LED MODULES READYLINE DL

Similar documents
LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LED control gear Compact fixed output

LED Driver Compact dimming

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

Preliminary Data sheet

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Emergency lighting units EM powerled

LED Driver Compact fixed output

Benefits. Applications

Specification. EdiLex AC UFO Module 230V Series Datasheet 5ELACN2T23A ELACN2T23A ELACN2T23B Drawn Approval Approval

R xx-C0900-J074

Emergency lighting units EM powerled

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Features. High Brightness SMD LED Light source

LUXPOINT TM MIDI 6 LED Downlight Data Sheet

Technical Information

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Specification. EdiLex AC Ultra-Low Flicker Module 230V Datasheet. Drawn Approval Approval

Federal 3535 FX-C White Datasheet

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

LED Driver Constant voltage

PLCC W 2 Series IEC White Datasheet

L xxx-C0720-K255

LED Driver Compact dimming

R Rxx-Vxxxx-L334-x

Indoor Linear 80W Driver SI-C215280N2KR

LED Driver Linear / area dimming

17W AR111 Module Datasheet

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Bulb Down Light Decorative Light

PLCC 2835 HE Series Datasheet

Guidelines for Specification of LED Lighting Products 2010

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Compact dimming

3528 1W 3 Series White

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED

W LC Datasheet

PLCC S Series W 9V

PLCC W 6000K Series Datasheet

OT 100/ /700 P5

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

EdiLex 120V AC Module G2 series Datasheet

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application:

PLCC Series 5630B HE High CRI

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

PLCC Series 2835 SE PCT

architecture mounting Features Product lighting

PLCC Series W. Datasheet. Introduction : Feature and Benefits : Description : PLCC Series

V. PLCC Series. Datasheet. Introduction : Description : Feature and Benefits : PLCC Series

PLCC W CRI K Datasheet

SubstiTUBE Advanced ST8-HA4

PLCC W LC CRI80 Datasheet

3528 1W 2 Series White (IP)

PLCC W CRI90 Datasheet

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Operating instructions

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

FLUID VIEW 12V LED TAPE LIGHT

E-CORE GLS WIDE 7W E-CORE GLS WIDE 10W. Data Sheet 1 / 5

PLCC W CRI 80 Datasheet

Gamma instabus. Technical product information

EdiLine III Series Datasheet

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

OPTOTRONIC Intelligent

ET-5050x-BF1W Datasheet

Coreline Malaga LED BRP101/102. Time for Coreline Malaga LED

SubstiTUBE Value EM ST8V-1.2m-17W-EM

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SubstiTUBE Value EM Fighter Tube Technical Datasheet

LUXFLEX PREMIUM THIN & FLEXIBLE BACKLIGHTING. Indoor/Outdoor Series

LEDVANCE DOWNLIGHT LED

LED bar- Built-in constant current - 105Lm/W-thin 5.5mm-waterproof

SubstiTUBE Value ST8-HV5

PLCC 5630B 0.5W High CRI Datasheet

LUXFLEX FLEXIBLE, COLORFUL BACKLIGHTING

LED Driver Compact dimming

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

Caveled Tunnel Lighting Series. SL-Caveled/100277AC (UL) - B Type - UL certified (E326344) Features. Typical Applications.

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

QTi DALI 2X14/24/ DIM

HE Series. EdiPower III. Datasheet

DOB Series C EdiPower III. Datasheet. Introduction :

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

PLCC Series EMC 3030 Single color

LED STADIUM LIGHTING WS-STAD-xxx Gen6

SubstiTUBE Value ST8V-0.6m

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

High / Low Bay Datasheet

Type: DILM25 10(24V50HZ) Article No.:

TRF STEP-DOWN TRANSFORMER USER MANUAL

LUXFLEX STANDARD THIN & FLEXIBLE BACKLIGHTING. Indoor Series

ClearWay economical LED performance

Technical operating data

Operating Instructions Dimmer for V Incandescent Lamps

DOB Series PHI33. EdiPower III. Dim to Warm 230V Datasheet. Introduction :

Transcription:

LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH POWER FACTOR HIGHLY EFFICIENT LES PROTECTION COVER FOR A SAFE LUMINAIRE APPROVED TO EUROPEAN STANDARDS VDE APPROVED

LED Modules ReadyLine DL Technical Notes LED built-in module for integration into luminaires AC operation at 230 V Power factor: 0.99 Dimensions WU-M-538: Ø 164 mm WU-M-539: Ø 250 mm WU-M-540: Ø 350 mm Beam angle: 120 ReadyLine DL EM for Emergency Lighting With separate LED circuit for operation with local VS emergency lighting drivers Typical Light Distribution Curve Electrical Characteristics at tp = 50 C / 230 V AC Type Supply voltage AC Operation frequency Power consumption THD Power Flicker percent Flicker index Utyp. / Uoperation at 230 V factor V Hz W % % WU-M-538 220 240 50/60 20.5 12 0.99 18 0.05 WU-M-539 30.5 12 0.99 16 0.05 WU-M-540 42.5 13 0.99 14 0.04 Maximum Ratings Exceeding the maximum ratings can lead to reduction of service life or destruction of the modules. Type Operation voltage range (AC) Operation temperature range at tc point Ambient temperature range Storage temperature range U min. U max. C min. C max. C min. C max. C min. C max. All types 205 264 20 +80 20 +45 40 +85 Optical Characteristics at tp = 50 C / 230 V AC LED-Module_ReadyLine_DL_WU-M-538-539-540_EN 2/6 03/2017 Typ. Type Ref. No. Type Ref. No. Number Colour Correlated Typ. luminous flux (lm) and Typ. Energy output EM* EM* of LEDs colour efficiency (lm/w)** at 230 V CRI efficiency W pcs. temperature (K) min. (lm) typ. (lm) typ. (lm/w) Ra ReadyLine DL 164 ReadyLine DL 164 EM 20.5 WU-M-538-830 562159 WU-M-538-830-EM 561880 46 warm white 3000 2184 2237 113 80 A+ 20.5 WU-M-538-840 562160 WU-M-538-840-EM 561881 46 neutral white 4000 2184 2350 119 80 A+ 20.5 WU-M-538-850 562161 WU-M-538-850-EM 562162 46 cool white 5000 2184 2429 123 80 A+ ReadyLine DL 250 ReadyLine DL 250 EM 30.5 WU-M-539-830 562163 WU-M-539-830-EM 561882 90 warm white 3000 3172 3503 112 80 A+ 30.5 WU-M-539-840 562164 WU-M-539-840-EM 561883 90 neutral white 4000 3172 3617 116 80 A+ 30.5 WU-M-539-850 562165 WU-M-539-850-EM 562166 90 cool white 5000 3457 3743 120 80 A+ ReadyLine DL 350 ReadyLine DL 350 EM 42.5 WU-M-540-830 562167 WU-M-540-830-EM 562170 89 warm white 3000 4143 4663 110 80 A+ 42.5 WU-M-540-840 562168 WU-M-540-840-EM 562171 89 neutral white 4000 4321 4841 114 80 A+ 42.5 WU-M-540-850 562169 WU-M-540-850-EM 562172 89 cool white 5000 4499 5019 118 80 A+ * With separate LED circuit for operation with local VS emergency lighting drivers only ** Production tolerance of luminous flux and efficiency: ±10% Packaging unit: 64 pcs. (DL 164) / 22 pcs. (DL 250) / 16 pcs. (DL 350) 2

Optical Characteristics for Emergency Lighting Operation Typ. Type Ref. No. Number Typ. Typ. Typ. Output of LEDs luminous flux* voltage* current* W pcs. lm DC (V) ma ReadyLine DL 164 EM 3 WU-M-538-830-EM 561880 6 535 36 100 3 WU-M-538-840-EM 561881 6 560 36 100 3 WU-M-538-850-EM 562162 6 580 36 100 ReadyLine DL 250 EM 3 WU-M-539-830-EM 561882 8 425 25 125 3 WU-M-539-840-EM 561883 8 440 25 125 3 WU-M-539-850-EM 562166 8 475 25 125 ReadyLine DL 350 EM 3 WU-M-540-830-EM 562170 8 435 25 125 3 WU-M-540-840-EM 562171 8 455 25 125 3 WU-M-540-850-EM 562172 8 500 25 125 * Production tolerance of luminous flux, voltage and current: ±10% Operating Life Lumen maintenance L70/B50: 50,000 hrs. at t p 65 C Mechanical Dimensions WU-M-539 WU-M-538 LED-Module_ReadyLine_DL_WU-M-538-539-540_EN 3/6 03/2017 3

Mechanical Dimensions WU-M-540 LED-Module_ReadyLine_DL_WU-M-538-539-540_EN 4/6 03/2017 4

LED Modules ReadyLine DL Covers for ReadyLine DL modules Material: PC, transparent or opaque Max. torque: 1 Nm Ref. No. For Ø Height Mounting Max. Ø transparent opaque LED module A (mm) B (mm) distance of PCB C (mm) D (mm) 563858 565066 WU-M-538 168.5 21.7 92 158.4 563859 565067 WU-M-539 255.5 22.2 111.7 244.2 563860 565068 WU-M-540 355.5 22.7 152 340.5 Packaging unit: 64 pcs. (WU-M-538) / 22 pcs. (WU-M-539) / 16 pcs. (WU-M-540) Assembly and Safety Information LED-Module_ReadyLine_DL_WU-M-538-539-540_EN 5/6 03/2017 The LED modules are designed for direct mains operation (230 V AC). Installation must be carried out under observation country specific relevant safety regulations and standards. The LED module is a built-in lighting module to assemble into luminaires. Suitable for luminaires of protection class I, grounding is mandatory to comply with safety standards. Vossloh-Schwabe recommends to use the cover (Ref. No. 563858, 563859, 563860), in order to comply with applicable safety regulations. In case of applications in luminaires of protection class II the safety regulations acc. to luminaire safety standards must be observed. Vossloh-Schwabe recommends to use the modules ReadyLine DL EM -Module with VS Emergency Lighting units (Ref. No. 186495, 186498). Operation of the LED module is not allowed when it is not built-in into a luminaire. Depending on application, luminaire application specific safety standards have to be observed (e.g. EN 60598 for Europe). Depending on the use of the luminaire in different countries (export), the country specific safety standards have to be regarded (e.g. EN 60598 for Europe). Regard to sufficient isolation acc. country specific standards. Live parts must not be touched. Luminaire must be closed acc. country specific standards. Danger of life!!! Clearance and creepage distances of the module are designed for class I luminaires (basic insulation). For built-in of the module the required standards have to be observed (e.g. EN 60598). Do not exceed values given in this specification. Do not exceed max tc temperature of 80 C. The module must be fixed onto a thermally conductive surface. Heat sink must cover the entire backside surface of the module. For the operation of WU-M-540 VS recommends to mount the module directly onto the metal heat sink or luminaire housing is mandatory to comply with immunity standards (e.g. EN 61547). When installing/screwing the module into a luminaire, please ensure that cables are not squeezed between luminaire/heat-sink and LED module. Please ensure standard ESD (electrostatic discharge) protection measures are employed when handling and installing LED modules. Electrostatic discharge can damage LEDs. The LED modules are connected via two on board push-in connectors for flexible or solid conductors. Conductor section AWG24 18: Flexible, tinned: 0.25 0.75 mm² Solid: 0.5 0.75 mm² Strip length: 7 9 mm The flexible cable has to be tinned. The contacts can be released with a flat-headed screwdriver with a width of 3 mm. It has to be ensured, that the used cables do not decrease clearance and creepage distance of the modules. The cable must be put in completely (as far as isolation will go) into terminal. Used cables must fulfil luminaire safety standards (EN 60598). Other country specific standards have to be regarded. 5

Parallel connection is mandatory for safe electrical operation. Serial connection of LED modules is not allowed. Due to the used electronic parts on the module not all available phase-cutting dimmers are compatible. Dimmable with phasecutting leading- and trailing-edge dimmer. Minimum dimmer load has to be observed. The compatibility of the dimmer and the modules has to be confirmed prior to installation to avoide flickering. To ensure problem-free operation, the specified maximum temperature at the tc point (see "Operating Life") must be observed (measured in accordance with EN 60598-1). To satisfy this point, it is necessary to put measures in place to ensure any heat is dissipated from the LED module to the environment. In the event of outdoor applications or applications in damp locations, care must be taken to protect LED assembly modules against humidity, splashes and jets of water. Any corrosion damage resulting from humidity or contact with condensation will not be recognised as a defect or manufacturing fault. LED assembly modules are not specially protected against foreign bodies or dust. Depending on the type of application, further protection must be ensured to prevent dust and foreign bodies from entering. Relevant country and application specific standards have to be regarded. Installation by qualified electrician only Do not add or change wires while circuit is active Do not make modifications on module Do not use adhesives to attach that outgas organic vapour Do not use togehter with material containing sulfur Do not operate module with AC generators Do not operate modules by DC LED modules must not be subjected to any undue mechanical stress, e. g.: LED module handle modules carefully avoid shear and compressive forces onto the modules during handling and installation avoid vibrations of more than 2 khz, 40 G If module is used in rooms with fast moving parts as the light modulation might cause stroboscopic effects. This LED module might interfere with displays and cameras due to modulation. The photobiological safety of the LED modules is classified into risk groups in accordance with EN 62471: 2008 and IEC TR 62778: risk group 1 Applied Standards EN 62031 LED modules for general lighting Safety specifications EN 62471 Photobiological safety of lamps and lamp systems EN 55015 Radio disturbance emissions EN 61000-3-2 Limits for harmonic emissions EN 61547 Immunity requirements Product Guarantee 5 years The conditions for the Product Guarantee of the Vossloh-Schwabe Group shall apply as published on our homepage (www.vossloh-schwabe.com). We will be happy to send you these conditions upon request. LED-Module_ReadyLine_DL_WU-M-538-539-540_EN 6/6 03/2017 6