Universal DiSEqC controller USER MANUAL SAT CONTROL

Similar documents
Universal DiSEqC controller USER MANUAL

SATELLITE FINDER SK-3200 USER MANUAL

Satellite locator WS-6933

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

SAT IF distribution system

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

Horizon HD-STM. Combo Signal Analyzer TEST REPORT

DIGISAT MULTI USER MANUAL

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

Single cable multiswich programmer PC102W

HD-CM HORIZON DIGITAL CABLE METER

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

CMSDI G-SDI Matrix

V TV / SATELLITE DC Power Tester

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

SATFINDER 3 HD SLIM USER GUIDE

Satellite B or D. Satellite Inputs (LNB Trunk)

8dtek DSM Desired. Business Voucher Direct Contact to Sales Manager. TELE-satellite Magazine

SM-10 SAT Level Meter User s Manual

ZIG-POEPRO-70A. HDBaseT HDMI Extender

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

Instructions Manual

GWL/ Power Group Technology Solutions Stay Powered for the Future

CMLUX-4H4CAT. 4 by 4 HDMI V1.3 over CAT 6 Matrix with IR Return Control. Operation Manual CMLUX-4H4CAT

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

VLHDMIEXTFIB_2017V1.0

PRO-SDI44/84/124/164. 4x4/8x4/12x4/16x4 3G-SDI Matrix Switchers OPERATION MANUAL

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

KNX Dimmer RGBW - User Manual

Xsarius Satmeter Pro. Manual

HMX Analyser HDMI 3D Mini Analyser. Operating Manual. Part No TRIAX - your ultimate connection

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

Spectra Batten (Order code: LEDJ95)

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

NS-3 RF Noise Source Operation Manual

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER

ATLANTA ASF 2033HD+ DVB-S/S2 METER. User`s Manual

2x1 HDMI SWITCH. with Multiview and PIP Vanco Part Number: EVSW21MV

Galaxias. Flex LED display. User Manual

HDBaseT Extender Over Single Cat5e/6 cable

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

Satellite Signal Meter TEST REPORT 该独家报道由技术专家所作. 8dtek DSM Gifted. 30 TELE-satellite Global Digital TV Magazine 06-07/2011

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

CH-1605RXV 4K UHD+ HDMI over HDBaseT 2.0 Receiver (PD) with HDR/ARC

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

H25 DIRECTV Receiver. The New H25 IRD. Overview

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

ZIG-POC-100. HDBaseT HDMI Extender

SquareLED - Aura Bar & Matrix Beam Light 100

ARS x4 MATRIX SWITCHER Instruction Manual

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

User Manual POE. Twisted Pair POE Extender

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

SZU OPERATING INSTRUCTIONS SAT NAVI

Winmate Communication INC.

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

STM 17 HD. DVB-S2+T2/C Compact Meter. User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE.

Instructions for setting up Freesat V7HD or V8 Golden

Extender w/ RS-232 and 2-way IR

GEOSATpro GS120. DiSEqC 1.2 Motorized H-H H Motor

Zigen ZIG-ADM. 4K UHD+ Dolby Digital & DTS Stereo Decoder. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

HD-TM PLUS HORIZON DIGITAL TERRESTRIAL METER

User guide. Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers. Multiswitches

3G-SDI 4 by 4 Switcher

INSTALLATION MANUAL. 4. Chase all cables into the wall at the bottom of the TV to reduce chances of water reaching the TV.

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

Model: S-1071H(EFP) 7" EFP Field On-camera LCD Monitor. User Manual. Please read this User Manual throughout before using.

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

AtlonA 4x4 HDMI over CAT5 Matrix Switcher with IR Control AT-HD44M-SR. User Manual

Noise Detector ND-1 Operating Manual

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

Owner s Manual. Sat-Meter MSK 15. Order No.:

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

CH-507TX & RX HDMI over CAT5e/6/7 Transmitter and Receiver

User Manual. dcss/dscr Multiswitch 9732

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Zigen ZIG-PAX. Premium Digital / Analog Audio Extender. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

9" Portable On-camera LCD Monitor. User Manual. Model: DT-X91F HDSDI&HDMI, Waveform, Audio meter, Focus assist DT-X91H 3GSDI&HDMI DT-X91C HDMI

Evolution Digital HD Set-Top Box Important Safety Instructions

RF Solution for LED Display Screen

DisplayPort Extender over 2 LC Fibers

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

IMPORTANT SAFETY INSTRUCTIONS

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

XA-1. 3D Mini HDMI Analyser OPERATION MANUAL

User Guide. HDMI Fiber Optic Extender. DVI-7350a

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

Transcription:

USER MANUAL SAT CONTROL SAT CONTROL

Dear customer, If you have not been able to put the system into operation or have problems installing it, call the Technical Assistance phone as indicated on the first and the last pages, or write to us at support@sat-control.si. We will be pleased to provide you with further information. If you have installed the system to your satisfaction, we congratulate you. Your manufacturer. SAT CONTROL d.o.o. 1. INTRODUCTION Satellite television is one of most favourite and popular medium in today s world. But reception 36.000 km away from the sky is more technically difficult. Every user must have accurate setted dish with high-tech reception block and additionally complicated devices for pointing many satellites and splitting signal for more users. In the earlier years of satellite TV DiSEqC (Digital Satellite Equipment Control) protocol was invented due to commanding between master device and all slave peripheries. DiSEqC protocol uses 22 khz signal modulated with digital PWK (pulse wide keying) and like that it can be transmitted by the same coax cable like satellite signal and DC supply voltage. With these principe master device can command all other devices connected on the same cable in a multi-drop mode, real time. Every technician who work on development or service for satellite devices have a need for some measurement equipment with DiSEqC generating strings. And this need is introduced in this script like. Equipment is generator of DiSEqC strings as they are presented in original Eutelsat s document with additional manual entry and some special functions. Technical specifications: Manufacturer: SAT CONTROL d.o.o. Poženik 10, SI-4207 CERKLJE SLOVENIA Phone: +386 4 281 62 00, Fax: +386 4 281 62 12 www.sat-control.net, sales@sat-control.si All rights reserved. Copying is forbidden. The product is patented. Made in EU (Slovenia) 10 3

6.3. SPECIAL - This menu is NOT by DiSEqC specification. Its purpose is to setup polar-mount motors made by Sat- Control d.o.o. - It also uses PWK modulation on the same base frequency but string content is totally different, communication with motor is two-way and fully secured from data collision to achieve the best regularly transmittion. Menu allow user to get into motor s software and setup its settings and on-line check behaviour of the motor. That option is best way to control a motor and its working. Adjust 0 degrees_1 - Submenu can adjust motor scale of degrees by setting its zero degrees. If the motor is not accurate when you are pointing it with GotoX degrees, you must adjust it in this submenu. By moving number E or W and pressing enter, motor will do the move. Command for shift and command for goto zero degrees will be sent to the motor and motor will move to its new zero position. If new zero position equal to real zero, motor is adjusted. Otherwise repeat unless you get real zero degrees. - Note: for versions of motors without LED light emitting diode by F-connectors Adjust 0 degrees_2 - Submenu has the same purpose like upper submenu, but it works in two-way communications. When enter in this submenu, equipment will get current value of zero factor from the motor. Now you can change it as you want and press enter to send it in the motor. Motor will than move to its new zero position. If new zero position equal to real zero, motor is adjusted. Otherwise repeat unless you get real zero degrees. You can get current zero factor anytime you want by pressing 2nd function button. - Note: for versions of motors without LED light emitting diode by F-connectors Read eeprom - This command will read value from internal storage place. There motor have stored locations for all 50 satellites (used when you are driving motor by location and NOT used when you are using degree commanding). Eeprom also has stored some system parameters that can be checked (please refer to technical script of motor SM3D22). - Set wanted eeprom address and press enter. Motor will give you reply of current value of address. Write eeprom - In this submenu values stored in eeprom can be changed - Attention!!! Do not change values unless you know what you are doing. Changing values can cause inaccuracy of the motor (please refer to technical script of motor SM3D22). - Enter address of eeprom to be changed and press enter. Enter new value in HEX format and press enter again. New value is written. 3. GENERAL PRECAUTIONS o DiSEqC Controller is low-voltage device. Do not connect it to some high voltage. o Use checked cables for connections o For cleaning its housing use soft and not aggressive liquids. o Do not leave it on the sun or by any source of heat. o Do not expose to any moisture or rain. o Do not use it at low temperatures below 0 C or high temperatures above 50 C. o Strokes and shocks can damage the device. Avoid device from falling down to the hard floor. o It is not recommended to repair it by yourself. Contact your supplier if anything is wrong with the device. 4. CONNECTIONS ON UNIVERSAL DISEQC CONTROLLER 4.1. F-CONNECTORS - Upper side has two F-connectors for connecting equipment to DiSEqC measure device. Any sent DiSEqC string will go out on these two connectors. Also DiSEqC reply will be received here (if two-way DiSEqC communication is used). - Both F-connectors are shorted for signal and DC supply and are totally equal. One connector can be connected to i.e. motor, LNB, switcher and other can be used for purposes like signal meter, analysers... etc. 4.2. RS232 PORT Beside F-connector there is RS232 port for connection to PC. Any received DiSEqC string will be sent also to RS232 port and can be seen on any terminal program on PC. Use extension COM cable for connecting (DB9 Female DB9 Male, 2 2, 3 3, 5 5). Recommended program on PC is HyperTerminal (included in almost all Windows environments). Set configuration of program to: 8 5

2 11

2. TABLE OF CONTENTS 1. Introduction...3 2. Table of contents...4 3. General precautions...5 4. Connections on DiSEqC Controller...5 4.1. F-Connectors... 5 4.2. RS232 port...5 5. Charger plug...6 6. Structure of menu...6 6.1. Command...6 Goto degrees...6 Goto location...6 Store location...6 Stop motor...6 Drive east...7 Drive west...7 Switch commutative...7 Switch uncommutative...7 6.2. Manual...7 6.3. Special...8 Adjust 0 degrees_1...8 Adjust 0 degrees_2...8 Read eeprom...8 Write eeprom...8 Read ram...9 Set mode...9 7. Energy supply...9 8. Reception of DiSEqC string...9 Read ram - This option can read internal working ram values. If you don t know meaning of addresses this submenu is unusable for you (please refer to technical script of motor SM3D22). Set wanted ram address and press enter. Motor will give you reply of current value of address. Set mode - Motors from Sat-Control can work in different options. Setting its mode can change working of motor as described in table below. 7. ENERGY SUPPLY - Equipment has its own battery inside (Ni-Cd 12V, 600mAh). It is enough to drive satellite polar-mount motor for few hours non-stop. When battery is low, indicator will light red (can be adjusted with inside trimmer resistor). When external charger is connected, charger will charging battery disconnected from equipment, but equipment will be supplied by charger. - Battery will be charged with constant current of cca. 60mA that method is recommended for Ni-Cd battery. When charging, LED indicator will constantly lighting green and stop to light when charging is terminated. Termination method for charging is voltage level. When battery voltage will reach predefined voltage level, charging will be finished (termination voltage level can be adjusted with inside trimmer resistor). Aware that charging must not exceed 14 hours. 8. RECEPTION OF DISEQC STRING - is two-way DiSEqC device. It can send and receive DiSEqC strings. When use it as DiSEqC monitor, normally connect it with measure device i.e. satellite receiver and you will be able to see receiver s output strings on second line of LCD. Only thing to be noted here is output voltage of measured device must be as close as have it (that is 18V). All recepted string will be sent through RS232 COM port to PC for logging purpose. 4 9

5. CHARGER PLUG Use this plug to charge internal battery. See chapter Energy supply. Charger s voltage is around 17V. 6. STRUCTURE OF MENU 6.1. COMMAND - This menu contains the most useful DiSEqC commands for driving motor and signal switchers. For more detailed description of these commands please see Eutelsat s DiSEqC bus specification. Goto degrees - Send commands for driving polar-mount motor to wanted degrees. Motor will turn to relative angle. If you are pointing satellite, geometrical calculation according to your geo. position must be done. This submenu is suitable for GotoX, Usals controlling of motor. Goto location - Send commands for calling stored satellite location. Motor will move a dish to stored location that belongs to called number. Location is stored in motor. Store location - When satellite is pointed and signal is on maximum, with this command you can store location of dish to some location number. Note: receiver should call that number to get stored satellite (controlling motor by location). Stop motor - Send command for unconditional stop. Drive east - Command will move a polar-mount motor to east direction for defined number of impulses. What angle it will be, it depends on resolution of the motor. Drive west - Command will move a polar-mount motor to west direction for defined number of impulses. What angle will that be it depends on resolution of the motor. Switch commutative - Send commands for DiSEqC 1.0 switchers. Signal switcher will switch HF connection to the selected input. Usually this type supports maximum four inputs. - Note: Default frame byte is 0xE0 and address byte is 0x10 for switchers as refer in original DiSEqC Switch uncommutative - Send commands for DiSEqC 1.1 switchers. Function is the same like in commutative switchers, but number of inputs is extended to max. 16 (some application have 32 in combination with commands from Switch commutative menu). - Note: Default frame byte is 0xE0 and address byte is 0x10 for switchers as refer in original DiSEqC 6.2. MANUAL - This menu is suitable for manual entry of DiSEqC command. You can put into line any bytes you want; the only restriction is that number of bytes must be greater than 3 bytes and smaller than 7 bytes. Also half of byte is not allowed. Than entered string will be send. Device will not check if string is in DiSEqC specification or not. - Press button to clear display. 6 7