Model Number Structure

Similar documents
E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Accessories (Order Separately)

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Model Number Structure

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Multifunction Digital Timer

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Type Contact form Model

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Metal Electrode Meter

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Global Water Instrumentation, Inc.

Instruction Manual Model # Block Upconverter

Electronic M.O.P Card. Instruction Manual Model D

Magnecraft Power Relays

EZ-LIGHT K30L Series With Independent Push Button Contact

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Model: UHD41-ARC. Installation Guide

1X4 HDMI Splitter with 3D Support

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Self--powered Time Counter

Magnetic and Hydraulic-Magnetic Circuit Breaker

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Model /29S RF Splitter

Instruction Manual Model BlockUpconverter

Kuhnke Technical Data. Contact Details

3G/HD/SD-SDI to HDMI Converter

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

Model R177M and R177S Baseband Switch

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

American Power Design, Inc.

Solid-State Digital Timer


EZ-LIGHT K90FDL Daylight Visible

Model: HDCMP31. Installation Guide

WLS27 Multicolor LED Strip Light with EZ-STATUS

Installation Manual SaVi Note Underwater LED Light

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Indicator (Square) Ultra Bright LED Type

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Photoelectric Sensors E3F2

Absolute Rotary Encoder E6CP

Series CT7N Bimetallic Overload Relays

USB-TG124A Tracking Generator User Manual

Model P/03P Upconverters

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

True RMS AC/DC Mini Clamp Meter

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

34MD Series. Motor/Driver Combination. User s Guide E. Landon Drive Anaheim, CA

Digital Lighting Systems. DIGTAN4-PRO Converts 4 PROTOCOL channels to 4x 0.5 V to 10 VDC Analog

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

Instructions. P MHz 1X/10X Passive Probe

Keysight 16048G/H Test Leads

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

CVSB/ S-video/ HDMI to HDMI Scaler with 720p and 1080p Switching.

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

OPERATION AND MAINTENANCE MANUAL

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

User Manual. Model 979T and 979R Digital Audio Converters

3M Sensored Termination (15 kv) QX-T15I-vi1-E

WIRING INSTRUCTIONS CROP-LINK Drip Installation

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

User s Manual. Model Digital Sound Level Meter

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Transcription:

Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control with little noise. Used in combination with the to connect to single- and three-phase loads. Three types of input method available: Internal adjuster, external adjuster, or DC signals from 4 to 20 ma. Streamline design. Both DIN track mounting and screw mounting possible. Use linking terminals for close mounting of the. Built-in isolation transformer. Power supply range: 100 to 240 V. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend -US 1 2 3 1. Basic Model Type G32A: Accessory for 2. Basic Model Name EA: Cycle Control Unit 3. Certification US: Certified by UL and CSA Ordering Information List of Models Name Isolation transformer Rated power supply voltage Model Cycle Control Unit Yes 100 to 240 VAC -US Accessories (Order Separately) External Variable Resistor G32A-E-VR Model 1

Specifications Ratings (at an Ambient Temperature of 25 C) Rated power supply current Output signal Characteristics Engineering Data 50 Hz 100 to 240 VAC 40 ma max. 60 Hz 100 to 240 VAC 20 ma max. at 12 VDC ±15% (at 25 C) Input signal Current signal: 4 to 20 ma (input impedance: 352 Ω) Internal adjuster: 50 kω (1/4 W) External adjuster: 50 kω (1/4 W) Output cycle rate 0 to 100% Control cycle 0.2 s Number of operable Units 3 -VD Relays max. Power supply voltage range 75 to 264 VAC Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute (between AC power supply and input/output terminals) Insulation resistance 100 MΩ max. (at 500 VDC) Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (when mounted to DIN track) Shock resistance 300 m/s 2 (approx. 30 G) Storage temperature 30 to 100 C (with no icing or condensation) Ambient temperature 30 to 80 C (with no icing or condensation) Ambient humidity 45% to 85% Weight Approx. 100 g Output Cycle Rate vs. Setting Value Output Cycle Rate vs. Control Current Output cycle rate (%) Output cycle rate (%) Setting value Control current 2

Nomenclature The following diagram shows the terminals, adjusters, and switches on the. Input terminal C2 Control method External adjuster Input selection slide switches Input terminal C1 + Output terminal (B1) + Internal adjuster (See note 2.) 4 to 20 ma Input selection slide switches Internal adjuster Output terminal (B2) Control current 4 to 20 ma AC power supply terminal (A1) 4 to 20 ma Setting the Input Method AC power supply terminal (A2) Select external adjuster, internal adjuster, or control current as the input method using the selection switches as shown in the following table. Note: 1. The input selection slide switches are factory-set to internal adjuster input. Change the setting of the switches for the input method required. 2. When using the internal adjuster, use with the input terminals (C1, C2) in the open state. Internal setting is not possible if there is a Temperature Controller or other device connected to C1 or C2. 3

Cycle Control Setting Method The output cycle rate can be adjusted using the internal or external adjuster. For current control, refer to the Output Cycle Rate vs. Control Current graph on page 2. Note: When using the internal adjuster or external adjuster, it is necessary to set the input control method in the way described previously. VR setting Output cycle rate (%) Note: The resistance is 50 kω at 100% and 0 Ω at 0%. Control cycle: 0.2 s Output Power Resolution When power is controlled using the Cycle Control Unit, the output resolution (minimum variation value) depends on the half cycle of the power supply frequency and the time depends on the power supply frequency. (SSR with zero cross function) Control cycle Output power resolution 50 Hz 60 Hz 0.2 s 5% (10 ms) 4.2% (8.3 ms) Control cycle: 0.2 s Cycle Control Method The power on the load side can be controlled by adjusting the number of cycles within the control cycle of 0.2 s and repeating this control cycle. Electric furnace temperature 20 ma 12 ma Current control input 4 ma Output signal 50 Hz: 5% (10 ms) 60 Hz: 4.2% (8.3 ms) Control cycle: 0.2 s 4

Operation Application Examples High-precision temperature control can be achieved in combination with the. Current signal DC, 4 to 20 ma Internal adjuster 3 Relays max. -VD 10 to 60 A G32A-E-VR External Adjuster 1. Control Using Current Input 3. Control Using Internal Adjuster NFB Current output Temperature Controller NFB A1 A2 A1 A2 G32A-D Hard-wired heaters 2. Control Using External Adjuster External resistance NFB A1 A2 G32A-D Hard-wired heaters Applications 1, 2, and 3 each use a different type of input method and so it is necessary to change the settings of the input selection slide switches. Be sure to change the slide switch settings in accordance with the input method on page 3. Note: 1. For details of input selection slide switch settings, refer to Setting the Input Method. 2. The above examples are for when a -VD (except 60-A models) is used at 200 VAC. 3. When performing ON/OFF control for example 2 or 3, do not connect output terminals B1 and B2 on the to input terminals A1 and A2 of the SSR as linking terminals, Rather, connect contacts between these terminals for switching. The current flow is 20 ma max. at 12 VDC. G32A-D Hard-wired heaters 5

External Adjuster G32A-E-VR The external adjuster, its adjuster knob, and its nameplate, all come in a set (G32A-E-VR). External Adjuster (50 kω, B Characteristic) 20±1 dia. 1 M9P 0.75 0 6-0.1 dia. 1±0.2 2.8±0.2 dia. 7.5±0.4 When wiring, connect in the way shown below. 20 min. 10±1 1.5 min. 20 9.5±0.5 1.6±0.2 20 max. Mounting Holes 7.5±0.4 Less than 3 m 9.5 dia. 3 dia. Note: Wire the external adjuster at a distance of less than 3 m. Nameplate 44 dia. Note: When using the external adjuster for input, be sure to set the input selection slide switches accordingly. Knob Filled with white resin 6

Dimensions Note: All units are in millimeters unless otherwise indicated. -US Six, M3.5 terminal screws 8.6 4.5 Linking terminal +B1 Internal adjuster 64 Selection switch 100 max. 90±0.3 80 Linking terminal B2 4.6 5.6 elliptic hole 20 max. 23.7 Without Terminal Cover With Terminal Cover 100 max. 3.5 Terminal Arrangement/ Internal Connection Mounting Holes Two, 4.5-dia. or M4 holes Cycle control 90±0.3 Safety Precautions Refer to Safety Precautions for All Power Controllers. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 7

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2014.4 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2014 All Right Reserved.