3GHD-EO-D15xx. User manual

Similar documents
3GHD-EO-SFP. User manual. SD/HD/3G-SDI electrical to optical converter with SFP. Rev. A

3GHD-EO-2-SFP. User manual. Dual SD/HD/3G-SDI electrical to optical converter with SFP. Rev. C

Dual HD-SDI Electrical to Optical Converter

DA-SDI-NRC. User manual. SDI Distribution Amplifier Non-Reclocking version. Rev. E

DA-AES. AES distribution amplifier. User manual. Rev. 8

3GHD-OE 3GHD-OE-2. User manual. Single and dual 3G-SDI optical to electrical converter. Rev. F

RS-422 Data Transceiver Supports CWDM

HDSDI-CHO-2x1 HD-SDI-CHO-2x1-PB

Multi Rate Transponder and Converter for 1330 /1550nm and Coarse Wavelength Division Multiplexing. Flashlink User Manual

ETH1000-SFP. User manual. Gigabit Ethernet Media Converter. Rev. A. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

DAC-AES. DAC-AES Audio Converter. User manual. Rev. 7

DWDM-8C / DWDM-8C-MkII

ADC-AES. ADC-AES Audio Converter card. User manual. Rev. 5

LB-EO. User manual. L-BAND Electrical to Optical Converter. Rev. F. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

Analogue audio embedder

Analogue audio de-embedder

3GHD-CHO-2x4/2x3. User manual

SD-SDI LINE SYNCHRONIZER

AAV-HD-DMUX(-R)/ AAV-SD-DMUX(-R)

AD6464M / AD128128M. User manual

3G-IP-MUX-8-SFP. User manual. 8 channel bi-directional 3G/HD/SD Video over IP multiplexer/de-multiplexer. Rev. A

A3232M / A6464M / A128128M A3232S / A6464S

AAV-HD-XMUX(-T/R)/ AAV-SD-XMUX(-T/R)

AV-HD-XMUX (-T/R) / AV-SD-XMUX (-T/R)

SLX2-3GHD3232-CP Sublime X 2 hybrid router

3GHD256256L / SD256256L. User manual

FRS-3G-DUAL. User manual. Dual Frame Synchronizer for 3G/HD/SD-SDI. Rev. A (Preliminary)

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

AV-3G-XMUX User Manual

User Manual AES-MUX. Multichannel digital audio to fibre.

SDI-TD-3GMX-5 / SDI-TD-3GDX-5 HD-TD-3GMX-2 / HD-TD-3GDX-2

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

FiberLink 3350 Series

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

FiberLink 3500 Series Transceivers

INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

PGM-HD-2x1-PB. User manual. HD/SD-SDI 2x1 Program Switch with Frame Synchronizer. Rev. B

Doteck 4K Series. 6G-SDI UHD Video fiber optic Transmission System

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS...

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

6G-SDI. Digital Video fiber. optic Transmission System

EZ-S Owner s Manual. 3G-SDI Over Fiber Extension System

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

2302 & 2304 Series. Copperlink. 3G/HD/SD-SDI Distribution Amplifier. User s Manual. Communications Specialties Copperlink 2302 & 2304

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

I N S T R U C T I O N D A T A

SilverBULLET 3G Series

opengear OPG-1L 50 MHz-2.3 GHz

Analog HD video over fiber converters for smart HD CCTV

12G/6G/3G/HD/SD-SDI over Single mode SFP-type Fiber Optic Extender Immune to Pathological. User Manual. rev: Made in Taiwan

The Art of Engineering

3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 video router ALL RIGHTS RESERVED

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Product Catalog. Route - Transport - Extend - Convert - Scale. Multimedia Products for HDMI and DVI. 3G sdi OCT-2010-C

Product Operation Manual

TABLE OF CONTENTS 1. OVERVIEW INDIVIDUAL CARD BLOCK DIAGRAMS... 2

FiberLink 3355 Series

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

THE ART OF ENGINEERING

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

1310nm Video SFP Optical Transceiver

PRODUCT BRIEF Copper to Fiber Media Converter 4-Channel SMPTE HD/3G-SDI

H5000 Outdoor Mini Virtual HUB

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

HDCVI Video Converter. User s Manual V1.0.0

FLEX Series. Small-Scale Routing Switcher. KEY FEATURES AND BENEFITS Frame and signal. Flexible control. Communication and control.

PSC UHF Log Periodic Antenna

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

2015 OPTICAL TRANSMITTERS

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

HDB

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

10Gbps 10km Range SFP+ Optical Transceiver

Headend Optics Platform (CH3000)

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: 690T SDI Fiber Optic Transmitter 690R SDI Fiber Optic Receiver. P/N: Rev 2

Product Specification. 10Gb/s, 10km XFP Optical Transceiver FTLX1413M3BCL

DVM-150E Professional DTV Receiver/Decoder

Medallion 7100 Series CATV Fiber Amplifier

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

Dual channel HD/SD integrity checking probe with clean switch over function and wings or split screen creation capabilities

COPYRIGHT 2011 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

User Instruction Manual IQOTR31. 3G/HD/SD-SDI Single Mode Fiber Optic Transceiver. snellgroup.com

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

High Performance fibre systems

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

White Paper Lower Costs in Broadcasting Applications With Integration Using FPGAs

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

FIBER FIRST. opengear OG3600 Series. Fiber Transport Cards User Manual. Fiber Optic Solutions. Creating Broadcast & Cinema Equipment since 1977

PL7330T / PL7330R16 RF Link High Power Input, 16dB Optical Budget 45Km nm or 70Km nm

1550 nm / 3 Gb/s Medium Power Single Optical SM Digital Diagnostic Transmitter FVD2-1TR-SM50

3G-HD/SD SDI Pattern Generator. User Manual

Transcription:

3GHD-EO-D15xx 3GHD Electrical to Optical converter for dense wavelength division multiplexing User manual Rev. 0 [Type text] Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com

Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion USA 1600 Emerson Avenue Oxnard, CA 93033, USA Toll free North America: (866) 515-0811 Outside North America: +1 (805) 247-8560 E-mail: support@nevion.com See http://www.nevion.com/support/ for service hours for customer support globally. Revision history Current revision of this document is the uppermost in the table below. Rev. Repl. Date Sign Change description 0-2009-07-16 AJM First version and release nevion.com 2

Contents Revision history... 2 1 Product overview... 4 2 Specifications... 5 2.1 General... 5 2.2 General functions... 5 2.3 Optical Output... 5 2.4 Electrical Input... 6 2.5 Electrical Output... 6 2.6 Standards... 6 3 Configuration... 7 3.1 Format configuration... 7 4 Connector module... 8 4.1 Mounting the connector module... 8 4.2 Terminal format support... 8 5 Module status... 10 5.1 GPI Alarm Module status outputs... 10 5.2 Front panel Status monitoring... 11 6 Flashlink control... 12 7 DWDM wavelength... 13 General environmental requirements for Nevion equipment... 14 Product Warranty... 15 Appendix A Materials declaration and recycling information... 16 A.1 Materials declaration... 16 A.2 Recycling information... 17 EC Declaration of Conformity... 18 nevion.com 3

1 Product overview The Flashlink 3GHD-EO-D15xx.xx is a single multi bit-rate electrical to optical converter module providing high performance media conversion for various signal formats from 19.4Mbps up to 2970Mbps. Unmatched signal accuracy, even in critical applications with pathological signal patterns makes the 3GHD-EO-D15xx.xx first choice for all optical transport demands. The 3GHD-EO-D15xx.xx can transport all HD and SD signal formats in addition to DVB-ASI and SMPTE310M. It performs electrical equalizing and signal re-clocking, which is selectable on application. High quality optical transmitters using narrowband temperature stabilized 0dBm/+5dBm DWDM DFB lasers. 3GHD-EO-D15xx.xx is suitable for medium and long haul applications. The open system platform of Nevion Flashlink system allows easy interoperability with third party fiber optical systems. The 3GHD-EO-D15xx.xx unit has also two electrical outputs, which reduces the need for additional DA s. The electrical input is equipped with a multi rate cable equalizer providing an equalization of typically 75m of high quality coax cable at 2970Mbps. Figure 1: 3GHD-EO-D Electrical to optical converter nevion.com 4

2 Specifications 2.1 General Power Control +5V DC / 3W, +15V DC/1.5W Control system for access to setup and module status with BITE (Built-In Test Equip.) With standard ITU-T G.652 single mode fiber, we recommend to use the +5dBm DWDM laser for distances longer than 60km for 3G-SDI. 2.2 General functions Card labeling Firmware upgrades Card location in frame through blinking LED The following parameters can be set and monitored via the web and SNMP interface: Function Laser Electrical input Reclocker 1 Reclocker 2 Options On or off Normal or bypass Enable or bypass Enable or bypass The following parameters can be alarmed via the web and SNMP interface: Voltage Reclocker +5V, +3.3V, +5V, +15V and +58V. Loss of lock 2.3 Optical Output Transmission circuit fiber Light source Optical power Optical centre wavelength Max number of channels per fiber Channel spacing Max. wavelength drift Single mode 9/125um DWDM DFB Laser 0dBm (optionally +5dBm) According to ITU-T G.694.1 for DWDM 40 within the C-band for DWDM. 100GHz ± 0.16nm DWDM Temperature range 0 to +40 C Jitter (UI=Unit Interval) 0.135 UI max. @ 270Mbps, nevion.com 5

0.2 UI max. @ 1485Mbps 0.2UI typ. @ 2970Mbps Connector return loss >40dB w/sm fiber Maximum reflected power 4% Connector 2.4 Electrical Input Data rate NRC Data rate re-clocked Equalization SC/UPC 19.4 to 2970 Mbps 270, 1483.5, 1485, 2967 and 2970 Mbps Automatic, Cable equalizer and reclocker can be bypassed to support bitrates down to 2Mbps Impedance Return loss 75 ohm >15dB @ 0-1500MHz >10dB @ 1500-3000MHz Signal level Connector Nom. 800mV BNC 2.5 Electrical Output Number of outputs 2 Connector Impedance Return loss BNC 75 ohm >15dB @ 0-1500MHz >10dB @ 1500-3000MHz Jitter max Max. 0.2UI Peak to peak signal level 0.8V ± 0.1V Signal polarity - 1 non-inverting, 2.6 Standards - 1 inverting Supported standards for electrical and optical ports SMPTE SMPTE 292M, SMPTE 259M-C, SMPTE 297M, SMPTE 305.2M, SMPTE 310M, SMPTE424M DVB-ASI EN50083-9 nevion.com 6

3 Configuration 3.1 Format configuration The 3GHD-EO-D15xx can support a number of different formats. The correct configuration can either be set with a DIP switch or with the GYDA System Controller. The layout of 3GHD-EO-D15xx is shown in the drawing below with the DIP switch to the upper left position. Figure 2: 3GHD-EO-D15xx.xx board layout DIP switch configuration must be set according to the table below: Switch # Label Function, DIP = ON Function, DIP = OFF Comment 1 RCL1 Reclocker ON Reclocker Bypass Reclocker mode 2 EQ Cable equalizer ON Cable equalizer Bypass Equalizer mode 3 RCL2 Not used 4 R1 5 R2 6 E/O 7 D/B 8 E/O 9 DOP 10 OVR Override GYDA control Config. with DIP switch GYDA control Config. with GYDA Select configuration from GYDA All DIP switches are off when pointing towards the release handle. nevion.com 7

4 Connector module The 3GHD-EO-D15xx has a dedicated connector module: MR-TR-C2. This module is mounted at the rear of the sub-rack. The module is shown in the figure below. Unused electrical ports should be terminated with 75ohm. Figure 8: Connector module for 3GHD-EO-D15xx.xx 4.1 Mounting the connector module The details of how the connector module is mounted, is found in the user manual for the sub-rack frame FR-2RU-10-2. This manual is also available from our web site: http://www.nevion.com/ 4.2 Terminal format support The different input and output ports on 3GHD-EO-D15xx.xx can support a number of formats. The table below shows which signal formats are supported on the selected terminals. Terminal format support: Terminal Function Supported Format Mode INPUT Electrical input 3GHD-SDI, HD-SDI, SDI, DVB-ASI, Input SMPTE310, Transparent 1 OPT TX OUTPUT 1 Optical output (Transmitter) 3GHD-SDI, HD-SDI, SDI, DVB-ASI, SMPTE310, Transparent 1 Input Electrical Output 3GHD-SDI, HD-SDI, SDI, DVB-ASI, Output 1 3GHD-EO-D15xx.xx has a Transparent mode. In this mode all reclockers and CDRs are switched off and no jitter attenuation will be performed. This mode may be used for non-standard or unsupported bit rates over shorter distances and up to 1 Gbps. nevion.com 8

Non inverted SMPTE310, Transparent 1 OUTPUT 2 Electrical Output Inverted OPT RX Not used GPI ALARM Open Collector Alarms 3GHD-SDI, HD-SDI, SDI, Transparent 1 Wired alarms Disable laser Output OC Output Input nevion.com 9

5 Module status The status of the module can be monitored in three ways. 1. GYDA System Controller (optional). 2. GPI at the rear of the sub-rack. 3. LEDs at the front of the sub-rack. Of these three, the GPI and the LEDs are mounted on the module itself, whereas the GYDA System Controller is a separate module giving detailed information on the card status. The functions of the GPI and the LEDs are described in sections 5.1 and 5.2. The GYDA controller is described in a separate user manual. 5.1 GPI Alarm Module status outputs These outputs can be used for wiring up alarms for third party control systems. The GPI outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI input laser disable will turn off the laser if this input is shortening to ground/chassis. The GPI connector is shown in figure below. 3GHD-EO-D15xx.xx module GPI pinning: Signal Name Pin # Mode Status General error status for the module Pin 1 Open Collector Laser Fail Laser Fail Alarm Pin 2 Open Collector Not used Pin 3 Open Collector LOS el Los of electrical input signal Pin 4 Open Collector Laser disable Turn off laser Pin 5 Input Ground 0 volt pin Pin 8 0V. Figure 9: GPI output. Electrical Maximums for GPI outputs Max current: 100mA Max voltage: 30V nevion.com 10

5.2 Front panel Status monitoring The status of the module can be easily monitored visually by the LED s at the front of the module. The LEDs are visible through the front panel as shown in the figure below. Figure 10: Front panel indicators for the 3GHD-EO-D15xx.xx. The 3GHD-EO-D15xx.xx has 4 LED s each showing a status corresponding to the GPI pinning. Diode \ State Status Module is faulty Yellow blinking, DWDM laser temperature stabilizing. Red LED Yellow LED Green LED No light LOS/LOCK1 Loss of signal on electrical output reclocker LOS/LOCK2 Not used Loss of lock on reclocker Module is OK Module power is OK Signal OK Module has no power Laser fail Laser is malfunctioning. Laser is off Laser is OK nevion.com 11

6 Flashlink control This card uses the FLP 4.0 protocol. See separate documents for definition of this protocol. nevion.com 12

7 DWDM wavelength ITU694.1 DWDM wavelength. No. [THz] [nm] 59 195,9 1530,33 58 195,8 1531,12 57 195,7 1531,90 56 195,6 1532,68 55 195,5 1533,47 54 195,4 1534,25 53 195,3 1535,04 52 195,2 1535,82 51 195,1 1536,61 50 195,0 1537,40 49 194,9 1538,19 48 194,8 1538,98 47 194,7 1539,77 46 194,6 1540,56 45 194,5 1541,35 44 194,4 1542,14 43 194,3 1542,94 42 194,2 1543,73 41 194,1 1544,53 40 194,0 1545,32 39 193,9 1546,12 38 193,8 1546,92 37 193,7 1547,72 36 193,6 1548,51 35 193,5 1549,32 34 193,4 1550,12 33 193,3 1550,92 32 193,2 1551,72 31 193,1 1552,52 30 193,0 1553,33 29 192,9 1554,13 28 192,8 1554,94 27 192,7 1555,75 26 192,6 1556,55 25 192,5 1557,36 24 192,4 1558,17 23 192,3 1558,98 22 192,2 1559,79 21 192,1 1560,61 20 192,0 1561,41 nevion.com 13

General environmental requirements for Nevion equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature range: 0 C to 40 C - Operating relative humidity range: <90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 55 C - Relative humidity range: <95% (non-condensing) nevion.com 14

Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site: www.nevion.com nevion.com 15

Appendix A Materials declaration and recycling information A.1 Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) 3GHD-EO-D15xx X O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. A.2 Environmentally-friendly use period The manual must include a statement of the environmentally friendly use period. This is defined as the period of normal use before any hazardous material is released to the environment. The guidance on how the EFUP is to be calculated is not finalised at the time of writing. See http://www.aeanet.org/governmentaffairs/qfleopaazxamxqgjsfbeidsdpntpt.pdf for an unofficial translation of the draft guidance. For our own products, Network Electronics has chosen to use the 50 year figure recommended in this draft regulation. Nevion suggests the following statement on An Environmentally Friendly Use Period (EFUP) setting out normal use: EFUP is the time the product can be used in normal service life without leaking the hazardous materials. We expect the normal use environment to be in an equipment room at controlled temperature range (0ºC - 40ºC) with moderate humidity (< 90%, non-condensing) and clean air, not subject to vibration or shock. Further, a statement on any hazardous material content, for instance, for a product that uses some tin/lead solders: Where a product contains potentially hazardous materials, this is indicated on the product by the appropriate symbol containing the EFUP. The hazardous material content is limited to lead (Pb) in some solders. This is extremely stable in normal use and the EFUP is taken as 50 years, by comparison with the EFUP given for Digital Exchange/Switching Platform in equipment in Appendix A of General Rule of Environment-Friendly Use Period of Electronic Information Products. This is indicated by the product marking: 50 It is assumed that while the product is in normal use, any batteries associated with real-time clocks or battery-backed RAM will be replaced at the regular intervals. nevion.com 16

The EFUP relates only to the environmental impact of the product in normal use, it does not imply that the product will continue to be supported for 50 years. A.3 Recycling information Nevion provides assistance to customers and recyclers through our web site http://www.nevion.com/. Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labelled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. nevion.com 17

EC Declaration of Conformity MANUFACTURER AUTHORIZED REPRESENTATIVE (Established within the EEA) MODEL NUMBER(S) DESCRIPTION DIRECTIVES this equipment complies with HARMONISED STANDARDS applied in order to verify compliance with Directive(s) Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway Not applicable 3GHD-EO-D15xx 3GHD Electrical to Optical converter LVD 73/23/EEC EMC 2004/108/EEC EN 55103-1:1996 EN 55103-2:1996 TEST REPORTS ISSUED BY Notified/Competent Body Report no: Nemko E08503.00 TECHNICAL CONSTRUCTION FILE NO YEAR WHICH THE CE-MARK WAS AFFIXED 2008 TEST AUTHORIZED SIGNATORY MANUFACTURER Not applicable AUTHORIZED REPRESENTATIVE (Established within EEA) Not applicable Date of Issue 2009-07-16 Place of Issue Sandefjord, Norway Name Position Thomas Øhrbom QA Director, Nevion Europe (authorized signature) [Type text] Nevion Europe P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com