String Inverters SUN 2000-KTL, IA240 Series, EM24 DIN, CTD-1X,

Similar documents
Assembly. Front view. LEDs. Parametrization interface. Power Bus

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

02/11/2015

Ordering details. Approval. Classification

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

LONWORKS Fibre Optic Router

Standard RS232 RS ma

LONWORKS Fibre Optic Converter

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

The Three-Phase Inverter Not Only for Your Home...

PRINCIPLES AND APPLICATIONS

Datasheet - SRB301LC 24VAC/DC

PRELIMINARY Sunny Boy 240-US

Datasheet - SRB-E-201ST

Process Transmitter RMA 422

Fibre optic router for TP/FT-10 LRW-112PP

Fibre Optic Modem ODW-611

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Operating Instructions

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Photoelectric Sensors E3F2

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Operating instructions Electronic preset counter Type series 717

SPACESCAN SERIES SS 02

Fibre Optic Modem ODW-622

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

MAP110 AC-DC Series Data Sheet

Time-Lag Relays. User s Handbook (General Model)

AF-300 E11 Adjustable Frequency Drive

Multifunction Digital Timer

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

T +31 (0) F

Electronic converter for level transmitters MT03L Instructions manual

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Rack mounted telephone- and leased line modem for industrial applications

Generator protection relay

Type Contact form Model

Process transmitter RMA422

Electrical connection

DCP100 Digital Control Programmer Specifications

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Solid-State Digital Timer

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Photoelectrics Through-beam Type PA18C.T..., DC

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Light Curtain Type LA

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Electrical connection

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Panel-mounting thermostats, type series EM

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Selection matrix for electronic pressure switches

FLOMAT Electromagnetic Insertion Flowmeter

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

A new generation of access control.

Quick Operation Guide of LTN7700/7600 Series NVR

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

SPECIFICATION ESD FSP500-80MPD. Released Date:2015/07/27-14:41:38

Datasheet IVU.box.touch

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Instruction Manual Model BlockUpconverter

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Multifunction devices

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

Magnecraft Power Relays

multi-function meters

EA350. Generator Automatic Voltage Regulator Operation Manual

FOM-9010, FOM-9011 and FOM-9012

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Product Range Power Supplies

MT03A Electronic converter for flow rate transmitters

Transcription:

Product Certificate Number Applicant 11630-CER Huawei Technologies España Parque Empresarial Las Tablas, Federico Mompou 5, Ed. 1 planta 2 28050 Las Tablas. Madrid, Spain. Series Model/ Variant models Type of generating unit Technical Data See page 2-8 String Inverters SUN 2000-KTL, IA240 Series, EM24 DIN, CTD-1X, SUN2000-36KTL, Moxa / IA240, Carlo Gavazzi / EM24-DIN.AV5.3.D.IS.X, Carlo Gavazzi / CTD-1X.200.5A.XXX Inverters: SUN 2000-8KTL, SUN 2000-12KTL, SUN 2000-17KTL, SUN 2000-20KTL, SUN 2000-23KTL, SUN 2000-28KTL, SUN 2000-33KTL-A, SUN 2000-42KTL Three Phase Inverter / Control Manager / Power Analyzer / Current sensor Standard UNE 207001 IN: 2015: Requisitos y ensayos para sistemas que eviten el vertido de energía a la red de distribución. Having assessed the test report number: 11630-TR performed by Certification Entity for Renewable Energies based on the requirements of the EN ISO/IEC 17025:2005 The above-mentioned generating unit complies with the requirements of the: UNE 207001 IN: 2015: Requisitos y ensayos para sistemas que eviten el vertido de energía a la red de distribución. This certification is according the CERE internal process PET-CERE-09 Rev 11 based on the requirements of the EN ISO/IEC 17065:2012. For this certification process the conformity assessment activities were based on: Testing of production samples selected by CERE. Audit of quality system according ISO 9001 with certificate number: ES13/14411 issued by a certification body accredited according EN ISO/IEC 17021. Inspection of the software implementation process. Madrid, October 6, 2017. This certificate is valid until October 6, 2020 Miguel Martínez Lavin Certification Manager This document cannot be reproduced partially. Nº 11630-CER Page 1 of 9

Inverters: HUAWEI Technical Specifications SUN2000-8KTL SUN2000-12KTL Max. DC Usable Power 9000 W 13500 W Max. Voltage 1000 V 1000 V Max. Current per 18 A 18 A Min. Operating Voltage / Start Voltage 25 A 25 A 200 V / 250 V 200 V / 250 V Full Power Voltage Range 320 V ~ 800 V 380 V ~ 800 V Operating Voltage Range 200 V ~ 950 V 200 V ~ 950 V Rated Voltage 620 V 620 V Max. Number of s 4 4 Number of MPP Trackers 2 2 Rated AC Active Power 8000 W 12000 W Max. AC Apparent Power 8800 VA 13200 VA Max. AC Active Power (cos Φ = 1) 8800 W 13200 W Rated Voltage 220 V / 380 V, 230 V / 400 V, 220 V / 380 V, 230 V / 400 V, Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 13,4 A 20 A Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type II Type II Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº 11630-CER Page 2 of 9

Technical Specifications SUN2000-17KTL SUN2000-20KTL Max. DC Usable Power 19100 W 22500 W Max. Voltage 1000 V 1000 V Max. Current per 18 A 18 A Min. Operating Voltage / Start Voltage 25 A 25 A 200 V / 250 V 200 V / 250 V Full Power Voltage Range 400 V ~ 800 V 480 V ~ 800 V Operating Voltage Range 200 V ~ 950 V 200 V ~ 950 V Rated Voltage 620 V 620 V Max. Number of s 6 6 Number of MPP Trackers 3 3 Rated AC Active Power 17000 W 20000 W Max. AC Apparent Power 18700 VA 22000 VA Max. AC Active Power (cos Φ = 1) 18700 W 22000 W Rated Voltage 220 V / 380 V, 230 V / 400 V, 220 V / 380 V, 230 V / 400 V, Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 28,4 A 33,4 A Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type II Type II Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº 11630-CER Page 3 of 9

Technical Specifications SUN2000-23KTL SUN2000-28KTL Max. DC Usable Power 23600 W 28200 W Max. Voltage 1000 V 1000 V Max. Current per 18 A 18 A 25 A 25 A Max. input current (3 s) 54 A 54 A Min. Operating Voltage 200 V 200 V Voltage Range 480 V ~ 800 V 480 V ~ 800 V Rated Voltage 620 V 620 V Max. Number of s 6 6 Number of MPP Trackers 3 3 Rated AC Active Power 23000 W 27500 W Max. AC Active Power (cos Φ = 1) -- -- Rated Voltage 220 V - 230 V /380 V - 400 V, 227 V / 480 V, 3W+PE Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 33,5 A 33,5 A Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type III Type III Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº 11630-CER Page 4 of 9

Technical Specifications SUN2000-33KTL-A SUN2000-36KTL Max. DC Usable Power 30600 W 40800 W Max. Voltage 1100 V 1100 V Max. Current per 22 A 22 A Min. Operating Voltage / Start Voltage 30 A 30 A 200 V / 250 V 200 V / 250 V Full Power Voltage Range 480 V ~ 800 V 480 V ~ 850 V @380Vac / 400 Vac 580V~850V @480Vac Operating Voltage Range 200 V ~ 1000 V 200 V ~ 1000 V Rated Voltage 620 V 620 V @380Vac / 400Vac 720V @480Vac Max. Number of s 8 8 Number of MPP Trackers 4 4 Rated AC Active Power 30000 W 36000 W Max. AC Apparent Power 33000 VA 40000 VA Max. AC Active Power (cos Φ = 1) 30000 W Default 40000W; 36000W optional in settings Rated Voltage 230 V / 400 V, default 220 V / 380 V, 230 V / 400 V, default ; 3W+PE optional in settings 227V/480V, 3W+PE Rated AC Grid Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Max. Current 48 A (@400V) 60,8 A / 57.8 A / 48,2 A @380V/400V/480V Adjustable Power Factor 0,8 LG 0,8 LD 0,8 LG 0,8 LD -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester Type II Type II AC Surge Arrester Type II Type II Insulation Detection Residual Current Monitoring Unit This document cannot be reproduced partially. Nº 11630-CER Page 5 of 9

Technical Specifications Max. DC Usable Power Max. Voltage Max. Current per Min. Operating Voltage / Start Voltage Full Power Voltage Range Operating Voltage Range Rated Voltage SUN2000-42KTL 47900 W 1100 V 22 A 30 A 200 V / 250 V 580 V ~ 850 V 200 V ~ 1000 V 720 V Max. Number of s 8 Number of MPP Trackers 4 Rated AC Active Power Max. AC Apparent Power Max. AC Active Power (cos Φ = 1) Rated Voltage Rated AC Grid Frequency Max. Current Adjustable Power Factor -side Disconnection Device Anti-islanding AC Overcurrent DC Reverse-Polarity PV-array String Fault Monitoring DC Surge Arrester AC Surge Arrester Insulation Detection Residual Current Monitoring Unit 42000 W 47000 VA Default 47000W; 42000W optional in settings 277 V / 480 V, 3W+PE 50 Hz / 60 Hz 56,6 A 0,8 LG 0,8 LD Type II Type II This document cannot be reproduced partially. Nº 11630-CER Page 6 of 9

Control manager: CPU RAM Flash OS LAN Serial Ports Serial Power input Power consumption Operating temperature Storage temperature Baudrate Moxa/IA240 Moxa ART ARM9 32-bit CPU 192 MHz 64MB 16 MB Linux Auto-sensing 10/100 Mbps x 2 with built-in 1.5 KV magnetic isolation protection; RJ45 Connector RS-232/422/485 4, RJ45 Connector 15 KV ESD for all signals 12 to 48 VDC 7W -10 to 60 C, (14 to 140 F), 5 to 95% RH -20 to 80 C, (-4 to 176 F), 5 to 95% RH 50 bps to 921.6 kbps Relay: Moxa/IoLogik E1214 s and s Digital inputs 6 channels Relay s 6 channels Isolation 3 k VDC or 2k Vrms Digital Sensor Type Wet Contact (NPN or PNP), Dry Contact I/0 Mode DI OR Event Counter Counter frequency 250 Hz Digital Filtering Time Interval Software Configurable Relay Contact current rating Resistive Load: 5 A @ 30 VDC, 250 VAC, 110 VAC Breakdown voltage 500 VAC Relay On/Off time 1500 ms (max.) Power Analyzer: Carlo Gavazzi/EM24-DIN.AV5.3.D.IS.X Range codes Rated Voltage 3x230 V (400) V Current range 0,05 5 (10) A Sampling rate 1600 samples/s @ 50 Hz Operating temperature -25ºC to 55ºC Accuracy 0,5% This document cannot be reproduced partially. Nº 11630-CER Page 7 of 9

Current sensor: Carlo Gavazzi/CTD-1X.200.5A.XXX Specifications Operating frequency 48 to 62 Hz Rated primary current 200A Max. System voltage 0.72 kv Rated insulation level 3 kv/1min. @50 Hz Insulation class E (max 75 ºC) Short-time current rating Ith Typical 100In/1s Idyn 2.5 Ith Specifications Rated secondary current 5 A Accuracy 0,5% Switch of grid (Contactor): Contactor application Utilisation category System Voltage Ie rated operational current Uc control circuit voltage Overvoltage category I th Ui rated insulation voltage Schneider/LC1DT80AF7 Resistive load AC-1 690 V AC 25 400 Hz power circuit 80 A 110 V III 80 A 690 V This document cannot be reproduced partially. Nº 11630-CER Page 8 of 9

Electrical Diagram: The sample selected to test was representative of the production. The sample was selected in: (1) Huawei Technologies España Parque empresarial Las Tablas, Federico Mampou 5, edificio 1 28050 Madrid (2) Green Power Monitor Av. de Josep Tarradellas, 123-127 08029 Barcelona, Spain Sample Report Number: The inspection of manufacturing process was performed in: On October 5, 2017 Inspection Report Number: (1) 11630-1-TM (2) 11630-2-TM Tempel Group Carrer del Cobalt, 4 08907 L'Hospitalet de Llobregat Barcelona, Spain 11630-IF This document cannot be reproduced partially. Nº 11630-CER Page 9 of 9