Introduction Edison Opto advanced a variety of AC modules, such as ceiling light module and down light module. With reference to the property, these Modules have been driven by AC power, so that products are not external drivers needed. Therefore, the power cost and volume of the lamp is significantly reduced by the design of AC Modules and makes design flexibility with AC source lighting. EdiLex AC Series EdiLex 120V AC Module G2 series Datasheet Features Connects directly to AC line voltage High Power Efficiency & Factor Long Life Time Miniaturization 3-Step MacAdam Applications Down Light Wall Light Ceiling Light Pendent Light Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 1
Table of Contents Product Nomenclature...3 Electro-Optical Characteristics (Ta=25 C)...4 Absolute Maximum Ratings...6 Mechanical Dimensions...7 Color BIN code...11 Characteristic curve...13 Caution...16 Environmental Compliance...16 Revision History...17 About Edison Opto...17 Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 2
Product Nomenclature 5 ELA C I 2T xx xx xx xx X1 X2-X4 X5 X6 X7-X8 X9-X10 X11-X12 X13-X14 X15-X16 X1 Item X2-X4 Module Application X5 Dimensions X6 IC X7-X8 LED Item X9-X10 Voltage 5 Module ELA EdiLex AC C Circle - - 2T PLCC 12 120V 23 230V X11-X12 Emitter Power X13-X14 Emitting color X15-X16 Serial Number 05 5W 57 5700K - - 10 10W 40 4000K 15 15W 30 3000K 20 20W 25 25W Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 3
Electro-Optical Characteristics (Ta=25 C) Non-Dimmable Series Electro-Optical Characteristics (Tc=25 C) Parameter Symbol Value Unit Input Voltage V in 120 Vac Operating Frequency f 50/60 Hz Power Factor PF 5W/10W/15W > 0.90 20W/25W > 0.95 Viewing Angle 2θ 1/2 120 deg. Tolerance of Surge V S 5W/10W/15W: >500 20W/25W: >1000 - V Typ. Power Dissipation (W) Order Code Typ. CCT (K) Typ. Luminous Flux (lm) Min. CRI Dimension (mm) 5ELACI2T12055701 5700 440 5 5ELACI2T12054001 4000 420 38 5ELACI2T12053001 3000 400 5ELACI2T12105701 5700 1000 10 5ELACI2T12104001 4000 950 50 5ELACI2T12103001 3000 900 5ELACI2T12155701 5700 1450 15 5ELACI2T12154001 4000 1350 80 70 5ELACI2T12153001 3000 1250 5ELACI2T12205701 5700 2050 20 5ELACI2T12204001 4000 1950 100 5ELACI2T12203001 3000 1850 5ELACI2T12255701 5700 2450 25 5ELACI2T12254001 4000 2350 125 5ELACI2T12253001 3000 2250 Notes: 1. Luminous flux and power consumption are measured at 120Vac, Tc=25 C 2. Luminous flux has 10% tolerance. 3. Power consumption has 10% tolerance. 4. The hot-cold factor of Tc=25 C and Tc=65 C is 0.9. 5. Surge withstand in accordance with IEC6100-4-5. Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 4
Dimmable Series Electro-Optical Characteristics (Tc=25 C) Parameter Symbol Value Unit Input Voltage V in 120 Vac Operating Frequency f 50/60 Hz Power Factor PF >0.95 - Viewing Angle 2θ 1/2 120 deg. Tolerance of Surge V S 10W: >500 15W/20W/25W: >1000 V Typ. Power Dissipation (W) Order Code Typ. CCT (K) Typ. Luminous Flux (lm) Min. CRI Dimension (mm) 5ELACI2T12105702 5700 1050 10 15 5ELACI2T12104002 4000 1000 5ELACI2T12103002 3000 950 5ELACI2T12155702 5700 1600 5ELACI2T12154002 4000 1500 70 100 5ELACI2T12153002 3000 1450 5ELACI2T12205702 5700 2100 80 20 25 5ELACI2T12204002 4000 2000 5ELACI2T12203002 3000 1900 5ELACI2T12255702 5700 2550 5ELACI2T12254002 4000 2450 5ELACI2T12253002 3000 2350 125 145 Notes: 1. Luminous flux and power consumption are measured at 120Vac, Tc=25 C 2. Luminous flux has 10% tolerance. 3. Power consumption has 10% tolerance. 4. The hot-cold factor of Tc=25 C and Tc=65 C is 0.9. 5. Surge withstand in accordance with IEC6100-4-5. Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 5
Absolute Maximum Ratings Parameter Symbol Value Unit Input Voltage V in 140 Vac Operating Temperature T opr -30 ~ 85 Storage Temperature T stg -40 ~ 100 o C o C ESD Sensitivity (HBM) - ±4,000 Volt LED Juntion temperature T J 125 Thermal Measurement Point T c 70 o C o C Notes: 1. Input Voltage doesn t indicate the maximum voltage which customers use but means tolerable voltage according to each country s voltage variation rate. It is recommended that the thermal measurement point temperature(t c ) should be below 70 C. 2. The Tc is recommended under 70 C while operating temperature is between -35 C ~ 85 C. Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 6
ZD J1 J1 U2 ZD AC_L R4 BD U2 R2 R3 R6 R2 L18 L17 L7 L8 R3 R5 R5 L9 R4 L16 L22 L4 L6 L15 L3 FUSE D1 L14 L5 U1 L2 L1 L1 L13 Tc L5 R6 BD R1 L11 R1 L6 L1 Tc L13 L7 L4 L2 Tc L7 L14 FUSE U2 L3 U4 L2 L12 L10 L22 R2 R4 AC_N FUSE L9 L5 L8 L8 L21 Q1 L17 L3 L4 BD L9 AC_N D2 L18 U5 U3 RS1 R5 RS2 R3 Q0 D0 RS0 R7 R6 J1 U0 ZD Mechanical Dimensions 5ELACI2T1205xx01 (5W_No Dimming) Tc point U1 R1 L10 AC_L 4.2 5ELACI2T1210xx01 (10W_No Dimming) Tc point L19 L10 L20 L11 L21 U1 AC_L AC 120V_10W_2 S_ STD1 4.3 5ELACI2T1210xx02 (10W_Uniform Dimming) AC 120V_10W_2S_STD2 L6 L12 L16 L15 L20 AC_N Tc point 4.3 Notes: 1. All dimensions are in millimeters. 2. Tolerance: ±0.2mm Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 7
R6 L18 L1 R2 U2 R2_1 U3 L16 L2 AC 120V_15W 2S_STD2 L22 Q1 J1 L3 R1 R4 L9 Tc L15 L4 BD L14 L5 L7 L6 L13 L12 5ELACI2T1215xx01 (15W_No Dimming) Tc point R3 L17 ZD FUSE L21 AC_L AC_N L19 L8 L11 L20 L10 4.3 5ELACI2T1215xx02 (15W_Uniform Dimming) 4.3 Notes: 1. All dimensions are in millimeters. 2. Tolerance: ±0.2mm Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 8
5ELACI2T1220xx01 (20W_No Dimming) 4.3 5ELACI2T1220xx02 (20W_Uniform Dimming) 4.3 Notes: 1. All dimensions are in millimeters. 2. Tolerance: ±0.2mm Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 9
5ELACI2T1225xx01 (25W_No Dimming) 4.2 5ELACI2T1225xx02 (25W_Uniform Dimming) Notes: 1. All dimensions are in millimeters. 2. Tolerance: ±0.2mm 4.3 Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 10
Color BIN code Color region stay within Macadam "3-Step" ellipse from the chromaticity center. The chromaticity center refers to ANSI C78.377:2008. Please refer to ANSI C78.377 for the chromaticity center. CCT Steps Cx Cy a b theta 3000K 3 0.4338 0.4030 0.00834 0.00408 53.22 4000K 3 0.3818 0.3797 0.00939 0.00402 53.72 5700K 3 0.3287 0.3417 0.00746 0.00320 59.09 Cool White 0.40 0.38 0.36 CIE-y 0.34 573 0.32 0.30 0.28 0.29 0.30 0.31 0.32 0.33 0.34 0.35 0.36 CIE-x Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 11
Neutral White 0.44 0.42 0.40 CIE-y 0.38 403 0.36 0.34 0.32 0.355 0.365 0.375 0.385 0.395 0.405 CIE-x Warm White 0.44 0.42 0.40 303 CIE-y 0.38 0.36 0.34 0.38 0.4 0.42 0.44 0.46 0.48 0.5 CIE-x Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 12
Characteristic curve Color Spectrum 1.2 Relative luminous Intensity 1.0 0.8 0.6 0.4 0.2 Cool White Neutral White Warm White 0 400 500 600 700 800 Wavelength(nm) Color Spectrum at a typical CCT for EdiLex 120V AC Module G2 5W 1.2 Relative luminous Intensity 1.0 0.8 0.6 0.4 0.2 Cool White Neutral White Warm White 0 400 500 600 700 800 Wavelength(nm) Color Spectrum at a typical CCT for EdiLex 120V AC Module G2 10W/15W/20W/25W Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 13
Beam Pattern Normalized Relative Intensity 1.0 0.5 Ta=25 C 0 10 20 30 40 50 60 70 80 0-90 -60-30 0 Radiation Angle 0.5 Beam pattern diagram for EdiLex 120V AC Module G2 1.0 90 Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 14
Relative Power Distribution vs. Voltage 1.2 1.1 Relative Power (%) 1.0 0.9 0.8 0.7 0.6 108 114 120 126 132 Voltage [RMS,V] Relative Power Distribution vs. Voltage for EdiLex 120V AC Module G2 Relative Luminous flux vs. Voltage 1.2 1.1 Relative Luminous Flux 1.0 0.9 0.8 0.7 0.6 108 114 120 126 132 Voltage[RMS,V] Relative Luminous flux vs. Voltage for EdiLex 120V AC Module G2 Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 15
Caution 1. Please note that EdiLex AC Module products are driven by high voltage, therefore when operating EdiLex AC Modules should be very cautious. 2. DO NOT touch the circuit board, components or terminals with body or metal while the circuit is active. 3. DO NOT add or change wires while the circuit of AC Module is active. 4. Long time exposure to sunlight or UV should be avoided; otherwise, it may cause the discoloration of lens. 5. DO NOT use adhesives to attach the LED that outgas organic vapor. 6. DO NOT use the products with materials containing Sulfur. 7. DO NOT assemble in humid environment or the conditions of containing oxidizing gas such as Cl, H2S, NH3, SO2, NOX, etc. 8. DO NOT make any modifications on the products. 9. EdiLex AC Module uses integrated circuit (IC) which can be damaged when exposed to static electricity. Please operate with antistatic device. Do not touch the product unless ESD protection is used. EdiLex AC Module can t be installed in end product unless the ESD protection is used. 10. DO NOT press the product; even a slight pressure may damage the product. The environments such as high temperatures, high humidity or direct expose to sunlight should be avoided since the product is sensitive to these conditions. 11. Storage Precautions: (1) The devices should be stored in the anti-static bag. (2) If the anti-static bag has been opened, please make sure to reseal the bag to avoid air and moisture infiltrate in the bag. 12. It is strongly suggested to wear rubber insulated gloves and rubber bottom shoes while operating the AC Modules. 13. DO NOT wear any conductive accessories (such as jewelry) which could accidentally get an electric shock. 14. Faults, lightning, or fast switch may cause voltage surge which surpasses the normal value. 15. The failure of internal component may cause excessive voltages. Environmental Compliance AC module series are compliant to the Restriction of Hazardous Substances Directive or RoHS. The restricted materials including lead, mercury cadmium hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated diphenyl ether (PBDE) are not used in AC module series to provide an environmentally friendly product to the customers. Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 16
Revision History Versions Description Release Date 1 Establish order code information 2014/12/12 2 1. Update characteristic curve 2. Add Color Bin 3. Revise mechanical dimensions 2015/05/04 About Edison Opto Edison Opto is a leading manufacturer of high power LED and a solution provider experienced in LDMS. LDMS is an integrated program derived from the four essential technologies in LED lighting applications- Thermal Management, Electrical Scheme, Mechanical Refinement, Optical Optimization, to provide customer with various LED components and modules. More Information about the company and our products can be found at Copyright 2015 Edison Opto. All rights reserved. No part of publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photo copy, recording or any other information storage and retrieval system, without prior permission in writing from the publisher. The information in this publication are subject to change without notice. For general assistance please contact: service@edison-opto.com.tw For technical assistance please contact: LED.Detective@edison-opto.com.tw Copyright 2015 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2 17