ELECTRONIC SOMATIC CELL COUNT. Bentley Somacount 150/300/500/FCM (Raw Commingled Cow, Goat, Sheep, Water Buffalo and Camel Milk) IMS #16

Similar documents
SECTOR Imager Performance Qualification Kit

LEGEND MAX Human α-synuclein ELISA Kit with Pre-coated Plate Catalog No.: (Previously Covance Cat. No. SIG-38974)

APPENDIX I. Detailed procedure for estimation of purine derivatives : Determination of allantoin by a colorimetric method

INTERNATIONAL STANDARD

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

ECE 2274 Pre-Lab for Experiment Timer Chip

Tube Rotator. User Guide. Version 1.2

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

Calibration Certificate

Model KT 53 Cooling incubators with thermoelectric cooling

The use of an available Color Sensor for Burn-In of LED Products

Total Chlorine Sensor

Quality. Accurate, reliable results in a durable easy-to-use design

eblot L1 Protein Transfer System Fast Wet Transfer System for Mini Gels

Heavy Water 100-lap Instructions & Warranty

Vinmetrica SC-200 User Manual

More reliable zeta potential measurements. without dilution. Agilent Particle Analysis Solutions. Agilent 7020 ZetaProbe Zeta Potential Analyzer

Model KT 115 Cooling incubators with thermoelectric cooling

INSTALLATION AND OPERATION M

Digital Circuits I and II Nov. 17, 1999

Good Laboratory Practices (GLP) Notepad. Automatic Datalogging. Automatic Stability Function. P.I.N. Code Security Access.

CHM 110 / Guide to laboratory notebooks (r10) 1/5

bio bas.1 USER S MANUAL

Ultrospec 1100 pro. Description. UV/visible spectrophotometer. data file. UV/Visible Spectrophotometry. product code: see ordering information

Colorimeters and UV/Visible Spectrophotometers. from

Advanced Digital Melting Point Apparatus

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

WELDING CONTROL UNIT: TE 450 USER MANUAL

Features. Orange AlGaAs Red HER Yellow Green Package HDSP- HDSP- [1] HDSP- [1] HDSP- HDSP- Description Drawing

FLOMAT Electromagnetic Insertion Flowmeter

Operation of the ACEA NovoCyte Flow Cytometer

Light Source. Specification & User Manual

TEST WIRE FOR HIGH VOLTAGE POWER SUPPLY CROWBAR SYSTEM

This document courtesy of:

Biolyte 2000 Quick User Manual

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

5. Drain off excess 1X PBS (gently blot PBS off underside of coverslip after draining) and transfer slides/coverslips to humid chamber.

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

AIM INTRODUCTION SIMPLIFIED WORKFLOW

Model ED 23 Drying and heating chambers Classic.Line with natural convection

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

In Situ Hybridization Protocol Cryosections

WQ Series Water Quality Bench top Meters

Microwave Counter, Power Meter and DVM in One Portable Package

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

0RGHO.20LFUR&HOO.LW $VVHPEO\DQG&KHFNRXW,QVWUXFWLRQV

Instruction Manual. Electronic Level - Inclinometer Model No

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

CyAn User Manual. Flow & Mass Cytometry Center Biomedical Core facility. Technion Faculty of Medicine

Fragment Analyzer Genomic DNA Analysis Kit

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

XT-17M-B relay - Delay-off, 1 C/O, 16 A

WINTER 15 EXAMINATION Model Answer

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

EdiPower II HM Series (PAR) Datasheet

Real-Time PCR System TC

PAL LSI - Robust and Reliable Sample Handling

10Gbps 10km Range SFP+ Optical Transceiver

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

Data Sheet. HDSP-52xE Series HDSP-52xG Series HDSP-52xY Series 14.2 mm (0.56 inch) General Purpose Two Digit Seven Segment Displays

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

FACSAria I Standard Operation Protocol Basic Operation

OTHER FEATURES UNIQUE FEATURES

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

Keeping a Lab Notebook

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

ILC-LNF TECHNICAL NOTE

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

User interface. Abbreviations / Meanings

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KT 170 Cooling incubators with thermoelectric cooling

LITE-ON TECHNOLOGY CORPORATION

DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

EdiPower II HM Series Datasheet

FINGERPRINT RECOGNITION SAFE MODEL NO: CS400FP

Tube Roller Shakers. User Guide. Version 1.2

Charlie Foxtrot Features include:

Photonics solutions For innovative photonics

Effective Date: September Rev. 12/21/2017- Void After: September Product: Lead Free Plumbing Products File No. 6397

Practicality and Performance

Basic Operations App Guide

OFC & VLSI SIMULATION LAB MANUAL

Magnetic Drive Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Forced Convection Laboratory Ovens

1. Add Capture Antibody diluted in coating buffer. 4. Add standards, controls and samples to the plate in duplicate.

Description The 14.2 mm (0.56 inch) LED seven segment displays are designed for viewing distances up

ph GENERAL INFORMATION

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

Implementing a Rudimentary Oscilloscope

Factory configured macros for the user logic

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

013-RD

The world s fastest Spiral plater. easyspiral N

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

PAL LSI - Robust and Reliable Sample Handling

Transcription:

ELECTRONIC SOMATIC CELL COUNT Bentley Somacount 150/300/500/FCM (Raw Commingled Cow, Goat, Sheep, Water Buffalo and Camel Milk) IMS #16 (Unless otherwise stated all tolerances ±5%) 1. Laboratory Requirements (see Cultural Procedures (CP) items 33 & 34) a. Un-preserved samples may be run up to 72 hours after initial collection b. Samples may be tested up to 7 days after initial collection if preserved with 0.02% 2-bromo-2-nitropropane-1,3-diol (Bronopol ) or 0.05% potassium dichromate (K 2 Cr 2 O 7 ) 2. Comparative Test with DMSCC [NOT required as a co-requisite for certification of analysts in laboratories purchasing standards from a CERTIFIED provider (item 12.b)] a. Analyst(s) certified for DMSCC b. Each analyst seeking certification for the ESCC test shall perform the comparative test 1. Test 4 samples (100K-200K, 300K-500K, 600K-800K and 900K-1.2M) in triplicate for both DMSCC (three separate smears each) and ESCC 2. Results must be evaluated by the FDA/LPET LEO or LEO and shown to be acceptable prior to official use of test in laboratory 3. Copy of comparison and results in QC record (or easily accessible on file in the laboratory); kept for as long as analyst is certified c. Required for laboratories preparing in house standards or using commercially prepared standards (items 12.a and c) and for those testing goat or camel milk APPARATUS 3. See CP Items 1-4 4. Electronic Somatic Cell Counter a. Bentley Somacount 150 b. Bentley Somacount 300 c. Bentley Somacount 500 Dual Channel Machine (DCM) FORM FDA/NCIMS 2400h-2 Bentley Somacount Rev. 2/16 Page 1 of 6

d. Bentley Somacount FCM Dual Channel Machine (DCM) 5. Water Bath a. Circulating and thermostatically controlled to 37-42 C REAGENTS 6. Stock Dye/Buffer Solution a. Dissolve 80 g of tripotassium citrate monohydrate, (K 3 C 6 H 5 O 7,H 2 O), 3.0 g of citric acid monohydrate (C 6 H 8 O 7,H 2 O), and 0.25 g (1 tablet) of ethidium bromide (C 21 H 20 BrN 3 ) in 750 ml of deionized (DI) or MS water. Heat to 40-60 C and stir until totally dissolved b. Add 10 ml of neutral detergent, Triton X-100, and stir until totally dissolved. Adjust volume to 1 Liter with DI or MS water c. Store refrigerated (0-4.5 C) in airtight, light-proof container for no longer than 90 days Lab Prep Date: Lab Exp. Date: WORKING SOLUTIONS 7. Dye/Buffer Solution a. Dilute 1 part of Stock Dye/Buffer solution with 9 parts of DI or MS water b. Protect from light and use within 21 days Lab Prep Date: Lab Exp. Date: 8. Rinse Solution a. Add 20 ml of alkaline detergent, RBS-35, per liter of DI or MS water and mix b. Use within 7 days Lab Prep Date: Lab Exp. Date: 9. Optionally, Use Manufacturer's Reagent Kits and Instructions 10. All Solutions Labeled with Date Prepared and Expiration Date FORM FDA/NCIMS 2400h-2 Bentley Somacount Rev. 2/16 Page 2 of 6

START UP 11. Cell Counter a. Check that the volume of dye/buffer solution (item 7) and rinse solution (item 8) in the supply containers is of sufficient volume for the number of samples to be tested b. Solutions not to be used beyond expiration date(s) c. Turn on computer and instrument, wait 20 minutes before proceeding d. Laser power > 0.25 mw e. PMT voltage > 10 mv f. Dye/Coil temperature between 67-73 C g. Test DI or MS water at least 3 times on each channel in use; (i.e. 6 times for dual channel instruments) reading must be zero (0) on every test h. IF ANY ABOVE PARAMETERS ARE OUT OF TOLERANCE, CORRECT BEFORE PROCEEDING i. Maintain records on all parameters each time instrument is used 12. Milk Standards a. Commercially prepared: Lot#: Date Rcd.: 1. Four standards in ranges 100K-200K, 300K-500K, 600K-800K and 900K-1.2M 2. Perform DMSCC in triplicate on each standard in set and average counts; maintain records 3. Perform DMSCC check in rotation by all certified analysts 4. Standards used within one week Lab Exp. Date: b. Certified provider: Lot#: Exp. Date: Date Rcd.: 1. Four standards in ranges 100K-200K, 300K-500K, 600K-800K and 900K-1.2M FORM FDA/NCIMS 2400h-2 Bentley Somacount Rev. 2/16 Page 3 of 6

2. Maintain copies of all provided DMSCC values 3. Measure and maintain records of temperature (0.0-7.5 C) of standards as received 4. Maintain copies of all correspondence regarding problems 5. Standards used by manufacturer s expiration date 6. Failed standards shall be verified with DMSCC a. If no analysts certified for DMSCC then a new set of standards is required b. Do not continue with official testing until the new standard(s) test(s) in range c. Laboratory prepared (weekly) 1. Prepare from raw milk >18 hours old preserved with 0.05% potassium dichromate (K 2 Cr 2 O 7 ) 2. Or, preserved with 0.02% 2-brono-2-nitropropane-1,3-diol (Bronopol ) 3. Standards cannot be preserved with formalin 4. Prepare 4 standards in ranges 100K-200K, 300K-500K, 600K-800K and 900K-1.2M, use within one week Lab Prep Date: Lab Exp. Date: 5. Perform DMSCC in triplicate on each standard prepared and average counts; maintain records 6. Perform DMSCC check in rotation by all certified analysts d. Hourly Control Sample (instrument drift check) 1. Use one of the standards (items 12.a, b or c) in the 600-800K range; test in triplicate and determine average 2. Optionally, prepare sufficient control/sample 600-800K range, test in triplicate and determine average PROCEDURE 13. Testing Standards (each time instrument used) a. Heat standards to 37-42 C (using a temperature control) and test within 30 min of reaching temperature, use once and discard; i.e., do not re-use FORM FDA/NCIMS 2400h-2 Bentley Somacount Rev. 2/16 Page 4 of 6

b. Mix by inverting at least 2x, test standards within 3 min c. Test the standards in triplicate and average the counts for each level; maintain records d. Each standard's average must be within 10% of the DMSCC (item 12) for that level, except within 15% for 100-200K standard; maintain records e. Repeatability - a standard in the 300K to 800K range must have a coefficient of variation (CV) of 5% or less on 10 replicates (Refer to Operating Manual); maintain records f. For dual channel machines, the standards must be run in triplicate on each channel and coefficient of variation (CV) must be determined for each channel that is in use g. THESE PARAMETERS MUST BE ACHIEVED BEFORE PROCEEDING h. Dual Channel Machines (DCM) can be run on single channel 1. Switch off channel that does not meet above parameters per operating instructions 2. Run machine on single channel 14. Testing Samples a. Heat samples to 37-42 C (using a temperature control) and read within 30 min of reaching temperature b. Test samples within 10 min after removal from water bath c. Mix by inverting at least 2x, test samples within 3 min d. Record number of cells counted for each sample 15. With Continuous Operation: a. Run zero control (item 11.g) hourly b. Test a standard or optionally a control/sample (item 11.d) in the 600K to 800K range hourly in triplicate and determine the average, must be within 5% of the original established instrument average value (optionally, within 10% of original DMSCC average) c. For dual channel machines, the hourly control in triplicate and the zero control must be tested and found acceptable for each channel that is in use e. Maintain records FORM FDA/NCIMS 2400h-2 Bentley Somacount Rev. 2/16 Page 5 of 6

16. Routine Maintenance a. Maintain records REPORTING 17. Computing and Reporting of Counts a. Count obtained x 1000 is the cell count/ml milk b. In reporting electronic somatic cell counts (ESCC/mL), record only first two left hand digits, raising second digit to next higher number when third digit is 6 or more c. Report the two left hand digits (rounded) 1. If the third digit is 5, the second digit is rounded by the following rule a. When second digit is odd round up, raising the second digit by 1 (odd up, 235 to 240) b. When second digit is even round down, delete the 5 and report the second digit as is (even down, 225 to 220) d. If count on instrument is < 100, report count as < 100,000 ESCC/mL e. If goat or camel milk is over the regulatory limit, follow confirmation procedure in PMO FORM FDA/NCIMS 2400h-2 Bentley Somacount Rev. 2/16 Page 6 of 6