ACT20X Series for hazardous area applications Section A

Similar documents
Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Process Transmitter RMA 422

Technical Information RIA45

Process transmitter RMA422

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

RMA42. Technical Information

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

PMG. Vibration Energy Harvesters

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

Display Information Type Backlit blue on white STN Type

Set Point Controller OC557. Operator s Manual

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Assembly. Front view. LEDs. Parametrization interface. Power Bus

TFR5 Room or outdoor temperature sensor. CombiTemp TM

263 Series LED Bargraph Indicator and Controllers

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Inductive sensor BI1.5-EG08K-Y1

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Capacitance Level Measurement Electronic insert FEC 12

LAUREL ELECTRONICS, INC.

TFRN Industrial RTD temperature sensor. CombiTemp TM

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMP 331i / DMP 333i LMP 331 i

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

PROPORTIONAL VALVES Sentronic plus

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Signal conditioning instruments

02/11/2015

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Pressure transmitter For applications in hazardous areas Model IS-3

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Linear flow control with actuator IFC

HS-509 VIBRATION TRIP MODULE

Thermocouple and RTD Modules for Compact FieldPoint

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Magnecraft Power Relays

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Linear flow controls VFC Linear flow controls with actuator IFC

Level Measurement silometer FMC 420, FMC 423

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Solution Selection Guide

TFRN Industrial RTD temperature sensor. CombiTemp TM

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

General Specifications

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Photoelectrics Through-beam Type PA18C.T..., DC

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Multifunction devices

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Hybrid Chart Recorder 250 mm (10")

SOFTLINK 300. Modules Specifications. Reference Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Kuhnke Technical Data. Contact Details

Model Number Structure

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

EP Release 500 August 2018, Version 1.2

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

ATEX-manual for units

02/11/2015

DCP100 Digital Control Programmer Specifications

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Circuit-Breakers for Motor Protection Series 8523/8

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Indoor Linear 80W Driver SI-C215280N2KR

General Specifications

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

SI-510 DUAL TRIP AMPLIFIER

MODEL IAMS INTELLIGENT UNIVERSAL SIGNAL CONDITIONING MODULE

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Pen and Multichannel Recorder: Digital Display

Rack mounted telephone- and leased line modem for industrial applications

Wall-/Pipe-Mount Level Indicator

Flow Measurement SITRANS F M

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Fibre Optic Modem ODW-622

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Operating instructions Electronic preset counter Type series 717

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FLEX Ex System Certification

Transcription:

ACT20X Series for hazardous area applications Section A Weidmüller has specifically designed the ACT20X line for process automation applications in Ex and non-ex zones. The 17 different variants can process all standard input signals (such as 2-wire, HART -, NAMUR-, RTD, thermocouple or DC signals) from Ex zone 0. They can also handle digital or analogue signals from Ex-zone field devices to the controller. www.weidmüller.com.au

ACT20X Series for hazardous area applications ACT20X Intrinsically safe isolators for hazardous area applications ACT20X signal converters The ACT20X is a completely new line of signal converter products for the Ex zone. These compact modules typically require only 11 mm per channel and take up very little space in the electrical cabinet. Weidmüller has specifically designed the ACT20X line for process automation applications in Ex and non-ex zones. The 17 different variants can process all standard input signals (such as 2-wire, HART -, NAMUR-, RTD, thermocouple or DC signals) from Ex zone 0. They can also handle digital or analogue signals from Ex-zone field devices to the controller. The integrated relay output issues an alert in the event of a sensor malfunction; this makes troubleshooting easier and reduces facility down times. The WI-Manager configuration software is based on FDT (Field Device Tool) technology. The software allows you to configure all ACT20X products with your PC so that they can be custom-fit to a wide variety of process applications. Weidmüller provides a device type manager (DTM) for the ACT20X modules that can be used in any FDT-based frame. The DTMs allow you to configure different devices quickly and accurately. They also enable you to analyse measurements and diagnostics data. The DTM can also be used to clearly identify the connected device. The FDT frame application WI Manager and the device-specific DTMs are available from Weidmüller free of charge. The ACT20X modules can be used in a temperature range from 20 C to 60 C without limitations. The modules can be installed in the safe zone or in the explosion risk area of Zone 2. The ACT20Xs always deliver a pure, interference-free signal thanks to their accuracy, temperature stability and high insulation strength. They can easily be used around the globe since they already have all the necessary international approvals, including ATEX, IECEx, GOST and FM. The newest member of the ACT20X family is the ACT20X-HUI-SAO-LP. This offers an intrinsically safe input for 0/4 to 20 ma, 0 to10 V, temperature and resistance signals, and separates the Ex zone from the safe zone using output loop powered technology. The narrow 12.5mm module is supplied via the 4 to 20 ma output. Features International approvals for Zone 0, 1 and 2 (IECEx, ATEX) and Class 1 Division 1 and 2 (FM) Analogue and binary signal interface to Zone 0/Div.1 for explosion-risk inputs and outputs All standard input signals (4 to 20 ma HART -, NAMUR-, RTD- or thermocouple signals) out of Ex zone 0, 1 or 2 Two-channel type saves space in the electrical cabinet and reduces installation costs HART transparent signal isolator Integrated alarm contact Configuration over FDT/DTM standard with the frame application software WI Manager A.2

Hazardous Area Digital Input / Safe Area Relay Output Features Namur or closed contact input 1 or 2 channels Input wiring selection according to terminal numbers Relay output <2Hz Fault relay standard IECEX & ATEX approval Installation in Zone 2 24Vdc supply Description Weidmüller ACT20X-HDI-SDO-Rxx models accept Namur sensor or closed contacts in the hazardous area from Zone 0,1,2 and repeat the signal through relay contacts in the safe area. A status relay is supplied for input fault detection with LED indication on front panel providing operational status. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Hazardous area) IECEX Namur supply Input parameters Volt free conatct or Namur sensor to EN60947 according to terminal numbers 8Vdc / 8mA resistance : 1kΩ Pulse Duration >0.1mS resistors RS=15kΩ (Lead breakage) RP=750Ω (short Circuit) Terminals Channel 1: 11-14 Channel 2: 21-24 Outputs (Safe/ Zone 2) Relay SPST. NO or NC model dependent or configured using WI Manager Terminals Channel 1: 41,42 Channel 2: 43,44 Switching Frequency 2Hz Rated switching Voltage relay Rated switching Voltage Safe Area: 250Vac/ 30Vdc 500VA/60W 2A AC/DC Zone 2: 32Vac / 32Vdc 16VA / 32W 2A AC/DC Identifies Input error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2V - 31.2Vdc 3watts (2 channels ) terminals 51-, 52 Temperature Rating Protection Degree MTBF Insulation Operational: -20 to 60 C Storage: -20 to 85 C 0-95%RH (non condensing) IP20 207 years 300V Rated - 2.6kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight Ex Data IECEX: KEM09.0072X 182 g IECEx ATEX (KEMA09ATEX0168X) Ex na nc IIC T4 Gc, [Ex ia Ga] IIC/IiB/IIA, [Ex ia Da] IIIC Uo = 10.6 V; 10 = 12 ma; Po = 32 mw; Co = 2.0 uf (IIC) or 6.0 uf (IIB) or 18.0 uf (IIA); Lo = 260 mh (IIC) or 780 mh (IIB) or 1000 mh (IIA); Lo/Ro = 1150 uh/o (all groups); for Ex iad, the parameters of group IIB apply. All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-HDI-SDO-RNO-S Single Channel, Screw Connection, Normally Open Contact Output 8965340000 ACT20X-HDI-SDO-RNC-S Single Channel, Screw Connection, Normally Closed Contact Output 8965350000 ACT20X-2HDI-2SDO-RNO-S Dual Channel, Screw Connection, Normally Open Contact Outputs 8965370000 ACT20X-2HDI-2SDO-RNC-S Dual Channel, Screw Connection, Normally Closed Contact Outputs 8965380000 CBX200 USB Configuration Interface 8978580000 A.3

Input signals Output signals Channel 1: NAMUR Mechanical switch R p R s R p 14 13 12 11 44 43 42 41 Relay Channel 2: N.O. or N.C. Relay Relay Channel 1: N.O. or N.C. Relay Opto Opto Opto Opto Channel 2: NAMUR Mechanical switch R p R s R p 24 23 22 Power supply Gnd. 51 Supply 19,2...31,2 V DC 52 53 N.C. 21 54 Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, gr. A-D or safe area NAMUR Sensor Interface - Single and Dual Versions EX Zone Safe zone A.C. supply Control 24 V DC Power supply Fill level is high, intrinsically safe Namur or mechanical switch PS 0 V - Other converter Channel 1 digital input Channel 1 digital output Zone 0 Channel 2 digital input Channel 2 digital output ACT20X-2HDI-2SDO Tank Fill level is low, intrinsically safe Namur or mechanical switch A.4

Hazardous Area Digital Input / Safe Area Transistor Output Features Namur or closed contact input 1 or 2 channel models Input wiring selection according to terminal numbers Transistor output <5kHz Fault relay standard IECEX & ATEX approval Installation in Zone 2 24Vdc supply 22.5mm wide housing Description Weidmullers ACT20X-HDI-SDO models accept Namur sensor or closed contacts in the hazardous area from Zone 0,1,2 and repeat the signal through transistor outputs in the safe area up to 5kHz. A status relay is supplied for input fault detection with LED indication on front panel providing operational status. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Hazardous area) IECEX Namur supply Input parameters Volt free conatct or Namur sensor to EN60947 acc to terminal numbers 8Vdc / 8mA resistance : 1kΩ Pulse Duration >0.1mS resistors RS=15kΩ (Lead breakage) RP=750Ω (short Circuit) Terminals Channel 1: 11-14 Channel 2: 21-24 Outputs (Safe/ Zone 2) NPN Transistor output Terminals Channel 1: 41,42 Channel 2: 43,44 Switching Frequency <5kHz Rated switching Voltage relay Rated switching Voltage Safe Area: 30Vdc; 80mA ( max 2.4W) 2.5V drop at max load Zone 2: U max=30vdc, I max=80ma Identifies Input error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2V - 31.2Vdc 3watts (2 channels ) terminals 51-, 52 Temperature Rating Protection Degree MTBF Insulation Operational: -20 to 60 C Storage: -20 to 85 C 0-95%RH (non condensing) IP20 215 years 300V Rated - 2.6kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight Ex Data IECEX: KEM09.0072X 182 g IECEx ATEX (KEMA09ATEX0168X) Ex na nc IIC T4 Gc, [Ex ia Ga] IIC/IiB/IIA, [Ex ia Da] IIIC Uo = 10.6 V; 10 = 12 ma; Po = 32 mw; Co = 2.0 uf (IIC) or 6.0 uf (IIB) or 18.0 uf (IIA); Lo = 260 mh (IIC) or 780 mh (IIB) or 1000 mh (IIA); Lo/Ro = 1150 uh/o (all groups); for Ex iad, the parameters of group IIB apply. All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-HDI-SDO-S Single Channel, Screw Connection, NPN Transistor Output 8965360000 ACT20X-2HDI-2SDO-S Dual Channel, Screw Connection, NPN Transistor Outputs 8965390000 CBX200 USB Configuration Interface 8978580000 A.5

Input signals Output signals Channel 1: NAMUR Mechanical switch R p R s R p 14 13 12 11 44 43 42 41 Relay Channel 2: N.O. or N.C. Relay Relay Channel 1: N.O. or N.C. Relay Opto Opto Opto Opto Channel 2: NAMUR Mechanical switch R p R s R p 24 23 22 Power supply Gnd. 51 Supply 19,2...31,2 V DC 52 53 N.C. 21 54 Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, gr. A-D or safe area NAMUR Sensor Interface - Single and Dual Versions EX Zone Safe zone A.C. supply Control 24 V DC Power supply Fill level is high, intrinsically safe Namur or mechanical switch PS 0 V - Other converter Channel 1 digital input Channel 1 digital output Zone 0 Channel 2 digital input Channel 2 digital output ACT20X-2HDI-2SDO Tank Fill level is low, intrinsically safe Namur or mechanical switch A.6

Safe Area Digital Input / Hazardous Area Digital Output (IIC) Features IIC/IIB/IIA/IIIC 3 I.S output parameters per module Uo = 28V for older equipment Fault relay standard IECEX & ATEX approval Installation in Zone 2 24Vdc supply 22.5mm wide housing Description The ACT20X-SDI-HDO-L models provide a powered output to the hazardous area (Gas group IIC) for Zone 0,1,2 for Valves, LED s, alarms etc. The output state is derived from a logic level from the safe area. A status relay is supplied for fault detection with LED indication on front panel provides operational status. The ACT20X-SDI-HDO-L comprises a single and a dual channel model. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Safe area) PNP, NPN, Switching voltage Input parameters Low level: (NPN) 2Vdc (PNP) 8Vdc Input parameters High Level: (NPN)>=4Vdc (PNP) >=10Vdc Max 28Vdc Terminals Channel 1: 41,42 Channel 2: 43,44 Outputs (Hazardous area) IECEX 3 Intrinsically safe output parameters exist on each model dependent on terminal selection 11-14 & 21-24 Terminals Channel 1: 11-14 Channel 2: 21-24 Maximum values Uo=28V; Co=80nF (IIC) or 640nF (IIB) or 2.1uF (IIA): Ex ia IiC/IIB/IIA/IIIC Terminals 11,12: 21,22 (304Ω) Io=93mA; Po=0.65W; Lo=4.2mH (IIC)16.8mH (IIB) 32.6mH (IIA). Lo/Ro = 54uH/Ω (IIC) 218uH/Ω (IIB) 436uH/Ω (IIA) Terminals 11,13: 21,23 (280Ω) Terminals 11,14: 21,24 (257Ω) relay Rated switching Voltage Io=100mA; Po=0.7W; Lo=3.5mH (IIC) 14.2mH (IIB) 27.6mH (IIA); Lo/Ro = 50uH/Ω (IIC) 201uH/Ω (IIB) 402uH/Ω (IIA) Io=110mA; Po=0.77W; Lo=2.9mH (IIC) 11.8mH (IIB) 22.8mH (IIA); Lo/Ro = 46uH/Ω (IIC) 184uH/Ω (IIB) 369uH/Ω (IIA) Identifies Output error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2V - 31.2Vdc 2watts (1 channel) 3.5 watts (2 channels ) terminals 51-, 52 Temperature Rating Protection Degree MTBF Insulation Operational: -20 to 60 C Storage: -20 to 85 C 0-95%RH (non condensing) IP20 175 years 300V Rated - 2.6kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight 182 g Ex Data IECEx- KEM09.0072X ATEX- KEMA10AATEX0019X FM UL DNV All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-SDI-HDO-L-S Single Channel, Gas Group IIC (35mA) Version 8965400000 ACT20X-2SDI-2HDO-L-S Dual Channel, Gas Group IIC (35mA) Version 8965420000 CBX200 USB Configuration Interface 8978580000 A.7

Ex Output Signals Input Signals Alarm Solenoid 14 44 V V V V Channel 1: 13 12 43 42 11 41 Alarm Solenoid 24 51 Power Supply Gnd. Channel 2: 23 22 52 53 19.2...31.2 V DC N.C. 21 54 Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / Cl. 1, div. 2, gr. A-D or safe area Driver for Solenoid/Actuator in Hazardous area - Gas Group IIC (35mA) - ACT20X Series for hazardous area applications Control system A.C. supply Safe zone EX Zone Ignition protection group IIC / IIB DC Power supply Ex alarm siren 19.2-31.2 V DC Alarm signal PS Channel 1 digital input Channel 1 digital output Channel 2 digital input Channel 2 digital output Zone 0 ACT20X-2SDI-2HDO Valve open/closed signal Solenoid valve Tank A.8

Safe Area Digital Input / Hazardous Area Digital Output (IIB) Features IIC/IIB/IIA/IIIC 3 IS output parameters per module (0.81W 0.95W) Uo = 28V for older equipment Fault relay standard IECEX & ATEX approval Installation in Zone 2 24Vdc supply 22.5mm wide housing Description The ACT20X-SDI-HDO-H provides a single 65mA digital output to the hazardous area (Gas group IIB) for Zone 0,1,2 Valves, LED s, alarms etc. The output state is derived from a logic level from the safe area. A status relay is supplied for fault detection with LED indication on front panel provides operational status. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Safe area) PNP, NPN, Switching voltage Input parameters Low level: (NPN) 2Vdc (PNP) 8Vdc Input parameters High Level: Terminals Channel 1: 41,42 Outputs (Hazardous area) IECEX Terminals Channel 1: 11-14 Maximum values Terminals 11,12 ratings (NPN)>=4Vdc (PNP) >=10Vdc Max 28Vdc 3 Intrinsically safe output parameters exist on each model dependent on terminal selection 11-14 & 21-24 Uo=28V; Co=80nF (IIC) or 640nF (IIB) or 2.1uF (IIA): Ex ia IiC/IIB/IIA/ IIIC or Ex iad Io=115mA; Po=0.81W; (Group IIC) Lo=2.69mH (IIC)10.8mH (IIB) 20.8mH (IIA). Lo/Ro = 44uH/Ω (IIC) 176uH/Ω (IIB) 353uH/Ω (IIA) Terminals 11,13 ratings Io=125mA; Po=0.88W; (group IIB) 9.1mH (IIB) 17.6mH (IIA); Lo/Ro = 163uH/Ω (IIB) 327uH/Ω (IIA) Terminals 11,14 ratings Io=135mA; Po=0.95W; (group IIB); Lo=7.8mH (IIB) 15.1mH (IIA); Lo/Ro = 150uH/Ω (IIB) 301uH/Ω (IIA) relay Rated switching Voltage Identifies Output error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2V - 31.2Vdc 2 watts (2 channels ) terminals 51-, 52 Temperature Rating Protection Degree MTBF Insulation Operational: -20 to 60 C ; Storage: -20 to 85 C 0-95%RH (non condensing) IP20 175 years 300V Rated - 2.6kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight 182 g Ex Data IECEx- KEM09.0072X ATEX- KEMA10AATEX0019X FM UL DNV All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-SDI-HDO-H-S Single Channel, Gas Group IIB (65mA) Version 8965410000 CBX200 USB Configuration Interface 8978580000 A.9

Ex Output Signals Input Signals Alarm Solenoid 14 44 V V V V Channel 1: 13 12 43 42 11 41 Alarm Solenoid 24 51 Power Supply Gnd. Channel 2: 23 22 52 53 19.2...31.2 V DC N.C. 21 54 Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / Cl. 1, div. 2, gr. A-D or safe area Driver for Solenoid/Actuator in Hazardous area - Gas Group IIC (35mA) or IIB (65mA) Versions - ACT20X Series for hazardous area applications Control system A.C. supply Safe zone EX Zone Ignition protection group IIC / IIB DC Power supply Ex alarm siren 19.2-31.2 V DC Alarm signal PS Channel 1 digital input Channel 1 digital output Channel 2 digital input Channel 2 digital output Zone 0 ACT20X-2SDI-2HDO Valve open/closed signal Solenoid valve Tank A.10

Hazardous Area Analogue Input / Safe Area Analogue Output Features IIC/IIB/IIA/IIIC 4-20mA input HART Transparent Transmitter supply IECEX & ATEX approval Installation in Zone 2 PC configurable with FDT/DTM 22.5mm wide housing 24Vdc supply Description The ACT20X-HAI-SAO is a 4-20mA intrinsically safe isolator with a HART modem. Available in 1 or 2 channel models and are suitable for isolating active inputs from 2 wire transmitters and passive inputs from powered field devices and retransmitting the 4-20mA to the safe side with high accuracy and stability whilst allowing simultaneous HART communication. The ACT20X-HAI-SAO is programmed using the CBX200 for selecting the output range and also location, serial number and users name along with diagnostics all through the WI Manager FDT/DTM Free software. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Hazardous area) Accepts active & passive 4-20mA inputs from Hazardous area Milliamp 0(4)-20mA ( Limts: 3.5-23mA) 2 wire Transmitter Channel 1: 14, 12- Channel 2: 24, 22- sensor supply 26V Passive input Channel 1: 11, 12- Channel 2: 21, 22- Output (Safe/ Zone 2) Output ranges 3.5 23 ma into 600Ω load 4-20mA Output Terminals wiring for sourcing <600Ω or 2 wire loop power (Vs - 10 V) / 20 ma (current loop) Accuracy Temperature Drift Step Response relay Rated switching Voltage Channel 1: 41,42 Channel 2: 43,44 <0.1% span < 0.01% of span/ C 5ms Alarm sensor error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2-31.2Vdc 3 watts (2 channels) terminals 51-, 52 Temperature Rating Protection Degree Insulation Operational: -20 to 60 C Storage: -20 to 85 C 0-95% RH (non condensing) IP20 300V Rated - 2.0kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight Ex Data IECEx:DEK 11.0050 X issue 0 Loop Current:terminals 13,14; 23,24 Current Input: terminal 11,12; 21,22 182 g IECEx ATEX (DEKRA11ATEX0131X) UL Ex na IIC T4 Gc, [Ex ia Ga] I/IIC/IIB/IIA, [Ex ia Da] IIIC Uo=28V; Io=93mA; Po=0.65W; Co=0.08uF (IIC); 0.6uF (IIB); 2.15uF (IIA) All certificates available from www.weidmuller.com.au Ui=30V; Ii=120mA; Pi=0.85W; Ci=2nF;Li=0uH; Uo=0V; Io=0mA; Po=0mW Ordering Data Type Description Order No. ACT20X-HAI-SAO-S Single Channel version 8965430000 ACT20X-2HAI-2SAO-S Dual Channel version 8965440000 CBX200 USB Configuration Interface 8978580000 A.11

Input Signals Output Signals Analogue, 4...20 ma Channel 1: Current Tx 44 14 43 13 42 12 41 11 42 41 44 43 2-wire supply 4...20 ma mama 2-wire supply 2-wire supply ma ma 2-wire supply 4...20 ma Channel 2: Channel 1: Power Supply and Module Status 24 51 Gnd. Channel 2: Tx 23 22 21 52 53 54 Supply 19,2...31,2 V DC N.C. Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, gr. A-D or safe area Isolators for Signal Current from the Hazardous area - Single and Dual Versions EX Zone Safe zone A.C. supply Control system 24 V DC Power supply 2-wire HART head transmitter for temperature 0 V - 24 V DC 4-20 ma / HART input I PS I To other isolators 4-20 ma / HART output Passive input channel Zone 0 ACT20X-HAI-SAO Tank A.12

Safe Area Analogue Input / Hazardous Area Analogue Output Features IIC/IIB/IIA/IIIC 4-20mA output HART Transparent Sensor fail standard IECEX & ATEX approval Installation in Zone 2 PC configurable with FDT/DTM 22.5mm wide housing 24Vdc supply Description The ACT20X-SAI-HAO is a 4-20mA intrinsically safe isolator with a HART modem. Available in 1 or 2 channel models, are suitable for isolating 4-20mA from the safe area and retransmitting to the hazardous area for controlling valves, I-P converters etc and simultaneous HART communication. The ACT20X-SAI-HAO is programmed using the CBX200 for selecting the output range and also location, serial number and users name along with diagnostics all through the WI Manager FDT/DTM Free software. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Safe area) Accepts active & passive 4-20mA inputs Milliamp 0(4)-20mA ( Limts: 3.5-23mA) Terminals Channel 1: 42, 41- Channel 2: 44, 43- Output (Hazardous Area) output ranges 3.5 23 ma into 600Ω load 4-20mA Output Terminals Channel 1: 11,12 Channel 2: 21,22 Accuracy relay Rated switching Voltage <0.01% span/100 Ω Alarm sensor error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2-31.2Vdc 3 watts (2 channels) terminals 51-, 52 Temperature Rating Protection Degree Insulation Operational: -20 to 60 C Storage: -20 to 85 C 0-95% RH (non condensing) IP20 300V Rated - 2.0kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight Ex Data IECEx: DEK 11.0059 X, issue 0 182 g IECEx ATEX (DEKRA11ATEX0164X) UL Ex na IIC T4 Gc, [Ex ia Ga] I/IIC/IIB/IIA, [Ex ia Da] IIIC Loop supply terminals 11,12 resp terminals 21,22 Ex ia IiC/IIB/IIA Uo=28V; Io=93mA; Po=0.65W; Co=0.08uF (IIC); 0.65uF (IIB); 2.15uF (IIA); Lo=4mH (IIC); 16mH (IIB); 32mH (IIA) All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-SAI-HAO-S Single Channel 8965450000 ACT20X-2SAI-2HAO-S Dual Channel 8965460000 CBX200 USB Configuration Interface 8978580000 A.13

- ACT20X Series for hazardous area applications Ex Output signals Input signals Analogue, 4...20 ma 44 14 42 Channel 1: Load 4...20 ma 43 13 42 12 41 11 41 44 43 Ch 2 Ch1 Power Supply and Module Status 24 51 Gnd. Channel 2: Load 4...20 ma 23 22 21 52 53 54 Supply 19,2...31,2 V DC N.C. Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, gr. A-D or safe area Isolators for Control Currents to the Hazardous area - Single and Dual Versions Control system A.C. supply Safe Zone EX-Zone Power supply 24 V DC 0 V 24 V DC PS HART val ve Actuator Actuator 4-20 ma / HART input I I 4-20 ma / HART output Output Control system Positioning transmitter ACT20X -SAI-HAO Control va lv e A.14

Hazardous Area Universal Input / Safe Area Loop Powered Output Features I/IIC/IIB/IIA/IIIC Universal Input 2 wire Output Loop Powered RTD, Tc, mv, V, ma, Ω, Pot IECEX & ATEX approval Installation in Zone 2-20 C to 60 C operation 12.5mm wide housing PC configurable with FDT/DTM Description The ACT20X-HUI-SAO-LP is a 4-20mA output loop powered intrinsically safe isolator with a universal input accepting RTD s, Thermocouples, mv, V, ma, resistance and potentiometers. All ranges have a small minimum span with great accuracy and repeatability. The HUI-SAO-LP is programmed using the CBX200 for selecting the input type, range, output linearity and also location, serial number and users name along with diagnostics all through the WI Manager FDT/DTM Free software. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Hazardous area) RTD Thermocouples Milliamp mv, Volts Resistance 2w, 3w Potentiometer Accepts passive analogue inputs from Hazardous area Pt100, Pt200, Pt1000, Ni20, CU10 in 2 & 3 wire connection ( max 5Ω per wire) B, E, J, K, L, N, R, S, T, U (or user defined 101 points) Plus & minus 25mA, minimum span 1mA Plus & minus 150mV, 600mV, 12V, or 28Vdc 0-12kΩ Input Terminals 11, 12, 21, 22 Output (Safe/ Zone 2) 1.2kΩ to 500kΩ end to end resistance 4-20mA loop powered into 700Ω load Output Terminals 42: 24V 41: 4-20mA return Accuracy Temperature Drift <0.05% span < 0.02% of span/ C Step Response 400ms ( 10-90% ) Power supply 11-28Vdc loop powered 3watts (2 channels ) terminals 51-, 52 Temperature Rating Protection Degree Insulation Operational: -20 to 60 C Storage: -20 to 70 C 10-90% RH (non condensing) IP20 300V Rated - 2.0kV Input / Output Dimensions mm L= 117.2 W= 12.5 H= 113.6 Weight 160 g Ex Data IECEx ATEX UL IECEX: ITA 11.0002X Terminal 21 & 12 Terminal 22 & 12 Terminal 11 & 12 Terminal 21,22 & 11,12 Ex na IIC T4 Gc, [Ex ia Ga] I/IIC/IIB/IIA, [Ex ia Da] IIIC Uo 5.88V; Io 3.1mA; Po 4.6mW; Ci 0.001uF; Li neg mh Uo 5.88V; Io 0.003mA; Po <1.0mW; Ci 0.001uF; Li neg mh Uo 5.88V; Io 79.2mA; Po 116.4mW; Ci 0.001uF; Li neg mh Uo 5.88V; Io 82.3mA; Po 121mW; Ci 0.003uF; Li neg mh All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-HUI-SAO-LP-S Universal Hazardous Area Signal Converter/Isolator - loop Powered 1318220000 CBX200 USB Configuration Interface 8978580000 A.15

Input Signals Output Signals POT RTD/RES 3-wire 2-wire TC mv ma Volt 11 41 - Loop Powered (4-20mA) - 12 42 Loop Powered (4-20mA) 21 22-20 Ta 60 C Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, gr. A-D or safe area Universal Hazardous Area Signal Converter/Isolator - Output Loop Powered Zone Safe Zone Control system es st n e em er t re ensor m t t t e n t C nnel one AC20X-HUI-SAO-LP n A.16

Hazardous Area Universal Input / Safe Area Analogue Output Features IIC/IIB/IIA/IIIC Universal Input RTD, Tc, mv, V, ma, Ω, Pot IECEX & ATEX approval Installation in Zone 2-20 C to 60 C operation 22.5mm wide housing PC configurable with FDT/DTM 24Vdc power supply Description The ACT20X-HUI-SAO 24Vdc powered intrinsically safe isolator with a universal input accepting RTD s, Thermocouples, mv, V, ma, resistance and potentiometers. All ranges have a small minimum span with great accuracy and repeatability. The HUI-SAO is programmed using the CBX200 for selecting the input type, range, output linearity and also location, serial number and users name along with diagnostics all through the WI Manager FDT/DTM Free software. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Technical Data Inputs (Hazardous area) RTD Accepts active & passive analogue inputs from Hazardous area Pt10, Pt20, Pt50, Pt100, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Thermocouples B, E, J, K, N, R, S, T,. L and U in acc with DIN 43710 Milliamp 0(4)-20mA ( Limts: 0-23mA) sensor supply 26V Volts 0-1, 0.2-1, 0-5, 0-10, 2-10V Input Terminals 11-14, 21-24 Output (Safe/ Zone 2) output ranges 0 23 ma into 600Ω load configurable: 0 20 / 4 20 / 20 0 / 20 4 ma Output Terminals 41,42 wiring for sourcing <600Ω or 2 wire loop power (Vs - 10 V) / 20 ma (current loop) Accuracy Temperature Drift <0.05% span < 0.02% of span/ C Step Response 400ms ( 10-90% ) relay Rated switching Voltage Alarm on Power, sensor error or threshhold alarm ( selectable via FDT/ DTM) Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc Power supply 19.2-31.2Vdc 3.5watts terminals 51-, 52 Temperature Rating Protection Degree MTBF Insulation 16VA / 32W 0.5A AC/ 1ADC Operational: -20 to 60 C Storage: -20 to 85 C 0-95% RH (non condensing) IP20 74 years 300V Rated - 2.0kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight 182 g Ex Data IECEx ATEX (KEMA10ATEX0071X) UL IECEx: KEM 10.0034X issue 0 Ex na IIC T4 Gc, [Ex ia Ga] I/IIC/IIB/IIA, [Ex ia Da] IIIC Please see approval for all values All certificates available from www.weidmuller.com.au Ordering Data Type Description Order No. ACT20X-HUI-SAO-S Universal Hazardous Area Signal Converter/Isolator - Auxiliary Powered 8965490000 CBX200 USB Configuration Interface 8978580000 A.17

Input signals Output signals * 44 14 43 13 42 41 ma 2-wire supply ma 2-wire supply 4...20 ma 42 12 41 11 44 43 Relay N.O. Relay Input signals Power Supply 24 51 Gnd Tx 23 22 21 52 53 54 Supply 19,2...31,2 V DC N.C. Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, div. A-D or safe area Universal Hazardous Area Signal Converter/Isolator - Auxiliary Powered EX Zone Safe zone A.C. supply Control system 24 V DC Power supply 0 V - I PS I Other devices 4-20 ma output Passive input channel Positional potentiometer ACT20X-HUI-SAO Valve A.18

Hazardous Area Temperature Input / Safe Area Analogue Output Description The ACT20X-HTI-SAO is 24vdc powered intrinsically safe isolator accepting RTD s, Thermocouples, and ma from the hazardous area and converts to 4-20mA on the safe side. The HTI-SAO is programmed using the CBX200 and WI Manager FDT/DTM Free software for selecting the input type, range, output and also location, serial number and users name along with diagnostics. All Terminals have guided entry with lever action for removal, providing a secure connection under all conditions including vibration. Ordering Data Technical Data Inputs (Hazardous area) RTD Features IIC/IIB/IIA/IIIC ma, RTD, Thermocouples IECEX & ATEX approval Fault relay standard Installation in Zone 2-20 C to 60 C operation 22.5mm wide housing PC configurable with FDT/DTM 24Vdc power supply Accepts passive analogue inputs from Hazardous area Pt10, Pt20, Pt50, Pt100, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Thermocouples B, E, J, K, N, R, S, T,. L and U in acc with DIN 43710 Milliamp 0(4)-20mA ( Limts: 0-23mA) Input Terminals Channel 1: 11-14 Channel 2: 21-24 Output (Safe/ Zone 2) Output ranges 3.8 20.5 ma,0-20.5ma into 600Ω load configurable: 0 20 / 4 20 / 20 0 / 20 4 ma Output Terminals Channel 1: 41,42 Channel 2: 43,44 wiring for sourcing <600Ω or 2 wire loop power (Vs - 10 V) / 20 ma (current loop) Accuracy Influence of load resistance <0.01% span <0.01%/ 100Ω Step Response 400ms ( 10-90% ) relay Rated switching Voltage Alarm on sensor error Safe Area: 125Vac/ 110Vdc 62.5VA/32W 0.5A AC/ 0.3ADC Zone 2: 32Vac / 32Vdc 16VA / 32W 0.5A AC/ 1ADC Power supply 19.2-31.2Vdc 3.5watts terminals 51-, 52 Temperature Rating Protection Degree MTBF Insulation Operational: -20 to 60 C Storage: -20 to 85 C 0-95% RH (non condensing) Type Description Order No. ACT20X-HTI-SAO-S Single Channel 8965470000 ACT20X-2HTI-2SAO-S Dual Channel 8965480000 ACT20X-CJC-HTI-S PRT 11 Cold Junction Compensating terminal blocks for channel one 1160640000 ACT20X-CJC-HTI-S PRT 21 Cold Junction Compensation terminal blocks for channel two 1160650000 CBX200 USB Configuration Interface 8978580000 IP20 111 years 300V Rated - 2.0kV Input / Output Dimensions mm L= 117.2 W= 22.5 H= 113.6 Weight 182 g Ex Data IECEx ATEX (KEMA10ATEX0020X) UL IECEx: KEM 09.0092x Ex na IIC T4 Gc, [Ex ia Ga] I/IIC/IIB/IIA, [Ex ia Da] IIIC Sensor terminals 11-14 and 21-24 respectively Ex ia IIC/IIB/IIA or Ex iad with the following Max values Uo=8.7V; Io=18.4mA; Po=40mW; Co=5uF (IIC) 50uF (IIB) 1000uF (IIA); Lo=100mH (IIC) or 250mH (IIB) or 600mH (IIA); Lo/Ro=445uH/Ω (all groups) Ui=10V; Ii=30mA; Ci=30nF; Li=820nH values for combined inputs available. Please see approval data All certificates available from www.weidmuller.com.au A.19

Input signals Output signals Channel 1: Current RTD Connection, wires TC 44 14 43 13 42 12 41 11 42 41 44 43 Analogue, 0/4...20 ma 2-wire supply 4...20 ma mama 2-wire supply 2-wire supply ma ma 2-wire supply 4...20 ma Channel 1 Channel 2 Current RTD Connection, wires TC 24 Supply and module status 51 Supply Channel 2: 23 22 21 52 53 54 Supply 19,2...31,2 V DC N.C. Zone 0, 1, 2, 20, 21, 22 / Cl. I/II/III, div. 1 gr. A-G Zone 2 / FM Cl. 1, div. 2, gr. A-D or safe areal Isolators for Temperature Measurements in the Hazardous area - Single and Dual Versions EX Zone Safe zone A.C. supply Control system 24 V DC Power supply Resistance temperature sensor 0 V - PS To other isolators Passive input I I 4-20 ma output Zone 0 ACT20X-HTI-SAO Tank A.20