Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Similar documents
VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Visy Theatre technical information and general specifications 2019

Powerhouse Theatre technical information and general specifications 2017

2017 TECHNICAL SPECIFICATIONS

DEREHAM MEMORIAL HALL

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Theatre Technical Specifications

CENTRE FOR PERFORMING ARTS

Matt Dann Cultural Centre

Queensland Performing Arts Centre

Main House Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Dr JOHN GALLAGHER CONCERT CHAMBER

The Haymarket Basingstoke Technical Specifications

Main House Technical Specification

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

TECHNICAL SPECIFICATIONS

New Theatre Royal Lincoln Technical Information

Technical Data Sheet

CHELSEA THEATRE. Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

THE STREET THEATRE. Technical Specifications

Technical Specification Pavilion Dance

Technical Specifications

Latrobe Performing Arts Centre

Technical Specifications. Taylor Little Theater

BECKETT THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

ROSE THEATRE BASEMENT

RPAC REDLANDS PERFORMING ARTS CENTRE

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

JERWOOD VANBRUGH THEATRE

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Auditorium: 16m x 24m (including stage area) Variable acoustics to suit different performance types

Technical Specification

The Mannie Manim Technical Specifications

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

YOUR TOOLKIT TO AMPLIFY YOUR SHOW

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Technical Specifications

Stage. Get In & Parking

Hopgood Theatre NOARLUNGA CENTRE

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

John Leslie Theatre. Technical Specifications. Updated July 2018

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

TOWER THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

Technical Specification

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Lighthouse Theatre Technical Specification

Technical Specifications Updated 01/10/2017. Stage

HIRE AND TECHNICAL INFORMATION

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Sandusky State Theatre Technical Specifications

Monash Academy of Performing Arts

Monash University Academy of Performing Arts

MONASH University Academy of Performing Arts

TECHNICAL SPECIFICATIONS

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

ISLAND HALL TECHNICAL INFORMATION

Darlington Hippodrome Technical Specification

Barney Simon Theatre Technical Specifications

Theatre Technical Specifications

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

Technical specifications Main theatre. Sound

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Marjorie S. Deane Little Theater

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Theatre Technical Specification

INFORMATION FOR VISITING COMPANIES

Technical Director of Production Andrew Quick Ext 252

TECHNICAL PACKAGE.

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specifications

Arcadia Performing Arts Center Technical Specifications and Information

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

The ACT Facility Technical Specifications Main Stage Information

Technical Specifications and Inventory Spring 2018

Technical Specification

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

DUNSTAN PLAYHOUSE TECHNICAL SPECIFICATIONS

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Pack. Attenborough Arts Centre

332 fixed seats (max capacity) with reserved space for disable access

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Downtown Arts Center Tech Packet. General Information

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Access to back stage is off Fletcher St on the eastern side of the building

Yan Yean Theatre Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Specification. Updated: April 2016

Transcription:

Auditorium Seating The Visy Theatre is a versatile venue with many configurations. The standard venue hire includes the venue in standard mode with a capacity of 200. The table and diagram below detail the different configurations possible for the venue. Any changes from standard mode will incur a cost of labour to complete the necessary changes. STAGE CONFIGURATIONS Permanent Seating (stalls) 112 Pit Seating 34 Removable Side Seats 54 Total Capacity 200 Configuration Seating sections Capacity Standard mode (1-5) 200 Permanent seating (1) 112 Stalls and 1 side bank on stage left and right Stalls with 2 side banks on left and right (1+3a+3b) 130 (1+3a+3b+4a+4b) 148 Configuration Seating sections Capacity Cabaret mode with 148 theatre seats, plus 10 x 700mm tables with 40 chairs (1+3a+3b +4a+4b) 188 Using the numbers listed in the seating sections column, refer to the diagram below to decide on the configuration that is best suited to your event. For further detail contact Brisbane Powerhouse. Stalls with 3 side banks on left and right (1+3a+3b+4a+4b+5a +5b) 166 Stalls with 1 side bank on stage left and 1 side bank on stage right and centre of pit seating (1+2+3a+3b) 144 Stalls with 2 side banks on stage left and 2 side banks on stage right and centre of pit seating Stalls with 3 side banks on stage left and 3 side banks on stage right and centre of pit seating Stalls with centre of pit seating (1+2+3a+3b+4a+4b) 162 (1+2+3a+3b+4a+4b) 180 (1 + 2) 126 Venue drawings are available as PDF files on the website, and CAD files are available on request. Stalls with 3 side banks on stage left and 3 side banks on stage right and centre of pit seating (1+2+3a+3b+4a+4b+ 5a+5b) 180 Page 1 of 7

Staging Brisbane Powerhouse has a limited supply of staging, rigging and height safety equipment available. Height safety equipment required in each venue is provided as part of the venue hire. Additional rigging equipment is available for hire. Please note all rigging must be installed by a licensed rigger. Brisbane Powerhouse can provide a licensed rigger for a fee if required. Additional staging equipment, including soft blacks, rostra and treads are also available for hire. Please contact Brisbane Powerhouse for the complete list of equipment. RIGGING Fixed grid of 48mm heavy wall steel scaffold pipe Grid height is 4.8m to the underside of the pipe 60kg per meter distributed load 280kg point load at a concrete insert 3 rigging points (one double, one single) suitable for circus rigging, please contact Brisbane Powerhouse for rating. STAGE FLOOR The stage is a sprung timber dance floor. The top deck is Masonite, Painted black Dulux low sheen acrylic. The floor has a 750kg per square meter distributed load. DIMENSIONS Stage size when sunken pit seating is open Stage edge to upstage columns 7.12m Stage edge to rear wall 16.07m Stage left to stage right 7.66m Stage size when sunken pit seating is closed Stage edge to upstage columns 8.25m Stage edge to rear wall 17.20m Stage left to Stage right 10m Stage size when sunken pit seating is closed and side banks removed Stage edge to upstage columns 8.25mm Stage edge to rear wall 17.12 Stage left to stage right 12m DRAPES The venue comes supplied with 6 x gathered blacks 1.6m wide x 3.3m high 2 x tabs, 6.0m x 3.2m each for rear stage masking 4 x tabs, 6.0m x 2.1m each for onstage masking Page 2 of 7

.Lighting The lighting grid is a fixed grid with a height to the underside of the pipe of 4.8m. For point loads and rigging information please refer to the rigging section. The theatre comes with a basic lighting rig patched and focused as part of the hire. Additional lights from the stock can be added as required. 144 Lighting patch points are distributed throughout the venue and terminate in a backstage patch/dimmer room fitted with 144 dimmers. The dimmers are patched 1-1. Additional lighting equipment is available for hire, please contact Brisbane Powerhouse for a complete list. LIGHTING FIXTURES 35 x ETC 575w Source Four jr 25/50 profile 20 x Selecon 1.2k Fresnel 9 x Selecon Rama 1.2k Fresnel 10 x ETC 575w Source Four pars 18 x 110v Par 64 WFL with series splitters 8 x LED par 64 18 RGBW with barn doors 4 x Selecon 500w 3 cell cyc battens 1 Unique Hazer ACCESSORIES 10 x Irises for ETC Source Four juniors 10 x M size gobo holders LIGHTING CONTROL 6 x HPC 12 6 x HP 12 1 x ETC Ion 2000 with fader wing and radio focus remote 2 universes of DMX are distributed to the grid (Universe 2) and dimmer room (Universe 1) via a LSC ISO system House lights are controlled via a Dynalite System. DMX control of houselights is available if required. Power Brisbane Powerhouse works on a distributed dual earth power system. The audio system operates on a true online UPS to condition the power and is on a separate earth to main power distribution. All audio points are red in colour. 40 amp 3 phase outlets are distributed around the venue and in the dimmer room. As part of the venue hire a limited supply of 240v leads are supplied. Additional 3 phase leads and weiland cables are available for hire. 8 x 40 amp 3 phase outlets in dimmer room 2 x 40 amp 3 phase outlets in rear stage, one stage left and one stage right Page 3 of 7

1 x 40 amp audio 3 phase located in bio box All audio power is run on a separate earth and is filtered by a UPS Sound The Visy Theatre comes supplied with a full front of house audio system including console, playback and a small amount of foldback. There is patching available around the stage, and extra drop boxes can be supplied as necessary. A limited supply of stands, leads and adaptors are available as part of venue hire. FOH CONTROL DiGiCo SD11 console 1 x dual channel XTA 31 band EQ for front of house 2 x Tascam CD01u CD player CABINETS 4 x Meyer UPJ 1p speakers in the roof provide front and middle L&R 2 x Meyer UPA-1p speakers rear left and right 2 x Meyer USW 1p sub-woofer under seating. Speakers can be run as L\R or patched individually FOLD BACK 2 x martin audio LE12 JB high powered fold back wedges 1 x QCS dual channel amplifiers 2 x Yamaha P2500S 4 x EV SX-300 MICROPHONES/DI A range of vocal and instrument mics, and DI s are available on request, with BPH holding a selection of high quality microphones of Neuman, Audio Technica, Rode and Miktek plus the standard range of Shures and Beyers. DI s include a modest stock of Radial, BSS and LA Audio. Audio Visual Not included in the standard venue hire but available for an additional hire cost is the following AV equipment: Sanyo 6K PLC-RM150L projectors 16 x 9 HD220 screen (16:9 ratio, both front and rear projection available) 12 x 7.5 HD150 screen (16:9 ratio, both front and rear projection available) Switchers, transmitters and associated equipment Please discuss any AV requirements with the Brisbane Powerhouse Production department. Pianos Brisbane Powerhouse has the following pianos available for hire: 1 x Yamaha 52 key Upright piano Page 4 of 7

1 x 5 1 Boston 52 key Baby Grand piano Page 5 of 7

Stage Management System The Stage Management System within the theatre comprises of a Stage Manager s Desk (SMD) which can be located in the control room or either back stage left or right. The system has full paging and relay to the dressing rooms (1-4) attached to the Visy Theatre. As part of venue hire talk back is provided at the SMD, sound desk and lighting desk as well as one additional set for back stage. Additional talk back is available for hire if required. Stage Manager s Desk Inbuilt cue light system Paging to dressing rooms attached to the theatre Stage camera (1080P) located on centre of grid bar 1 Stage monitor located in Prompt Corner Stage relay to SMD and dressing rooms Clear-com talk back base station with Beyer headsets 3 additional belt packs and Beyer headsets Miscellaneous Fire Evacuation and Work Place Health and Safety Induction All visiting clients, including crew and cast, must undergo a venue specific induction regarding fire evacuation and workplace health and safety. A copy of the Brisbane Powerhouse fire evacuation procedure is available on request. It is a requirement of Brisbane Powerhouse Work Place Health and Safety that closed-in shoes are worn on stage for all site inspections, bump in and bump outs. Smoking Policy The Brisbane Powerhouse is a non-smoking venue. Persons who smoke are required by law to smoke only in Designated Smoking Areas. Risk Assessment Shows which are deemed to contain an item or event that may cause a potential hazard may be required to complete a risk assessment in consultation with Brisbane Powerhouse. Insurance Details of insurance provided with venue contract. Assistive Listening System The venue is equipped with an UHF assistive hearing system for patrons. Head sets are collected by patrons as needed from box office. Page 6 of 7

Loading Access Brisbane Powerhouse has two loading dock facilities. For rear loading trucks and vehicles, the lower loading dock is accessible from the car park and provides access to the Powerhouse Theatre via a lift from the ground floor. Please see below for access dimensions. The upper loading dock, accessible by prior arrangement with Brisbane Powerhouse, provides direct stage access to the Powerhouse Theatre for rear loading trucks and vehicles. The upper loading dock can accommodate a 40 semi-trailer. Due to the complexities of transporting freight from the upper loading dock to the Visy Theatre, using this dock is not advised. A forklift is available via prior arrangement with Brisbane Powerhouse for side loading trucks. Please see below for dimensions. Lower Loading Dock: Door clearance: 2.7m x 3.5m (W x H) Vehicle clearance height: 3.7m Corridor clearance: 1.76 x 2.73 (W x H) Loading height: Ground Upper Loading Dock: Door width: 3.2m Height clearance: 5.5m Loading height: 0.7 2.0m Table lift capacity: 2000kg Lift to Stage Level: Door width: 1.3m Door height: 2.0m Internal (mm): 1500 x 2300 x 2170 (W x D x H) Capacity: 1700 Kg Page 7 of 7