Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Similar documents
Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Technical Manual. Model 7266 Master and Model 7266 Slave

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

Industriefunkuhren. Technical Manual. LED Display 3550 (25mm / 6 Digit / 7-Seg.) ENGLISH. Version:

Technical Description

Aegis Electronic Group

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Active FCB-EV-HD-SDI INTERFACE BOARD

MICROMASTER Encoder Module

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Technical data. General specifications. Indicators/operating means

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Operating Instructions Rev. No. 4.1 July 07, LTC and VITC Reader with Serial Interface TC 60 RLV

3G/HD/SD-SDI to HDMI Converter

Single mode 9/125µm, duplex

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

ishot FCB-SE600 HD-SDI INTERFACE MODULE EM17001

I N S T R U C T I O N D A T A

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Technical Description. Large Scale Display 4985

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

SignalTap Plus System Analyzer

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

ThermalCapture GrabberUSB - User Guide

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Absolute Encoders Multiturn

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Uni700 LCD Controller

VariTime TM Digital Sync Generator, PT 5210

TABLE OF CONTENTS 1. OVERVIEW INDIVIDUAL CARD BLOCK DIAGRAMS... 2

8 Port HD/SD-SDI Switch

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

SECTION 686 VIDEO DECODER DESCRIPTION

Instruction manual for system with digital load cells MCE2035 PROFIBUS DP MODULE

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

Specifications MAV Series Matrix Switchers

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

DLP200M 2 Relay Module for Heating and Cooling Plants

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

KHT 1000C HV-Probe Calibrator. Instruction Manual

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

E3/DS3 Fibre Extender

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

HDMI 1.3 Receiver over Signal. CAT5/CAT6 Cable. Model #: HDMI-C5-R-M. 1

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

FLEX Series. Small-Scale Routing Switcher. KEY FEATURES AND BENEFITS Frame and signal. Flexible control. Communication and control.

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

DisplayPort to VGA Converter

PLEASE READ THIS PRODUCT MANUAL CAREFULLY BEFORE USING THIS PRODUCT.

Product Information. EIB 700 Series External Interface Box

Digital Input Modules for Compact FieldPoint

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Miniature Synchronous/Asynchronous Fiber Optic Modems

Rack mounted telephone- and leased line modem for industrial applications

DISTRIBUTION AMPLIFIER

Installation. Step 1 Carefully unpack the package contents.

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DS / /113. Pair (TP) User s Guide

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

3G fiber. TL7075/76 Optical 3Gbit/s Link solution with full duplex Communication Channel. TL Features. TL Features

Manual FERROFISH A16 MK-II. advanced audio applications. professional 16 channel AD/DA converter

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Style 5S Clock / Timer

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Product model and standard

DA8-T DA8-T MANUAL

DMP 331i / DMP 333i LMP 331 i


8024-DSS-02 Issue 2. DSS-8024 Dual Serial Switch USER MANUAL

KNX Dimmer RGBW - User Manual

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

Analogue output module DAO 081

High Speed Async to Sync Interface Converter

3G fiber. TL7070 3G/HD-SDI + DVI(HDMI) Fiber plus Coax Output Video Transmitter. TL Features. Block Diagram TL7070

Quick Start Guide. Wireless TV Connection with Dongle. GWHDKITD PART NO. Q1504

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Model :UVC-S100 (Universal Video Converter)

Transcription:

Industriefunkuhren Technical Manual OEM Sync-Module FE1000 (IRIG-B) ENGLISH Version: 07.02-24.03.2014

2 / 19 FE1000 IRIG-B Synchronisation - V07.02

IMPORTANT NOTES Version Number (Firmware / Manual) THE FIRST TWO DIGITS OF THE VERSION NUMBER OF THE TECHNICAL MANUAL AND THE FIRST TWO DIGITS OF THE FIRMWARE VERSION MUST COMPLY WITH EACH OTHER. THE POST DECIMAL POSITIONS OF THE VERSION NUMBER ONLY INDICATE CORRECTIONS IN THE FIRMWARE / MANUAL AND ARE OF NO SIGNIFICANCE FOR THE FUNCTION. Downloading Technical Manuals All current manuals of our products are available free of charge via our homepage on the Internet. Homepage: E-Mail: http://www.hopf.com info@hopf.com Symbols and Characters Operational Reliability Disregard may cause damages to persons or material. Functionality Disregard may impact function of system/device. Information Notes and Information. FE1000 IRIG-B Synchronisation - V07.02 3 / 19

SERVICE RELIABILITY Safety regulations The safety regulations and observance of the technical data serve to ensure trouble-free operation of the device and protection of persons and material. It is therefore of utmost importance to observe and compliance with these regulations. If these are not complied with, then no claims may be made under the terms of the warranty. No liability will be assumed for any ensuing damage. Safety of the device This device has been manufactured in accordance with the latest technological standards and approved safety regulations The device should only be put into operation by trained and qualified staff. Care must be taken that all cable connections are laid and fixed in position correctly. The device should only be operated with the voltage supply indicated on the identification label. The device should only be operated by qualified staff or employees who have received specific instruction. If a device must be opened for repair, this should only be carried out by employees with appropriate qualifications or by. Before a device is opened or a fuse is changed all power supplies must be disconnected. If there are reasons to believe that the operational safety can no longer be guaranteed the device must be taken out of service and labelled accordingly. The safety may be impaired when the device does not operate properly or if it is obviously damaged. CE Conformity This device fulfils the requirements of the EU directive 89/336/EWG "Electromagnetic compatibility" and 73/23/EWG "Low voltage equipment". Therefore the device bears the CE identification marking (CE=Communauté Européenne) CE = Communautes Europeénnes = European communities The CE indicates to the controlling bodies that the product complies with the requirements of the EU directive - especially with regard to protection of health and safety for the operator and the user - and may be released for sale within the common markets. 4 / 19 FE1000 IRIG-B Synchronisation - V07.02

TABLE OF CONTENTS Contents Page 1 General... 7 2 Informational Content of the IRIG-B / IEEE1344 / AFNOR Formats... 8 2.1 IRIG-B Formats without Year Date... 8 2.1.1 Functional Principle of Module FE1000 for IRIG-B without Year Date...8 2.2 IRIG-B / IEEE1344 / AFNOR Formats with Year Date... 9 2.2.1 Functional Principle of Module FE1000 for IRIG-B with Year Date...9 3 Design of Module FE1000... 10 3.1 Front Panel Elements of Module FE1000... 10 3.2 Overview of Module FE1000... 11 3.2.1 Jumper J1 Input level for IRIG-B Digital Signal... 11 3.2.2 DIP Switch DS1... 12 3.2.2.1 DIP Switch 1+2 / Selection of Data String for Year Date... 12 3.2.2.2 DIP Switch 3 / Year Date from IRIG-B or Clock System... 12 3.2.2.3 DIP Switch 4 / Year Date used from Memory... 12 3.2.2.4 DIP Switch 5 / Evaluation of digital or analogue IRIG-B Signal... 13 3.2.2.5 DIP Switch 6 / Currently No Function... 13 3.2.2.6 DIP Switch 7 / String Output Only in Status Sync... 13 3.2.2.7 DIP Switch 8 / String Output every second or every minute... 13 4 Commissioning... 14 4.1 Step 1: IRIG-B Input Signal ANALOGUE / DIGITAL... 14 4.2 Step 2: Year Date used from the Clock System or the IRIG-B Signal... 14 4.2.1 Extended Settings for Mode: Year provided by the Clock System... 14 4.3 Step 3: Behaviour of the Output String of Module FE1000... 15 4.3.1 Transmission Cycle EVERY SECOND/ EVERY MINUTE... 15 4.3.2 Transmission ALWAYS / ONLY IN STATUS SYNC... 15 5 Status LEDs... 16 5.1 Status LEDs Mode: Year Date from Clock System... 16 5.2 Status LEDs Mode: Year Date out of IRIG-B Signal... 16 6 Evaluable IRIG-B / IEEE1344 / AFNOR Input Signals... 17 6.1 IRIG-B according to IRIG Standard 200-98... 17 6.2 IRIG-B according to IRIG Standard 200-04... 18 6.3 IEEE 1344-1995... 18 6.4 AFNOR NF S87-500... 18 7 Technical Data... 19 FE1000 IRIG-B Synchronisation - V07.02 5 / 19

TABLE OF CONTENTS 6 / 19 FE1000 IRIG-B Synchronisation - V07.02

GENERAL 1 General The IRIG-B Module FE1000 is a compact IRIG-B converter for the integration into Clock Systems and signal converters. This module converts the time information of an externally fed IRIG-B signal (analogue/digital) into a serial string based on the hopf Master/Slave string. Furthermore, internally synchronized pulses, as PPS (pulse per second) and 1kHz frequency are put out. The module can be synchronized via different IRIG Time Code formats: IRIG-B according to IRIG Standard 200-98 (this format does not include any year date) IRIG-B according to IRIG Standard 200-04 IEEE 1344-1995 AFNOR NF S87-500 It is possible to connect both analogue and digital IRIG-B signals to the Module. In order to guarantee a successful synchronization, IRIG-B Module FE1000 requires for approx. 2-3 minutes an undisturbed signal. As the module has no internal back-up clock and in order to receive an internal time, it is required to synchronize the module after a reset or a power failure again. The according status of the module is shown by two LEDs in the front panel enabling to identify a successful or rather a disturbed synchronisation visually. The internal signal output of the time information of Module FE1000 depends on the appropriate synchronization status and also on internal settings. FE1000 IRIG-B Synchronisation - V07.02 7 / 19

INFORMATIONAL CONTENT OF THE IRIG-B / IEEE1344 / AFNOR FORMATS 2 Informational Content of the IRIG-B / IEEE1344 / AFNOR Formats Following items should be considered referring to time synchronization via an IRIG-B signal: 1. The different IRIG-B formats, as IEEE1344 and AFNOR NF S87-500 provide beside the time different information that are transferred. 2. Not all formats support the transmission of the year date which are important for a complete indication of time and date. The IRIG-B Module FE1000 can be parameterised so that the module either uses the year date provided by the fed IRIG-B signal or by the appropriate Clock System. 2.1 IRIG-B Formats without Year Date The "old" IRIB-B formats according to Standard 200-98 do not contain any information on the current year. These formats are Bxx0, Bxx1, Bxx2 and Bxx3. Using theses formats the module must be adjusted to year date provided by the Clock System. A wrong adjustment results in the use of a wrong year in the System. 2.1.1 Functional Principle of Module FE1000 for IRIG-B without Year Date 8 / 19 FE1000 IRIG-B Synchronisation - V07.02

INFORMATIONAL CONTENT OF THE IRIG-B / IEEE1344 / AFNOR FORMATS 2.2 IRIG-B / IEEE1344 / AFNOR Formats with Year Date The current IRIG Standard 200-04 has been extended by 4 formats providing the year date. These formats are Bxx4, Bxx5, Bxx6 and Bxx7. These formats include the implementation of additional information instead of the control function. The formats IEEE1344 and AFNOR NF S87-500 also include the year date necessary for synchronization. 2.2.1 Functional Principle of Module FE1000 for IRIG-B with Year Date FE1000 IRIG-B Synchronisation - V07.02 9 / 19

DESIGN OF MODULE FE1000 3 Design of Module FE1000 3.1 Front Panel Elements of Module FE1000 Status Optical Coupler 3 pole pluggable screw terminal Plug connector Pin Signal TTL Signal RS422 (Jumper J1= 1-2) (Jumper J1= 2-3) 1 TTL Input RxD+ (high-active) 2 Must remain free! RxD- (low-active) 3 GND potential free GND potential free Status LEDs LED Meaning RD GN Status LED red Status LED green IRIG-B Analogue BNC connector female IRIG-B Analogue signal input Configuration of jumper J1 for input signals at TTL level requires as a matter of necessity and for a faultless operation that Pin 2 of the connecting plug must remain free. The selection whether the digital or the analogue input signal for synchronisation is used is made via an internal DIP switch DS1. 10 / 19 FE1000 IRIG-B Synchronisation - V07.02

DESIGN OF MODULE FE1000 3.2 Overview of Module FE1000 3.2.1 Jumper J1 Input level for IRIG-B Digital Signal Via jumper J1 the selection of the digital IRIG-B signal is made. 1 2 Input signal at TTL level 2 3 Input signal at RS422 level Configuration of jumper J1 for input signals at TTL level requires as a matter of necessity and for a faultless operation that Pin 2 of the connecting plug "RIG-B Digital" must remain free. FE1000 IRIG-B Synchronisation - V07.02 11 / 19

DESIGN OF MODULE FE1000 3.2.2 DIP Switch DS1 Several settings are made by means of DIP switch DS1. 3.2.2.1 DIP Switch 1+2 / Selection of Data String for Year Date The Module FE1000 can receive the year date from different serial data strings. Only effective with DS1 SW3 = ON SW1 SW2 Function ON ON hopf Master/Slave String every second ON OFF BUS-String System 7001RC OFF ON hopf Master/Slave String every minute OFF OFF BUS-String System 6000/7001 3.2.2.2 DIP Switch 3 / Year Date from IRIG-B or Clock System Adjustment in which way the Module FE1000 receives the year date. SW3 ON OFF Function Year date used from the respective Clock System Year date used out of IRIG-B signal 3.2.2.3 DIP Switch 4 / Year Date used from Memory This function determines the reaction of the module adjusted to "year date from the Clock System" when the data string transmitted to the module does not include the required year date (for example the Clock System itself does not provide a valid time/date information). Only effective with DS1 SW3 = ON With the function "year date only used out of data string" active, synchronous status of the module is not given until the year date is received via the adjusted serial data string. With the function "year date used from memory" active, the module waits 5 minutes after switching on or reset on the adjusted data string with the year date. When the data string is not received after 5 minutes or does not include the required information, the module uses the last valid year date from the internal fail-safe memory. With the function "year date only used out of data string" active, for synchronization the user s intervention is mandatorily required in case e.g. the Clock System has no valid information on the back-up clock after a turn off of several days. SW4 ON OFF Function Year date only used out of data string Year date used from memory 12 / 19 FE1000 IRIG-B Synchronisation - V07.02

DESIGN OF MODULE FE1000 3.2.2.4 DIP Switch 5 / Evaluation of digital or analogue IRIG-B Signal Adjustment whether the IRIG-B signal input for the synchronization of the Module FE1000 is made via the analogue or digital input. SW5 ON OFF Function The analogue IRIG-B signal is evaluated The digital IRIG-B signal is evaluated 3.2.2.5 DIP Switch 6 / Currently No Function For compatibility reasons the switch should always be set to OFF SW6 ON OFF Function Currently no function Currently no function (Default) 3.2.2.6 DIP Switch 7 / String Output Only in Status Sync Adjustment whether the output of internal synchronization string should be steadily (independent of the synchronization status and availability of a valid time information) or only in status Sync. of Module FE1000. SW7 ON OFF Function Independent of the status a string is always transmitted Only in status sync. A string is transmitted (Default) 3.2.2.7 DIP Switch 8 / String Output every second or every minute The transmission cycle of the output hopf Master/Slave String can be set to every second or every minute depending on the demands of the Clock System to be synchronized. SW8 ON OFF Function String output every second String output every minute (Default) FE1000 IRIG-B Synchronisation - V07.02 13 / 19

COMMISSIONING 4 Commissioning This chapter is about commissioning of the IRIG-B Module FE1000. Usually the IRIG-B Module FE1000 is parameterized by default that only the required settings for the input IRIG-B signal needed to be executed. 4.1 Step 1: IRIG-B Input Signal ANALOGUE / DIGITAL Via the DIP-Switch DS1 the setting is made whether the IRIG-B is processed for synchronization via the analogue or digital input. 4.2 Step 2: Year Date used from the Clock System or the IRIG-B Signal Via the DIP-Switch DS1 the setting must be made whether the available IRIG-B signal necessary for the synchronization provides the required year date. 4.2.1 Extended Settings for Mode: Year provided by the Clock System With the function "year date out of Clock System" active a differentiated behaviour of the Module FE1000 for the various applications can be set. This adjustment defines whether after switching on or a RESET a valid time is available in the Clock System (for example the Clock System has no back-up clock or was off for more than 3 days). Adjustment "Year date only used out of Data String" Using this setting the Module FE1000 only becomes synchronous and thus the Clock System if the module receives a valid year date via the data string of the Clock System. If there is no valid time or date available in the Clock System the user must set a valid time for synchronisation. Adjustment "Year dated used from Memory" In this adjustment the Module FE1000 uses the last valid year date from the internal fail-safe memory for synchronisation in case the module does not receive a valid year date via the data string of the Clock System after a time period of 5 minutes after turning on or a RESET. If a wrong year should be displayed in the system using these settings the following procedure should be executed: Disconnect the IRIG-B cable from the FE1000 module Enter the needed time and date via the clock system and let the system run over the next minute change The FE1000 module needs a reset in order to take over the new time and date. Therefore the clock system has to be switched off for 5 seconds and then switched on again. Afterwards the IRIG-B cable can be re-connected to the FE1000 module 14 / 19 FE1000 IRIG-B Synchronisation - V07.02

COMMISSIONING 4.3 Step 3: Behaviour of the Output String of Module FE1000 The behaviour of the internal output of the synchronization (hopf Master/Slave String) can be set via DIP switch DS1. 4.3.1 Transmission Cycle EVERY SECOND/ EVERY MINUTE The transmission cycle of the output hopf Master/Slave String can be set to every second or every minute depending on the demands of the Clock Systems to be synchronized. 4.3.2 Transmission ALWAYS / ONLY IN STATUS SYNC This adjustment determines whether the connected Clock System is synchronized as soon as there is a valid time information available in Module FE1000 or only while the Module FE1000 is synchronized via the IRIG-B signal. FE1000 IRIG-B Synchronisation - V07.02 15 / 19

STATUS LEDS 5 Status LEDs For a better failure analysis the Status LEDs show a different behaviour in the two general operation modes (year date from Clock System / year date out of IRIG-B signal). 5.1 Status LEDs Mode: Year Date from Clock System The Status LEDs on the front panel indicate the current (synchronization) status of the board. The LEDs have the following meaning: LED Red LED Green Status OFF ON Sync (radio synchronous) with crystal control ON 1Hz Year available + no input signal 2Hz 1Hz Year available + signal not evaluable / not yet evaluated 5Hz 1Hz No year available + input signal OK ON OFF No year available + no input signal 5.2 Status LEDs Mode: Year Date out of IRIG-B Signal The Status LEDs on the front panel indicate the current (synchronization) status of the board. The LEDs have the following meaning: LED Red LED Green Status OFF ON Sync (radio synchronous) with crystal control 5Hz OFF no input signal 2Hz OFF signal not evaluable / not yet evaluated 16 / 19 FE1000 IRIG-B Synchronisation - V07.02

EVALUABLE IRIG-B / IEEE1344 / AFNOR INPUT SIGNALS 6 Evaluable IRIG-B / IEEE1344 / AFNOR Input Signals The following telegrams / Time Code formats can be evaluated by Module FE1000: IRIG-B according to IRIG Standard 200-98 IRIG-B according to IRIG Standard 200-04 IEEE 1344-1995 AFNOR NF S87-500 Analogue Signals (for example IRIG-B 12x): Modulation depth 3:1 Voltage level 1-10 Vpp Digital Signals (for example IRIG-B 00x): optionally RS422 level or TTL level 6.1 IRIG-B according to IRIG Standard 200-98 The IRIG-B format consists of a time code of 74 bits and a repeat rate of one second. The bit frame is 10msec. The quality rating of a bit is marked by the pulse width modulation and is a multiple of a millisecond. For synchronisation on the beginning of the second a neutral logical condition is required named identifier. Logical 0 = 2msec H-level Logical 1 = 5msec H-level Identifier = 8msec H-level The 74 time code bits are divided into 30 bits for the BCD value of the seconds, minutes and hours and the current day of the year 27 bits for the input of control information 17 bits for the binary value of the current seconds of the day Within one second 100 bit frames can be transferred. Not used bit frames are completed with a logical zero. Information referring to the year, difference time UTC to local time and status daylight saving time / winter time are not included in the telegram according to IRIG Standard 200-98. FE1000 IRIG-B Synchronisation - V07.02 17 / 19

EVALUABLE IRIG-B / IEEE1344 / AFNOR INPUT SIGNALS The below drawing shows the IRIG-B signal quality rating in analogue and digital format. position identifier reference bit low high 8ms 8ms 2msec 5msec IRIG-B analog IRIG-B digital PPS 6.2 IRIG-B according to IRIG Standard 200-04 The IRIG-B Standard 200-04 is an extension of the Standard 200-98. Additional IRIG telegrams with extended information were defined. For example, the current year is additionally sent in the first control information field. That enables the issue of a complete time/date information. 6.3 IEEE 1344-1995 This version of the IRIG Standard is an extension of the IRIG Standard 200-98. The 27 bits of the control information field are occupied with fixed data as year, time offset between UTC and local time, daylight saving time / winter time status etc. It is downward compatible to Standard 200-98 (the IRIG Standard 200-98 is included as a subset). 6.4 AFNOR NF S87-500 This IRIG standard is issued by the French Institute of Engineering Standard and is built up on the Standard IRIG 200-98 auf. 27 bits of the control information field are occupied with fixed data as year, month etc. It is downward compatible to Standard 200-98 (the IRIG Standard 200-98 is included as a subset). 18 / 19 FE1000 IRIG-B Synchronisation - V07.02

TECHNICAL DATA 7 Technical Data General Data Operating voltage: 5V DC ± 5% Temperature: -20... +85 C / 0... +70 C Storage / Operating Humidity: 95%, not condensed Standards: CE Protection class: none MTBF: > 900,000 hours Conversion accuracy: Analogue-Signal: Digital-Signal: Freewheel Stability: 20 sec, Jitter 5 sec 3 sec 0.2ppm to input signal after 0.5 hours of continuous IRIG-B signal reception Signal Inputs IRIG-B analogue: Potential separation 500V DC Impedance: 10kOhm Voltage level: 1-10Vpp Degree of modulation: 3 : 1 IRIG-B digital: Potential separation 500V DC Voltage level: RS422, TTL-level Automatic recognition of high- and low-active signals IRIG Format: - IRIG-B according to IRIG Standard 200-98 - IRIG-B according to IRIG Standard 200-04 - IEEE1344-1955 - AFNOR NFS 87-500 With automatic format recognition Internal Serial Interface: TTL-level Signal Outputs: PPS-Pulse: Pulse width: 1kHz-Signal: Serial interface: TTL-level high-active 50msec TTL-level 50/50 low-active TTL-level low-active FE1000 IRIG-B Synchronisation - V07.02 19 / 19