DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire: 0 0 V others on request Special characteristics suitable for oxygen applications insensitive to pressure peaks high overpressure capability Optional versions IS-version Ex ia = intrinsically safe for gases and dusts specific versions The industrial pressure transmitter DMP 5 is based on a welded stainless steel pressure sensor without fluid. This characteristic has a special advantage with applications where silicone oil or elastomeric seals cannot be used. Preferred areas of use are Medical technology Plant and machine engineering Commercial vehicles and mobile hydraulics Refrigeration Oxygen application BD SENSORS GmbH BD-Sensors-Straße Tel. +49 (0) 9 5 / 98-0 ww.bdsensors.com D - 9599 Thierstein Fax +49 (0) 9 5 / 98 - info@bdsensors.de
DMP 5 Input pressure range Nominal pressure gauge [bar] 6 0 6 5 40 60 00 60 50 400 600 Overpressure [bar] 0 50 80 0 00 0 500 800 00 Burst pressure [bar] 0 50 80 5 00 00 500 800 400 000 000 Vacuum resistance unlimited Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-version -wire: 4... 0 ma / V S = 0... 8 V DC Option -wire -wire: 0... 0 V / V S = 4... 0 V DC Performance Accuracy ± 0.5 % FSO Permissible load current -wire: R max = [(V S V S min ) / 0.0 A] voltage -wire: R min = 0 k Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / k Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Thermal error ± 0. % FSO / 0 K in compensated range 0 70 C Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 500 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.457 (6 Ti) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated others on request Seals (media wetted) none (welded) Diaphragm stainless steel.454 (7-4PH) Media wetted parts pressure port, diaphragm Explosion protection (only for 4 0 ma / -wire) Approvals IBExU 0 ATEX 068 X / IECEx IBE.007X DX9-DMP 5 zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V DC, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 H, the supply connections have an inner capacity of max. 7 nf to the housing Permissible temperatures for in zone 0: -0... 60 C with p atm 0.8 bar up to. bar environment in zone : -0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: H/m Miscellaneous Current consumption signal output current: max. 5 ma signal output voltage: max. 7 ma Weight approx. 40 g Installation position any Operational life 00 million load cycles CE-conformity EMC Directive: 04/0/EU Pressure Equipment Directive: 04/68/EU (module A) ATEX Directive 04/4/EU This directive is only valid for devices with maximum permissible overpressure > 00 bar pressure and level
DMP 5 Wiring diagrams -wire-system (current) -wire-system (voltage) p supply + p supply + VS VS supply I supply U signal + V Pin configuration Electrical connections ISO 4400 Binder 7 Mx / metal cable colour field housing (5-pin) (4-pin) (IEC 60757) Supply + Supply Signal + (only for -wire) 4 IN + IN OUT + wh (white) bn (brown) gn (green) Shield ground pin 5 4 gnye (green-yellow) Electrical connections (dimensions in mm) option ISO 4400 Binder series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP67) compact field housing (IP 67) cable outlet, cable with ventilation tube (IP 68) 4 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request : m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 4 different cable types and lengths available, permissible temperature depends on kind of cable www.bdsensors.com
DMP 5 Mechanical connections (dimensions in mm) option Accessories G/" EN 87 G/4" EN 87 /4" NPT metric threads and other versions on request Plug-on Display PA 40 Functional range free scalable display switch mode, hysteresis, parameterizable deceleration of the contacts display 0 rotatable connector 00 rotatable no external power supply necessary Product characteristics plug-on display for pressure transmitter with output signal: 4 0 ma / -wire or 0 0 V / -wire 4-digit LED display Optional versions IS-version or programmable contacts 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. DMP5_E_0098 pressure Tel. and +49 level (0) 9 5 / 98-0 www.bdsensors.com Fax +49 (0) 9 5 / 98 - info@bdsensors.de
Ordering code DMP 5 DMP 5 - - - - - - - Pressure gauge 0 Input [bar] 6 6 0 0 0 0 0 6 6 0 5 5 0 40 4 0 0 60 6 0 0 00 0 0 60 6 0 50 5 0 400 4 0 0 600 6 0 0 9 Output 4 0 ma / -wire 0 0 V / -wire intrinsic safety 4 0 ma / -wire E 9 consult Accuracy 0.5 % FSO 5 9 consult Electrical connection male and female plug ISO 4400 male plug Binder series 7 (5-pin) cable outlet with PVC cable cable outlet with cable male plug Mx (4-pin) / metal 0 0 0 0 T A 0 T R 0 M 0 compact field housing stainless steel.405 8 5 0 Mechanical connection G/" EN 87 G/4" EN 87 /4" NPT 0 0 4 0 0 N 4 0 Seals without (welded version) 9 consult Special version 0 0 0 : m PVC cable without ventilation tube (permissible temperatur: -5 70 C) cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, permissible temperature depends on kind of cable 4.0.05 05 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.