Technical Specifications Nov 2016

Similar documents
Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

DEREHAM MEMORIAL HALL

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

TECHNICAL SPECIFICATIONS

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

The Haymarket Basingstoke Technical Specifications

New Theatre Royal Lincoln Technical Information

Theatre Technical Specifications

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Dr JOHN GALLAGHER CONCERT CHAMBER

INFORMATION FOR VISITING COMPANIES

Matt Dann Cultural Centre

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

JERWOOD VANBRUGH THEATRE

Technical Specification

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specification Ardhowen Theatre

Main House Technical Specification

Technical Specifications

Technical Information

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

HIRE AND TECHNICAL INFORMATION

TECHNICAL SPECIFICATION

CENTRE FOR PERFORMING ARTS

Technical Specification Pavilion Dance

Technical Specification for the Alley Theatre, Strabane

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Hopgood Theatre NOARLUNGA CENTRE

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Latrobe Performing Arts Centre

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

THE STREET THEATRE. Technical Specifications

RPAC REDLANDS PERFORMING ARTS CENTRE

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical Information

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

The Georgian Theatre Royal Technical Information For Visiting Companies

CHELSEA THEATRE. Technical Specifications

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

ISLAND HALL TECHNICAL INFORMATION

Technical Specification. Updated: April 2016

Technical specifications Main theatre. Sound

Technical Specification

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Stage. Get In & Parking

Concert Hall Technical Specifications

Technical Specifications Updated 01/10/2017. Stage

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Pleasance London Main House Visiting Company Information Pack May 2017

Concert Hall Technical Specifications

Technical Specifications

2017 TECHNICAL SPECIFICATIONS

Technical Data Sheet

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Darlington Hippodrome Technical Specification

Technical Specifications

Main House Technical Specifications

Marjorie S. Deane Little Theater

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

The Anvil Technical Specifications

Summary. Access and Parking

Theatre Technical Specification

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

TECHNICAL SPECIFICATIONS

Technical Specification

Technical Director of Production Andrew Quick Ext 252

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

MAIN THEATRE TECHNICAL SPECIFICATION

UNIVERSITY CONCERT HALL. Technical Specification

Hopgood Theatre NOARLUNGA CENTRE

TECHNICAL SPECIFICATIONS

Patriots Theater at the War Memorial Technical Data

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

John Leslie Theatre. Technical Specifications. Updated July 2018

Technical Specification (Studio Theatre)

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Technical Services and Specification

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Sandusky State Theatre Technical Specifications

SHUBERT THEATER 247 College Street, New Haven, CT

Technical Specification (Studio Theatre)

Jane Mallet Theatre Technical Specifications

Cornerstone Technical Specifications 2018 / V1

Technical Pack. Attenborough Arts Centre

Arlington Arts Tech Spec 2018

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Yan Yean Theatre Technical Specifications

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Technical Specification Ver 01/16

TECHNICAL PACKAGE.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Shouson Theatre Venue Specifications (updated Jan 2017)

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Transcription:

Technical Specifications Nov 2016 November 2016 1

Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The council is runs park and ride buses until 20:00. The cost of this is 3.00 There are a number of side streets where parking is free for the day, all of these are 15-20 mins walk from the theatre. One of the best streets to use is Adams Road, off Grange Road. More information on transport can be found at: http://cambridge.gov.uk/ccm/navigation/transport-and-streets/ Many Thanks The Technical Department For further details on any information contained in this specification, please contact: Mark Passey (Technical Manager) - 01223 578905 mpassey@cambridgeartstheatre.com Tom Bishop (Deputy Chief LX) 01223 578932 tbishop@cambridgeartstheatre.com Harry Chell (Deputy Stage Manager) 01223 578949 hchell@cambridgeartstheatre.com Email: tech@cambridgeartstheatre.com Postal address: Cambridge Arts Theatre, 6 St. Edwards Passage, Cambridge CB2 3PJ November 2016 2

Cambridge Arts Theatre TECHNICAL SPECIFICATION STAGE & MACHINERY Stage dimensions: Width of proscenium 7,800mm (25 7 ) Height of proscenium 4,960mm (16 3¼ ) Depth of stage to u/s of safety curtain 10,000mm (32 10 ) Height of stage from auditorium floor 950mm (3 1 ) Forestage/Pit Lift A front - from front of stage 1,420mm (4 7 ) Forestage/Pit Lift B front - from front of stage 2,400mm (7 10½ ) Forestage/Pit Lift A depth 1,420mm (5 0 ) Forestage/Pit Lift B depth 980mm (3 2½ ) Height to underside of grid 14,690mm (48 3½ ) Height of Scene dock 3,070mm (10 1 ) Width of scene dock door 2,880mm (9 5 ) Diagonal of inner dock door 4,170mm (13 8 ) Flying system: Min. height of bars 1,000 mm (3 3 ) 46 single purchase counterweight bars. (Max. spread load 500kg; max. point load 125kg) 2 single purchase counterweight up-and-down bars (Max. load 500kg; max. point load 125kg) Length of bars 10,200mm (35 6 ) + 900mm (3 0 ) extensions (12000mm total) Max height of bars 14,000 mm (45 11 ) Min. height of bars 1,000 mm (3 3 ) Max point load from the grid: 1 ton per 3m Front of house lighting bridges: Bridge 1 - distance from front of stage 2,800mm (9 2¼ ) Bridge 2 - distance from front of stage 5,100mm (16 9 ) Bridge 3 - distance from front of stage 10,300mm (33 9½ ) Height of FOH bridges above stage level 7,500mm (24 7 ) Circle front lighting bar - distance from front of stage 9,000mm (29 6¼ ) Height of circle front bar above stage level 3,100mm (10 2 ) Temporary Power: Mid-stage Left: 200A TP&N Powerlock connectors. (N.B. - not compatible with Camlocks - adaptors required) 2x 125A TP&N Ceeform 1x 63A TP&N Ceeform 2x 32A TP&N Ceeform Scene Dock (clean earth for sound): 1 x 32A SP&N Ceeform 1x 63A SP&N Ceeform Grid: 2x 32A TP&N Ceeform November 2016 3

Cambridge Arts Theatre TECHNICAL SPECIFICATION STAGE DRAPERIES Soft Masking 1x border, black, 11.5m wide by 1.25m deep 5x borders, black, 11.5m wide by 3.0m deep 1x border, black, 11.5m wide, by 4.0m deep 4x pairs of legs (8 no. total), black, each 2.5m wide by 7.5m deep 4x pairs of legs (8 no. total), black, each 1.25m wide by 7.5m deep 1x pair of tabs (2 no. total), black, pleated, each 6.25m wide by 7.5m deep 1x blackout cloth, black, 11.5m wide by 7.5m deep 1x cyclorama cloth, off-white, 11.5m wide by 7.5m deep 1x black gauze 11.5. wide by 7.5m deep Hard Masking 4 x hard masking flats with black wool serge cover, 1.22m wide by 5.5m high Seating The front two rows of the auditorium (rows A and B) can be removed, in consultation with the staff here. There will be a cost for this. We will presume that the rows will be sold unless we are told otherwise by your company well in advance. November 2016 4

TECHNICAL SPECIFICATION LIGHTING EQUIPMENT LIST The following lanterns are available for use by visiting companies. Fresnels: 35x Strand CantataF (1.2kW) 4x Strand AltoF (2kW) 4x Selecon Arena Fresnel (2kW) PC: 10x Cantata PC (1.2kW) Profiles: 30x ETC Source4 bodies (750W) FOH Bridge 3 12x Source 4 19º 750W (Not movable from bridges) FOH Bridge 2 12x Source 4 26º 750W (Not movable from bridges) ETC Source 4 Lens Tubes: 18 x 19 o 10 x 26 o 14 x 36 o 4 x 50 o Par Cans: 40x PAR64 with CP62 medium flood lamps (1kW) (Some CP60 &CP61 are kept in stock but not sufficient amounts for all units) Floods: 5x Teatro Diluvio 4-cell cyc flood (4x 1kW) rigged on 10m IWB overstage Follow spots: 2x Robert Juliat Foxie 700W HMI Lighting Control: ETC GIO Main Console with ETC ION running tracking backup. Output: DMX512 EC90 Dimmers - 183 x 10A circuits, 15 x 25A circuits. Circuit distribution plan available on request. Please note that stage overhead circuits are via socapex sockets and not 15A. Notes: 1. The 24 Source 4 (750W)listed on the bridges fors our permanent FOH rig (plan available on request). Colour The Cambridge Arts Theatre carries a stock of Lee and Rosco Supergel filters from which a colour call may be prepared in advance at a cost of 50.00 plus costs. November 2016 5

Cambridge Arts Theatre TECHNICAL SPECIFICATION SOUND EQUIPMENT LIST Mixing desks: Main House desk: Yamaha M7CL-48 48x Mono & 4x Stereo Inputs (physical) 24x Outputs (physical) configured as required The M7CL is located in a permanent position in the Sound Control Room at the rear of the Circle and is not moveable. The window of the Sound Control Room slides back for live sound mixing. Moveable desk: Yamaha 03D digital mixer. Dimensions (WxDxH) 460 x 516 x 210 mm 16x inputs (of which 8x mic inputs); 4x bus outputs; 4x aux send outputs; stereo main outputs. The 03D is flight cased and can be moved;. Playback, effects and processing equipment: 2x Denon DN-C635 CD player Installed Loudspeaker Systems 4x d&b audiotechnic 902-LS (2 units each side of the proscenium, one at stalls level one at circle level) 2x d&b audiotechnic 902-LS (permanent centre cluster) 2x d&b audiotechnic C7 sub-bass units (1 each side) 5x d&b audiotechnic E3s (delay speakers underneath the circle) Portable effects/monitor loudspeakers & amplifiers: 8x Electro-Voice SX200 2x JBL Control 1 Tie lines: There are mic and line level tie lines to all areas of the stage, orchestra pit, band room, auditorium and foyers. November 2016 6

Cambridge Arts Theatre TECHNICAL SPECIFICATION SOUND AND COMMUNICATIONS INFORMATION Microphones: 4x Sure SM58 vocal mics 2x Sure SM57 instrument mics 4x Beyer M88 hypercardioid vocal mics 4x Shure SM58 cardiod vocal mics 4x Beyer M201 hypercardioid instrument mics 5x AKG CK91/SE300 cardioid condenser mics 2x Audio Technica AT815b shotgun mics 2x Beyer MCE86 Hypercardioid short-shotgun mics 3x Crown PCC160 supercardioid boundary mics 3x Shure SM91 Unidirectional mics 4x Sennheiser E604 drum mics 1x AKG D112 kick drum mic 4x EMO passive DI boxes 2x MTR passive DI boxes 4x MTR active DI boxes 2x BSS active DI boxes 2x dbx active DI boxes 5x adjustable boom stands 4x adjustable straight stands 4x short adjustable boom stands Radio Microphones: 14x Sennheiser SK500 G3 transmitters with receivers and DPA 4060/4061 mics 2x Sennheiser SKM500 Hand held mics with EW500 G3 receivers Our radio microphones are available for use, and a 75 per mic charge is levied. The system uses either rechargeable AA batteries (in house) or alkaline batteries which must be provided by the visiting company. The use of the radio mic must be pre-arranged with the Chief LX prior to the Get-in. Radio mic licensing: We hold a site licence for the following frequencies: Ch69. Ch38, Ch39, Ch40 for touring equipment (not all frequencies available and are constrained by the Digital Switchover) Ch40, Ch42 and Ch43 Cambridge Arts Theatre Equipment November 2016 7

Mixing positions: There is space in our sound control room or in prompt corner to site a small touring sound desk and associated equipment. There is also a mixing position at the rear of the stalls, the use of which entails the removal of 12 seats. A charge of 200 or the cost of lost seat sales (whichever is the greater) is made for the use of the rear-stalls position (waived in the case of musicals). Communications: Our ring intercom system is standard 3-pin Altair Base Station at Prompt Desk with TechPro belt packs and headsets. Full show relay (audio and video) to all areas. Prompt desk with calls located SL - 14x Q-light circuits (patchable), intercom and video relay. General: We have 6 dressing rooms and a band room. Three dressing rooms are large (up to 8 people) and three are small (2 to 3 people). The band room can be used as 2 dressing rooms if needs be (up to 8 people in each). All dressing rooms (except the band room) have showers and toilets; the band room has toilets only. There is a wardrobe room with washing machine, tumble dryer, iron and ironing board. There is also a visiting company office with outside phone line and internet. Please note that we do not have any on site parking facilities. There is a pay car park for cars only just around the corner from the theatre, but we have no facilities for vans, minibuses etc to be parked near to the theatre. Internet and WiFi connections are available backstage and on stage please ask a member of the Tech Dept for access password. November 2016 8