CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Similar documents
Circuit-Breakers for Motor Protection Series 8523/8

Figure 1: Device components

User's Guide. Digital Stroboscope Tachometer. Model and Model

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Operating instructions Electronic preset counter Type series 717

multi-function meters

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

User Manual. Digital Stroboscope Tachometer. Model and Model

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

CAMTO LTD. Arc detecting system DC/AC

KRF EMC Filters Installation, Operation and Maintenance Manual

GP-500 SERIES - Low Voltage

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Flat-Bed Module Recorders

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Series CT7N Bimetallic Overload Relays

TeSys circuit-breakers

INSTALLATION MANUAL TG - ROTISSERIE OVEN MODELS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Integre4. Audiophile integrated amplifier. v1.2

LIGHT COPILOT II. elationlighting.com Internet:

SQM40/41 Actuators for air and gas dampers

Certificate of Calibration

.Power Distribution Center. PD-1. Instruction Manual

TECHNICAL MANUAL. Operating and Maintenance Instructions for

7 Day Digital Time Switch

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

User Manual Digital Stroboscope

SyG 02 and SyG 02-SB

EA350. Generator Automatic Voltage Regulator Operation Manual

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

Automatic Transfer Switch Control PLC Operator s Manual

PRINCIPLES AND APPLICATIONS

Model Number Structure

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Operating Manual RISH OPTIMA VAF

BSM Evolution USB - Compact ON AIR console. BSM Evolution USB. AEV On Air compact broadcast console

Junior Max (JR Max ) Controller

Power Circuit of a UL508A Panel. Typical UL489 Application

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

USER MANUAL Full HD Widescreen LED Monitor L215IPS

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Wall-/Pipe-Mount Level Indicator

2 Hour Electronic Boost Timer

DLP200M 2 Relay Module for Heating and Cooling Plants

Digital Time Switch. Installation & Operating Instructions

LED Driver Linear / area fixed output

DATAGAUSS XL HARD DRIVE DEGAUSSER

Operating Instructions Dimmer for V Incandescent Lamps

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

DLP600M 6+1 Relay Module for Heating and Cooling Plants

High performance circuit breakers

USER MANUAL GOLDMUND METIS 7 Integrated Amplifier

HS-509 VIBRATION TRIP MODULE

KHT 1000C HV-Probe Calibrator. Instruction Manual

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

MT03A Electronic converter for flow rate transmitters

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

USERS MANUAL GR ONE 300 GR ONE 700 GR ONE 1400

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

User Guide. Centrex Recording Interface

Electronic converter for level transmitters MT03L Instructions manual

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

/ PAT01 USER MANUAL

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

AS09..S 3-pole Contactors - Spring Terminals

Digital Economy Seven Programmer

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Power factor solutions for electric switchboards

Cronotermostato Digitale

INSTALLATION AND OPERATION M

16 Amp Electronic 24 Hour/7 Day Time Controller

TRF STEP-DOWN TRANSFORMER USER MANUAL

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Process Transmitter RMA 422

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

MANUAL ENGLISH Core Club Ordercode: D2314

INSTALLATION & USER GUIDE

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

G1-M1 (Protection Relay)

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

LED Driver Compact fixed output

MS2540 Current Loop Receiver with RS485 Communication

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

MATE3 Owner s Manual Addendum

USER MANUAL Full HD Widescreen LED Monitor L236VA

Transcription:

CURRENT INJECTION RELAY TESTER CR-100 ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M 981 329 / 05A ) (c) CIRCUTOR S.A.

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 2 CURRENT INJECTION RELAY TESTER CR-100 1.- CR-100 DESCRIPTION CR-100 is a current source specially designed for testing the current/time curves of automatic switches and indirect protection relays. The CR-100 consists of an adjustable current source, a control circuit and a measurement unit. - The current source is supplied by the mains, at 230V ac and is provided with an adjustable autotransformer, a separation transformer with three independent outputs and corresponding output terminals. This circuit is protected by 6A automatic breaker. - The control circuit consists of an ON/OFF element, indications and voltage free external terminals to be connected to the contact (NC or NO) of the relay to be tested. - The measurement unit is synchronised with the start and stop of the current circuit. It consists of a digital ammeter and chronometer. The measurement unit and the control circuit are protected by a fuse.

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 3 2.- MAIN CHARACTERISTICS SUPPLY: - Voltage 230Vac + 10% - 15 %, single phase - 50...60 Hz - 6 A maximum ADJUSTABLE CURRENT SOURCE - Current adjustment by turning control knob - Outputs: 0-60 V 10 A max - 600 VA 0-12 V 50 A max - 600 VA 0-6 V 100 A max - 600 VA - Isolated circuit - Maximum overcurrent : 2,5 In - 10 s ( 6 V output ) 1,5 In - 1 min (6 V and 12 V output) CURRENT MEASUREMENT - Digital ammeter with following scales: 19,99A 199,9A 999A - Preselection of the scales by scale selector - Out of scale indication - Protection against over current - Accuracy : ± (0.5 % of readout + 0,5% Full scale) TEST TIME MEASUREMENT Digital chronometer up to 9999,99 seconds TEST CONTROL - Start : By means of ON button - Stop : Automatic by external NC contact Automatic by external NO contact Manual by OFF button - The time of the test is shown in the chronometer display until the "Reset" button is pressed. DIMENSIONS, WEIGHT - Dimensions : 430 x 312 x 265 mm - Approximate weight : 22 kg. ACCESSORIES (included) 2 cables of 6 m for test up to 30 A 1 cable for control of the chronometer 1 instruction manual

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 4 3.- INSTALLATION AND START-UP 3.1.- INITIAL CONSIDERATIONS The manual you hold in your hands contains information and warnings that the user should respect in order to guarantee a proper operation of all the instrument functions and keep its safety conditions. Whether the instrument is not used as manufacturer s specifications, the protection of the instrument can be damaged. When any protection failure is suspected to exist (for example, it presents external visible damages), the instrument must be immediately powered off. In this case contact a qualified service representative. 3.2.- CONNECTION TO THE SUPPLY The power supply must be 230 V, and the maximum current 6 A. The nominal frequency is 50 Hz ( or 60 Hz depending of the model ) ). It is important to use the ground connection. The automatic breaker located in the front part serves as general switch. It is recommended not to connect it until all other connections have been established. 3.3.- CHOOSING CURRENT METER SCALE The current meter scale can be chosen independently of the output to be used. Only the maximum current to be measured has to be taken into account. 3.4.- CHOOSING THE CURRENT OUTPUT The terminals are chosen according to the required current (up to 10A, up to 50 A or up to 100A), the common is the same for both current ranges. The test have always started with the relay under test connected to the "COMMON" and "100 A" ( 6 V ) contacts. In this way, the highest accuracy will be achieved. If with the regulator knob in 100 % position, the necessary current can't be obtained, this connection has to be changed to "COMMON" and "50 A" (12 V ); A higher output voltage ( up to 12 V ) can be obtained this way ; the output current may not be higher than 50 A. If the necessary current can't be obtained, this connection has to be changed to "COMMON" and "10 A" ( 60 V ) ; the maximum current is 10 A.

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 5 3.5.- CHOOSING THE CONNECTION CABLES Once the necessary test current is determined, the CR-100 can be connected to the relay to be tested. - For current of 30 A or lower, the 6 mm 2 section cable have to be used. - If the necessary current is higher than 30A, adequate section cables have to be used (aren' t delivered) 3.6.- CONNECTION OF THE EXTERNAL AUXILIARY CONTACT If it is assumed that the Stop at the end of the test is done automatically, it is necessary also to connect two cables at the EXTERNAL CONTACT-NC/NO terminals and at the contacts of the relay under test. Also the switch has to be set according to the function of the contacts of the relay under test : NC: normally closed (stops when opening) NO: normally open (stops when closing) - In case the stop has to be done manually, the OFF button has to be used. In this case no cable need to be connected to the EXTERNAL CONTACT-NC/NO terminals and the switch has to be set to the ADJUST position.

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 6 4.- TEST ADJUSTMENT 4.1.- PREVIOUS ADJUSTMENT - The ammeter has to be set to the adequate scale - The switch is set to the ADJUST position. - With the turning knob in the 0% position, the ON button is pressed and the required current can be adjusted. THE ADJUSTMENT TIME HAS TO BE AS SHORT AS POSSIBLE TO AVOID PREVIOUS WARMING OF THE RELAY. IN ANY CASE, A CERTAIN COOLING DOWN TIME HAS TO BE PASSED BEFORE EXECUTING THE TEST. 4.2.- CALCULATED ADJUSTMENT When checking the magnetically switching of a relay, the time can be so short that it isn' t possible to adjust the current adequately. In such a case it is necessary to use calculated adjustment although this is not as accurate as real adjustment. This method is based on adjusting the regulator at a current 3, 4 or 5 times lower than to be used during the test. Once this adjustment has been realised, the % value has to be read in the display. Next this % value has to be multiplied by 3, 4 or 5 according to the previously chosen value. Put the regulator in the new position and continue executing the test. Example : Supposing the test of the magnetically switch ( 8 In ; 120 A ) of the relay with the nominal 15 A When adjusting it, the relay switches at not determined point of the regulator, without time to read the reached current. Realisation : - Select the adequate output : ' common ' and '50 A '. - Put the selector in the 'ADJUST' position. - Adjust the current 4 times lower than the test current ( 3 A ) - The value in % that is indicated by the regulator (15 % ) has to be multiplied by 4 (indicating 15 %, this will be 60 % ) - Adjust the regulator at the previously obtained value ( 60 % ) - Continue the test in the same way as if the real adjustment had been used ( put the selector in NC or NO position, press ' ON ', etc ).

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 7 5.- TEST EXECUTION - The " NC/ ADJUST/ NO" switch is set to the required position (NC or NO). - The correct setting of the ammeter has to be set in order to get the maximum accuracy in the read-out. - The RESET button has to be pressed to set the chronometer to 0 - Now the ON button can be pressed that starts the flow of the selected current and the chronometer will start to count. If the CR-100 is not starting to test, probably the "NC/ ADJUST/ NO" switch is in the wrong position. DURING THE TEST, AS THE TEMPERATURE OF THE RELAY UNDER TEST WILL CHANGE, ALSO THE FLOWING CURRENT WILL CHANGE. IT IS THEREFORE NECESSARY TO READJUST THE CURRENT FREQUENTLY TO MAINTAIN THE CURRENT AT THE REQUIRED VALUE. If the stop is automatically, the test is stopped when the relay contact trips. In case the stop has to be manual, the OFF button has to be pressed immediately when the relay trips. In both cases, the duration of the test will be indicated in the chronometer display until the RESET button is pressed. 6.- INTERPRETATION OF THE RESULTS The goal of the test is to know tripping time of a relay for a previous set over-current. The CR-100 relay tripping tester from CIRCUTOR allows the read-out of this time by means of a digital chronometer. The result is given in seconds, decimals and hundreds of seconds. It is the responsibility of the operator that the current stays stable on the set value during the whole test.

---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 8 7.- SAFETY CONSIDERATIONS All installation specification described at the previous chapters named INSTALLATION AND START-UP, INSTALLATION MODES and SPECIFICATIONS. Note that with the instrument powered on, the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts. This instrument is factory-shipped at proper operation condition. 8.- MAINTENANCE The CR-100 does not require any special maintenance. No adjustment, maintenance or repairing action should be done over the instrument open and powered and, should those actions are essential, high-qualified operators must perform them. Before any adjustment, replacement, maintenance or repairing operation is carried out, the instrument must be disconnected from any power supply source. When any protection failure is suspected to exist, the instrument must be immediately put our of service. The instrument s design allow a quick replacement in case of any failure. 8.- TECHNICAL SERVICE For any inquiry about the instrument performance or whether any failure happens, contact to CIRCUTOR s technical service. CIRCUTOR S.A. - After-sales service VIAL SANT JORDI, S/N 08232 VILADECAVALLS (BARCELONA) Tel - + 34 93 745 29 00 fax - + 34 93 745 29 14 E-mail : central@circutor.es Web: www.circutor.com

Lightindicator power suply Power supply 230 V a.c.. ( With fuse ) External contact ON Indicating light signal START START 999 199,9 19,9 N C N O STOP COMMON 100 A 50 A 10 A OUTPUTS : Common- 100 : maximum 100 A - 6 V Common - 50 : maximum 50 A - 12 V Common - 10 : maximum 10 A - 60 V Ammeter RESET button for chronometer A a.c. RESET Scales for ammeter Chronometer Regulator of current Seg. MAIN ELEMENTS (FRONT PART) ANNEX A ---- CURRENT- TIME TRIP TESTER CR-100 --------------- Page. 9