Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

Similar documents
Dragonfly Quad. User Manual V1.4. Order code: EQLED101

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

ORDER CODE: EQLED65 USER MANUAL

Fusion 120 Zoom. User Manual. Order code: EQLED068

Stratos Duo RGB. User Manual. Order code: EQLED371

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Programmable Micro Remote LED Controller for RGB LED Strips - 12 or 24 VDC Part number: PMRC

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. Wi Fi Mood Lighting. As supplied

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Spectra Batten (Order code: LEDJ95)

Pixel LED SPI Digital Controller

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

DATA SHEET Panorama Rudder Indicator, TRI-2

Software Version V1.0 Manual Revision V1.2

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

Local Control Network Function. The LCN-HL4 can be connected to all intelligent LCNI-port test key

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

1440/2880 HP RGB+WW+CW

INSTALLATION & USER GUIDE

PRODUCT SPECIFICATIONS

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

LED PAR 36 USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Media Tube HO RGBW. High intensity SMT RGB and White LEDs Million additive RGB colors; White CCT 6500K

Touch Panel RGB LED Controller Part No. touch-panel-rgb

BROTHER, BROTHER & SONS

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

DAGON Company Leszno Jackowskiego 24 Street tel DAGON Lighting series SPL-3

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

Show Designer 3. Software Revision 1.15

USER MANUAL. VP-425 PC / Component to HDMI Scaler MODEL: P/N: Rev 3

Flat LED Par Can Light

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

2X2 Panel. 1X2 Panel

Media Tube HO RGBW Million additive RGB colors; White CCT 6500K. Algorithms enable auto control of white LED by 3-channel RGB values.

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Woda W7 Underwater Spotlight

Proportional output thumbwheels - sprung to centre

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-434 Component/UXGA HDMI Scaler. P/N: Rev 6

LED SPOT HEAD USERS GUIDE

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

VARIGATE 4+ MANUAL V.1

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

DALI TOUCHPANEL BASIC TW. Operating and control unit

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

multi-function meters

Media Tube HO RGB. 896mm mm mm kg 1.8lbs. 0.4kg 0.9lbs. 1.24kg 2.7lbs. 1.02kg 2.3lbs

USER MANUAL. VP-424 HDMI to HDMI Scaler MODEL: P/N: Rev 2

Mini LED Pixel Controller Part number: PX-SPI-mini

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

PLL2210MW LED Monitor

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

PL2410W LCD Monitor USER'S GUIDE.

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

USER MANUAL. VP-435 Component / UXGA HDMI Scaler MODEL: P/N: Rev 13

LINK EXT40-4KUHD 4:4:4 HDR HDBaseT Extender. User Manual. Version: V1.0.1

02/11/2015

Linealux L5 Linear Facade

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Owner s Manual LED COMMANDER 16/2

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-480 CV to 3G HD-SDI Scaler. P/N: Rev 3

Electrical connection

4 Wiring Brochure Wiring and installation of specific control

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

CT-DMX-300 LED Controller

Gamma instabus. Technical product information

PRODUCT SPECIFICATIONS

SHOWLINE SL epar 180 LUMINAIRE SPECIFICATIONS.

Truss Light COB LED 30W

LED-BANK4 USER MANUAL. COLORbank 4

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

PRESET 10 ARCHITECTURAL OWNERS MANUAL

2-output DALI controller

CPLUS-V2PE 4K UHD+ HDMI to Dual HDMI Scaler with Audio De-Embedding & Test Patterns

Luminaire installation box Surface-mounted box Ceiling installation box

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Mini LED Pin Spot Light Model: PLS00571

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

FD Trinitron Colour Television

TRF STEP-DOWN TRANSFORMER USER MANUAL

American DJ. Show Designer. Software Revision 2.08

Transcription:

Artistic Licence moody & moody cv User Guide Download the user guide by scanning the following QR code: moody & moody cv User Guide Version 2-0

Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed by a suitably qualified technician and in accordance with electrical regulations in the country of use. Unless directed in the instructions there are no user serviceable parts inside the outer case of this product. Always disconnect from the power supply when not in use. Any specific IP rating, where appropriate, is given in the instructions. Unless otherwise stated this product is designed for indoor use only. If used outdoors it MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be exposed to rain or moisture. Do not allow liquid to penetrate the product. Contains small parts. Please keep out of reach of young children. Please recycle all packaging. Copyright Artistic Licence Engineering Ltd. All rights reserved. moody & moody cv User Guide Page 2

Connections moody 3 4 1 5 2 moody cv 3 4 1 5 2 ArtisticLicence.com DATA+ DATA- COM DALI DALI DMX512 DALI PROG GND 12-24V Artistic Licence ArtisticLicence.com +V DC +V DC RED GRN BLUE LED CVOUTPUTS PROG GND 12-24V Artistic Licence 8 7 6 8 7 6 moody moody cv Ref. Connection Type Description Connection Type Description 1 Blue- O/P DALI O/P DALI connection 2 Green- O/P 3 DMX COM (Pin 1) LED O/P Red- O/P 4 DMX O/P DMX- (Pin 2) Common+ 5 DMX+ (Pin 3) Common+ 6 9-24 VDC 12-24 VDC Power Input Power Input 7 GND GND 8 Switch* Programme enable Switch* Programme enable * Remove the programming header (small plastic device) to disable programming Mounting Diagram 86 60.6 86 4.2 10 15.2 moody & moody cv User Guide Page 3

Overview moody encompasses a range of wall panel controllers with a simple rotary dial form factor, providing control over white lights or colour changers. Outputs are DMX512, DALI or constant voltage (CV) dimming. The standard product is supplied in a UK single-gang wall panel with a dry-line back box. moody requires a (separately purchased) fascia plate which is simply clicked onto the front of the product. The Scolmore definity click cover plates are compatible. Programming mode is entered and exited by holding down the rotary dial for 3 seconds. The desired parameters are programmed using simple sequences that involve turning the dial to the desired colour or intensity (as shown by the LED colour mimic at the centre of the dial), then pressing it to move on to the next setting. Settings are retained in a non-volatile memory, so power loss will not erase programming. y moody i1, i6 & i16 Intensity (denoted by i) controllers for white light with programmable scenes. The number defines the number of channels controlled. O/Ps are DMX or DALI. y moody x1, x3 & x10 and moody z1, z3 & z10 RGB (denoted by x/z) zone controller with programmable scenes (both hue and saturation levels can be set). The number defines the number of zones controlled. The wheel rotation is used to adjust the overall intensity (x series) or colour of zone 1 (z series). O/Ps are DMX or DALI. y moody y1, y3 & y10 RGBW (denoted by y) zone controller with programmable scenes. The number defines the number of zones controlled. O/Ps are DMX or DALI. y moody f1, f3 & f10 Dynamic RGB colour effects (denoted by f) zone controller with programmable colours and fade rate. The number defines the number of zones controlled. O/Ps are DMX or DALI. y moody cvi1, cvx1, cvz1 & cvf1 As i1, x1, z1 & f1 but with built-in 12-24 VDC constant voltage dimming output instead of DMX & DALI. moody variant DMX output DALI output CV dimming output Autofade Wheel LED mimic Overall Control No. of Fixtures No. of DMX channels i1 Y Y* N N Intensity Intensity 1 1 i6 Y Y N N Intensity Intensity 6 6 i16 Y Y N N Intensity Intensity 16 16 x1 Y Y N N Intensity RGB 1 3 x3 Y Y N N Intensity RGB 3 9 x10 Y Y** N N Intensity RGB 10 30 y1 Y Y N N Intensity RGBW 1 4 y3 Y Y N N Intensity RGBW 3 12 y10 Y Y** N N Intensity RGBW 10 40 z1 Y Y N N Colour RGB 1 3 z3 Y Y N N Colour RGB 3 9 z10 Y Y** N N Colour RGB 10 30 f1 Y Y N Y Intensity RGB 1 3 f3 Y Y N Y Intensity RGB 3 9 f10 Y Y** N Y Intensity RGB 10 30 cvx1 N N Y N Intensity RGB 1 n/a cvz1 N N Y N Colour RGB 1 n/a cvf1 N N Y Y Intensity RGB 1 n/a cvi1 N N Y N Intensity Intensity 1 n/a * Uses DALI broadcast moody & moody cv User Guide ** Uses DALI channel addressing rather than groups Page 4

The moody i series y moody i1 -Controls - a single intensity channel of DMX or DALI --DMX uses 1 channel for intensity --DALI uses broadcast for intensity y moody i6 --Controls 6 intensity channels of DMX or DALI --DMX uses 6 channels for intensity --DALI uses 6 groups for intensity y moody i16 --Controls 16 intensity channels of DMX or DALI --DMX uses 16 channels for intensity --DALI uses all 16 groups for intensity Operation (moody i series) From factory, all scene channels are programmed to full. At power on, moody i will automatically fade the master level to full over 5 seconds. If the lights are on, briefly press the control: moody fades the master level to zero over 5 seconds. If lights are off, briefly press the control: moody fades the master level to the previously used setting over 5 seconds. Rotate control clockwise to increase master level. Rotate control counter-clockwise to reduce master level. The LED indictor shows the master level. To programme a scene, please see instructions below on how to set the intensity of each channel. Programming (moody i series) Step 1 To enter programming mode, press and hold control for 3 seconds. Step 2 moody s indicator LED flashes white to acknowledge it has entered intensity programming mode, then shows the intensity of the first channel. moody & moody cv User Guide Page 5

- + Step 3 - set the intensity Rotate clockwise to increase intensity. Rotate counter-clockwise to decrease intensity. Step 4 Press once to move onto the next channel. moody s indicator LED flashes white to acknowledge. Repeat steps 3 & 4 until all channels have been programmed. Step 5 - exit programming mode Press and hold control for 3 seconds to exit programming mode. Step 6 (end) moody displays the master level and is now in normal operating mode. The moody x & z series The moody y series y moody x1, z1 -C - o nt r o l s a s i n g l e RG B zo n e o f D M X or DALI --Wheel controls master level (x series) or zone 1 colour (z series) --DMX uses 3 channels for colour --DALI uses 3 groups for RGB y moody x3, z3 --Controls 3 RGB zones of DMX or DALI --Wheel controls master level (x series) or zone 1 colour (z series) --DMX uses 9 channels for colour --DALI uses 9 groups (RGB X 3) y moody x10, z10 --Controls 10 RGB zones of DMX or DALI --Wheel controls master level (x series) or zone 1 colour (z series) --DMX uses 30 channels for colour --DALI uses 30 consecutive short addresses (RGB X 10) moody & moody cv User Guide y moody y1 -C - o nt r o l s a s i n g l e RG BW z o n e o f DMX or DALI --Wheel controls master level --DMX uses 4 channels for colour --DALI uses 4 groups for RGBW y moody y3 --Controls 3 RGBW zones of DMX or DALI --Wheel controls overall intensity --DMX uses 12 channels for colour --DALI uses 12 groups (RGBW X 3) y moody y10 --Controls 10 RGBW zones of DMX or DALI --Wheel controls overall intensity --DMX uses 40 channels for colour --DALI uses 40 consecutive short addresses (RGBW X 10) Page 6

Operation (moody x & y series) From factory, all scene channels are programmed to cyan. At power on, moody will automatically fade the master level to full over 5 seconds. If lights are on, briefly press the control: moody fades the master level to zero over 5 seconds. If lights are off, briefly press the control: moody fades the master level to the previously used setting over 5 seconds. Rotate control clockwise to increase master level. Rotate control counter-clockwise to reduce master level. The LED indictor shows the master level and colour of zone 1. To programme a scene: please see instructions below on how to set the intensity and colour of each zone. Operation (moody z series) From factory, all scene channels are programmed to cyan. At power on, moody will automatically fade the master level to full over 5 seconds. If lights are on, briefly press the control: moody fades the master level to zero over 5 seconds. If lights are off, briefly press the control: moody fades the master level to full over 5 seconds. Rotate control clockwise or counter-clockwise to change the colour of Zone 1. The LED indictor shows the master level (always 100%) and colour of zone 1. To programme a scene: please see instructions below on how to set the intensity and colour of each zone. Note on the differences between the moody x, y and z series A detailed comparison between the variants may be found in the table on page 4. However, in summary, the moody x & z series control RGB fixtures, whereas moody y controls RGBW fixtures. The operation of the z series is the same as the x series, with one important difference: the wheel rotation is used to adjust the colour of zone 1 in the z series, as opposed to master level in the x series. The colour is not stored and will revert to the programmed colour when power is cycled. This makes the z series useful in preserving the intended colour scheme in e.g. a hotel room, while giving guests temporary colour control over one area. Programming (moody x, y & z series) Step 1 To enter programming mode, press and hold control for 3 seconds. Step 2 - programme the colour (hue) moody s indicator LED flashes red to acknowledge it has entered colour programming mode, then shows the colour of the zone. moody & moody cv User Guide Page 7

Step 2 (continued) a) Wait 5 seconds; moody will start slowly cycling through the colour palette. When you see the colour you want, briefly press the control. b) Alternatively, rotate the control clockwise or counter-clockwise to move forwards or backwards through the colour palette. When you see the colour you want, briefly press the control. N.B. During the programming process, the relevant lights will change to show the effect of your zone programming. Step 3 - programme the white level / saturation moody s indicator LED flashes white to acknowledge it has entered white level programming mode, then displays the white level of the zone. a) Wait 5 seconds; moody will start slowly cycling through the white levels. When you see the white level you want, briefly press the control. b) Alternatively, rotate the control clockwise or counter-clockwise to increase or decrease the white level. When you see the white level you want, briefly press the control. N.B. In moody x or z, the white level is really saturation - it controls the amount of white that is mixed in with the colour and allows shades to be created. In moody y, the white level is the W output of the RGBW fixture. Step 4 - programme the other zones Programming of zone 1 is now complete. moody s indicator LED flashes red to acknowledge that it is ready to accept colour programming for zone 2. Repeat steps 2 & 3 for each zone. Step 5 - exit programming mode When programming of all zones is complete, press and hold the control for 3 seconds to exit programming mode. moody acknowledges by flashing green. Step 6 (end) moody displays the master level (always 100% for the z series) and colour of zone 1. It is now in normal operating mode. moody & moody cv User Guide Page 8

The moody f series y moody f1 --Dynamic effects control over a single RGB zone of DMX or DALI --Programmable colours and fade rate: choose the start and end colour, and specify the fade rate between them --DMX uses 3 channels for colour --DALI uses 3 groups for RGB y moody f3 --Dynamic effects control over three RGB zones of DMX or DALI --Programmable colours and fade rate: choose the start and end colour (can be different for each zone), and specify the fade rate between them (same for all zones) --DMX uses 9 channels for colour --DALI uses 9 groups (RGB X 3) y moody f10 --Dynamic effects control over ten RGB zones of DMX or DALI --Programmable colours and fade rate: choose the start and end colour (can be different for each zone), and specify the fade rate between them (same for all zones) --DMX uses 30 channels for colour --DALI uses 30 consecutive short addresses (RGB X 10) Operation (moody f series) From factory, the default fade time is set to 4 minutes between start and end colour. The end colour(s) are all set to magenta. The start colour(s) begin at red and increase 10 degrees per zone, as shown in the Colour Wheel below If lights are on, briefly press the control: moody fades the master level to zero over 5 seconds. If lights are off, briefly press the control: moody fades the master level to the previously used setting over 5 seconds. Rotate control clockwise to increase master level. Rotate control counter-clockwise to reduce master level. The LED indictor shows the master level and real-time colour of zone 1. To programme a dynamic effect, please refer to instructions on the next page. Colour Wheel Operation of the moody f series is based on a fade from one colour to another. The hue is expressed as an angle as shown in the diagram opposite. moody is designed such that, during programming, the fade goes clockwise in the direction of increasing angle. For example, programming a start colour of red and an end colour of yellow will result in a fade that passes through orange. Contrastingly, programming a start colour of yellow and an end colour of red will result in a fade that passes through green, blue and magenta. During operation, once the end colour is reached, the colour sequence is reversed to avoid a sudden discontinuity of colour. moody & moody cv User Guide Page 9

Programming (moody f series) Step 1 To enter programming mode, press and hold control for 3 seconds. Step 2 - programme the fade time moody acknowledges by flashing a colour that indicates the currently programmed fade rate (as shown in chart opposite). Rotate control clockwise or counterclockwise to increase or decrease the fade rate (colour will change accordingy). When you attain the desired the fade rate, briefly press the control. Colour Start-to-end time (min) Red 0.5-15 Orange 15-30 Yellow 30-45 Green 45-60 Cyan 60-75 Blue 75-90 Pink 90-105 Magenta 105-120 Step 3 - programme the start colour (hue) moody s indicator LED flashes red to acknowledge it has entered start colour programming mode, then shows the start colour of the zone. (Please read Colour Wheel note on page 8 before programming colour). a) Wait 5 seconds; moody will start slowly cycling through the colour palette. When you see the colour you want, briefly press the control. b) Alternatively, rotate the control clockwise or counter-clockwise to move forwards or backwards through the colour palette. When you see the colour you want, briefly press the control. N.B. When programming a zone, the relevant light will change to show the effect of your programming (the other lights will not be illuminated to make it easier to see the zone you are programming). Step 4 - programme the start white level (saturation) moody s indicator LED flashes white to acknowledge it has entered white level programming mode, then shows the start white level of the zone. a) Wait 5 seconds; moody will start slowly cycling through the white levels. When you see the white level you want, briefly press the control. b) Alternatively, rotate the control clockwise or counter-clockwise to increase or decrease the white level. When you see the white level you want, briefly press the control. N.B. In moody f, the white level is really saturation - it controls the amount of white that is mixed in with the colour and allows shades to be created. moody & moody cv User Guide Page 10

Step 5 - programme the end colour (hue) moody s indicator LED flashes purple to acknowledge it has entered end colour programming mode, then shows the end colour of the zone. a) Wait 5 seconds; moody will start slowly cycling through the colour palette. When you see the colour you want, briefly press the control. b) Alternatively, rotate the control clockwise or counter-clockwise to move forwards or backwards through the colour palette. When you see the colour you want, briefly press the control. Step 6 - programme the end white level (saturation) moody s indicator LED flashes white to acknowledge it has entered white level programming mode, then shows the end white level of the zone. a) Wait 5 seconds; moody will start slowly cycling through the white levels. When you see the white level you want, briefly press the control. b) Alternatively, rotate the control clockwise or counter-clockwise to increase or decrease the white level. When you see the white level you want, briefly press the control. Step 7 - programme the other zones Programming of zone 1 is now complete. moody is ready to accept programming for zone 2 and indicates this by flashing red. Repeat steps 3-6 for each zone. Step 8 - exit programming mode When programming of all zones is complete, moody will revert to step 2. If you are happy with all the settings, press and hold the control for 3 seconds to exit programming mode. moody acknowledges by flashing green. Step 9 (end) moody displays the master level and real-time colour of zone 1. It is now in normal operating mode. moody & moody cv User Guide Page 11

The moody cv series y moody cvx1 and cvz1 --Controls a single RGB zone with CV dimmer output at 12-24V --Wheel controls intensity (cvx1) or colour (cvz1) y moody cvi1 --Controls a single intensity channel with CV dimmer output at 12-24V --Wheel controls intensity y moody cvf1 --Dynamic effects control over a single RGB zone with CV dimmer output at 12-24V --Programmable colours and fade rate: choose the start and end colour, and specify the fade rate betwen them --Wheel controls intensity Operation (moody cv series) moody cv products have a built in constant voltage dimmer rated at 12-24 VDC and LED drive current 5A. The output is RGB common anode. Operation and programming of moody cvi1, cvx1, cvz1 and cvf1 follow moody i1, x1, z1 and f1 respectively. Note on DMX channel usage moody outputs 42 DMX channels (although only moody y10 uses all of them). The refresh rate is approximately 100 Hz. A number representing the programmed fade time (moody f series) is output on DMX channel 41. This is relevant only for customers needing to specify an exact fade time. Please refer to the Help Desk article moody: Fade time detail on the Artistic Licence website. DMX channel 42 contains the firmware revision. moody & moody cv User Guide Page 12

Application diagrams moody (DMX input) PSU moody i, x, y, z or f DMX dimmer DMX512 CV dimming White light (moody i) or coloured feature lighting (moody x,y,z,f) DC power moody (DALI input) PSU moody i, x, y, z or f DALI dimmer DALI CV dimming White light (moody i) or coloured feature lighting (moody x,y,z,f) DALI Bus PSU e.g. Rail-PSU-D4 DC power moody cv PSU moody cv CV dimming Coloured feature lighting DC power moody & moody cv User Guide Page 13

moody & moody cv Specification Mechanical y Housing: UK 1-gang style panel y Fascia (buy separately): Compatible with Scolmore definity click range y Overall dimensions: 86 mm (H) x 86 mm (W) x 40 mm (D) y Depth behind mounting: 15.2 mm y Mounting: UK 1-gang back-box 35mm (supplied) y Mounting screw centres: 60.6 mm y Mass: 0.11 kg y Country of manufacture: UK Environmental y Operating temperature: 0 C to 40 C y Storage temperature: -10 C to +50 C y Operating relative humidity (max): 80% non-condensing y IP rating: IP20 indoor use only y Certification: CE, WEEE, RoHS y Warranty: 2-year (return to base) Power & Electrical y Input voltage: 9-24 VDC (moody i, x, z, y, f) y Input voltage: 12-24 VDC (moody cv) y Input connector: 2-pin screw terminal DC voltage input (1 no.) --0.2-1.5mm 2 (30-16AWG) solid conductors --0.2-1.0mm 2 (30-16AWG) solid conductors y Input power (max): 500 mw (moody i, x, z, y, f) y Input power (max): 500 mw plus LED load (moody cv series) y Duty cycle: 100% @ 25 C User Interface / Indication y Rotary dial (1 no.) for controlling master level (moody i, x, y, f, cvx1, cvf1, cvi1) with push on/off y Rotary dial (1 no.) for controlling the colour of zone 1 (moody z, cvz1) with push on/off y LED indication: Shows master level and: Programming y Rotary dial (1 no): push and hold for 3 secs to enter / exit programming mode y Rear jumper (1 no): Inhibits programming y Set white light scenes for 1 (moody i, cvi1), 6 (moody i6) or 16 (moody i16) channels y Set the hue and saturation of 1, 3 or 10 independent RGB zones (moody x and z) y Set the hue and white level of 1, 3 or 10 independent RGBW zones (moody y) y Set the start colour, end colour and fade time for 1 (moody f1, cvf1), 3 (moody f3) or 10 (moody f10) RGB zones y Set the hue and saturation of one RGB zone (moody cvx1, cvz1) Control/Isolation (moody i, x, z, y & f) y Output Protocols: DMX512-A, DALI y DMX Output connector: 3-pin Screw Terminal (1 no.) --0.2-1.5mm 2 (30-16AWG) solid conductors --0.2-1.0mm 2 (30-16AWG) solid conductors y DMX Output isolation: Ground referenced y DALI Output connector: 2-pin Screw Terminal (1 no.) --0.2-1.5mm 2 (30-16AWG) solid conductors --0.2-1.0mm 2 (30-16AWG) solid conductors y DALI Output isolation: 2kV opto-isolated Control (moody cv series) y Constant Voltage modulation: Pulse Width Modulation y Constant Voltage Output connector: 5-pin Screw Terminal (1 no.) --0.2-1.5mm 2 (30-16AWG) solid conductors --0.2-1.0mm 2 (30-16AWG) solid conductors y Output Voltage: identical to input voltage (12-24 VDC) y LED drive Current: 5A Ordering Info y Product code: moody y Variant must be specified from the --colour of zone 1 (moody x, z, y, cvx1, following options: i1, i6, i16, x1, x3, x10, cvz1) y1, y3, y10, z1, z3, z10, f1, f3, f10, cvx1, --real-time colour of zone 1 (moody f, cvf1) cvz1, cvf1, cvi1 moody & moody cv User Guide Page 14

Package contents y moody y Back-box Accessories (not included) y PSU moody & moody cv User Guide Page 15

Compliance All Products manufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE and RoHS regulations. Product specific information is available on request. CE Compliance moody and moody cv are CE compliant Waste Electrical & Electronic Equipment (WEEE) Artistic Licence is a member of a WEEE compliance scheme and will happily recycle any of our products that you, at your expense, return to us. Warranty All products are covered from date of purchase by a two-year return to base warranty. By return to base, we mean that the customer is responsible for all costs of transport to and from Artistic Licence. Returns will not be accepted without prior authorisation. In order to discuss a request to return goods, please email: Sales@ArtisticLicence.com Artistic Licence The Mould Making Workshop Soby Mews Bovey Tracey TQ13 9JG United Kingdom Telephone +44 (0) 20 8863 4515 Email: Web: Sales@ArtisticLicence.com www.artisticlicence.com Support@ArtisticLicence.com Due to our policy of continuing product improvement specifications are subject to change without notice