TB806AUX / Cat.6A UTP Keystone Jack (Auto press-fit) Cable holder with Strain Relief (SR) function: secure the cable with cable tie, and not wiggle to affect the termination and transmission. Cap: easy to separate and change pair sequence and not tangle the wires. Press-fit process. 100% RoHS compliant, without soldering. Unique design can resist RJ11/ RJ12 for 200 insertion. (Patent number : M435745) IDC terminate conductor makes a better contact resistance and transmission. The keystone jacks come with T568A or T568B wiring and fully comply with ANSI/TIA568-C-2 specifications for Insertion Loss (Attenuation), Near-End Crosstalk (NEXT), Return Loss, and Far-End Crosstalk (FEXT) for data transmissions of any pair combination with frequencies up to 500. TB806AUD TB806AUT
Specification Specification: Qualified unscreened /Category 6A Permanent Link/Channel of ANSI/TIA-568-C.2 IEC 60603-7-41 AMD2 CENELEC EN 50173-1 Electrical: Current Rating: 1.5 Amps Insulation Resistance: 500 MΩ minimum Contact Resistance: 10 mω maximum DC Resistance: 0.1 Ω maximum Mechanical: Plug Insertion Life: 750 Cycles minimum Plug & Jack Contact Force: 100 Grams minimum using FCC-approved plug Plug Retention Force: 30 lbs minimum Temperature: -40 to 150 F (-40 to 68 C) Physicals: Housing: High impact flame retardant plastic, UL 94V-0 rated PCB: FR4, 1.6mm Thickness Jack Wire: 0.40 mm Phosphor bronze gold over nickel plating Connector: Insulation displacement connector (IDC) Accept #23~24 AWG solid wire TB80 XX X X - XX 58 : Cat.5e U : Unshielded D : door 68 : Cat.6 S : Shielded T : without door 6A : Cat.6A WH : White KT8002 Compress Tool HT80X8 Termination Tool
/ Cat.6A Standard Configuration Cat.6A or (500) AMD 2 CENELEC EN50173-1 EIA/TIA 568-C.2 Channel Permanent Link Channel Permanent Link Channel Permanent Link Cat.6A Cat.6A <<Comparison Chart I>> For the regional US American cabling standard, see <<Comparison Chart I>>, it describes channels and permanent links as Cat. 6A. For the international cabling standard and the European cabling standard EN 50173-1, both standards configurations like channels and permanent links are called. When you compare EIA/TIA with ISO/IEC or EN, they are not only naming differently, but also transmission performance requirements show significant variations, see below comparison charts. v.s. EIA/TIA568-C.2 Channel NEXT Limits Minimum NEXT db -20-30 Transmission performance differences between ISO/IEC and EIA/TIA 1.0 16.0 53.2 53.2 100.0 39.9 39.9-40 200.0 250.0 34.8 33.1 34.8 33.1-50 100 200 300 400 500 350.0 500.0 30.6 27.9 30.3 26.1 Minimum NEXT db -20-30 -40 v.s. EIA/TIA568-C.2 Permanent Link NEXT Limits -50 100 200 300 400 500 Transmission performance differences between ISO/IEC and EIA/TIA 1.0 16.0 100.0 200.0 250.0 350.0 450.0 500.0 54.6 41.8 36.9 35.3 32.6 30.2 27.8 54.6 41.8 36.9 35.3 31.8 26.7
Automatically Pressing contacts and IDC into a plated-through hole in the PCB. Advantages of Press-fit Connectors: - Stable and reliable form of the contact - Time-saving production - Cost effective, no manual soldering - Environmentally friendly - Reduced inspection process Patents and trade marks Automatically Pressing contacts and IDC into a plated-through hole in the PCB. The contact pins are bended by auto machine for better strength, togetter with contact support, the contact pins can resist RJ11/12 for 200 insertion. (Patent number : M435745) Owned 108 Patentsand 9 trade marks registered
L L R R / Cat.6A Relative Products KP24XX Keystone Type KP16XX Keystone Type 151.30 151.30 482.60 40 @27*15=405.00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Cat.6 31.80 44.00 PANEL & KSJ ASS'Y SIDE VIEW DR0101S-XX STP DIN Rail Adapter for Keystone Jack TA3700-X USA type Wall Plate for Keystone Jack
Relative Products TA6288-KWH 2P Surface Mount Box TA52202 French Wallplate (81x81) + Backbox Single Gang Backbox