ColorBlast Powercore Vibrant, controllable color for interior and exterior architectural lighting

Similar documents
ColorBlast 12 ColorBlast 6 Color-changing LED wash light for use both indoors and outdoors

ColorBlast 12 ColorBlast 6 The original exterior LED wash fixture with intelligent color light

ColorGraze Powercore. Linear, color-changing LED surface light for wall washing and grazing

ColorBlast Powercore The world s leading exterior LED wash fixture with intelligent color light

ColorBurst 6 The original architectural LED spotlight with intelligent color light

ColorFuse Powercore. Linear interior LED wall grazing luminaire with intelligent color light

iw Cove Powercore Compact, intelligent white cove light for brilliantly illuminating interior spaces

ecolor Burst Powercore gen2 Architectural and landscape LED spotlight with solid color light

PureStyle Intelligent Color Powercore RGBA Premium concealed interior linear LED luminaire with intelligent white and color light

ew Accent MX Powercore Direct-view white-light LED fixture with precise resolution control

COLORBLAST 12 POWERCORE

iw Cove MX Powercore Intelligent white cove light for brilliantly illuminating interior spaces

36 High intensity RGB LEDs. UL/C-UL listed, CE. communication Specifications. Environmental Specifications

icolor Tile FX 2:2 Lens sold separately

ColorBurst Powercore gen2 Architectural and landscape LED spotlight with intelligent color light

icolor Accent MX Powercore Direct-view, linear LED fixture with precise resolution control

ArchiPoint. icolor Powercore. Exterior daylight-visible LED point with intelligent color light

DESIGN REVIEW BOARD (DRB) APPLICATION

iw Scene Controller Control intelligent white light fixtures at the touch of a button

ColorBlaze Rugged, full-color linear LED fixture for far-reaching wash lighting and effects

ColorBlaze TR4. Enhanced theatrical and rental LED batten with intelligent RGBW / RGBA light

ColorBlaze Upgrade Kit. RGBW / RGBA upgrade for ColorBlaze industry-standard theatrical and rental LED battens

icolor Accent MX Powercore gen2

icolor Accent MX Powercore Precision-controlled direct view linear exterior LED luminaire with intelligent color light

ew FLEX SLX SPECIFICATIONS Polycarbonate, approx.1.10 x 1.22 x.56 H (2.97 cm x 3.12 cm x 1.4 cm) UL/cUL, CE COMMUNICATION SPECIFICATIONS

icolor Flex LMX Flexible strands of large, high-intensity, full-color LED nodes

ColorBlaze. Rugged, full-color linear LED fixture for far-reaching wash lighting and effects

icolor Flex LMX Flexible strands of large, high-intensity, full-color LED nodes

color range 16.7 million (24-bit) additive RGB colors; continuously variable intensity output range High power colored LEDs Standard MR16 pins

DLE C-201. Actual Size

icolor Flex MX gen2 Flexible strands of high-intensity LED nodes with intelligent color light

icolor COVE LT SPECIFICATIONS output range 110 x 50 Two-piece vented plastic C-UL US Listed, CE certified COMMUNICATION SPECIFICATIONS

iplayer 3 A compact DMX control solution with advanced light show authoring features

icolor Flex LMX gen2 Flexible strands of large high-intensity LED nodes with intelligent color light

Liner Quattro AC XB RGBW

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

ColorBlast RGBA/RGBW Powercore gen4 - Customizable exterior LED flood luminaire with intelligent color light

Product Portfolio LED Lighting Innovations

ColorBlast IntelliHue Powercore gen4 - Customizable exterior LED flood luminaire with intelligent color light

PARĀTA. 724 RGB LED Linear Cove. Introduction. Specifications. Ordering Information

Lumencove Family. The highest quality light from the tightest spaces

Light System Manager gen5. Author, configure, and control intricate LED light shows in multiple zones

Linealux L5 Linear Facade

WLB SERIES HID Lighting for Hose Down Applications

TOKISTAR. TokiLux TOKISTAR LIGHTING

SPECIFICATION SHEET lumencove

Dot XL-6 RGB. Dot XL-9 RGB with

Video System Manager Pro. Deliver spectacular video, imagery, and visual effects to Ethernet lighting networks

Model Material Lamp type LED color Voltage Distribution Lens

Cove Light AC DIM GII

Media Tube CW x 48.5mm 1.12 x mm mm mm kg 5.1lbs. 1.6kg 3.5lbs

POWER MOLE SERIES DA GAO RGBT RADIX

DISTANCE BETWEEN FIXTURES. * 2 " [61mm] on 1ft configuration. 5-year limited warranty.

BLANCA BLS727W White LED Linear Surface

Burst gen2. Product Guide. Spot On. See how our extensive family of high-output spot lighting solutions brightens your world.

IP65. Specifications. White (4 300 K typical) Blue (470 nm) On-site or factory-programmable brightness. Black Silver Polished copper.

Blast gen4. Product Guide. Take flood lighting higher. With versatile luminaires that just keep getting better and brighter.

Exterior 100 IP68 Exterior 50 IP68

Introduction 700ADJ2 - Adjustable Mount. 700ADJ2 Mount. Linear Plan MSL1 MSL2 MSL3 MSL4

Dot XL-6 RGB Dot XL-9 RGB

Media Tube HO RGBW. High intensity SMT RGB and White LEDs Million additive RGB colors; White CCT 6500K

Media Tube HO RGB. 896mm mm mm kg 1.8lbs. 0.4kg 0.9lbs. 1.24kg 2.7lbs. 1.02kg 2.3lbs

Light System Manager. Author, configure, and control intricate LED light shows in multiple zones

SPECIFICATION SHEET lumencove

Dot XL-3 RGB. 3 High intensity Nichia SMT LEDs per dot Million additive RGB colors bit (Gamma correction)

LUNERA SERIES L7 _ GEN 3

Media Tube HO RGBW Million additive RGB colors; White CCT 6500K. Algorithms enable auto control of white LED by 3-channel RGB values.

COLOR POWER SERIES DA CL9 VEGA

Advanced Color Consistency

Dot XL-3 CW/WW is an extra bright dot with 3 high performance LEDs

LENGTH LEAD WIRES LENGTH. Lead wires at one end. Lead wires at both ends. See length ordering guide. Standard is 0975(975mm)

*To meet 1000kg walk over resistance requirements, cement must support 100% of the exterior surfaces of the blockout.

KEEP DISTANCE BETWEEN FIXTURES [14mm] [14mm] 5-year limited warranty.

Woda W7 Underwater Spotlight

lumenfacade Specification Sheet

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

ActiveSite. iplayer 3. Product Guide

*To meet 1000kg walk over resistance requirements, cement must support 100% of the exterior surfaces of the blockout.

Altman Lighting AP-150 RGBW Par Specification

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

XML LED X M L L E D. Explosionproof Linear LED Lighting

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

LUXFLEX PREMIUM THIN & FLEXIBLE BACKLIGHTING. Indoor/Outdoor Series

POWER LINE BAR SERIES DA PL6 WW NORA

VIA 2 LED WALL INDIRECT ASYMMETRIC V. 2 W W W. L U M E N W E R X. C O M

S30-RP LED Soft Light

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

LUXFLEX FLEXIBLE, COLORFUL BACKLIGHTING

Altman Lighting Spectra Cyc 50 Specification

S30-C LED Soft Light LIGHTING - PRODUCT SPECIFICATION V1.0

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

CERTIFICADO No.05884, RETILAP Performance : 13 8 ",25 8 ",37 8 ", 49 8 " [340mm, 645mm, 949mm, 1254mm]

PILOT COVE INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT

LINEAR DOWNLIGHT - PENDANT DIRECT

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

L5-C LED Fresnel L I G H T I N G - P R O D U C T S P E C I F I C A T I O N V2.2

LUXFLEX STANDARD THIN & FLEXIBLE BACKLIGHTING. Indoor Series

FlexElite. Product Guide. Maximum Flexibility. Bring bright, beautiful direct-view LED lighting to structures of all sizes and shapes

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

Transcription:

Vibrant, controllable color for interior and exterior architectural lighting

Vibrant, controllable color for interior and exterior architectural lighting ColorBlast Powercore high-performance LED fixtures combine rich, saturated, wall-washing color and colorchanging effects with simplified installation. offers a single solution for both indoor and outdoor applications, while a range of beam angles make the fixture ideal for washing, grazing, floodlighting, and spot lighting. offers the efficiency and cost-effectiveness of Powercore technology in a rugged die-cast aluminum housing. Low-profile mounting canopy, rotating mounting bracket, and locking fixture rotation offer exceptional versatility. Integrates Powercore technology Powercore technology rapidly, efficiently, and accurately controls power output to fixtures directly from line voltage. The Philips Color Kinetics Data Enabler merges line voltage with control data and delivers them to the fixture over a single standard cable, dramatically simplifying installation and lowering total system cost. Three beam patterns A 23 beam for a softedge, and 8 and 10 beams for extended light projection, support a wide range of lighting applications. Versatile light positioning Locking canopy base offers friction-free rotation of up to 350, and 110 fixture tilting lets you quickly aim the fixture without special tools. Easy installation By delivering line voltage directly to the fixtures, Powercore simplifies installation by eliminating the need for external power supplies, supporting long product runs, and eliminating the need for special wiring. Fixtures can be mounted to a junction box on a wall, ceiling, or floor for maximum flexibility. The canopy base allows for post-installation rotation without precise junction box positioning. Universal power input range ColorBlast Powercore accepts power input of 100 to 240 VAC, allowing the installation of many units in a continuous run. A single Data Enabler can run up to 32 fixtures at 100 VAC, 33 fixtures at 120 VAC, or 52 fixtures at 220 VAC or 240 VAC, installed in series, depending on cable lengths and wire gauge. Industry-leading controls ColorBlast Powercore works seamlessly with the complete Philips line of controllers, including iplayer 3 and Light System Manager, as well as third-party DMX controllers. Efficient and cost-effective Replacing metal halide fixtures with fixtures can dramatically reduce electricity and maintenance costs while delivering superior consistency and uniformity of light and color. Outdoor Rated Fully sealed for maximum fixture life and IP66 rated for outdoor applications, fixtures meet or exceed specifications for use in wet locations. Rugged, die-cast aluminum housing is available in white or black powder-coated finish. FPO 2 Product Guide

Light System Manager Controller Ethernet Controller Keypad Versatile Installation Options offers saturated, color-changing LED light, both indoors and outdoors. With its low-profile design, IP66-rated housing, multiple beam angles, and ease of installation and maintenance, is ideal for applications ranging from backlighting and display and signage lighting to floodlighting, facade- and wall-grazing, architectural detail highlighting, and artistic displays. Philips offers a range of controllers and Data Enablers to support installations from the simplest to the most complex. A simple application might use two ColorBlast Powercore fixtures with a DMX-based Data Enabler and ColorDial controller to dramatically illuminate store window displays with pre-programmed color washes or fades. A larger installation might use Philips Color Kinetics iplayer 3 controller and its ColorPlay 3 light show authoring software to run transformative and imaginative custom light shows on dozens of fixtures installed in multiple interior or exterior locations. Out to additional Data Enabler units or to Ethernet switch, up to 3 levels in total. CAT 5e Cable Ethernet Switch 100-240 VAC ColorBlast Powercore Fixtures Ethernet Data Ethernet Data Enablers Philips Color Kinetics Light System Manager, an Ethernetbased integrated controller and light show authoring system, cost-effectively enables large-scale, complex, and intricately designed installations. The LAX Gateway at Los Angeles International Airport (shown on the cover) uses Light System Manager and approximately 1,800 ColorBlast Powercore fixtures to generate color-changing light within 26 glass pylons ranging in height from 25 to 110 feet. Large-scale Ethernet installation with Light System Manager Large-scale installations may include multiple runs of fixtures controlled by Light System Manager. Each Data Enabler supports a single run of fixtures, and connects to an available port on the Ethernet Switch. Controller Keypad iplayer 3 Controller Serial Cable DMX Data Fixtures 175 ft. (53.3m) maximum individual run length and 400 ft. (122 m) total run length per Data Enabler. Each Data Enabler can support up to 27 fixtures at 120 VAC, DMX Data Enabler 100 240 VAC Small-scale 50 fixtures at DMX 220 VAC, or installation 55 fixtures at 240 VAC with for a single iplayer run, 3 installed with a 6 ft (1.8 m) power/data cable and 1 ft (305 mm) cable between each fixture. Small-scale installations may feature one or more runs of For alternative configurations download the configuration calculator at fixtures http://www.colorkinetics.com/support/install_tool controlled by iplayer 3. Multiple Data Enablers can be connected in series to one or both DMX output ports on the iplayer 3. 100 240 VAC Regardless of the size and complexity of your installation, the planning time you spend up front can help streamline the installation and configuration of your fixtures. Keep these points in mind as you plan your installation: Create a lighting design plan that identifies and locates all fixtures, Data Enablers, and controllers. Use this Product Guide and the online Configuration Calculator to determine whether to install fixtures in series or in parallel, how many fixtures you can install in a single run, and the maximum distances between Data Enablers, fixtures, and controllers. To aid in addressing fixtures for color-changing light shows, record the serial number of each fixture as you assign it to your lighting design plan, and create a layout map that records the address or position of each fixture within a sequence of fixtures. Determine whether to address fixtures and configure your lighting system offline or interactively. With offline configuration, you stage and configure your system off-site, prior to installation. Offline configuration can be convenient when fixtures are to be installed in multiple locations or locations with difficult access. Interactive configuration is typically performed by an experienced technician, after fixtures have been installed. The interactive method can save time, since you connect and test your fixtures only once. Product Guide 3

Photometrics Photometric data is based on test results from an independent NIST traceable testing lab. IES data is available at www.colorkinetics.com/support/ies. 23º Frosted lens Cd: 0 LED Lumens Watts Efficacy RGB 633 50 12.7 R 178 G 348 B 111 Polar Candela Distribution 355 710 1065 1419 1774 2129 VA: 0º 10º 20º 30º 40º - 0º H - 90º H 90º 80º 70º 60º 50º 0 5 15 25 35 45 55 65 75 85 90 0 22.5 45 67.5 90 2128 2128 2128 2128 2128 1851 1853 1851 1852 1853 727 730 734 737 738 241 241 240 241 241 98 97 96 95 95 51 50 50 49 49 30 31 31 30 31 18 17 19 18 19 8 8 8 9 9 1 1 1 1 2 0 0 0 0 0 Illuminance at Distance 3.3 ft 6.7 ft 10.0 ft 13.3 ft 16.7 ft 20.0 ft Center Beam fc 192 fc 48 fc 21 fc 12 fc 7.6 fc 5.3 fc Beam Width 1.4 ft 1.4 ft 2.7 ft 2.8 ft 4.1 ft 4.1 ft 5.5 ft 5.5 ft 6.8 ft 6.9 ft 8.2 ft 8.3 ft Vert. Spread: 23.2º Horiz. Spread: 23.4º Zonal Lumen Degrees Lumens % Lamp % Luminaire 0-30 476.1 75.2% 75.2% 0-40 537.9 85% 85% 0-60 604.6 95.5% 95.5% 60-90 28.3 4.5% 4.5% 0-90 632.9 100% 100% 90-180 0 0% 0% 0-180 632.9 100% 100% Total Efficiency: 100% Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0 RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0 RCR: 0 1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00 1 1.13 1.11 1.08 1.06 1.11 1.08 1.06.94 1.04 1.03 1.01 1.01.99.98.97.96.95.93 2 1.08 1.03.99.96 1.06 1.01.98.88.98.95.93.95.93.91.92.90.89.87 3 1.03.97.92.88 1.01.95.91.83.93.89.86.90.87.85.88.85.83.82 4.98.91.86.82.97.90.85.78.88.84.80.86.82.79.84.81.78.77 5.94.86.81.77.92.85.80.74.83.79.76.82.78.75.80.77.74.73 6.90.82.76.72.89.81.76.70.80.75.72.78.74.71.77.73.71.69 7.87.78.73.69.85.77.72.67.76.72.68.75.71.68.74.70.67.66 8.83.75.69.66.82.74.69.64.73.68.65.72.68.65.71.67.65.63 9.80.72.66.63.79.71.66.62.70.66.62.69.65.62.69.65.62.61 10.78.69.64.60.77.68.63.60.68.63.60.67.63.60.66.62.60.59 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio 10 Clear lens Cd: 0 LED Lumens Watts Efficacy RGB 725 50 14.5 R 212 G 379 B 137 Polar Candela Distribution 1866 3731 5597 7462 9328 11193 VA: 0º 10º 20º 30º 40º - 0º H - 90º H 90º 80º 70º 60º 50º 0 5 15 25 35 45 55 65 75 85 90 0 22.5 44 67.5 90 10179 10179 10179 10179 10179 6611 6682 6917 6999 7082 452 465 484 480 480 141 120 117 116 117 40 29 29 27 26 27 20 19 17 18 23 30 32 29 32 12 5 6 5 6 5 2 1 1 2 0 0 0 0 0 0 0 0 0 0 Illuminance at Distance 3.3 ft 6.7 ft 10.0 ft 13.3 ft 16.7 ft 20.0 ft Center Beam fc 916 ft 229 fc 102 fc 57 fc 37 fc 25 fc Beam Width.7 ft.7 ft 1.3 ft 1.4 ft 2.0 ft 2.1 ft 2.7 ft 2.8 ft 3.3 ft 3.5 ft 4.0 ft 4.2 ft Vert. Spread: 11.4º Horiz. Spread: 11.9º Zonal Lumen Degrees Lumens % Lamp % Luminaire 0-30 651.2 89.8% 89.9% 0-40 671.1 92.6% 92.6% 0-60 715.5 98.7% 98.8% 60-90 9.0 1.2% 1.2% 0-90 724.5 99.9% 100% 90-180 0 0% 0% 0-180 724.5 99.9% 100% Total Efficiency: 99.9% For lux multiply fc by 10.7 Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0 RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0 RCR: 0 1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00 1 1.15 1.13 1.11 1.10 1.13 1.11 1.09.97 1.07 1.06 1.05 1.03 1.02 1.02 1.00.99.99.97 2 1.12 1.08 1.05 1.03 1.10 1.07 1.04.95 1.03 1.01 1.00 1.01.99.98.98.97.96.94 3 1.08 1.04 1.01.98 1.07 1.03 1.00.92 1.00.98.96.98.96.94.96.94.93.92 4 1.05 1.00.97.94 1.04.99.96.90.97.95.92.96.93.91.94.92.90.89 5 1.03.97.94.91 1.02.97.93.88.95.92.90.94.91.89.92.90.88.87 6 1.01.95.91.88.99.94.91.86.93.90.88.92.89.87.91.88.87.86 7.98.93.89.86.97.92.89.85.91.88.86.90.87.85.89.87.85.84 8.97.91.87.85.96.90.87.83.89.86.84.89.86.84.88.85.84.83 9.95.89.85.83.94.89.85.82.88.85.83.87.84.83.87.84.82.81 10.93.87.84.82.92.87.84.81.87.84.81.86.83.81.85.83.81.80 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio 4 Product Guide

Photometrics Photometric data is based on test results from an independent NIST traceable testing lab. IES data is available at www.colorkinetics.com/support/ies. 8 Narrow lens Cd: 0 LED Lumens Watts Efficacy RGB 466 50 9.3 R 137 G 239 B 91 Polar Candela Distribution 1762 3524 5287 7049 8811 10573 VA: 0º 10º 20º 30º 40º - 0º H Zonal Lumen - 90º H Degrees Lumens % Lamp % Luminaire 0-30 414.0 88.9% 88.9% 0-40 441.5 94.7% 94.8% 0-60 460.0 98.7% 98.8% 60-90 5.7 1.2% 1.2% 0-90 465.7 99.9% 100% 90-180 0 0% 0% 0-180 465.7 99.9% 100% Total Efficiency: 99.9% 90º 80º 70º 60º 50º 0 5 15 25 35 45 55 65 75 85 90 0 22.5 44 67.5 90 1051710517105171051710517 3824 3808 3820 3888 3935 366 369 366 362 357 141 120 117 116 117 44 44 42 43 44 16 17 18 18 19 4 5 6 6 7 3 4 4 4 4 2 2 2 2 2 0 0 1 0 0 0 0 0 0 0 Illuminance at Distance 3.3 ft 6.7 ft 10.0 ft 13.3 ft 16.7 ft 20.0 ft Center Beam fc 947 fc 237 fc 105 fc 59 fc 38 fc 26 fc Coefficients Of Utilization - Zonal Cavity Method Beam Width.5 ft.5 ft 1.0 ft 1.0 ft 1.5 ft 1.5 ft 2.0 ft 2.0 ft 2.5 ft 2.5 ft 3.0 ft 3.0 ft Vert. Spread: 8.5º Horiz. Spread: 8.7º Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0 RW %: 70 50 30 0 70 50 30 0 50 30 20 50 30 20 50 30 20 0 RCR: 0 1.19 1.19 1.19 1.19 1.16 1.16 1.16 1.00 1.11 1.11 1.11 1.06 1.06 1.06 1.02 1.02 1.02 1.00 1 1.15 1.13 1.11 1.09 1.13 1.11 1.09.97 1.07 1.05 1.04 1.03 1.02 1.01 1.00.99.98.97 2 1.11 1.08 1.05 1.02 1.09 1.06 1.03.94 1.03 1.01.99 1.00.98.97.97.96.95.93 3 1.08 1.03 1.00.97 1.06 1.02.99.91.99.97.95.97.95.93.95.93.92.91 4 1.05.99.96.93 1.03.98.95.89.96.93.91.95.92.90.93.91.89.88 5 1.02.96.92.89 1.00.95.92.86.94.91.88.92.89.87.91.89.87.86 6.99.93.89.86.98.93.89.84.91.88.86.90.87.85.89.86.84.83 7.97.91.87.84.96.90.86.82.89.86.83.88.85.83.87.84.83.82 8.95.88.84.82.94.88.84.81.87.84.81.86.83.81.85.83.81.80 9.92.86.82.80.92.86.82.79.85.82.80.84.81.79.84.81.79.78 10.91.84.81.78.90.84.80.78.83.80.78.83.80.78.82.80.78.77 RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 Product Guide 5

Specifications Due to continuous improvements and innovations, specifications may change without notice. Item Specification Details Output Electrical Control Physical Beam Angle 8 / 10 / 23 Lumens Color Range Mixing Distance Lumen Maintenance Input Voltage Power Consumption Interface Control System Dimensions (Height x Width x Depth) Weight Housing Lens Fixture Connections Temperature Humidity Fixture Run Lengths Per Data Enabler* 466 (8 beam angle) 725 (10 beam angle) 633 (23 beam angle) 16.7 million additive RGB colors; continuously variable intensity 6 in (152 mm) to uniform light 50,000+ hours L50 @ 50 C (full output) 100 240 VAC, 50 60 Hz 50 W maximum at full output, steady state Data Enabler (DMX or Ethernet) Philips full range of controllers, including Light System Manager, iplayer 3, or other third-party DMX controllers 7.1 x 12.5 x 4.9 in (172 x 317 x 125 mm) 6.4 lb (2.9 kg) Die-cast aluminium, powder-coated finish Clear tempered glass (8º / 10º beam angle) Frosted tempered glass (23º beam angle) 6 ft (1.8 m) unified power / data cable -40 122 F (-40 50 C) Operating -4 122 F (-20 50 C) Startup 0 95%, non-condensing 33 110 VAC 36 120 VAC 52 220 VAC 52 240 VAC Configuration: 20 A circuit, 20 ft (6.1 m) leader cable from Data Enabler to first junction box, 1 ft (305 mm) fixture cables, 2 ft (610 mm) jumper cables 110º 8º Beam Angle 110º 10º Beam Angle 110º Rotation 110º 23º Beam Angle To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from www.colorkinetics.com/support/install_tool/ Certification and Safety Certification LED Class Environment UL / cul, FCC Class A, CE, PSE Class 2 LED product Dry / Damp / Wet Location, IP66 12.5 in 318 mm Lumen measurement complies with IES LM-79-08 Philps Color Kinetics follows IESNA LM-80-08 in using L50 (lumen depreciation to 50% of original light output) to define useful life of RGB LED fixtures. At maximum operating temperature (typically 50 C) and displaying white (full output), the useful life exceeds 50,000 hours. At room temperature and displaying a color wash effect, the useful life ranges from 80,000 to 100,000 hours or more. * These figures, provided as a guideline, are accurate for this configuration only. Changing the configuration can affect the fixture run lengths. 4.75 in 121 mm 1.35 in 34 mm 0.65 in 17 mm 6.5 in 165 mm 7.1 in 180 mm 4.9 in 124 mm 6.5 in 165 mm 3.9 in 99 mm 7.25 in 184 mm 6 Product Guide

STATUS 24 VDC + / - INPUTS 2 3 4 5 6 7 8 SERIAL PORT 2 3 iplayer 3 Fixtures, Data Enablers, and Controllers fixtures are part of a complete system which includes: One or more Data Enablers Included in the box fixture (2) 8-32 screws for indoor installation (4) 10-24 stainless steel screws for outdoor installation 1/8 in hex key wrench for fixture positioning and locking Junction box gasket Installation Instructions Any Philips controller, including Light System Manager and iplayer 3, or a thirdparty DMX controller 4-conductor copper wire to connect fixtures in series or in parallel. Standard 12 AWG (2.05 mm) stranded wire is recommended. Item Housing Color Type Item Number Philips 12NC White 23 Beam Angle 123-000009-00 910503700154 10 Beam Angle 123-000009-04 910503700158 UL / cul 8 Beam Angle 123-000009-08 910503700162 23 Beam Angle 123-000009-01 910503700155 Black 10 Beam Angle 123-000009-05 910503700159 fixtures 8 Beam Angle 123-000009-09 910503700163 23 Beam Angle 123-000009-02 910503700156 White 10 Beam Angle 123-000009-06 910503700160, CE / PSE 8 Beam Angle 123-000009-10 910503700164 23 Beam Angle 123-000009-03 910503700157 Black 10 Beam Angle 123-000009-07 910503700161 8 Beam Angle 123-000009-10 910503700165. Data Enabler (DMX) 106-000003-04 910403326801 Data Enabler (Ethernet) 106-000003-05 910503700064 Light System Manager 103-000015-00 910503700221 iplayer 3, North America Power Cord 103-000019-00 910403327101 You can use any Philips controller or third-party DMX controller. iplayer 3, Europe Power Cord 103-000019-01 910503700392 ColorDial 103-000014-00 910403326901 Synchronizer 103-000001-00 Multi Synchronizer 103-000002-00 Use Item Number when ordering in North America Typical installation For detailed wiring diagrams visit www.colorkinetics.com/support/wiring/ls_prod.html fixtures Controller Keypad iplayer 3 Controller OFF AuxBox AUXBOX PRESETS 4 5 X USB ColorPlay 3 Software Line voltage POWER Fixture Cable Data Enabler DMX Control 1 to fixtures DMX Control 2 to fixtures Product Guide 7

Accessories Designed specifically for the family of Blast fixtures, accessories provide additional options for controlling and dispersing light. Accessory holders snap to the front of the fixture and are required for mounting accessories. Accessory holders prevent accessories from falling out if the fixture is tipped or hung upside down. Item Housing Color Item Number Philips 12NC Accessory Holders White 120-000070-00 Black 120-000070-01 Half Top Hats White 120-000009-03 Black 120-000009-04 Top Hats White 120-000005-03 Black 120-000005-04 Egg Crate Louvers White 120-000015-03 Black 120-000015-04 Barndoors White 120-000019-03 Black 120-000019-04 Horizontal Spread Lens 36 / 50 120-000025-00 Vertical Spread Lens 40 120-000025-01 8 Product Guide

Refer to the Installation Instructions for specific warning and caution statements. To streamline the configuration of complex installations, record the IP address and location of each Data Enabler. Fixture run lengths 33 110 VAC 36 120 VAC 52 220 VAC 52 240 VAC assuming 20 A circuit, 20 ft (6.1 m) leader cable from Data Enabler to first junction box, 1 ft (305 mm) fixture cables, 2 ft (610 mm) jumper cables For more information, and for help calculating the number of fixtures your specific installation can support, download the Configuration Calculator from www.colorkinetics.com/ support/install_tool/, or consult Application Engineering Services at support@colorkinetics.com. Installation offers rich, saturated wall-washing color and color-changing effects with Powercore technology. Powercore, which integrates LED power and data management within the fixture, eases installation by eliminating the need for external power supplies. Owner / User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate fixtures in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance. Installing in Wet or Damp Locations When installing in wet or damp locations, it is good practice to seal all fixtures and junction boxes with electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in wiring compartments, cables, or other electrical parts. You must use suitable outdoor-rated junction boxes when installing in wet or damp locations. Additionally, you must use gaskets, clamps, and other parts required for installation to comply with all applicable local and national codes Create a Lighting Design Plan and Layout Grid 1. Determine the appropriate location of each Data Enabler in relation to the light fixtures, and of the light fixtures in relation to each other. fixtures can be installed in series or in parallel (wired to a common junction box). The maximum number of fixtures each Data Enabler can support depends on specific configuration details such as fixture spacing, circuit size, line voltage, and method of connection (in series or in parallel). As an example, the table to the left lists the maximum number of fixtures each Data Enabler can support at various voltages, assuming a 20A circuit, a 20 ft (6.1 m) leader cable from Data Enabler to first junction box, 1 ft (305 mm) fixture cables, and 2 ft (610 mm) jumper cables between fixtures. Keep in mind that these figures, provided as a guideline, are accurate for the specified configuration only. Changing the configuration can affect the fixture run lengths. In addition to maximum fixture run lengths determined by the electrical configuration, each Data Enabler imposes maximum run lengths based on data integrity. To ensure data integrity, maximum individual run length should not exceed 175 feet (53.3 m), and the total cable length per Data Enabler should not exceed 400 feet (122 m). The maximum cable run length from a Data Enabler to the last fixture in a series, or to each individual fixture in a parallel installation, is 175 feet (53 m). The total cable length in a parallel installation cannot exceed 400 feet (122 m). Fixtures Fixtures Data Enabler Data Enabler Leader Cable connector dimensions.375 in (9.5 mm) 18 AWG.04 in (1 mm) Data Integrity maximum individual length 175 ft (53.3 m) Data Integrity total length 400 ft (122 m) 2. On an architectural diagram or other diagram that shows the physical layout of the installation, identify the locations of all switches, controllers, Data Enablers, fixtures, and cables. Product Guide 9

3. Each fixture comes pre-programmed with a unique serial number. As you unpack the fixtures, record the serial numbers in a layout grid (typically a spreadsheet or list) for easy reference and light addressing. Record fixture serial numbers 4. Assign each fixture to a position in the lighting design plan. 5. To streamline installation and aid in light show programming, you can affix a weatherproof label identifying the order or placement in the installation to an inconspicuous location on each light fixture s housing. Start the Installation 1. Install all Data Enablers, including any interfaces with controllers. Data Enablers and external controllers send power and control signals to the fixtures over the single fixture cable. Additional cabling is required to connect fixtures together in series. 2. Verify that all additional supporting equipment (switches, controllers) is in place. 3. Ensure that all additional parts and tools are available, including: The included 8-32 screws for indoor installations, or the 10-24 stainless steel screws for outdoor installations The included 1/8 hex key wrench The included junction box gasket In the US, one 4 in (102 mm) round US electrical junction box per fixture, rated for your application, with 3.5 in (89 mm) center-to-center screw holes for attaching the fixture s base. (Refer to the junction box manufacturer s literature for additional items required for mounting or sealing.) A sufficient length of 12 AWG (2.05 mm), 4-conductor stranded copper wire Conduit as required Contractor-grade room temperature vulcanizing (RTV) silicone sealant Install the Fixtures fixtures can be installed in series or in parallel (wired to a common junction box). Each fixture requires a dedicated junction box for mounting. Ensure that all junction boxes are suitable for the environment and sealed, if necessary, and that all wiring between junction boxes complies with local codes. COLORBLAST 12 POWERCORE Designed and developed in the USA. Made in Mexico. For complete instructions on how to wire the Data Enabler, refer to the Data Enabler Installation Instructions. Included in the box fixture (2) 8-32 screws for indoor installation (4) 10-24 stainless steel screws for outdoor installation 1/8 in hex key wrench for fixture positioning and locking Junction box gasket Installation Instructions When installing fixtures, the input earth ground, canopy earth ground, and fixture cable earth ground must all be connected together. Item: 123-000009-08 12NC: 910503700162 AGRD eeer DVSR DDwe 25erf 5RDE wpoc 10943 DC: 0852 SCD 1324 1324 22 Make sure the power is OFF before mounting and connecting fixtures. 1. Mount junction boxes in accordance with the lighting design plan. Each fixture is designed for mounting in a 4 in (102 mm) round US electrical junction box, rated for your application, with 3.5 in (89 mm) center-to-center screw holes for attaching the fixture s base. 2. If installing fixtures in a series, pull copper wire between the junction boxes. If installing fixtures in parallel, pull copper wire from a Data Enabler to a common junction box, and from the common junction box to each fixture s junction box. We recommend the use of 12 AWG (2.05 mm), stranded 4-conductor copper wire. With the recommended wiring, the maximum cable run from a Data Enabler to any individual fixture is 175 feet (53 m). When installing in parallel, the total cable length cannot exceed 400 feet (122 m). In locations where US junction boxes are not available, you can mount fixtures directly to a wall or other mounting surface. For help with your specific installation, consult your local support organization, or contact Application Engineering Services at support@colorkinetics.com. Wiring between junction boxes must comply with local codes. 10 Product Guide

Install fixtures in series or in parallel 3. Trim the cable from the fixture to fit in the junction box, leaving enough cable to make wiring connections. 4. Insert the fixture cable through the provided junction box gasket before making wire connections. When attaching the fixture to the junction box, ensure that the gasket is compressed evenly. 5. Use wire nuts to connect line, neutral, ground, and data. 6. Tuck wire connections into the junction box, and use the provided screws to attach the fixture to the junction box. 7. If installing in a wet or damp location, seal all junction boxes with contractorgrade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes. RTV Silicone UL / cul RTV Silicone From Line Voltage L N G D L N G To Fixtures 8. If installing in parallel, connect the wires from each fixture to the lead wire from the Data Enabler in the common junction box. DMX / ETHERNET IN Line Voltage 9. Run the wire from the first fixture to the Data Enabler if installing in series, or run the wiring from the common junction box to the Data Enabler if installing in parallel, and secure connections. CE / PSE To Fixtures From Line Voltage L N G D L N G DMX / ETHERNET IN To Fixtures Data Enabler 5 From Controller (DMX / Ethernet) 3 10. Secure the Data Enabler cover. If installing in a wet or damp location, seal the Data Enabler with contractor-grade RTV silicone sealant. 2 4 6 RTV Silicone 1 Product Guide 11

Attach Safety Cable (optional) Each fixture is designed for use with a safety cable to tether it to a secure anchor point. When dictated by local or state code or advised by a structural engineer, attach a safety cable to the bracket on the back of the fixture. Remove the two screws that attach the cable bracket, loop the safety cable over the cable bracket, and reattach to the fixture. Attach the safety cable to the mounting surface using a method that follows the code or engineer s requirements. Address and Configure the Fixtures Make sure the power is ON before addressing and configuring fixtures. Each fixture has a light address, which controllers use to communicate with the fixture. Each light address corresponds to three sequential DMX addresses, one for red, one for green, and one for blue. fixtures come factory-addressed to light address 1. Safety cable bracket location on fixture Safety cable minimum requirements Material Size Construction 316 Stainless Steel 5/64 to 3/16 in (2 to 5 mm) nominal diameter. Minimum break load must be greater than 400 lb (181 kg) 7 x 7 (49 wires) preformed stranded For lighting designs where fixtures work in unison, all fixtures must be set to the same light address. Changes to the default addresses are not necessary, but if lights were previously readdressed for use in other installations, you must reset them. For light show designs that show different colors on different fixtures, you must assign unique light address to your fixtures and sort them in a useful order. In Ethernet installations, you can you can address and configure your fixtures using QuickPlay Pro with a computer connected to your lighting installation s network. QuickPlay Pro can automatically discover all of your fixtures, controllers, and Data Enablers for quick configuration. In DMX installations, you can address and configure your fixtures using QuickPlay Pro with iplayer 3 or SmartJack Pro. You can manually enter fixture serial numbers, or you can import a spreadsheet listing each fixture s serial number and starting DMX address. You can download QuickPlay Pro from www.colorkinetics.com/support/addressing/ You will need the layout grid that you created when you recorded the serial numbers of the light fixtures in your installation. For complete details on addressing and configuring fixtures, controllers, and power / data supplies with QuickPlay Pro, refer to the Addressing and Configuration Guide at www.colorkinetics.com/support/addressing/. Aim and Lock the Fixtures Using the provided 1/8 in hex key wrench, loosen the rotation and tilting set screws. Aim the fixtures by rotating the base and tilting the beam as desired. Tighten the two pairs of set screws to lock the fixture in place. 110 1/8 in 350 Philips Color Kinetics 3 Burlington Woods Drive Burlington, Massachusetts 01803 USA Tel 888.Full.RGB Tel 617.423.9999 Fax 617.423.9998 www.colorkinetics.com Copyright 2008-2009 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, DIMand, EssentialWhite, ew, icolor, icolor Cove, IntelliWhite, iw, iplayer, Light Without Limits, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice. Cover Photo: Courtesy of Los Angeles World Airports DAS-000008-00 R03 02-09