Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Similar documents
ISLAND HALL TECHNICAL INFORMATION

New Theatre Royal Lincoln Technical Information

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specification for the Alley Theatre, Strabane

INFORMATION FOR VISITING COMPANIES

DEREHAM MEMORIAL HALL

HIRE AND TECHNICAL INFORMATION

Technical Specification

Technical Specification Pavilion Dance

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Services and Specification

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Marjorie S. Deane Little Theater

Technical Specification

Matt Dann Cultural Centre

JERWOOD VANBRUGH THEATRE

Technical Specifications Updated 01/10/2017. Stage

Technical Specifications

Pleasance London Main House Visiting Company Information Pack May 2017

TECHNICAL SPECIFICATIONS

Tickets will be sold through our ABC account and all tickets are scannable on entry.

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Specifications

Technical Pack. Attenborough Arts Centre

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Technical Information

Stage. Get In & Parking

Technical Information

Technical requirements & conditions for hirers

Technical Specifications Nov 2016

IDEAL BAR. General information Technical specifications Production information

Technical Specifications

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

TECH SHEET AND INFORMATION (Updated )

Dr JOHN GALLAGHER CONCERT CHAMBER

Main House Technical Specification

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

Lighthouse Theatre Technical Specification

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Paramount Theatre Production Recap

The Haymarket Basingstoke Technical Specifications

Summary. Access and Parking

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

The Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

ROSE THEATRE MAIN THEATRE

Technical specifications Main theatre. Sound

Theatre Technical Specifications

Information for Incoming Companies

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Technical Specifications

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Arlington Arts Tech Spec 2018

Cornerstone Technical Specifications 2018 / V1

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Technical Specification

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

2017 TECHNICAL SPECIFICATIONS

The Lights Technical Guide June 2017

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Main House Technical Specifications

Technical Specifications

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specification Ardhowen Theatre

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

UNIVERSITY CONCERT HALL. Technical Specification

THE STREET THEATRE. Technical Specifications

BRAMALL INTRODUCING THE. Venue hire for classical & pop music, spoken word & comedy

RPAC REDLANDS PERFORMING ARTS CENTRE

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

COURTYARD!!!!! THEATRE

Little River Band Production Rider 2018

Theatre Technical Specifications

CENTRE FOR PERFORMING ARTS

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Sandusky State Theatre Technical Specifications

Meadow Brook Music Festival 3554 Walton Blvd Rochester Hills, MI Tech Pack

TOWER THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

TECHNICAL SPECIFICATION

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

7774 Sashabaw Road Clarkston, Michigan 48348

TECHNICAL SPECIFICATIONS

Technical Specifications

The Georgian Theatre Royal Technical Information For Visiting Companies

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Contents. 1. Contacts. 2. Directions & Transport Links 2.1. Address 2.2. Local Map & Directions 2.3. Public Transport

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Transcription:

Tech specs: Main Auditorium 900 (650 seated on ground floor, 250 on balcony) 1050 (800 standing on ground floor, 250 on balcony) Dimensions Pros Arch 20m x 5.6m high Pros Width 20m (Adjustable via tabs) Grid height 5.6m Stage width (inc. wings) 24m Stage depth from Pros 10m There is 1m of stage extending beyond house tabs, so total stage depth without tabs is 11m Prompt Corner S.R. Stage Floor 25mm WPB plywood, painted black Dressing Rooms (Under stage) Three rooms in total for all acts. Three with showers. Direct access by staircase to stage. Plus one green room and a long room both can be used as a production office. Wireless internet is available in the theatre and backstage.

Power Supply on Stage 1x 63A 3-phase Ceeform 2x 32A 3 phase Ceeform 1x 63A 3 phase Ceeform 3x 63A single-phase Ceeform 3x 32A single-phase Ceeform 2x 16A single-phase Ceeform SR & SL 2x twin 13A sockets SR & SL Parking & Other Facilities There is ample free car parking facilities around the theatre Adequate parking can be pre arranged for artists and crew (please pre-arrange) Bar Coffee Shop Sound Main PA JBL VRX900 Line Array 2x VRX918 Subs; 4x VRX 9032LA mid-high cabinets, Flown each side of stage Amps 2x Crown itech 6000 1x Crown itech 4000 Total main PA power 16kW Processor DBX Driverack4800 Configured L & R, front infills, balcony delays Foldback 6-way mix from FOH A side of stage monitor mix facility can be provided with advance notice given, at additional cost.

Control Yamaha LS932 Digital console. 32 lines from stage. 8 returns inc. L & R A further 12 sends and 12 returns are available if needed. Mics 8x Audix OM5 1x Audix drum mic kit comprising 1x D6 bass drum mic 1x i5 snare drum mic 1x D4 floor tom mic 2x D2 tom mic 3x ADX51 condenser mic We supply and endorse Audix mics, so most of the Audix range is available on request as an addition to the supplied mics at additional cost. 8x Passive DI boxes Selection of straight, boom and short boom mic stands Lighting Lighting grid is constructed of square section truss, 22m X10m, motorised. No. of circuits 48 FOH 15 Lantern Stock 18x 1kW Selecon Fresnel 20x 750w ETC Source Four 21-40 zoom profiles 8x 1kW PAR64 Parcans 6x Martin Mac250 Krypton moving head spots Dimmers 2x Zero88 Chilli Pro 24ch dimmers Control Zero88 Leapfrog 96 lighting console with touch-screen Follow-spots 2x 1.2kW Follow-spots, located at each side of balcony

Venue Facilities The following are incorporated in the rental of the theatre: Full box office and ticketing facilities Front of house management and ushering staff Full bar on the evening of the performance A highly trained and experienced staff to deliver expert technical support Use of all technical equipment as listed in the technical specifications of the theatre. All lighting and heating as normally used on the premises. Wireless internet is available in the theatre and backstage. Catering Tea/Coffee making facilities in green room Dressing room rider as per contract Day Rooms D- Hotel Tel: 0035341 9877700 Web: www.thedhotel.com City North Hotel Tel: 00353 1 690 6666 Web: www.citynorthhotel.com Merchandise 15% percent of take to thetlt There is no smoking inside the TLT. Please note there is a smoking area available outside the theatre or outside at the rear of the stage.

TIMES/ GENERAL INFO Suggested times Check with in-house rep for specific available times Get in 1pm Sound checks - As required but checks including support act to be finished by 6.30pm if possible. Doors 7.30pm (this depends on time of show) Support 8.00pm 8.30pm Headline 8.45pm to 9.00pm Curfew 10.45pm Requested Technical information We require the following information to be provided at time of booking Details of mix position Blog, picture and press release of event/artist Contract The following information must be available a week prior to the performance All relevant contact numbers Date and time of arrival/ get in Details of any extra crew/operators required for the get-in, show or get-out. Additional crew members are available subject to negotiation and possible additional fees. Details of any required pre-rigging of lamps or masking Cannot use pyrotechnical, as we have no fire curtain, can use haze but we need to know before hand Any additional hire requests Copy of your production risk assessment/ insurance The TLT Concert Hall & Theatre, East Coast Business Park, Matthews Lane, Drogheda Co. Louth Ireland Ph: +353 (0)41 9878560 Fax: +353 (0)41 6849906 info@thetlt.ie www.thetlt.ie Sat Nav:N53 41.970 W006 22.301 Vat no: 9709269C Company Registration Number: 466948