71 p = 0.4112

Timing Results Average 4.895 sec vs 6.304 sec p = 0.0460

Conclusions 1 st study examine impact calibrating/color managing displays on diagnostic accuracy & interpretation efficiency Diagnostic accuracy equivalent Interpretation speed significantly slower Unless viewed side-by-side do not notice differences

ATA Guidelines Derm Image acquisition: device should allow > 24 bits color; set white balance; attach calibration label (GreTag) at least 1 image (pref all) Image display: max/min luminance, gamma (2.2), white point, color temp 6500 K, bit-depth 24, ambient 20-40 lux; if GreTag doesn t match adjust using display settings function &/or calibration software tools

ATA Guidelines DR Monitors & settings should be validated for clinical diagnostic accuracy. Any validated monitor technology can be used (e.g., cathode ray tube, liquid crystal display, gas plasma panel). Retinal images used for diagnosis should be displayed on high-quality monitors of appropriate size and resolution. Displays should be calibrated regularly to ensure fidelity with original validation display conditions. Revalidation should be performed if settings are changed. Ambient light level, reflections and other artifacts should be controlled to ensure standardized viewing.

ACR Electronic Practice White point: The color characteristics of a display with respect to the presented color space are not considered in this technical standard. However, the white point associated with presentation of grayscale images is important for medical imaging systems. It is recommended that monitors be set to a white point corresponding to the CIE daylight standard D65 white point. This corresponds to a color temperature of about 6,500 F.

When is Color Important? Color displays (MG & COTS) quite good now Luminance, noise, stability etc. Cost reasonable even MG Calibration tools exist should be used! Diagnostic accuracy & workflow affected little Humans vs computers! Image processing & analysis tools require more color fidelity, calibration, color management

Automatic Analyses Automatic tissue classification Diagnostically Relevant (B or M) vs. Irrelevant Application: Efficient region-ofinterest compression for faster digital workflow Benign vs. Malignant Application: Computer-aided diagnosis Task-driven saliency Predict regions most likely to attract expert attention Application: Efficient region-ofinterest compression for faster digital workflow

H&E Color Transformation Isolate info on nuclei & cytoplasm Pixelwise color transform CMY -> HE H shows nuclei, E shows cytoplasm, etc. Pixel distribution CMY color space CMY H (nuclei dark) E (cytoplasm dark)

Relevant vs. Irrelevant Requirements Computationally efficient 100% detection Relevant (True Positive), certain false alarm rate permissible Methodology Relevant Irrelevant Epithelial nuclei & Tubule formation Cytoplasmic tissue Epithelial nuclei & Tubule formation Cytoplasmic tissue Performance Accuracy: 98.8 % cross-validation EER on 400 cropped images Speed: 10 min 4GB slide, can be sped up