R&S EDS300 DME/Pulse Analyzer Specifications

Similar documents
R&S EDST300 TACAN/DME Station Tester Specifications

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z154 Calibration Unit Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S FPC1000 Spectrum Analyzer Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S HF907DC SHF Downconverter Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S ZND Vector Network Analyzer Specifications

R&S GU221 Filter Control Unit Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

R&S SGU100A SGMA Upconverter Specifications

R&S DDF200M Digital Direction Finder Specifications

R&S ZNBT Vector Network Analyzer Specifications

R&S DST200 RF Diagnostic Chamber Specifications

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S AVG050 DVB Satellite Receiver Specifications

R&S ZN-ZTW Torque Wrench Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S SGS100A SGMA RF Source Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S RT-Zxx Standard Probes Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S FPS-K18 Amplifier Measurements Specifications

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

EUTRA/LTE Downlink Specifications

EX-IQ-Box Digital Signal Interface Module Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S BBL200 Broadband Amplifier Specifications

R&S RSC Step Attenuator Where precise signal levels count

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S FPL1000 Spectrum Analyzer Specifications

R&S ZNL Vector Network Analyzer Specifications

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

DVG MPEG-2 Measurement Generator

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

EUTRA/LTE Measurement Application Specifications

R&S NRP Power Sensor Family Specifications

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

R&S FPC-Z10 Teaching Kit Getting Started

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

R&S EDS300 DME/Pulse Analyzer Precise distance and pulse analysis for ground and air measurements

R&S VSE Vector Signal Explorer Base Software Specifications

R&S M3TR R&S VT3050C 50 W VHF/UHF Compact Power Amplifier Specifications

R&S EDST300 TACAN/DME Station Tester Maintenance checks and signal-in-space analysis on TACAN and DME stations

R&S TS-PIO4 Digital Functional Test Module 32-channel programmable digital I/O module

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Rohde & Schwarz Service that adds value

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S SMF100A Microwave Signal Generator Specifications

R&S TS6300 ILS Test System Mobile automatic test solution for ILS ground measurements

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Be ahead in 5G. Turn visions into reality.

R&S TSMx Radio Network Analyzers Powerful scanner family for mobile applications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

R&S FSMR Measuring Receiver Specifications

ESU EMI Test Receiver Specifications

R&S VSE Vector Signal Explorer Base Software Specifications

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

RF amplifier testing from wafer to design-in

R&S SGMA Product Family Compact fast reliable

R&S EDS300 DME/Pulse Analyzer Precise distance and pulse analysis for ground and air measurements

Transcription:

R&S EDS300 DME/Pulse Analyzer Specifications year Data Sheet Version 04.01

CONTENTS Definitions... 3 Specifications... 4 Frequency... 4 Level... 4 DME signal analysis... 4 TACAN signal analysis (R&S EDS-K1 option, export license required)... 5 Pulse shape analysis (R&S EDS-K2 option)... 5 DME distance measurement... 6 Multi-DME measurement (R&S EDS-K5 option)... 6 Low-power interrogator (R&S EDS-B2 option)... 7 High-power interrogator (R&S EDS-B4 option)... 7 Inputs and outputs (front)... 7 Inputs and outputs (rear)... 7 General data... 8 Ordering information... 9 2 Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are indicated as follows: parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer 3

Specifications Frequency Frequency range Frequency resolution 960 MHz to 1215 MHz 0.1 MHz Reference frequency, internal Accuracy ±(time since last adjustment aging rate + temperature drift + calibration accuracy) Aging per year 1 ppm Temperature drift +5 C to +40 C 1 ppm Achievable internal calibration accuracy 1 ppm Level 1 Max. input level DC voltage RF power +25 V DC +13 dbm Absolute level Display range 120 dbm to +20 dbm Measurement range (average) 2 low noise mode (preamplifier on) 110 dbm to 10 dbm (nom.) normal mode (preamplifier off) 100 dbm to +5 dbm (nom.) low distortion mode (attenuator on) 85 dbm to +13 dbm (nom.) autorange mode 110 dbm to +13 dbm (nom.) Measurement range (peak) 2 low noise mode 100 dbm to 10 dbm (nom.) normal mode 90 dbm to +5 dbm (nom.) low distortion mode 75 dbm to +13 dbm (nom.) autorange mode 100 dbm to +13 dbm (nom.) Level resolution 0.1 db Average level deviation 20 dbm, normal mode, DME mode, 0.5 db +20 C to +30 C Additional average linearity error 0 db to 70 db, normal mode, DME mode, 0.5 db +20 C to +30 C Spurious response without input signal, low noise mode < 95 dbm Total measurement uncertainty Average level deviation Peak level deviation signal: 0 dbm to 70 dbm, 95 % confidence level, +20 C to +30 C signal: 0 dbm to 70 dbm, 95 % confidence level, +20 C to +30 C < 1 db (nom.) < 1 db Intermodulation 1 db compression point normal mode +10 dbm (nom.) Third-order intercept point (TOI) normal mode +20 dbm (typ.) DME signal analysis Standard ICAO Annex 10, ICAO Doc 8071 Input level range pulse recognition efficiency > 70 % 95 dbm to +10 dbm (nom.) DME measurement Peak level deviation 20 dbm, +20 C to +30 C 0.6 db Peak level linearity error 0 db to 70 db, +20 C to +30 C 0.5 db Total peak level deviation standard DME signal in line with ICAO Annex 10, level range 0 dbm to 70 dbm, 95 % confidence level, +20 C to +30 C < 1 db (nom.) 1 Without R&S EDS-B1 option. 2 Overload display in the event of an overload condition caused by in-band or out-of-band signals. 4 Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer

Pulse spacing Resolution 0.001 µs < 0.05 µs Pulse repetition rate < 8000/s (nom.) Additional measurement values identifier frequency, identifier code, pulse repetition rate, RF frequency offset TACAN signal analysis (R&S EDS-K1 option, export license required) Standard STANAG 5034, MIL-STD-291C Input level range 92 dbm to +10 dbm Modulation depth 5 % to 50 % Resolution 0.01 % 15/135 Hz ± 5 % 3 < 0.5 % AF Resolution 0.01 Hz 15/135 Hz ± 5 % 3 < 0.1 Hz Bearing Resolution 0.01 80 dbm to +10 dbm, < 0.2 standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 20 %, measurement time 1 s Additional bearing error 80 dbm to +10 dbm, < 0.1 standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 7 % to 30 %, measurement time 1 s 90 dbm to 80 dbm, < 0.5 standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 20 %, measurement time 1 s Bearing acquisition time < 3 s Phase angle 15 Hz/135 Hz Resolution 0.01 standard TACAN signal in line with < 0.5 (nom.) STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 20 %, measurement time 500 ms Additional measurement values MRB/ARB pulse count, MRB/ARB pulse spacing Pulse shape analysis (R&S EDS-K2 option) Resolution bandwidth Resolution bandwidth selectable 0.5 MHz, 10 MHz (nom.) Display range displayed noise floor up to +20 dbm Time/division 0.5/1/2/5/10/20/50 µs, selectable Reference level 70 dbm to +20 dbm Trace functions clear/write, average, max. hold Trigger Trigger source level/external/dme pulse/interrogator with R&S EDS-K1 option additionally MRB/ARB trigger source Trigger delay 500 µs to +8000 µs DME pulse shape analysis standard ICAO Annex 10, ICAO Doc 8071 Pulse shape analysis rise time, duration, decay time Resolution 0.01 µs < 0.1 µs (nom.) Pulse spacing Resolution 0.001 µs < 0.05 µs Additional measurement values peak variation 3 Max. frequency drift of modulation signal. Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer 5

DME distance measurement 4 Standard ICAO Annex 10, ICAO Doc 8071 Input level range 97 dbm to +10 dbm (nom.) Distance measurement Distance range 0 NM to 400 NM (nom.) Resolution 0.01 µs, 0.001 km, 0.001 NM 80 dbm to +10 dbm, measurement time 100 ms 95 % confidence level 100 ns, 15 m (nom.), 0.01 NM (nom.) 90 dbm to 80 dbm, reply efficiency > 70 %, measurement time 500 ms 95 % confidence level 97 dbm to 90 dbm, measurement time 500 ms 95 % confidence level 500 ns, 75 m (nom.), 0.05 NM (nom.) 500 ns, (nom.) 75 m (nom.), 0.05 NM (nom.) Pulse rate search mode 5/s to 150/s track mode 5/s to 30/s test mode (with R&S EDS-B2 option only) max. 3000/s (output power range -30 to +15 dbm) max. 1500/s (output power range +15 to +43 dbm) Lock-on time reply efficiency > 70 %, < 3 s pulse rate search mode = 150/s Modes search, track, memory Additional measurement values reply efficiency, velocity Multi-DME measurement (R&S EDS-K5 option) 5 Standard ICAO Annex 10, ICAO Doc 8071 Distance measurement search/track mode up to 10 DME channels Input level range 95 dbm to +10 dbm (nom.) Additional level measurement uncertainty < 1 db Distance range Resolution 80 dbm to +10 dbm, measurement time 5 ms/channel 95 % confidence level 90 dbm to 80 dbm, reply efficiency > 70 %, measurement time 100 ms/channel 95 % confidence level 95 dbm to 90 dbm, measurement time 100 ms/channel 95 % confidence level 0 NM to 310 NM (nom.) 0.001 km, 0.001 NM 0.03 NM, 45 m (nom.) 0.05 NM, 75 m (nom.) 0.05 NM (nom.) 75 m (nom.) Pulse rate search/track mode 20/s (nom.)/channel Lock-on time reply efficiency > 70 % < 5 s Modes search, track, memory Additional measurement values for every channel pulse spacing, frequency offset, ID code, reply efficiency 4 Minimum requirement: 20 W low-power interrogator (R&S EDS-B2), optional: 500 W high-power interrogator (R&S EDS-B4). 5 Minimum requirement: R&S EDS-B1, R&S EDS-B2 (optional: R&S EDS-B4). 6 Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer

Low-power interrogator (R&S EDS-B2 option) Standard ICAO Annex 10, ICAO Doc 8071 Maximum output power DME peak power, into 50 Ω load 20 W (+43 dbm) ± 1.5 db Setting range 30 dbm to +43 dbm, in 0.5 db steps Peak variation coded pulse pair on 50 Ω load < 0.5 db Pulse rate up to +15 dbm 3000/s (max.) +15 dbm to +43 dbm 1500/s (max.) Pulse spacing X mode 12 µs (default) Y mode 36 µs (default) Setting range X/Y mode 11 µs to 42 µs in 0.1 µs steps 0.05 µs Pulse duration 50 % points 3.5 µs ± 0.2 µs Pulse rise time 10 % to 90 % 2.5 µs ± 0.25 µs Pulse decay time 90 % to 10 % 2.5 µs ± 0.3 µs Pulse spectrum in line with ICAO Annex 10 Modes X, Y High-power interrogator (R&S EDS-B4 option) Standard ICAO Annex 10, ICAO Doc 8071 Maximum output power DME peak power, into 50 Ω load 500 W (+57 dbm) ± 1.5 db Power steps 100 W, 250 W, 500 W Peak variation coded pulse pair on 50 Ω load < 0.5 db Pulse rate max. 150/s Pulse spacing X mode 12 µs Y mode 36 µs Setting range X/Y mode 11 µs to 42 µs in 0.1 µs steps 0.1 µs Pulse duration 50 % points 3.5 µs ± 0.3 µs Pulse rise time 10 % to 90 % 2.5 µs ± 0.25 µs Pulse decay time 90 % to 10 % 2.5 µs ± 0.5 µs Pulse spectrum in line with ICAO Annex 10 Modes X, Y Inputs and outputs (front) RF 1 IN/OUT RF input/output N connector, 50 Ω RF 2 IN RF input N connector, 50 Ω AF OUT output for headphone 3.5 mm female connector Antenna supply 12 V ± 0.5 V (nom.) USB USB 2.0 double A connector USB stick for data logging, R&S EDS-K1 and software update Inputs and outputs (rear) Analog OUT analog output BNC connector, 50 Ω (nom.) Analog IN analog input BNC connector, 50 Ω (nom.) Trigger OUT trigger output BNC connector, 20 Ω (nom.) Trigger IN trigger input BNC connector, 100 kω (nom.) Suppress IN/OUT input/output for suppressor line BNC connector, 30 kω in (nom.) 0.5 kω out (nom.) Ref 10 MHz IN/OUT BNC connector, 50 Ω (nom.) LAN LAN interface RJ-45, 100BaseT RS-232 RS-232, 9-pin D-Sub connector USB USB 2.0 double A connector USB stick for data logging, R&S EDS-K1 and software update External monitor DVI-D Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer 7

General data Environmental conditions Temperature operating temperature range +5 C to +40 C permissible temperature range 0 C to +50 C storage temperature range 25 C to +70 C Damp heat +25 C/+40 C, 95 % rel. humidity, cyclic, in line with EN 60068-2-30 Altitude operating 4600 m (without external power supply) transport 10000 m (without external power supply) Mechanical resistance Vibration sinusoidal 5 Hz to 55 Hz, 0.15 mm amplitude const., 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 random 10 Hz to 300 Hz, acceleration 1.2 g RMS, in line with EN 60068-2-64 Shock 40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I Power rating Rated voltage base unit 20 V to 28 V DC external power supply 100 V to 240 V AC (±10 %) Rated frequency external power supply 50 Hz to 60 Hz (±5 %) Rated current including R&S EDS-B2 or R&S EDS-B4 5.0 A DC (max.) option external power supply (including R&S EDS-B2 or R&S EDS-B4 option) 1.2 A to 0.5 A AC Product conformity Electromagnetic compatibility Electrical safety EU: in line with EMC Directive 2004/108/EC EU: in line with Low Voltage Directive 2006/95/EC applied harmonized standards: IEC/EN 61326-1, IEC/EN 61326-2-1, EN 55022 (class B) in line with IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-04 VDE-GS, CCSA US, KC Test mark Calibration interval recommended for highest accuracy 12 months for general test and measurement 24 months applications Dimensions W H D 342 mm 157 mm 266 mm (13.46 in 6.18 in 10.47 in) (3/4 19", 3 HU) Weight fully equipped (incl. R&S EDS-B1 and 7.3 kg (16.09 lb) R&S EDS-B4), without external power supply Display 6.5" TFT color display Resolution 800 600 pixel Pixel failure rate < 1.1 10 5 8 Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer

Ordering information Designation Type Order No. Base unit DME/Pulse Analyzer R&S EDS300 5202.7006.02 Hardware options Additional RX Unit R&S EDS-B1 5202.7170.02 Low-Power Interrogator R&S EDS-B2 5202.8160.02 High-Power Interrogator R&S EDS-B4 5202.8177.02 High-Power Amplifier R&S EDS-B5 5202.7193.02 Software options TACAN Analysis R&S EDS-K1 5202.8102.02 Pulse Shape Analysis R&S EDS-K2 5202.8119.02 GPS Synchronization R&S EDS-K3 5202.8125.02 Multi-DME Mode R&S EDS-K5 5202.8131.02 External accessories Rugged transport case R&S EDS-Z2 5202.8202.02 Protection Cover R&S EVS-Z6 5201.7760.00 19" Adapter R&S EDS-Z7 5202.8225.00 Verification Test Dongle R&S EDS-Z10 5202.9980.03 Documentation of Calibration Values R&S DCV-2 0240.2193.24 Warranty Base unit 3 years All other items 6 1 year Options Extended Warranty, one year R&S WE1 Please contact your local Extended Warranty, two years R&S WE2 Rohde & Schwarz sales Extended Warranty with Calibration Coverage, one year R&S CW1 office. Extended Warranty with Calibration Coverage, two years R&S CW2 Extended Warranty with Accredited Calibration Coverage, one year R&S AW1 Extended Warranty with Accredited Calibration Coverage, two years R&S AW2 Extended warranty with a term of one and two years (WE1 and WE2) Repairs carried out during the contract term are free of charge 7. Necessary calibration and adjustments carried out during repairs are also covered. Extended warranty with calibration coverage (CW1 and CW2) Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs 7 and calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades. Extended warranty with accredited calibration (AW1 and AW2) Enhance your extended warranty by adding accredited calibration coverage at a package price. This package ensures that your Rohde & Schwarz product is regularly calibrated under accreditation, inspected and maintained during the term of the contract. It includes all repairs 7 and accredited calibration at the recommended intervals as well as any accredited calibration carried out during repairs or option upgrades. For product brochure, see PD 5214.1220.12 and www.rohde-schwarz.com 6 For options that are installed, the remaining base unit warranty applies if longer than 1 year. Exception: all batteries have a 1 year warranty. 7 Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included. Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer 9

10 Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer

Rohde & Schwarz R&S EDS300 DME/Pulse Analyzer 11

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability Rohde & Schwarz The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and measurement, broadcast and media, secure communications, cybersecurity, monitoring and network testing. Founded more than 80 years ago, the independent company which is headquartered in Munich, Germany, has an extensive sales and service network with locations in more than 70 countries. Certified Quality Management ISO 9001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Rohde & Schwarz training www.training.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 5214.1220.22 Version 04.01 April 2018 (as/ja) R&S EDS300 DME/Pulse Analyzer Data without tolerance limits is not binding Subject to change 2008-2018 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 5214.1220.22 04.01 PDP 1 en 5214122022