Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Similar documents
Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

Minicontactorrelay,2NO/2NC,DCoperated

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Series CT7N Bimetallic Overload Relays

AS09..S 3-pole Contactors - Spring Terminals

Datasheet - SRB-E-201ST

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Datasheet - SRB301LC 24VAC/DC

Bulletin 190 IEC Modular Starter System

A V 50Hz / V 60Hz

High performance circuit breakers

Ordering details. Approval. Classification

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Circuit breakers BZM. Circuit breakers BZM

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

02/11/2015

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Modular pulse operated latching relay 16 A

GV2ME. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

TeSys circuit-breakers

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

GV2P05. Main. Device short name. Device application

llen-bradley 194R-HM4-NFPA3

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

DMX and 4000 air circuit breakers from 800 to 4000 A

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

GV2ME. Main. Device short name. Device application

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LED control gear Compact fixed output

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

Magnetic and Hydraulic-Magnetic Circuit Breaker

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Power Circuit of a UL508A Panel. Typical UL489 Application

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LED Driver Linear / area fixed output

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Circuit-Breakers for Motor Protection Series 8523/8

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

KRF EMC Filters Installation, Operation and Maintenance Manual

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Features XT SC 012 B B A

GR circuit breaker - hydraulic magnetic, Datasheet

16 A and 25 A power contactors with or without handle

15 Series - Dimmer

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Magnecraft Power Relays

Manual Motor Starter Specifcations

LED MODULES READYLINE DL

Features XT SC 012 B B A

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Capacitors and banks 50 Hz 0 400/415 V network voltage

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

SURGE PROTECTIVE DEVICES

Assembly. Front view. LEDs. Parametrization interface. Power Bus


GR circuit breaker - hydraulic magnetic, Datasheet

Generator protection relay

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Kuhnke Technical Data. Contact Details

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

3AH3 Vacuum Circuit-Breakers

EMC Solutions Noise filtering

Transcription:

DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type Fixed Release system Electronic release Construction size NZM3 Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory Number of poles 4 pole Standard equipment Screw connection Switching capacity 400/415 V 50 Hz I cu ka 50 Rated current = rated uninterrupted current Rated current = rated uninterrupted current I n = I u A 400 Neutral conductor Setting range Overload trip % of phase conductor CSA 100 I r A 200-400 Main pole I r A 200-400 Short-circuit releases Non-delayed I i = I n x 2-11 Technical data General Standards IEC/EN 60947 Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Ambient temperature, storage C - -40 - + 70 Operation C -25 - +70 Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 Safe isolation to EN 61140 g 20 (half-sinusoidal shock 20 ms) Between auxiliary contacts and main contacts V AC 500 between the auxiliary contacts V AC 300 Weight kg 8.4 Mounting position Vertical and 90 in all directions 12/28/2018 Eaton 265891 ED2018 V51.0 EN 1 / 10

With XFI earth-fault release: - NZM1, N1, NZM2, N2: vertical and 90 in all directions with plug-in unit - NZM1, N1, NZM2, N2: vertical, 90 right/left with withdrawable unit: - NZM3, N3: vertical, 90 right/left - NZM4, N4: vertical with remote operator: - NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90 in all directions Direction of incoming supply as required Degree of protection Device In the operating controls area: IP20 (basic degree of protection) Enclosures With insulating surround: IP40 With door coupling rotary handle: IP66 Terminations Tunnel terminal: IP10 Phase isolator and strip terminal: IP00 Other technical data (sheet catalogue) Temperature dependency, Derating Circuit-breakers Rated current = rated uninterrupted current I n = I u A 400 Rated surge voltage invariability U imp Main contacts V 8000 Auxiliary contacts V 6000 Rated operational voltage U e V AC 690 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 1000 Use in unearthed supply systems V 690 Switching capacity Rated short-circuit making capacity I cm 240 V I cm ka 187 400/415 V I cm ka 105 440 V 50/60 Hz I cm ka 74 525 V 50/60 Hz I cm ka 53 690 V 50/60 H Ic ka 40 Rated short-circuit breaking capacity I cn I cn Icu to IEC/EN 60947 test cycle O-t-CO Icu ka 240 V 50/60 Hz I cu ka 85 400/415 V 50/60 Hz I cu ka 50 440 V 50/60 Hz I cu ka 35 525 V 50/60 Hz I cu ka 25 690 V 50/60 Hz I cu ka 20 Ics to IEC/EN 60947 test cycle O-t-CO-t-CO Ics ka 240 V 50/60 Hz I cs ka 85 400/415 V 50/60 Hz I cs ka 50 440 V 50/60 Hz I cs ka 35 525 V 50/60 Hz I cs ka 13 690 V 50/60 Hz I cs ka 5 Rated short-time withstand current t = 0.3 s I cw ka 3.3 t = 1 s I cw ka 3.3 Utilization category to IEC/EN 60947-2 A Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) Operations 15000 Lifespan, electrical AC-1 400 V 50/60 Hz Operations 5000 Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker. 12/28/2018 Eaton 265891 ED2018 V51.0 EN 2 / 10

AC--3 415 V 50/60 Hz Operations 5000 690 V 50/60 Hz Operations 3000 400 V 50/60 Hz Operations 2000 415 V 50/60 Hz Operations 2000 690 V 50/60 Hz Operations 2000 Max. operating frequency Ops/h 60 Total downtime in a short-circuit ms < 10 Terminal capacity Standard equipment Screw connection Optional accessories Box terminal Tunnel terminal connection on rear Round copper conductor Box terminal Solid mm 2 2 x 16 Stranded 2 mm 1 x (35-240) 2 x (25-120) Tunnel terminal Solid mm 2 1 x 16 Stranded 1-hole 2 mm 1 x (16-185) Double hole fitting 2 mm 2 x (50-240) Bolt terminal and rear-side connection Direct on the switch Solid mm 2 1 x 16 2 x 16 Stranded 2 mm 1 x (25-240) 2 x (25-240) Connection width extension mm 2 Al circular conductor Connection width extension mm 2 2 x 300 Tunnel terminal Solid mm 2 1 x 16 Stranded Stranded mm 2 1 x (25-185) 2) Double hole 2 mm 1 x (50-240) 2 x (50-240) Bolt terminal and rear-side connection Direct on the switch Solid mm 2 1 x 16 2 x (10-16) Stranded 2 mm 1 x (25-120) 2 x (25-120) Cu strip (number of segments x width x segment thickness) Box terminal Bolt terminal and rear-side connection min. mm 6 x 16 x 0.8 max. mm 10 x 24 x 1.0 + 5 x 24 x 1.0 (2 x) 8 x 24 x 1.0 Flat copper strip, with holes min. mm 6 x 16 x 0.8 Flat copper strip, with holes max. mm 10 x 32 x 1.0 + 5 x 32 x 1.0 Connection width extension mm (2 x) 10 x 50 x 1.0 Copper busbar (width x thickness) mm Bolt terminal and rear-side connection Screw connection M10 2) Up to 240 mm² can be connected depending on the cable manufacturer. 12/28/2018 Eaton 265891 ED2018 V51.0 EN 3 / 10

Direct on the switch min. mm 20 x 5 max. mm 30 x 10 + 30 x 5 Connection width extension mm Control cables Connection width extension max. mm 2 x (10 x 50) 2 mm 1 x (0.75-2.5) 2 x (0.75-1.5) Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 400 Equipment heat dissipation, current-dependent P vid W 72 Operating ambient temperature min. C -25 Operating ambient temperature max. C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 7.0 Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kv) / Circuit breaker for power transformer, generator and system protection (ecl@ss10.0.1-27-37-04-09 [AJZ716013]) Rated permanent current Iu A 400 Rated voltage V 690-690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz ka 50 Overload release current setting A 200-400 Adjustment range short-term delayed short-circuit release A 0-0 Adjustment range undelayed short-circuit release A 800-4400 Integrated earth fault protection No Type of electrical connection of main circuit Screw connection 12/28/2018 Eaton 265891 ED2018 V51.0 EN 4 / 10

Device construction Built-in device fixed built-in technique Suitable for DIN rail (top hat rail) mounting No DIN rail (top hat rail) mounting optional No Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 With switched-off indicator No With under voltage release No Number of poles 4 Position of connection for main current circuit Front side Type of control element Rocker lever Complete device with protection unit Yes Motor drive integrated No Motor drive optional Yes Degree of protection (IP) IP20 12/28/2018 Eaton 265891 ED2018 V51.0 EN 5 / 10

Characteristics 12/28/2018 Eaton 265891 ED2018 V51.0 EN 6 / 10

Let-through current 12/28/2018 Eaton 265891 ED2018 V51.0 EN 7 / 10

Let-through energy 12/28/2018 Eaton 265891 ED2018 V51.0 EN 8 / 10

Dimensions 1 Blow out area, minimum clearance to adjacent parts 2 Minimum clearance to adjacent parts 12/28/2018 Eaton 265891 ED2018 V51.0 EN 9 / 10

Additional product information (links) IL01208009Z (AWA1230-1992) Circuit-Breaker, basic unit IL01208009Z (AWA1230-1992) Circuit-Breaker, basic unit Temperature dependency, Derating CurveSelect characteristics program additional technical information for NZM power switch ftp://ftp.moeller.net/documentation/awa_instructions/il01208009z2017_01.pdf http://ecat.moeller.net/flip-cat/?edition=hplen&startpage=17.172 http://www.eaton.eu/de/europe/electrical/customersupport/configurationtools/characteristicsprogram/index.htm ftp://ftp.moeller.net/documentation/pdf/nzm_technic_de_en.pdf 12/28/2018 Eaton Industries GmbH http://www.eaton.eu 12/2018 by Eaton Industries GmbH Eaton 265891 ED2018 V51.0 EN 10 / 10