3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

Similar documents
3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3M Cold Shrink Foldback Splice Jacket Kit

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

Instructions. Cable with Armor F CAUTION. October Rev A

3M Cold Shrink Rubber Splicing Kit 5552

Cold Shrink Silicone Rubber Termination QT-II

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

Industrial Loadbreak Elbow

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Sensored Termination (15 kv) QX-T15I-vi1-E

HSK Mine and Portable Cable Splice

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

3M Better Buried Compound Compression Closure System

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

3M Better Buried Closures

Cold Shrink Straight Joint

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

3 SLiC Aerial Closure with Rubber End Seal

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

SLiC Fiber Aerial Closure System

Scotch Heavy Duty Vinyl Electrical Tape 22

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Distribution Box (DDB)

Solutions for Electronic Specialty Markets (ESM)

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M Locator Plate N

3M Super 23 Electrical Tape

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

27mm ECAM Double Cable Entry Port

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

Built tough for long-term connections

Built tough for long-term connections

2178-L/S Series Fiber Optic Splice Case with Gasket

Scotchlok Connectors and Tools

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

K & B Flame Retardant Building Riser Closures

Aging test: integrated vs. non-integrated splices shield continuity systems.

3M No Polish Jacketed SC/APC Connector

3M 8900 Single-mode SC Crimplok Connector

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Cabinet Tools and Accessories Ordering Guide

3 Cold Shrink Products

18mm ECAM Cable Entry Port

3M No Polish Jacketed SC/APC Connector

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

SLiC Fiber Aerial Closure 533 and 733

3M Slim Lock Closures

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

3M Mini D Ribbon (MDR) Cable Assembly

Instruction Guide February 2017

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

3M Fiber Closures BPEO

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Closure System LL

Dynatel Advanced Cable Locator 2250

Rotor Blade Protection Kit 8999K11

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

FOSC 450 C6 and D6 Closures

Coaxial Cable Feedline Choke Kit - 50 Ω

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

3M We are Projectors! When the show must go on, 3M makes it easy:

LEGEND POWER SYSTEMS

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

Low Voltage Splices, 1000 V or less

VITALink Taped Splice Straight Through Crimp

3M MetPak 2-FB Header

4320 SS-25 Self-Strip Terminating Block

Instructions for Use of Overlap Seam Repair Kit:

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

Student Services & Classroom Addition

3M High-Speed Solutions

3M New Construction Cross-Connect Cabinets. The. Commitment. Your Copper Requires

2178 L/S Series Fiber Optic Splice Cases and Accessories

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

PYROTENAX TERMINATION KITS COMMERCIAL WIRING. For Pyrotenax copper sheathed mineral insulated (MI) wiring cable

MOTOR LEAD TO DOWN HOLE CABLE SPLICE PROCEDURE

Transcription:

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS-350-1000 for Tape Shield, Wire Shield, UniShield, and Longitudinally Corrugated (LC) Cable Instructions IEEE Std. 404 35 kv Class 250 kv BIL F CAUTION Working around energized systems may cause serious injury or death. Installation should be performed by personnel familiar with good safety practice in handling electrical equipment. De-energize and ground all electrical systems before installing product. Kit Selection Table Kit Number Cable Insulation O.D. Range Min. Cable Jacket O.D. Conductor Size Range QS4-35TS-350-1000 1.24" - 2.07" (31,5-52,6 mm) 1.78" (45,2 mm) 350-1000 kcmil* (185-500 mm 2 ) * Splices (including size transitions) can be made to smaller or larger conductors (but larger conductors may require special neutral handling), provided both cables are within the Insulation O.D. Range and the connector meets the dimensional requirements shown below. Connector Dimensional Requirements Minimum Inches (mm) Maximum Inches (mm) Outside Diameter 0.87" (22,1 mm) 2.07" (52,6 mm) Length Aluminum (Al/Cu) Compression Length Copper (Cu) Compression and 3M Shearbolt Connectors QCI 350-750 and QCI 500-1000 7.50" (191 mm) 8.25" (210 mm) July 2016 3 78-8127-8892-1 Rev B

1.0 Kit Contents a. 3M Cold Shrink QS4 Integrated Splice Body QS4-35TS-350-1000 (1 ea.) b. Constant Force Springs (5 ea.) c. 3M Red Compound P55/R Tubes (non-silicone grease) (2 ea.) d. Scotch Rubber Mastic Tape 2228 Rolls, 2" x 36" (2 ea.) e. Scotch Mastic Strips 2230, 6" length (6 ea.) f. Cold Shrink Adapter Tube (1 ea.) g. 3M EMI Copper Foil Shielding Tape 1181 Strips, 1/2" x 10" (2 ea.) h. Ground Strap (1 ea.) i. 3M Cable Cleaning Pads CC-3 (1 ea.) j. Cut-back Templates (2 ea.) k. Wire Brush (1 ea.) l. Instruction Booklet (1 ea.) Cold Shrink adapter tube may not be included in all kits. Kits contain either 1 or 2 cut-back templates as needed per conductor size. Do not use knives to open plastic bags. Connector not shown, but if included, it is indicated on the packaging label. 2 78-8127-8892-1 Rev B

2.0 Prepare Cables 2.1 Check to be sure the cable fits within the kit ranges as shown on the cover page. 2.2 Prepare cables according to standard procedures. Refer to template provided or illustration below for proper dimensions (Figure 1). Tape & LC Shielded Cables [ A ] 3 1/2" (89 mm) 3" (76 mm) [ B ] Cable Jacket Metallic Shield Semi-con Insulation Wire Shielded Cable [ A ] 3 1/2" (89 mm) 3" (76 mm) [ B ] Cable Jacket Wire Shield Semi-con Insulation UniShield Cable [ A ] 3 1/2" (89 mm) 3" (76 mm) [ B ] Shield Wires Insulation Typical Conductor Size* kcmil (mm 2 ) 350**-500 (185-300) 750-1000** (325-500) Insulation OD Range Inches (mm) 1.24-1.70 (31,5-43,2) 1.59-2.07 (40,4-52,6) Jacket Cutback "A" Inches (mm) 15 3/4 (400 mm) 15 1/4 (387 mm) Semi-con Cutback "B" Inches (mm) 9 1/4 (235 mm) 8 3/4 (222 mm) *For 100% and 133% insulation levels, Insulation OD is the final determining factor. **Cables must be within the Insulation OD Range of the splice kit and the connector must meet the dimensional requirements shown on the front page. Figure 1 78-8127-8892-1 Rev B 3

2.3 Secure end of each metallic shield or wires with a copper tape strip (Figure 2). Tape & LC Shielded Cables Cable Jacket Metallic Shield Foil Tape Semi-con Insulation Wire Shielded Cable Cable Jacket Wire Shield Semi-con Insulation Foil Tape Foil Tape UniShield Cable Shield Wires Insulation Figure 2 2.4 Clean or cover cable jacket 30" (760 mm) from jacket edge on side where splice body will be parked. 2.5 Slide integrated splice body onto clean cable jacket (Figure 3). Loose core end Integrated splice body Cleaned cable jacket Figure 3 4 78-8127-8892-1 Rev B

3.0 Install Connector If using a crimp-type connector, go to step (3.3). 3.1 If using a 3M Shearbolt Connector QCI 350-750 or QCI 500-1000, refer to the instructions included with the connector for insulation cut-back dimension. Insulation removal length shall not exceed 3 3/4" (95 mm) from conductor end (Figure 4). Refer to connector instructions for dimensions Figure 4 3.2 Install 3M Shearbolt Connector QCI 350-750 or QCI 500-1000 according to the instructions included with the connector (Figure 5). Shearbolt Connector Go to section 4.0 Install Splice. Figure 5 78-8127-8892-1 Rev B 5

3.3 If using a crimp type connector, remove cable insulation for 1/2 connector length plus an allowance* for increases in connector length due to crimping. Insulation removal length shall not exceed 4 1/8" (105 mm) from conductor end. Do not install connector now (Figure 6). * This assumes that the installer has determined the increased length of an aluminum connector crimped with a specific tool and die. Aluminum (Al/Cu) Crimp Connector Growth Chart Conductor Size 350-500 kcmil 1/4" (6 mm) 750-1000 kcmil 3/8" (10 mm) Typical growth allowance (per end) 1) Copper connectors do not require a length change allowance. 2) Maximum aluminum connector crimped length allowed is 8.25" (210 mm). One-half connector length + growth allowance* Figure 6 3.4 For 350 through 1000 kcmil copper connectors, 350 through 750 kcmil aluminium connectors or connectors with an O.D. between 0.87-1.60" (22,1-40,6 mm): Park the cold shrink adapter tube on the insulation. (Figure 7) Cold shrink adapter tube Figure 7 6 78-8127-8892-1 Rev B

3.5 Install connector. See table (on cover) for proper connector dimensions. (For standard 3M Connectors, refer to table at the end of this instruction for crimping information). If using an aluminum conductor, wire brush aluminum strands and then insert into connector. Remove excess inhibitor compound and remove conductor from connector. Wire brush aluminum strands again. Insert into connector and crimp. Remove any excess oxidation inhibitor from connector ends (Figures 8 and 9). File sharp connector flashing, if necessary, taking care to remove all metal filings from splice area. Antioxidant Compound Figure 8 Connector 4.0 Install Splice Figure 9 4.1 Apply a tape marker to semi-con insulation shield on cable which does not contain splice. Measure 11 1/4" (286 mm) from center of connector (Figure 10). 11 1/4" (286 mm) Tape Marker Semi-con Figure 10 78-8127-8892-1 Rev B 7

4.2 If using cold shrink adapter tube: Position adapter tube over the connector. Shrink adapter near the center of connector by pulling and unwinding the loose core end in a counterclockwise direction (Figure 11). Cold shrink adapter tube 4.3 Clean cables using standard practice: Figure 11 a. Do not allow solvent or abrasive to contact the cable semi-conductive insulation shield. b. Do not reduce cable insulation diameter below 1.24" (31,5 mm) specified for the splice. c. The insulation surface must be round, smooth and free of cuts/voids. Sanding may be necessary, finish sanding should be done with a 120 grit or higher electrical grade abrasive. d. Make certain that the cable insulation is smooth, clean and dry before continuing. 4.4 Apply 3M Red Compound P55/R on cable insulations, making certain to fill in edge of cable semi-con. Do not use silicone grease (Figure 12). Fill semi-con step Fill semi-con step Apply 3M Red Compound P55/R Apply 3M Red Compound P55/R Figure 12 8 78-8127-8892-1 Rev B

This core installs differently than other cold shrink products. 4.5 Position the splice body over connector area, aligning end of the splice body (not the core) at the center of the tape marker. Slowly start to remove the splice core by pulling and unwinding the loose core end counterclockwise, allowing only ¼" (6 mm) of the splice to shrink onto the tape marker. Carefully slide the splice body off the tape marker by pulling and twisting until the entire tape marker is exposed. Continue removing the core to complete the splice body installation (Figure 13). The splice body ends must overlap onto the semi-con of each cable by at least 1/2" (13 mm). Do not push the splice body toward the tape marker as this may cause the end to roll under. If the end does roll under, DO NOT use sharp-edged tools to pull it out as this could cut and damage the splice. Unwind Counterclockwise Align splice body with tape marker Figure 13 5.0 Connect Shielding 5.1 Remove the vinyl tape holding the shield sleeve on the rejacketing tube, and spread the shield sleeve out toward the cable jacket. 5.2 Hand-tighten the shield sleeve outward and secure it to the wires, tape or LC shields on either side of the splice using two constant force springs on each end between the jacket edge and the copper foil tape as shown (Figure 14). If using a ground strap for external grounding, leave room for a third constant force spring over the shield sock at the jacket end. Refer to Step (6.1). 78-8127-8892-1 Rev B 9

5.3 If shield sleeve extends beyond jacket edge, it may be interwoven with the constant force springs. Cinch (tighten) the spring after wrapping the final winding (Figure 14). Rejacketing Tube Foil Tape beneath Shield Sleeve Cable Jacket Constant Force Springs Figure 14 5.4 Wrap two half-lapped layers of vinyl tape over all constant force springs (Figure 15). Vinyl Tape Figure 15 10 78-8127-8892-1 Rev B

6.0 External Grounding (Optional) 6.1 Wrap the ground strap around the shield sleeve with the tails toward the cable jacket (Figure 16). Ensure that the shield sleeve is over the tape, LC, or wire shield. Shield Sleeve Ground Strap Figure 16 6.2 Secure ground strap to the shield sleeve using a constant force spring (Figure 17). Constant Force Spring Figure 17 6.3 Overwrap the spring with two layers of stretched vinyl tape (Figure 18). Vinyl Tape Figure 18 78-8127-8892-1 Rev B 11

6.4 Place one mastic sealing strip on the cable jacket under the solder blocks of the ground strap no farther than 1/2" (13 mm) from the jacket edge (Figure 19). 1/2 max (13 mm) Mastic Strip Figure 19 6.5 Place another mastic strip over the solder blocks. Press the mastic strips around the solder blocks and onto the cable jacket. If tails overlap at the solder blocks, place a piece of mastic between them (Figure 20). 1/2 max (13 mm) Mastic Strip Figure 20 12 78-8127-8892-1 Rev B

7.0 Install Jacket Jacketing is not optional. 7.1 Wrap a roll of slightly stretched Scotch Rubber Mastic Tape 2228, 2" x 36" around cable jacket ends (tacky side toward cable) (Figure 21). If grounding was applied, apply tape over mastic strips at solder block. Stretch and tear off last 1-2" (25-50 mm) of mastic (Figure 22). 2" rubber mastic 2" rubber mastic Figure 21 Stretch and tear off last 1-2" (25-50 mm) of rubber mastic Figure 22 7.2 Install the rejacketing tube by twisting the tube (not the liner) from side to side to start the movement. Then slide and unroll the tube over the constant force springs and rubber mastic. (Figure 23). Repeat on other side. Twist to break seal, then slide tube Liner Figure 23 78-8127-8892-1 Rev B 13

7.3 Remove the liners and discard. 7.4 Connect optional grounding. Figure 24 In applications where the splice is regularly exposed to high levels of ultra-violet radiation (i.e. direct sunlight), wrap two half-lapped layers of Scotch Super 33+ Vinyl Electrical Tape or Scotch Vinyl Electrical Tape Super 88 over the rejacketing tube. 14 78-8127-8892-1 Rev B

Crimping Tool - Die Sets (number of crimps/end) 3M Connector Number Conductor Size (kcmil) Y34A Burndy Y35, &39 Y45*, Y46* Thomas & Betts Corp. Y1000** TBM 8 TBM 12 TBM 15 Square D Co. Anderson Div. VC6-3** VC6-FT** VC8C** 10011 (Cu) 350 A31R (2) U31RT (2) Red (3) 71H (3) (2) 20011 (Al/Cu) 350 U31ART (2) (1) 87H (3) 87H (3) (2) 11011 (Cu) 350 A31R (2) U31RT (3) Red (4) 71H (4) (3) Cl-350 (Al/Cu) 350 U31ART (2) 87H (2) 87H (2) (3) 20012 (Al/Cu) 400 U32ART (4) (1) 94H (4) 94H (4) (2) (2) 10014 (Cu) 500 A34R (2) U34RT (2) Brown (3) 87H (3) (2) 20014 (Al/Cu) 500 U34ART (4) (1) 106H (3) 106H (4) (2) (2) 11014 (Cu) 500 A34R (2) U34RT (3) Brown (4) 87H (4) (3) Cl-500 (Al/Cu) 500 U34ART (3) 106H (3) (3) 20016 (Al/Cu) 600 U36ART (4) (1) 115H (3) (3) (3) 10019 (Cu) 750 U39RT (3) 106H (3) 20019 (Al/Cu) 750 U39ART (4) 125H (5) (3) (3) 11019 (Cu) 750 U39RT (5) 106H (4) Cl-750 (Al/Cu) 750 S39ART (3) 140H (3) (3) 10024 (Cu) 1000 20024 (Al/Cu) 1000 11024 (Cu) 1000 S44RT, P44RT (4) S44ART, P44ART (4) S44RT, P44RT (4) 125H (3) 140H (4) 125H (4) *Y45 and Y46 accept all Y35 dies ( U Series ). For Y45, use PT6515 adapter. For Y46, use PUADP adapter. **Anderson VC6-3, VC6-FT, VC8C and Burndy Y1000 require no die set. 78-8127-8892-1 Rev B 15

3M, Super 33+, and Scotch are trademarks of 3M Company. UniShield is a registered trademark of General Cable Technologies Corporation. All other trademarks are the property of their respective owners. Important Notice All statements, technical information, and recommendations related to 3M's products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M's current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture at the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any direct, indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electrical Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 800.245.3573 Fax 800.245.0329 www.3m.com/electrical Please Recycle. Printed in USA. 3M 2016. All Rights Reserved. 78-8127-8892-1 Rev B