PART 1: HARDWARE Author: Vandermeerschen M. 1 Version 1.07
L 230VAC N 2
LUXOM SEGMENT Power supply 24VDC BUS termination Push Button Feedback without extra wiring I/O Interface BUS RS232 Relay module 230VAC L N 3
LUXOM SEGMENT Power supply 24VDC BUS termination I/O Interface BUS RS232 Relay module 4
LUXOM SEGMENT - CONTROLE Why do we measure Is between S and -? Measured values: Indeen, on the first impression it looks like the buscurrent Is is measured in parallel. This is not the case, you measure the current that is delivered by the bustermination: Note : If you measure for Uv a voltage higher then 3VDC, you must check the + and S wiring in the installation. This high value means that the + and S wiring is somehere in the installation inversed. 5
WIRING Bus wiring with free topology : 3 wires : power and signal wire One central power supply : 24VDC 1 Active bus termination (max. 1 / segment) Use of standard bus cable : Houses : YCYM 2x2x0.8mm², LIYCY 3x0,75mm² Tributaries CS184S Buildings : LIYCY 3x1,5mm² Star Daisy chain Tree Loop 6
WIRING Max. number of BUS modules / segment? : 60 Max. BUS cable length / segment? : 600m (3000ft) More then 60 BUS modules or more then 600m BUS cable? : Use a repeater : A repeater is placed between 2 segments to amplify the bus signals. Every segment must be equipped with a 24VDC power supply and a bus termination. DS41L The repeater is equipped with 2 bus terminations. One for each segment. 7
REPEATER Max. 60 BUS modules & 600m BUS cable Power supply 24VDC Segment 1 Segment 2 Bustermination activated in both segments Power supply 24VDC Max. 60 BUS modules & 600m BUS cable 8
REPEATER Max. 60 BUS modules & 600m BUS cable Power supply 24VDC Segment 1 Segment 2 Bustermination activated in both segments Power supply 24VDC Max. 60 BUS modules & 600m BUS cable 9
REPEATER Power supply 24VDC You can not configure the repeater from the B- side! You need to be connected onto the A-side to set-up the repeater! Power supply 24VDC CAT 5 10
REPEATER Power supply 24VDC OK Power supply 24VDC 11
REPEATER You may never connect several repeaters after each other! 12
REPEATER (BACKBONE) OK 13
INTERFACE Via RS232 Via Ethernet (TCP/IP) RS232 Gateway Ethernet BUS BUS RS232 DS32L DS33L Ethernet Luxom = Always upwards compatible Luxom = Open protocol system Luxom = 2-way control with ASCII commands 14
ETHERNET IP Network IP Network IP Router 15 DSL Wireless Router IP Network IP Network Broadband router with Dyn DNS In an Ethernet network Straight Through internet Wireless
ETHERNET Active bustermination BUS Ethernet CAT 5 16
ADVANTAGES LUXOM NETWORK Very high reliability Simple and fast to extend Decentralized structure is independent of the scale of the installation No expensive central module (lower threshold) Not limited to one technical room Configuration of the modules can be done at a random point and/or wireless in the installation 17
2-WAY COMMUNICATION Ping for and display the status of inputs and outputs Visualisation/feedback without extra wiring Modules constantly listen to each other (broadcast) Up to 80 different commands per second can be handled simultaneously. Fast detection of erroneous configuration 18
ON-LINE/OFF-LINE CONFIGURATION The installation remains 100% usable during configuration A project can be configured entirely off-line Functions can be tested immediately from a computer There are no delays when commanding or pinging outputs Simple testing of logical functions Modifications can be written to the different modules simultaneously 19
OVERVIEW OF THE DIFFERENT LUXOM MODULES 20
INPUTS Dry contacts (NO and NC) Push buttons and toggle switches Voltage signals (5 30VDC NPN or PNP) Wind speed sensor DCF77 signal 0-10V signals Temperature Pulse counters (for energy measurement) Light sensors (0 100000lux) 21
OUTPUTS Dry contacts (16Amp and 10A) 230V contacts (1-fase and 2-fase) Transistor outputs 24V/0.5A Feedback LED (red, blue, white or green) 0-10V (voltage controlled) 1-10V (current controlled) AC motors DC motors 22
Modules - system 23 Active BUS termination + ethernet gateway Active BUS termination RS232 Gateway 24 VA DS24P 60 VA DS60P 96 VA D96P BUS BUS DS01P DS32L BUS DS33L TCP/IP RS232 BUS Power supplies
Modules - input 10 channel I/O Interface 28 ch. RC5 IR Interface DS03L & DS03LX D34L-M 10 ch. binary input module Temperature sensor DS13L DS30L + LU3000 24
Modules cinco 25
Modules cinco European standard 45 x 45 mm Fits Gardy, Niko, Bticino, Legrand UK, 26
Modules - relay 8 + 4 channel relay module 4 channel relay module DS08L OUTLINKS DS04L Multi channel IO module DS88L 27
Modules - controllers 6 ch. motorcontroller + clock 12 ch. 0-10V dimcontroller DS10C-CL CL How many motors/sunblinds? Windspeed meter? Time clocks? Energy measurement? MOODS DS20C How many dimmed outputs? Lightsensor? 28
Modules - add-on relay modules 4 x 10Amp/230VAC 8 x 16Amp/230VAC DS04A dry contact DS18A 1 fase 230V 4 x 5Amp/230VAC DS24A 2 fase 230V 29
Modules - add-on motor modules 2 x 10Amp/230VAC 4(2+2) x 5Amp/230VAC 4 x 5Amp/30VDC DS34A AC DS30A DC 30
Modules - add-on dimmer modules 4 x 2.5A/230VAC 4 x 10A/230VAC DS704A Totaal max. 2.4kW DS70A Totaal max. 9kW 31
Modules - add-on dimmer modules 4 x 1/10V (fluorescent) Add-on connection block with screw terminals DS44A DS36D 32
DS 04A 4 x 10A / M 2 AC INTERCONNECTIVITY DS 08L DS 20C DS 10C DS 88L DS 24A DS 18A DS 34A DS 30A DS44A 4 AC 4 DC 4 x 5A 8 x 16A M M 4 x 1/10V DS70A DS704A 4 x 10A (RLC dimmer) 4 x 2.5A (RLC dimmer) 33
Modules 2 channel 230VAC interface Motion detector Wall 24VDC 360 Fits in European 45x45 LU0501 LU0400 Adaptor for ceiling mount LU0401 34
Modules 1 channel lightsensor (with 0-10V uitgang) DCF77 receiver LU0201 LU0701 35
Modules Control panel 32 buttons In-wall box for MT132 MT132 LU1032 Wall mount box for MT132 Faceplate for MT132 LU1033 LU040x DS70A 36
WIRING DIAGRAM SENSORS 37
Connecting binary inputs DS13L 10 DS10C-CL DS20C DS04L 5 5 5 DRY CONTACT PNP & NPN SENSORS 5 30VDC Max. 100m DS88L 24 38
Connecting analog 0-10V inputs DS20C + LU0201 10 levels incl. logical functions 39
Connecting windspeed sensor DS10C-CL + LU0101 40
Connecting pulsecounter DCF77 DS10C-CL DS10C-CL + LU0701 41
PROJECT EXAMPLE 42
Project - outputs Ground floor : -7 dimmers 0/10V -3 dimmers 1/10V (RGB) -1 sunblind -7 lights on/off -1 fan on/off -2 Plug sockets First floor : - 18 lights on/off - 2 fans on/off - 1 dimmer 0/10V - 1 dimmer 1/10V 43
Project : Electrical cabinet 44
Project : Electrical cabinet : Light switches 45
Project : Electrical cabinet : Light switches : Motion sensors 46
Project : Electrical cabinet : Light switches : Motion sensors : Modules DS03LX 47
Project : Electrical cabinet : Light switches : Motion sensors : Modules DS03LX : IR module DS34L-M 48
Project : Electrical cabinet : Light switches : Motion sensors : Modules DS03LX : IR module DS34L-M : Bus cable YCYM 49
Project : Electrical cabinet : Light switches : Motion sensors : Modules DS03LX : IR module DS34L-M : Bus cable YCYM : Bus cable for light switches YCYM (max. 3 switches/push buttons with YCYM 2x2x0.8mm² buscable) Free topology buswiring to all modules in every room, Star wiring in every room to all switches. 50
Project : Electrical cabinet : Light switches : Motion sensors : Modules DS03LX : IR module DS34L-M : Bus cable YCYM : Bus cable for light switches YCYM : Motion sensor 230VAC with interface LU0501 51
Project : Electrical cabinet : Light switches : Motion sensors : Modules DS03LX : IR module DS34L-M : Bus cable YCYM : Bus cable for light switches YCYM : Motion sensor 230VAC with interface LU0501 Motion sensor 230VAC 52
Project modules used h = Reserve 1 st floor a b c a b c g Groundfloor DS03LX g DS34L-M e d e f d f 53
Project modules used - 1x DS60P Bus power supply 2.5A 1x DS65L Ethernet gateway - 2x DS08L 8 + 4 channel relay module - 1x DS34L-M Infrared receiver - 1x DS20C 12 channel dimcontroller - 1x DS10C-CL 6 channel motorcontroller with clock 11x DS03LX 10 channel I/O event module - 1x DS44A 4 channel add-on 1/10V fluo interface - 1x DS18A 8 channel add-on relay module - 2x DS704A 4 channel add-on dimmer - 2x DS04A 4 channel add-on dry contacts 1x LU.0201 1 channel lightsensor 1x DS20D Connecting wires 20cm for DS03L (100x) 1x DS33D Add-on cable 50cm (10x) 1x LU0501 2 channel 230VAC interface 4x LU0400 Motion sensor 360-24VDC Led lighting 54
HOME AUTOMATION? 55
Flexibility Safety Comfort Rational energy management Simple 56
FLEXIBILITY Easy and fast to adjust Tailored to the home owners needs Keeps future developments in mind Adjusts to a changing family situation Longer independency for seniors 57
SAFETY Detection of irregularities Fire and burglar alarm compatible Technical malfunctions are spotted faster Panic button Switching off power outlets (Garden, kitchen sink, ) 58
COMFORT Group commands Individual commands for each family member Heating controls per zone or room Lighting moods Less to worry about 59
RATIONAL ENERGY MANAGEMENT Light management in function of day light conditions Control of power usage Safety against extreme peak usages Using sunlight / sun warmth to a maximum degree Heating 60
SIMPLE Simple, easy to handle hardware No complex wiring Less components to worry about Changing a function does not mean changing the wiring Teaching the system macros 61
ADVANTAGES - Offer more possibilities, easier wiring and more value/functions for money. - Control, signal and take action when necessary - Provide easy to handle controls, comfortable living and a considerable gain in time - Allow for controlled power consumption: - where needed, - as much and as long needed, at the exact right power level - at the lowest rates - Offer added value, higher profits and differentiation in respect to your competitors 62