LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Similar documents
DLD channels LED DRIVERS

DLD channels PRO. Device Manual FEATURES. 1x1400/2000/2800 ma. 4x350/500/700 ma 1x1400/2000/2800 ma. 4x350/500/700 ma 1x1400/2000/2800 ma

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

KNX Dimmer RGBW - User Manual

INSTALLATION & USER GUIDE

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

DALI TOUCHPANEL BASIC TW. Operating and control unit

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Gamma instabus. Technical product information

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

PART 1 PRODUCT (GENERAL)...1.

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Professional-Practice

LAUREL ELECTRONICS, INC.

Instruction manual. DALI Gateway art Installation manual

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

CT-DMX-300 LED Controller

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Emergency lighting units EM powerled

Emergency lighting units EM powerled

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

LED Driver Constant voltage

Luminaire installation box Surface-mounted box Ceiling installation box

DAGON Company Leszno Jackowskiego 24 Street tel DAGON Lighting series SPL-3

Mosaic TM Dimmer 3 x 1000 W

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

LED Driver Compact dimming

DLP200M 2 Relay Module for Heating and Cooling Plants

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

ArteorTM Dimmer 3 x 1000 W / /60

Figure 1: Device components

LT-300 LED Controller

SceneStyle2 User Guide

LED Driver Compact dimming

LED Driver Linear / area dimming

15 Series - Dimmer

SOFT LED 4 Vari-White INSTRUCTION MANUAL

Part No./ 型号 : RGB-Controller-101

Process Transmitter RMA 422

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

Assembly. Front view. LEDs. Parametrization interface. Power Bus

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

ICOLOR210Z. Imported from China by LOTRONIC S.A. Av. Z. Gramme 9 - B-1480 Saintes

LED Driver Compact dimming

02/11/2015

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

DLP600M 6+1 Relay Module for Heating and Cooling Plants

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Cyclo Series. user manual. MartinArchitectural

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

LED Driver Compact dimming

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Local Control Network Function. The LCN-HL4 can be connected to all intelligent LCNI-port test key

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

Flat LED Par Can Light

PRODUCT MANUAL LUMENTO X3 LED. LED Controller ZN1DI-RGBX3. Program Version: 1.0 Manual Edition: a

ABB i-bus EIB Universal dimmer 6155 EB for Installation

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

USER MANUAL. B-EYE Light. Please Read Over This Manual Before Operating The Light Fixture

Linealux L5 Linear Facade

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

OPTOTRONIC Intelligent

LED Driver Compact fixed output

Stratos Duo RGB. User Manual. Order code: EQLED371

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

CAMTO LTD. Arc detecting system DC/AC

QolorFLEX 4x2.5A Dimmer User s Manual Rev 0.18

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

R Rxx-Vxxxx-L334-x

Truss Light COB LED 30W

LEDWash RGBW USER MANUAL

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

2002 Martin Professional A/S, Denmark.

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

ORDER CODE: EQLED65 USER MANUAL

Dimming actuators GDA-4K KNX GDA-8K KNX

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

DMX Channel Index. Revision F Covers firmware version

Transcription:

pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer, dim to warm, tunable white, RGB, Voltage outputs for R-L-C loads Typical efficiency > 95% Adjusting the brightness up to completed off (Dim to dark) Level minimum of brightness: 0.1% (1% in push) D-PWM Modulation Adjusting D-PWM frequency: 300 / 600 / 1200 Hz Adjusting output curve: Linear / Quadratic / Exponential Soft start and soft stop Soft dimming regulation Extended temperature range 100% Functional test 5 Years warranty Constant voltage variants (common anode) Application (4-channels output):, Dim to warm,, RGB, CODE Supply Voltage Output Channels Command DLD1248-4CV-DALI 12/24/48V DC 1x20A max 4x5A max 4 DALI N.O. push button / 0-10 / 1-10 PROFESSIONAL Protections OTP OVP UVP RVP IFP SCP OCP CLP Over temperature protection Over voltage protection Under voltage protection Reverse polarity protection Input fuse protection Short circuit protection Open circuit protection Current limit protection

pag. 2/13 Reference Standards EN 61347-1:2008 +A1:2011+A2:2013 EN 62384:2006+A1:2009 EN 55015:2013+A1:2015 EN 61547:2009 EN 50581:2012 IEC/EN 62386-101 IEC/EN 62386-102 IEC/EN 62386-207 IEC 60929-E.2.1 ANSI E 1.3 Lamp controlgear - Part 1: General and safety requirements DC or AC supplied electronic control gear for LED modules - Performance requirements Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes - EMC immunity requirements Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Digital addressable lighting interface - Part 101: General requirements - System Digital addressable lighting interface - Part 102: General requirements - Control gear Digital addressable lighting interface - Part 207: Particular requirements for control gear - LED modules (device type 6) Control interface for controllable ballasts - control by d.c. voltage - functional specification Entertainment Technology - Lighting Control Systems - 0 to 10V Analog Control Specification Technical Specification Variants Constant voltage Supply voltage Output voltage Output current DC min: 10.8 Vdc.. max: 52,8 Vdc = Vin max 20A 4x max 5 A 1) // max 20 A 1) Nominal power 1) @12V 240 W @24V @48V 480 W 960 W Thermal shutdown 150 C D-PWM dimming frequency D-PWM resolution 300Hz 600Hz 1200Hz 16 bit D-PWM range 0,1% 100% Storage Temperature min: -40 max: +60 C Ambient Temperature 1) min: -40 max: +60 C Protection grade Wiring Mechanical dimensions Packaging dimensions Weight 1) maximum value, dependent on the ventilation conditions IP10 Buttons & Bus: 1.5 mm² solid - 1 mm² stranded - 30/14 AWG Power & Leds: 2.5mm² solid - 1.5mm² stranded - 30/12 AWG 72 x 92 x 62 mm - DIN RAIL 4mod. 124 x 85 x 71 mm 125g

pag. 3/13 Installation See SETUP & INSTALLATION point 4) See appropriate BUS Setup DALI + - Less than 10A: DC IN V+ V- V+ V- 12-48V DC More than 10A: DC IN V+ V- V+ V- IN1 0V IN2 0V IN3 0V IN4 0V DC IN INPUT BUS IN BUS LED DIMMER DLD1248-4CV DC In : 12-48V Out : 4 x max 5A Input : Push/0..10V/1..10V Bus : DMX - DALI - MODBUS + - 12-48V DC See SETUP & INSTALLATION point 1) Mechanical dimension: (without connectors) 71 90,5 6,5 25,5 62 48,3

pag. 4/13 Opening the cover For the Dip-switch and selectors configuration it is necessary to pull up the cover of the device. See the picture. Technical notes Installation and maintenance must be performed only by qualified personnel in compliance with current regulations. The product must be installed inside an electrical panel protected against overvoltages. The product must be installed in a vertical or horizontal position with the cover / label upwards or vertically; other positions are not permitted. It is not permitted the bottom-up position (with the lower face plate / label). Keep separate the 230V circuits (LV) and not SELV circuits from safety extra low voltage (SELV) and all connections for this product. It's absolutely forbidden to connect, for any reason, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit. For power supply use only SELV power supplies with limited current and short circuit protection, and of appropriately sized power. In case of power supplies provided with an earth terminal, ALL protective earthing points (PE = Protection Earth) must be connected to a valid protection earth. The connection cables between the power source and the product must be sized properly and should be isolated from any wiring or live parts not SELV. Use double insulated cables. In the event of higher than 10A total output current to plug into both power input pairs "V +" and "V-". Dimension the power supply for the load connected to the device. If the power supply is oversized compared to the maximum running current, insert a protection against over-current between the power supply and the device. For the constant current outputs, the maximum voltage drop of the LED module (Vf) must be less than the supply voltage of at least 5V. The length of the connecting cables between the local controls (push button, 0-10V, 1-10V, potentiometer, or other) and the product must be less than 10m; the cables must be sized properly and should be isolated from any wiring or live parts not SELV. Use double insulation shielded and twisted cables. The length and type of the connection cables at the BUS (DALI, Ethernet, or other) use cables as per specification of the respective protocols and regulations and they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted cables. All devices and related control signals to the bus (DALI, Ethernet or other) and to the local controls (push button, 0-10V, 1-10V, potentiometer, or other) must be SELV (connected devices must be SELV or otherwise provide a SELV signal). The length of the connection cables between the product and the LED module must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted cables.

pag. 5/13 Function SETUP & INSTALLATION A 12 way dip-switch (under the cover) can provide a rich set of possible configurations: Note: Factory positions = all OFF 1 2 3 7 8 9 10 11 12 Load // Map Curve Input Hz Switches from 1 to 2: Load Type Switch 3: Parallel Outputs Switches from 4 to 6: Map Switches from 7 to 8: Curve Switches from 9 to 10: Input Type Switches from 11 to 12: Output frame rate (freq.) 1) Select Load Type and Parallel Out depending on output connections: Switches from 1 to 2 and Switch 3 Load Type Description Connections (total current 0-10A max) White, up to 4 loads Connections (total current 0-20A max) Settings 1 2 3 White, parallel outputs with increased current (Macro dimmer) 1 2 3, up to 2 loads 1 2 3 WARM COLD WARM COLD WARM COLD WARM COLD, parallel output pairs with increased current 1 2 3 WARM COLD WARM COLD RGB 1 2 R G B R G B 1 2 R G B W R G B W Note: Set the "Select Map" according to the connected load and the function you want. See "Map Setting" page 6.

pag. 6/13 2) Select Map: Switches from 4 to 6 White Load Load RGB Load Load Dim to Warm Dim to Warm Dim to Warm Smart HSV Intensity, temperature correction, color hue & rotation, saturation and strobe RGB Convert RGB Master+RGB+Strobe Master++Strobe Convert RGB Smart HSV Intensity, temperature correction, color hue & rotation, saturation and strobe RGB Convert RGB Master+RGB+Strobe Convert RGB Master++Strobe 3) Select Dimming Curve: Switches from 7 to 8 Default (by bus type) 7 8 Exponential 7 8 Quadratic 7 8 Linear 7 8 4) Select Local Input Type: Switches from 9 to 10 In Type Description Connections Settings N.O. Pushbutton, NO memory Push IN1 0v IN2 0v IN3 0v IN4 0v IN 9 10 N.O. Pushbutton, MEMORY IN1 0v IN2 0v IN3 0v IN4 0v IN 9 10 0-10V Analogic 0-10V 0-10V 0-10V 0-10V 0-10V IN1 0v IN2 0v IN3 0v IN4 0v IN 9 10 1-10V Analogic 1-10V & Potentiometer 1-10V 1-10V 1-10V 1-10V IN1 0v IN2 0v IN3 0v IN4 0v IN 22KΩ 22KΩ 22KΩ 22KΩ IN1 0v IN2 0v IN3 0v IN4 0v IN 9 10 5)Set Output Frequency: Switches from 11 to 12 300Hz 600Hz 1200Hz Reserved 11 12 11 12 11 12 11 12

pag. 7/13 Local commands functionality according to the selected Map Load Type Map IN 1 IN 2 IN 3 IN 4 White up to 4 loads Dim1 Dim2 Dim3 Dim4 White Parallel outs up to 2 loads Dim1 Dim2 Parallel outs up to 2 loads Dim to Warm Dim1 to Warm Dim2 to Warm Parallel outs Dim to Warm to Warm up to 2 loads Tunable White Dim1 CCT1 Dim2 CCT2 Parallel outs Tunable White CCT Dim to Warm to Warm Tunable White CCT Smart HSV CCT Saturation RGB Red Green Blue Red Green Blue White MRGB+ Red Green Blue M+ Red Green Blue White

pag. 8/13 LOCAL INPUTS Available Functions: N.O. PUSH BUTTON memory / N.O. PUSH BUTTON no memory: Dim the light following the selected dimming curve, keeping a constant color temperature. Soft Turn On with 200ms fade time, Soft Turn Off with 1s fade time. Turn ON/OFF light. Double Click: Turn On light at 100% Long pressure (>1s) from OFF: Turn on at 1% (Nighttime) Long pressure (>1s) from ON: UP/DOWN Dim to Warm Dim the light following the selected dimming curve. The color temperature increase with intensity. Soft Turn On with 200ms fade time, Soft Turn Off with 1s fade time. Turn ON/OFF light. Double Click: Turn On light at 100% Long pressure (>1s) from OFF: Turn on at 1% (Nighttime) Long pressure (>1s) from ON: UP/DOWN CCT: Correction Temperature / White Balance - load: change the color temperature, keeping a constant intensity. Neutral white is 50% cold + 50% warm. - RGB load: change the equivalent color temperature. Neutral white is an equal value to R,G,B. - load: balance the white from the white output to the composite RGB output. Neutral white is 50% white + 50% R+G+B. Double Click: Neutral white Long pressure (>1s): Change Colour Temperature UP/DOWN (Cold Warm or White R+G+B ). rotation and selection Change the color or color rotation speed. Double Click: Long pressure (>1s) from ON: saturation: Change the color saturation: vivid colors pastel colors Start/stop color rotation. Change from color (or color rotation) to white and vice-versa. Change the rotation speed, selected from 4 predefined levels. The selected speed is visualized as a white strobo light. Rotation Speed Strobo Pulse 6 seconds 10 flashes/sec. 30 seconds 5 flashes/sec. 6 minutes 2 flashes/sec. 30 minutes 1 flash/sec. Double Click: Long pressure (>1s) from white: Long pressure (>1s) from color: Toggle between white and colors. Maximum saturation - Vivid s. Minimum saturation - Pastel s. Change the saturation value.. Red: linear change red channel. Turn ON/OFF channel. Double Click: Turn On channel at 100% Long pressure (>1s) from OFF: Turn on at 1% Long pressure (>1s) from ON: Dim UP/DOWN Green: linear change green channel. Turn ON/OFF channel. Double Click: Turn On channel at 100% Long pressure (>1s) from OFF: Turn on at 1% Long pressure (>1s) from ON: Dim UP/DOWN Blue: linear change blue channel. Turn ON/OFF channel. Double Click: Turn On channel at 100% Long pressure (>1s) from OFF: Turn on at 1% Long pressure (>1s) from ON: Dim UP/DOWN White: linear change white channel. Turn ON/OFF channel. Double Click: Turn On channel at 100% Long pressure (>1s) from OFF: Turn on at 1% Long pressure (>1s) from ON: Dim UP/DOWN

pag. 9/13 Available Functions: 0-10V / 1-10V / potentiometers: Dim the light following the selected dimming curve, keeping a constant color temperature. Minimum intensity = 0.1%. Below 1V = Turn OFF light. 10V = Maximum intensity. Dim to Warm Dim the light following the selected dimming curve. The color temperature increase with intensity. Minimum intensity = 0.1%. Below 1V = Turn OFF light. 10V = Maximum intensity. CCT: Correction Temperature / White Balance - load: change the color temperature, keeping a constant intensity. Neutral white is 50% cold + 50% warm. - RGB load: change the equivalent color temperature. Neutral white is an equal value to R,G,B. - load: balance the white from the white output to the composite RGB output. Neutral white is 50% white + 50% R+G+B. Change the color temperature from warm (1V), to cold (10V). rotation and selection Change the color. Select a color starting from red (1V), then yellow, green, cyan, blue, magenta and red again (10V). saturation: Change the color saturation: vivid colors pastel colors Change the saturation from white (1V), to vivid colors (10V). Red: linear change red channel. Below 1V = Turn OFF channel. 10V = Maximum intensity. Green: linear change green channel. Below 1V = Turn OFF channel. 10V = Maximum intensity. Blue: linear change blue channel. Below 1V = Turn OFF channel. 10V = Maximum intensity. White: linear change white channel. Below 1V = Turn OFF channel. 10V = Maximum intensity.

pag. 10/13 DALI BUS SETUP In DALI BUS SETUP all the leds are controlled by an external DALI controller. DALI IN1 0V IN2 0V IN3 0V IN4 0V INPUT LED DIMMER DLD1248-4CV-DALI DC In : 12 48V Input : Push, 0/1-10V Out : 4 x max 5A DA DA DALI IN DA DA DALI DADA X DADA X DALI BUS DC IN DALI BUS Reference Standards IEC/EN 62386-101 Digital addressable lighting interface - Part 101: General requirements - System IEC/EN 62386-102 IEC/EN 62386-207 Digital addressable lighting interface - Part 102: General requirements - Control gear Digital addressable lighting interface - Part 207: Particular requirements for control gear - LED modules (device type 6) Onboard led: In the case of no bus power detected, or bus error, the led blinks fast (2 pulsed per second). In the case of bus power but no data, led blinks slow (1 pulse per second). In the case of data link active, the led stands on. Relation with local commands At power-up, in case of absence of connection to the BUS, local control is active. When the BUS is detected, the control passes to the BUS. It remains to the BUS until there is signal. In the absence of signal: - if the local command is N.O. PUSH BUTTON, the control passes to local command in the event of a N.O. push button pressure. - if the local command is 0-10V or 1-10V the control passes immediately to the local command. Addressing By selectors Simplified method (One ballast connected at a time) Random Address Allocation 000 (default): Address defined by DALI DALI from 001 to 064 First channel address, form 1 to 64 FFF (reserved)

pag. 11/13 CHANNELS MAP DALI Load Type: White - up to 4 loads Addr Function Map: +0 1 (Brightness( +1 2 (Brightness( +2 3 (Brightness( +3 4 (Brightness( Load Type: White - Parallel outs (Macro dimmer) Addr Function Map: +0 (Brightness( Load Type: up to 2 loads Addr Function Map: +0 1 (Brightness( +1 2 (Brightness( Addr Function Map: Dim to Warm +0 1 (Brightness( +1 2 Addr Function Map: Tunable white (Brightness( +0 1 (Brightness( +1 Correction 1 Correction Temperature +2 2 (Brightness( +3 Correction 2 Correction Temperature Load Type: Parallel outs Addr Function Map: +0 1 (Brightness( Addr Function Map: Dim to Warm +0 (Brightness( Addr Function Map: Tunable white +0 (Brightness( +1 Correction Correction Temperature

pag. 12/13 Load Type: Addr Function Map: +0 Master Addr Function Map: Dim to Warm +0 Master Addr Function Map: Tunable white +0 +1 Master Correction (Brightness( (Brightness( (Brightness( Temperature Correction Addr Function Smart HSV +0 +1 Master Correction Master (Brightness( Temperature Correction +2 Hue Hue +3 Hue Rotation (rainbow) Time Hue Fine 0 15 Hold 16 25 30min 26.. 51 15min 52.. 76 6min 77.. 102 3min 103..127 +4 Saturation Saturation +5 Strobo Rate fix 0.. 15 blackout 16.. 31 Addr Function Map: RGB 1fps 32.. 47 2fps 48.. 63 3fps 64.. 79 4fps 80.. 95 5fps 96.. 111 6fps 112..127 7fps 128..143 +0 R R +1 G G +2 B B Addr Function Map: +0 R R +1 G G +2 B B +3 W W Addr Function Map: MRGB+ +0 Master 1min 128..153 8fps 144..159 30s 154..179 9fps 160..175 Master (Brightness( +1 R R +2 G G +3 B B 10fps 176..191 15s 180.204 12fps 192..207 6s 205..230 14fps 208..223 16fps 224..239 +4 Strobo Rate fix blackout 1fps 2fps 3fps 4fps 5fps 6fps 7fps 8fps 9fps 10fps 12fps 14fps 16fps fix Addr Function Map: M+ +0 Master Master (Brightness( +1 R R +2 G G +3 B B +4 W W +5 Strobo Rate fix blackout 1fps 2fps 3fps 4fps 5fps 6fps 7fps 8fps 9fps 10fps 12fps 14fps 16fps fix 3s 231..254 fix 240..254

pag. 13/13 DALI COMMANDS STANDARD COMMANDS SPECIAL COMMANDS DIRECT ARC POWER TERMINATE OFF DATA TRANSFER REGISTER UP INITIALIZE DOWN RANDOMIZE STEP UP COMPARE STEP DOWN WITHDRAW RECALL MAX LEVEL SEARCHADDR H RECALL MIN LEVEL SEARCHADDR M STEP DOWN AND OFF SEARCHADDR L ON AND STEP UP PROGRAM SHORT ADDRESS GOTO SCENE (0 to 15) VERIFY SHORT ADDRESS RESET QUERY SHORT ADDRESS STORE ACTUAL LEVEL IN THE DTR PHYSICAL SELECTION STORE THE DTR AS MAX LEVEL ENABLE DEVICE TYPE STORE THE DTR AS MIN LEVEL DATA TRANSFER REGISTER 1 STORE THE DTR AS SYSTEM FAILURE LEVEL DATA TRANSFER REGISTER 2 STORE THE DTR AS POWER ON LEVEL WRITE MEMORY LOCATION STORE THE DTR AS FADE TIME STORE THE DTR AS FADE RATE STORE THE DTR AS SCENE (0 to 15) REMOVE FROM SCENE (0 to 15) ADD TO GROUP (0 to 15) REMOVE FROM GROUP (0 to 15) STORE DTR AS SHORT ADDRESS ENABLE WRITE MEMORY QUERY STATUS QUERY BALLAST QUERY LAMP FAILURE QUERY LAMP POWER ON QUERY LIMIT ERROR QUERY RESET STATE QUERY MISSING SHORT ADDRESS QUERY VERSION NUMBER QUERY CONTENT DTR QUERY DEVICE TYPE QUERY PHYSICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FAILURE LEVEL QUERY FADE TIME / FADE RATE QUERY SCENE LEVEL (0 to 15) QUERY GROUPS 0-7 QUERY GROUPS 8-15 QUERY RANDOM ADDRESS H QUERY RANDOM ADDRESS M QUERY RANDOM ADDRESS L READ MEMORY LOCATION QUERY EXTENDED VERSION