DICOM Correction Proposal

Similar documents
In PS 3.3, Section C RT Ion Beams Session Record Module, add the following attributes and make the changes indicated:

DICOM Correction Proposal

Implementing a Proton Beam Scanning System within an Operating Clinical Facility

DICOM Correction Item

Promises and Perils of Proton Therapy Beam Delivery (Implications) or Towards Cost Effective Particle Therapy

The following references and the references contained therein are normative.

Hall-B Beamline Commissioning Plan for CLAS12

Preface 11 Key Concept 1: Know your machine from a programmer s viewpoint 17

A NOVEL GANTRY FOR PROTON THERAPY AT THE PAUL SCHERRER INSTITUTE

CS2401-COMPUTER GRAPHICS QUESTION BANK

Figure 1. MFP-3D software tray

Industrial Diode Laser (IDL) System IDL Series

Revision 1.2d

Impact of DMD-SLMs errors on reconstructed Fourier holograms quality

-Technical Specifications-

ITU-T Y.4552/Y.2078 (02/2016) Application support models of the Internet of things

Particle Beam Production - A Synchrotron-Based System - Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

40G SWDM4 MSA Technical Specifications Optical Specifications

Quality Assurance Implementation at the Roberts Proton Therapy Center. James McDonough 3 August 2013

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Bar Codes to the Rescue!

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

ISO/IEC INTERNATIONAL STANDARD

Application Note 11 - Totalization

40G SWDM4 MSA Technical Specifications Optical Specifications

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Coding of moving video

National Institute of Radiological Sciences. Naoya Saotome

G0 Laser Status Parity Controls Injector Diagnostics

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Data Collection Using APEX3. March 30, Chemical Crystallography Laboratory

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

DICOM Conformance Statement

CS 151 Final. Instructions: Student ID. (Last Name) (First Name) Signature

THE FROG SERIES OPERATING MANUAL

LCD MODULE SPECIFICATION

The trigger for the New Electromagnetic Calorimeter NewCal

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

User Manual. Applications. See for more detailed information. Manual Version: Software Version: 2.03.

Connection for filtered air

Capital Works process for Medium Works contracts

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

Panel Light II Datasheet

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

XRD-DSC Sample Alignment (BB) Part

Glast beam test at CERN

An Introduction to TrueSource

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

Table of Contents. 2 Select camera-lens configuration Select camera and lens type Listbox: Select source image... 8

using the Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

FIBRE CHANNEL CONSORTIUM

In-process inspection: Inspector technology and concept

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

FREE TV AUSTRALIA OPERATIONAL PRACTICE OP- 59 Measurement and Management of Loudness in Soundtracks for Television Broadcasting

Training Note TR-06RD. Schedules. Schedule types

Three Axis Digital Readout System

PEP-I1 RF Feedback System Simulation

Fast Ethernet Consortium Clause 25 PMD-EEE Conformance Test Suite v1.1 Report

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Madero Ote. 686, Centro Histórico, C.P Morelia, Michoacán México. #300, Col. Cuauhtémoc, C.P Morelia, Michoacán, México

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

GUIDELINES FOR VHF/UHF SUBMISSIONS RELATED TO TERRESTRIAL BROADCASTING SERVICES (outside the frequency and geographical scope of GE06 Agreement)

How Quadrupole Size Affects Research

PSM-003. Micro Polarization Controller/Scrambler. User Guide

SRV02-Series. Ball & Beam. User Manual

LED driver architectures determine SSL Flicker,

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

DICOM Conformance Statement. CD-Medical Recorder for DCI systems CDM Release Document Number July 1998

TOMELLERI ENGINEERING MEASURING SYSTEMS. TUBO Version 7.2 Software Manual rev.0

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

CertaFlux LED Systems Linear & Area Sometimes good can be great CertaFlux LED systems are designed to enable LED luminaires for high volume markets

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

Allen-Bradley D. User Manual. Hand-Held Decoded Bar Code Scanners. (Cat. No HDG-4)

Acquisition Control System Design Requirement Document

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Maintenance Service Bulletin

Concept of Operations (CONOPS)

SRV02-Series. Rotary Pendulum. User Manual

Understanding Multimode Launching Conditions and TIA TSB-178

USER DOCUMENTATION. How to Set Up Serial Issue Prediction

NVISION Compact Space and cost efficient utility routers

ISOMET. Compensation look-up-table (LUT) and How to Generate. Isomet: Contents:

A Test Lab Techno Corp. FCC. RF Test Report. Product Type. : Mobile Hotspot. Applicant. : Netgear Inc.

SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION

Synergy SIS Attendance Administrator Guide

Hybrid pixel detectors

INTERNATIONAL STANDARD

SIDRA INTERSECTION 8.0 UPDATE HISTORY

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Composite Distortion Measurements (CSO & CTB)

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

Mini Micro Pulse Lidar System

Transcription:

DICOM Correction Proposal STATUS Final Text Date of Last Update 2015/11/16 Person Assigned Submitter Name Ulrich Busch (ulrich.busch@varian.com) Michael Moyers Submission Date 2011/05/19 Correction Number CP-1432 Log Summary: Add Support for Ion Therapy Scanning Modes Name of Standard PS3.3 2105c Rationale for Correction: Some manufacturers may support more than one type of delivering beam between control spots during treatment using the Modulated Scanning Mode. This Change Proposal adds Additional Defined Terms to defined the delivery mode and specific the details, how the Scan Spot Position Map (300A,0394)and Scan Spot Meterset Weights (300A,0396) is used. At the time Supplement 102 was devised, the Ion Subgroup Committee felt that each installation would support only one method of delivery with the modulated scanning mode and that the treatment planning system and beam delivery system would have a matched set of information. The Supplement 102 method of transmitting information works for ions delivered only at discrete aiming points, ions delivered continuously along a line between two aiming points, or ions delivered mostly at discrete aiming points but with the beam left on as the aiming point moves quickly between one location and another. The devised method also works for energy stacking before lateral scanning but it is not as efficient. Since Supplement 102 was published, some equipment has been made that supports multiple methods of modulated scanning delivery. It turned out that at least one manufacturer may support more than one method of modulated scanning even between control points, and other may go onto the same path. It was thus identified that a tight definition of scanning modes needs to be inserted into the standard. The members see the need that the use of multiple modulated scanning modes must be explicitly specified, rather than relying on the correct interpretation of the DICOM standard with out-of band information. This CP addressed these concerns by tightening the Scan Mode definitions. An alternative approach to introduce an additional sub-scan-mode attribute is not indicated, since that attribute is not be read by existing applications. Rather than the existing attribute Scan Mode (300A,0308) is a mandatory attribute and though the use of Defined Terms is designed to be extensible exactly for the purpose to address the situation described above, where new advances in technology require tighter and / or additional terms to specify new scan modes. [Comment: Hologic: add some missing underscore highlighting; remaining questions about why not add "or MODULATED_SPEC" to all attributes instead of just some and different in the two tables? U. Busch: Tx for the observation: RESOLVED] Correction Wording: In PS 3.3, modify section C.8.8.25 RT Ion Beams Module, Table C.8.8.25-1 Attribute Name Tag Type Attribute Description Ion Beam Sequence (300A,03A2) 1 Introduces sequence of setup and/or treatment beams for current RT Ion Plan. One or more items shall be included in this Page 1

sequence. >Beam Number (300A,00C0) 1 Identification number of the Beam. The value of Beam Number (300A,00C0) shall be unique within the RT Ion Plan in which it is created. See Section C.8.8.25.1. >Scan Mode (300A,0308) 1 The method of beam scanning to be used during treatment. Defined Terms: NONE = No beam scanning is performed. UNIFORM = The beam is scanned bbetween control points, the beam is scanned to create a uniform lateral fluence distribution across the field. MODULATED = The beam is scanned bbetween control points, the beam is scanned to create a modulated lateral fluence distribution across the field. MODULATED_SPEC = Between control points, the beam is scanned to create a modulated lateral fluence distribution across the field. The specific scan mode is defined by Modulated Scan Mode Type (300A,0309). >Modulated Scan Mode Type (300A,0309) 1C Defines the specialization of a modulated scan mode. Defined Terms: STATIONARY = The Meterset is delivered while the beam spot is at the specified position. LEAPING = The delivery of the specified Meterset for the current spot position begins when the spot is at the previous spot position but the spot moves as quickly as possible to the current specified spot position where most of the Meterset is delivered. LINEAR = The beam spot is delivered with uniform flux while traveling from one position to the next position (continuous). MIXED = Between control points the beam may be delivered by a combination of STATIONARY, LEAPING or LINEAR modes. MODULATED_SPEC. See Section C.8.8.25.X. >Ion Control Point Sequence (300A,03A8) 1 Sequence of machine configurations describing Ion treatment beam. The number of items shall be identical to the value of Number of Control Points Page 2

(300A,0110). See Section C.8.8.25.7. >>Control Point Index (300A,0112) 1 Index of current Control Point, starting at 0 for first Control Point. >>Cumulative Meterset Weight (300A,0134) 2 Cumulative weight to current control point. Cumulative Meterset Weight for the first item in Control Point Sequence shall always be zero. Cumulative Meterset Weight for the final item in Ion Control Point Sequence shall always be equal to Final Cumulative Meterset Weight. >>Beam Limiting Device Rotation Direction (300A,0121) 1C Direction of Beam Limiting Device Rotation when viewing beam limiting device (collimator) from radiation source, for segment following Control Point. Required for first item of Control Point Sequence, or if Beam Limiting Device Rotation Direction changes during Beam. See Section C.8.8.14.8. Enumerated Values: CW clockwise CC counter-clockwise NONE no rotation >>Scan Spot Tune ID (300A,0390) 1C User-supplied or machine code identifier for machine configuration to produce beam spot. This may be the nominal spot size or some other machine specific value. MODULATED or MODULATED_SPEC. >>Number of Scan Spot Positions (300A,0392) 1C Number of spot positions used to specify scanning pattern for current segment beginning at control point. Required if Scan Mode (300A,0308) is MODULATED or MODULATED_SPEC. >>Scan Spot Position Map (300A,0394) 1C The x and y coordinates of the scan spots are defined as projected onto the machine isocentric plane in the IEC GANTRY coordinate system (mm). Required if Scan Mode (300A,0308) is MODULATED or MODULATED_SPEC. Contains 2N values where N is the Number of Scan Spot Positions (300A,0392). See Section C.8.8.25.X >>Scan Spot Meterset Weights (300A,0396) 1C A data set of Meterset weights Page 3

corresponding to scan spot positions. The order of weights matches the positions in Scan Spot Positions (300A,0394). The sum contained in all Meterset weights shall match the difference of the cumulative Meterset weight of the current control point to the following control point. Required if Scan Mode (300A,0308) is MODULATED or MODULATED_SPEC. See Section C.8.8.25.X >>Scanning Spot Size (300A,0398) 3 The Scanning Spot Size as calculated using the Full Width Half Maximum (FWHM). Specified by a numeric pair - the size measured in air at isocenter in IEC GANTRY X direction followed by the size in the IEC GANTRY Y direction (mm). >>Number of Paintings (300A,039A) 1C The number of times the scan pattern given by Scan Spot Position Map (300A,0394) and Scan Spot Meterset Weights (300A,0396) shall be applied at the current control point. To obtain the Meterset weight per painting, the values in the Scan Spot Meterset Weights (300A,0396) should be divided by the value of this attribute. MODULATED or MODULATED_SPEC. C.8.8.25.X Scan Spot Maps The Scan Spot Position Map (300A,0394) and Scan Spot Meterset Weights (300A,0396) shall be used as follows. The following specifies for each value of Modulated Scan Mode Type (300A,0309) the definition of the map which is included in the Control Point 1 having Cumulative Meterset Weight (300A,0134) = 20, followed by a Control Point 2 having Cumulative Meterset Weight(300A,0134) = 20. If Modulated Scan Mode Type (300A,0309) is STATIONARY or LEAPING: Position (X,Y) Meterset Weights (1.0, (3.0, (5.0, (7.0, (9.0, 5 4 6 2 3 Delivery Description: The beam is positioned at Scan Spot Position (1.0, The beam is delivered with a Cumulative Meterset Weight of 5. The beam is switched off or quickly moved and positioned at Scan Spot Position (3.0, The beam is delivered with a Cumulative Meterset Weight of 4. Page 4

The beam is switched off or quickly moved and positioned at Scan Spot Position (5.0, The beam is delivered with a Cumulative Meterset Weight of 6. The beam is switched off or quickly moved and positioned at Scan Spot Position (7.0, The beam is delivered with a Cumulative Meterset Weight of 2. The beam is switched off or quickly moved and positioned at Scan Spot Position (9.0, The beam is delivered with a Cumulative Meterset Weight of 3. If Modulated Scan Mode Type (300A,0309) is LINEAR: Position (X,Y) Meterset Weights (1.0, (3.0, (5.0, (7.0, (9.0, 0 4 6 7 3 Delivery Description: The beam is positioned at Scan Spot Position (1,.0 The beam is continuously delivered with a Cumulative Meterset Weight of 4, while being moved from Scan Spot Position (1.0, to Scan Spot Position (3.0, The beam is continuously delivered with a Cumulative Meterset Weight of 6, while being moved from Scan Spot Position (3.0, to Scan Spot Position (5.0, The beam is continuously delivered with a Cumulative Meterset Weight of 7, while being moved from Scan Spot Position (5.0, to Scan Spot Position (7.0, The beam is continuously delivered with a Cumulative Meterset Weight of 3, while being moved from Scan Spot Position (7.0, to Scan Spot Position (9.0, If Modulated Scan Mode Type (300A,0309) is MIXED: Position (X,Y) Meterset Weights (1.0, (1.0, (3.0, (5.0, (5.0, (7.0, (7.0, 0 4 6 5 2 0 3 The beam is positioned at Scan Spot Position (1.0, The beam is delivered with a Cumulative Meterset Weight of 4 while staying at Scan Spot Position (1.0,. The beam is continuously delivered with a Cumulative Meterset Weight of 6, while being moved from Scan Spot Position (1.0, to Scan Spot Position (3.0, Page 5

The beam is continuously delivered with a Cumulative Meterset Weight of 5, while being moved from Scan Spot Position (3.0, to Scan Spot Position (5.0, The beam is delivered with a Cumulative Meterset Weight of 2 while staying at Scan Spot Position (5.0,. The beam is switched off or quickly moved and positioned at Scan Spot Position (7.0, The beam is delivered with a Cumulative Meterset Weight of 3 while staying at Scan Spot Position (7.0,. In PS 3.3, modify section C.8.8.26 (RT Ion Beams Session Record Module), Table C.8.8.26-1 Attribute Name Tag Type Attribute Description Treatment Session Ion Beam Sequence (3008,0021) 1 Introduces sequence of setup and/or treatment beams administered during treatment session. One or more items shall be included in this sequence. >Referenced Beam Number (300C,0006) 1 References Beam specified by Beam Number (300A,00C0) in Ion Beam Sequence (300A,03A2) in RT Ion Beams Module within the referenced RT Ion Plan. >Scan Mode (300A,0308) 1 The method of beam scanning to be used during treatment. Defined Terms: NONE = No beam scanning is performed. UNIFORM = The beam is scanned bbetween control points, the beam is scanned to create a uniform lateral fluence distribution across the field. MODULATED = The beam is scanned bbetween control points, the beam is scanned to create a modulated lateral fluence distribution across the field. MODULATED_SPEC = Between control points, the beam is scanned to create a modulated lateral fluence distribution across the field. The specific scan mode is defined by Modulated Scan Mode Type (300A,0309). >Modulated Scan Mode Type (300A,0309) 3 Defines the specialization of a modulated scan mode. Defined Terms: STATIONARY = The Meterset is delivered while the beam spot is at the specified position. LEAPING = The delivery of the specified Meterest for the current spot position Page 6

begins when the spot is at the previous spot position but the spot moves as quickly as possible to the current specified spot position where most of the meterset is delivered. LINEAR = The beam spot is delivered with uniform flux while traveling from one position to the next position (continuous). MIXED = Between control points the beam may be delivered by a combination of STATIONARY, LEAPING or LINEAR modes. Required, if Scan Mode (300A,0308) is MODULATED_SPEC. See Section C.8.8.25.X. >Ion Control Point Delivery Sequence (3008,0041) 1 Sequence of beam control points for current ion treatment beam. One or more items shall be included in this sequence. The number of items shall be identical to the value of Number of Control Points (300A,0110). See Section C.8.8.21.1. >>Beam Limiting Device Rotation Direction (300A,0121) 1C Direction of Beam Limiting Device Rotation when viewing beam limiting device (collimator) from radiation source, for segment beginning at current Control Point. Required for Control Point 0 of Ion Control Point Delivery Sequence (3008,0041) or if Beam Limiting Device Rotation Direction changes during beam administration. Enumerated Values: CW clockwise CC counter-clockwise NONE no rotation >>Scan Spot Tune ID (300A,0390) 1C User-supplied or machine code identifier for machine configuration to produce beam spot. This may be the nominal spot size or some other machine specific value. MODULATED or MODULATED_SPEC. >>Number of Scan Spot Positions (300A,0392) 1C Number of spot positions used to specify Page 7

scanning pattern for current segment beginning at control point. Required if Scan Mode (300A,0308) is MODULATED or MODULATED_SPEC. >>Scan Spot Position Map (300A,0394) 1C The x and y coordinates of the scan spots are defined as projected onto the machine isocentric plane in the IEC GANTRY coordinate system (mm). Required if Scan Mode (300A,0308) is MODULATED or MODULATED_SPEC. Contains 2N values were N is the Number of Scan Spot Positions (300A,0392). See section C.8.8.25.X >>Scan Spot Metersets Delivered (3008,0047) 1C A data set of Metersets delivered to the scan spot positions. The order of Metersets matches the positions in Scan Spot Position Map (300A,0394). The sum contained in all Metersets shall match the difference of the Delivered Meterset of the current control point to the following control point. Required if Scan Mode (300A,0308) is MODULATED or MODULATED_SPEC. See section C.8.8.25.X >>Scanning Spot Size (300A,0398) 3 The Scanning Spot Size as calculated using the Full Width Half Maximum (FWHM). Specified by a numeric pair - the size measured in air at isocenter in IEC GANTRY X direction followed by the size in the IEC GANTRY Y direction (mm). >>Number of Paintings (300A,039A) 1C The intended number of times the scan pattern given by Scan Spot Position Map (300A,0394) and Scan Spot Meterset Weights (300A,0396) in the Referenced RT Plan was to be applied at the current control point. Note The actuaxl number of paintings is not known or recorded. The Scan Spot Metersets Delivered (3008,0047) contains the sum of all complete and partial repaints. MODULATED or MODULATED_SPEC. In PS 3.6, Section 6, add the following new attributes: (300A,0309) Modulated Scan Mode Type ModulatedScanModeType CS 1 Page 8