Instruction manual. Midi Fiber Dome. Instruction manual

Similar documents
OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Optical Distribution Box 300 Installation Guide. Version : R0.0

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Gel-sealed in-line fiber optic closure

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2178-L/S Series Fiber Optic Splice Case with Gasket

INSTALLATION INSTRUCTIONS

Medium Box for Cable Termination

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Fiber Optic Splice Closure GPJ Instruction Manual

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Distribution Box (DDB)

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

FOSC-450 Product Range Ordering Guide

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

IP-LINX Fiber :: X-XXXX

FOSC 450 C6 and D6 Closures

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

27mm ECAM Double Cable Entry Port

18mm ECAM Cable Entry Port

FOSC 400 A4 Fiber Optic Splice Closure

IP-LINX. Installation Guide

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Bionic Elephant Trunk. Assembly Instructions

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

HCS - HES Cabling Systems

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

VITALink Taped Splice Straight Through Crimp

Installation Instructions

INSTALLATION INSTRUCTIONS

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

Panduit Recommended Best Case Practice Split Fibre

SLiC Fiber Aerial Closure System

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

Fiber ICT. Optical Fiber Catalogue

Instructions. Cable with Armor F CAUTION. October Rev A

INSTALLATION INSTRUCTIONS MO023A

3 SLiC Aerial Closure with Rubber End Seal

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

Seal Kits for BUDI Enclosures

DOME OPTIC SPLICE CLOSURE

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

3M Better Buried Closures

TECHNICAL SPECIFICATION

3M Better Buried Compound Compression Closure System

3A TC 699/SIP/UK/12

Hardware installation

Water blocking tape. Locator ridge HPA-0486

FOSC 400 A4. Fiber Optic Splice Closure. 1. General Product Information I N S T A L L A T I O N I N S T R U C T I O N S

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

LEGEND POWER SYSTEMS

GCO2-BC6/16-MC-XV GCO2-BD6/16-MC-XV GCO2-BE6/16-MC-XV. 3.1 Installation of the workstand 3.2 Opening the FIST-GCO2

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

FOSC 400 C5 & D5 Fiber Optic Splice Closures

WaterVue TV Installation & User Manual

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

Aruba Outdoor AP Antenna Weatherproofing

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

4125 system setup and deployment quick start guide

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

Crimp & Cleave Termination Instructions for SEL ST Connectors


3M Fiber Optic Wall Mount Enclosure 8430 Series

DLMP-45/45R Installation Instructions

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

DLMP Installation Instructions

Installation instructions Roxtec CF 16 EMC and Roxtec CF 16 O EMC

GENUINE PARTS CAUTION

Customer-Owned Outside Plant

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

Public Works Division Lighting District Fiber Optic Specifications April 2009

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

FELIX3.1 assemblymanual

INSTALLATION INSTRUCTIONS

SPECIFICATION. Spec No : VSS-1402-CS603B

Coyote popup display set up instructions

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

3M Cold Shrink Splice Kit QS-III 5515A

Transcription:

Midi Fiber Dome Instruction manual Product contents: - 1x Midi Fiber Dome - 1x Window Cut port seal - 1x sealing rubber (long) - 4x sealing rubber (short) - 4x stainless steel screw 4 x 25 T20-6x dummies (to seal unused ports) - 1x tube silicone grease Required tools Torx T20 screwdriver Clamp Measuring tape, permanent marker, cable knife, side-cutting pliers and Kevlar scissors. Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 1 van 7

Mounting a Midi Fiber Dome 1. Secure the MFD by using a vise or a clamp Prepare the cables and/or ducts with the correct length (take the prescribed overlength into account) 2. Make a window cut in the feeder cable Mark the feeder cable at 4cm from the end where the cable was opened Place a short peace of the sealing rubber at this markation point Shorten the strength element at 4 cm from where the cable was opened Attention: in case a window cut is not necessary, carry out step 2 for the single feeder cable 3. Enter the window cut in the Midi Fiber Dome and directly fixate the strength element(s) under the cover plates Use a T20 screwdriver to tighten the strength elements under the metal plates Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 2 van 7

4. Break out the port(s) where a cable has been inserted 5. Place the inner part of the Window Cut port seal over the feeder cable until the triangles are aligned 6. Roll the long piece of sealing rubber into the shape of a sausage and divide it equally into the port. 7. Fixate the outer part of the Window Cut port seal Again use a T20 screwdriver for tightening the 3 screws Attention: Hold the inner part of the Window Cut port seal when tightening the 3 screws Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 3 van 7

. 8. If a black edge of rubber is visible around the Window Cut port seal, the seal is made correctly. If the black edge of rubber is not visible, the rubber is not well divided. Port seal must be unscrewed, re-divide rubber (step 6) and step 7 must be redone until rubber edge is visible 9. Place the overlength of the tubes / fibers that are not being used under the velcro 10. Bring the tubes / fibers that need to be spliced to the other side where the cassettes are placed Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 4 van 7

11. Strip the tubes from the markation point as shown in the picture 12. The tube(s) can optionally be extra fixated with a tie-wrap Attention: do not tighten tie-wrap too tightly 13. Cut the outer sleeve of the cable / duct perpendicularly. There must not be any lengthways cuts past the end. Use alcohol to remove any grease from the first 4 cm of the cable / duct Rub a thin layer of the silicone grease provided on the outer end of the duct / cable 14. Insert the customer cables and / or ducts until the end stop (see red arrow) Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 5 van 7

In case of DB microduct entry: Provide gas seal between fiber and duct. The transparent end stop can be turned around so that the end stop is slightly further (see black arrow) and extra space has been created for a gas seal 15. Strip the tubes at the end of the tube guide (or before the tube guides) Attention: it is important that tubes are not stripped halfway the tube guide due to the possibility of kinking the tubes Splice the Fibers according to the instructions. Place the Fibers in the splice tray according to the splice diagram. 16. Feed the Velcro through the top cassette, and then return it and press it 17. Place dummies in the customer ports without a cable / duct Rub a thin layer of the silicone grease provided on the insert length of the dummy. Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 6 van 7

18. Place the dome on the bottom Attention: it is important that the dome is completely connected to the bottom. By placing the top of the dome on, for example, a workbench you can more easily press them together 19. Place the red closing ring over the dome and turn it until it is completely locked End instruction manual Instruction manual V1.0 _ 09-10-2018 _ Midi Fiber Dome _ Pagina 7 van 7