MICROPROCESSOR CALCULATION MODULE - S2000

Similar documents
2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Capacitance Level Measurement Electronic insert FEC 12

Operating instructions Electronic preset counter Type series 717

PRINCIPLES AND APPLICATIONS

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Process transmitter RMA422

LAUREL ELECTRONICS, INC.

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Analogue output module DAO 081

Process Transmitter RMA 422

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

FLOMAT Electromagnetic Insertion Flowmeter

Capacitance Limit Detection nivotester FTC 420/421/422

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Hour Meters / Timers, electronic

HOBO H Energy Logger

Preset counters, electronic

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

SCALE & WEIGHT DISPLAYS

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Rack mounted telephone- and leased line modem for industrial applications

DCP100 Digital Control Programmer Specifications

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Wall-/Pipe-Mount Level Indicator

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Model KBF 115 Constant climate chambers with large temperature / humidity range

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

800 Displaying Series Flowmeter

Assembly. Front view. LEDs. Parametrization interface. Power Bus

263 Series LED Bargraph Indicator and Controllers

UNIGAS Hand-held combustion gas analyzer with 3 sensors

Operating Instructions

Operating Instructions

Micro-DCI 53ML5100 Manual Loader

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Standard signal metering in wall-mounting case

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Model IQ4-PC User Manual Revision Date:

multi-function meters

Henkel Installation Handbook LINEGUARD 2001

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Multifunction devices

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

02/11/2015

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

User Manual. for. Panel mounted instrument

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

If you have questions or problems in providing anything described as Customer

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Model KBF P 240 Humidity test chambers with ICH-compliant light source

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

TriLIN Program Utility TPU_ TriLIN Programming Manual

RMA42. Technical Information

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Simply clever! The digital DIN-rail time switches by Grässlin

Model Number Structure

Single Point Flow Monitor SW118 SW119

Model KT 53 Cooling incubators with thermoelectric cooling

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Programmable Power Supplies 188 W 384 W R&S HMP Series

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Sensopress LCD Special English

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Accessories. Servo Motors. Servo Motors B-47. Accessories

Signal Stability Analyser

Generator protection relay

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Time meter electronic

Solution Selection Guide

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Fibre optic router for TP/FT-10 LRW-112PP

48x24. Options ORDER NUMBER OF TYPE PFL B

AF-300 E11 Adjustable Frequency Drive

16-BIT LOAD CELL/DUAL STATUS INPUT

Eaton Durant. Counters, process instruments and hour meters.

istep STEPPER MOTOR PUMP

Transcription:

MICROPROCESSOR CALCULATION MODULE - S2000 Complying equipments with prescriptions on electromagnetic compability (standard 89/336/CEE.) Industrial environment, reference standard : EN 50081-2 EMISSION /EN 50082-2 Immunity Calculation module operating on both analogue and digital signals. Permits any calculation between input quantities, providing the outputs corresponding to the calculation performed. Provided with: 4 analogue inputs for 0-20 ma or 4-20 ma passive signals, with 100 ohm input resistance; 12 bit analogue/digital conversion. 2 digital inputs for drive from contact (free voltage) or open collector npn transistor (1 ma 5 Vdc). 2 analogue outputs with 0-20 ma or 4-20 ma active signal (max 300 ohm); 12 bit analogue/digital conversion not galvanically separated. 2 digital outputs with output by means of open collector npn transistor with maximum capacity 300 ma 30 Vdc. RS 232 optoisolated standard serial interface for connection to computer. On request, optoisolated RS 485 interface with possibility of connection to computer via duplex cable up to 32 modules. The software implemented in the S2000 module permits acquisition of input quantities and reception of output values via the computer. The configuration software supplied on floppy disk for MS-DOS systems permits total programmability of the calculations and operations performed by the module directly via computer. The configuration data of the S2000 module are written on EEPROM and are therefore retained for over 10 years even with no power supply. On request the instrument can be factory-programmed to specific customer requirements, with related instructions for use. 115 / 230 Vac mains power supply selectable in the field, protected against line overvoltages by means of varistors. The insulation between the mains supply and the input and output circuits is 4500 Volt. The case is of the DIN type with 9 modules, made of self-extinguishing Noryl and designed to fit on a 35 mm mounting rail (DIN 46277). Application examples: Transmission of analogue signals from process transducers to a computer via serial line. Adder of two flow rate signals to control a metering pump, for example. Any situation where it is necessary to perform a calculation or linearisation between the input quantities. Integration and counting of calories/refrigeration units. Pressure and temperature compensated flow rate measurements. Calculation of input measurements and transmission of results on output signals. SENECA EN 11.99

TECHNICAL SPECIFICATIONS Power supply: Power consumption: 3.5VA Inputs: 4 analogue 0-20 ma or 4-20 ma passive, input resistance 100 ohm, 2 digital for contact or npn (1 ma 5 Vdc) ADC conversion speed: 160 ms per channel Outputs: 2 analogue 0-20mA or4-20 ma active (max load 300 ohm) 2 digital npn open collector (300 ma 20 Vdc) 1 RS 232 serial line, RS 485 optional DAC conversion speed: 10 ms per channel Calibration: greater than 0.1 % Drift: below 50 ppm Operating temp.: 0 / +60 C Humidity: 90 % at 40 C (non-condensing) Dimensions (b x h x d) : 157.5 x 95 x 69 mm Weight: approx. 500 g DIMENSIONS SENECA Via Pellizzo, 14/A - 35128 PADOVA - ITALY Tel. +39 049 775966-775200 - 8078578 Fax +39 049 775230-775686 e-mail: info@seneca.it Internet: www.seneca.it The technical specifications may be altered without notice.

APPLICATION EXAMPLES OF THE MICROPROCESSOR CALCULATION MODULE S2000 GENERAL DESCRIPTION Mathematical microprocessor unit designed to solve easily and at low cost any calculation problem on analogue and digital signals. Essential for calculation of means, differences, integration of signals etc. for transmission to an indicator, a recorder or directly to a personal computer, acting like an intelligent acquisition card. The module offers 4 inputs for analogue signals, 2 inputs for digital signals, 2 outputs for analogue signals, 2 outputs for digital signals and an RS232 or RS485 interface for direct connection of several S2000 modules on the same serial line to a personal computer. The complete set of logic-mathematical operations implemented is described below. The calculation to be performed is set directly by the user by connecting the S2000 module to the serial socket of his personal computer and writing a simple sequence of instructions which at the end is transmitted to an EEPROM memory within the module. The storage technology used retains the programming even with no power for at least 10 years and the module can be directly reprogrammed for new operations whenever necessary. On request it is also possible to program the module directly in the factory before shipment according to specific customer requirements. EXAMPLES OF USE ANALOGUE OR DIGITAL SIGNAL ACQUISITION MODULE An example of very common use of the S2000 calculation module is acquisition and transmission via serial line of the analogue and digital signals from process transducers to a personal computer, as in the case of measurement of flow rate, pressure, level, temperature etc. In addition to transmission via serial line, the S2000 module can perform logic-mathematical calculations on the input signals and send the outputs to indicators or recorders. The signals from transducers go to the analogue inputs of the S2000, which in its turn can use them or otherwise in required logic-mathematical operations and then retransmit the corresponding values via serial line to the PC for display. The PC can also transmit to the S2000 module via serial line the required information for control of devices such as valves or pumps, connected to the analogue outputs of the module itself. SENECA EN 12.99

MEAN VALUE OF ANALOGUE SIGNALS Another example of widespread use is calculation of the mean of the values provided by process transducers as in the case of various PT100 temperature probes located at different heights in a liquid tank. The S2000 module can assess the mean of the values corresponding to the analogue signals from the probes and control a temperature regulator on the basis of this mean. CREATION OF A CALORY COUNTER OR REFRIGERATION UNIT COUNTER The creation of a calory or refrigeration unit counter is an example of one of the many uses of the S2000 calculation module in the field of analogue value integrations. As a calory counter the S2000 is able to totalise the thermal energy developed in a pipe used for heating, for example, calculating the difference between the two temperatures, high and low, provided by two PT100 probes and multiplying it by the flow rate of the pipe measured by means of a magnetic meter.

CONTROL OF A METERING PUMP The S2000 calculation module also has many uses in the field of digital value integrations, for example control of a metering pump by averaging two flow rate pulse signals. MEASUREMENT OF MASS IN GASES In various applications determination of the flow rate is required, for example in kilograms, of a gas like water vapour or methane. The S 2000 module can provide an output analogue signal proportional to the above mass, combining the gas flow rate, measured by means of a Venturi pipe or a calibrated flange or a Vortex etc., with the temperature and pressure of the gas.

PROGRAMMING THE SET OF OPERATIONS THAT CAN BE PERFORMED BY THE S2000 CALCULATION MODULE IS DESCRIBED BELOW The program instructions entered by the user consist of operands and operations. The operands can be constant numbers which the user enters directly, or the values present at the analogue or digital inputs that can be entered via the Input/Output operations. The operations, depending on their type, act on the last operand entered or on the last two. To enter the required operation, the user must use the related code. The description of the set of operations controlled by the S2000, complete with their codes, is divided as follows: MATHEMATICAL OPERATIONS + addition of the last two operands - subtraction of the last two operands * multiplication of the last two operands / division of the last two operands NEG opposite of the value of the last operand RADQ square root of the last operand which must be non-negative LOG base 10 logarithm of the last operand which must be positive LN natural logarithm of the last operand which must be positive EXP10 base 10 power of the last operand EXPE base e power of the last operand EXP power with base and exponent corresponding to the last two operands LOGIC OPERATIONS DUP DEL SWAP COMP SWITCH NOT INTEGRATION OPERATIONS PVAL1, PVAL2 IVAL1, IVAL2 ITYPE DATA STORAGE OPERATIONS STO0, STO1, STO2, STO3, STO4 RCL0, RCL1, RCL2, RCL3, RCL4 I/O OPERATIONS AI1, AI2, AI3, AI4 AO1, AO2 DI1, DI2 DO1, DO2 duplicates the value of the last operand eliminates the last operand swaps the last two operands compares the last two operands selects one of the two previous operands on the basis of the last operand negates the value of the last operand last operand as value associated with the pulse for the 2 digital outputs last operand as a variable to be integrated choice of type of integration, digital or analogue 5 memory registers of the operand values recovery of values of the operands from the memory registers recovery of value present in one of the 4 analogue inputs transfer of last operand to one of the 2 analogue outputs recovery of value present in one of the 2 digital inputs transfer of last operand to one of the 2 digital outputs ZERO REGULATION OPERATIONS ZA adds shifting of the zero to the last operand ZS removes shifting of the zero to the last operand SENECA Via Pellizzo, 14/A - 35128 PADOVA - ITALY Tel. +39 049 775966-775200 - 8078578 Fax +39 049 775230-775686 e-mail: info@seneca.it Internet: www.seneca.it The technical specifications may be altered without notice.