Flag System Drop Feeding

Similar documents
Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

Chore-Tronics 2 Breeder Edition Override Box

TV Lift System Model CL-65 Installation Instructions

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

OWNER'S MANUAL SIGNAL COMMANDER

2178-L/S Series Fiber Optic Splice Case with Gasket

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Viztrac AM200 User s Guide. Page 1 of 12

Metal and Glass TV Stand for TVs up to 65 or 110 lbs. NS-HMG1856

Move & Store Cart CONTENTS. Assembly Instructions

Indoor/Outdoor Analog Wired Camera Model P-520 USER'S MANUAL

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

OPERATION AND MAINTENANCE MANUAL

OWNER'S MANUAL SIGNAL COMMANDER

Indoor/Outdoor Security System with Quad Monitor User s Manual

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide


Installation Manual SaVi Note Underwater LED Light

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

SyncGen. User s Manual

Passive Four Channel Stereo/Mono Mixer/Splitter. Artcessories. User's Manual

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

USER S MANUAL. Save this manual for future reference. For a digital version of this manual, visit

User Instructions. 16 SCB Sync Station.

VK-P10SE WARRANTY REGISTRATION FORM

75 Elliptical Antenna System

APSPB PUSH BUTTON ZERO Installation Manual

Caution. Hanging the Screen:

Z100 / Z300 Z500 Z700 OWNER S MANUAL PLEASE CAREFULLY READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW ELLIPTICAL!

Operation Manual VMS 3.0 Video System

In-Wall Control Mount for ipod Touch

V74 INSTRUCTIONS INSTALLATION VESA 700X400 FIXED WALL MOUNT ISSUE 002

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

A CENTIMETER FM YAGI ANTENNA MHz

AWT150C/AWT150CS/ AWT151C CCD Camera

QCA9-33 Active Combiner

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor

OWNER'S MANUAL SIGNAL COMMANDER

SD/HD-SDI 1 to 2 Distribution Amplifier VCF-1002DA-P

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

SC-C1M SiriusConnect TM Vehicle Tuner

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

LWX-1. Satellite Weather Radio Module Installation Instructions A

LIGHT COPILOT II. elationlighting.com Internet:

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

AB CRUNCH SIT UP BENCH MODEL# 8642AB PRODUCT MANUAL - VERSION

Electric Motorized Projection Screen PowerMax Tension Series

ASP-FIBRS1 User Manual

Issue date : 9/11/00. Rogue Audio Tempest Vacuum Tube Integrated Amplifier. Owners Manual. Vacuum Tube Amplifiers

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

DisplayPort Extender over 2 LC Fibers

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

WINEGARD. TRAV LER Automatic Multi-Satellite TV Antenna. Model SK-3003 DIRECTV TRIPLE FEED INSTALLATION MANUAL. Made in the U.S.A.

B2590/65SNZ. Crank-Up. Installation & Operation Instruction Manual NZ Iss 1

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Electric Motorized Projection Screen Spectrum Series

TRF STEP-DOWN TRANSFORMER USER MANUAL

Quick Installation Guide TV-H110 H/W: V1

Instructions. P MHz 1X/10X Passive Probe

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

The Phono Box SUMIKO Fifth Street Berkeley, CA sumikoaudio.com

Install Guide Incredible Technologies, Inc. All Rights Reserved

QDA4-44 RF Amp/Combiner

Backlight Replacement

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

PARTS LIST FOR CM-1250-A/C 1.5 HP

Specifications. Compatible Receivers. Compatible Satellites. DIRECTV Sat DISH Sat DIRECTV Receiver Compatibility

DISH Pro Hybrid 42 Switch Installation Guide

MP-7424 Football Scoreboard with MP5000 Console

Quintet SL. Owner s Manual

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

TS2.8 Sub OWNER S MANUAL

Installation Note. Agilent 89441A Option AYC Installation Kit

MARINE HORNS V-1030M - 5 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1036M - 15 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1048M - 45 OHM TALKBACK HORN

AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS

RK-1T2PT, RK-2T1PT, RK-3T, RK-3T-B, RK-6T, RK-9T, RK-3TR, RK-4PT, RK-4PT-B, RK-T2B, RK-T2B-B, RK-T2SB, RK-T2SB-B

Warner Photoscanner MCS-500 Series LED Photoelectric Control

User s Guide. Manufactured by: BlissLights Phone: (626) Fax: (626)

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

LED Thunder S-150 Code 1097

Sprite TL Quick Start Guide

Electric Wall/Ceiling Projection Screen Saker Series User s Guide

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

INSTALLATION GUIDE. Axle Weighing Truck Scale. 60,000 lb x 20 lb Factory Calibrated Includes Pre-interfaced Wireless Remote LED Scoreboard Displays

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

WINEGARD TRAV LER Automatic Multi-Satellite TV Antenna

ServerCall Transmitter

Industrial Monitor Update Kit

Transcription:

Flag System Drop Feeding Installation & Operator s Manual warranty installation parts list November 1997 MA1015C

WARRANTY INFORMATION Chore-Time equipment warrants each new product manufactured by it to be free from defects in material or workmanship for one year from the date of initial installation by the original purchaser. If such a defect is found by Chore-Time to exist within the one year period, Chore-Time will, at its option, (a)repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. Additional extended warranties are herewith provided to the original purchaser as follows: 1. RLX Fans, less motors, for three years from date of installation. *2. Poultry feeder pans that become unusable within five years from date of installation. Warranty prorated after three years usage. 3. MEAL-TIME Hog Feeder pans that become unusable within five years of installation. 4. Rotating centerless augers, excluding applications involving High Moisture Corn (exceeding 18%), for ten years from date of installation. Note: MULTIFLO and applications involving High Moisture Corn are subject to a one year warranty. 5. Chore-Time manufactured roll-formed steel auger tubes for ten years from date of installation. *6. Laying cages that become unusable within ten years. Warranty prorated after three years usage. *7. ULTRAFLO Auger and ULTRAFLO Feed Trough (except ULTRAFLO Trough Liners) are warranted for a period of five (5) years from date of original purchase against repeated breakage of the auger or wear-through of the feed trough. Conditions and limitations: 1. The product must be installed and operated in accordance with instructions published by Chore-Time or warranty will be void. 2. Warranty is void if all components of a system are not supplied by Chore-Time. 3. This product must be purchased from and installed by an authorized Chore-Time dealer or certified representative thereof, or the warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under this warranty. 5. This warranty applies only to systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this warranty. Chore-Time shall not be liable for any consequential or special damage which any purchaser may suffer or claim to have suffered as a result of any defect in the product. "Consequential" or "special damages" as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES CHORE-TIME S ENTIRE AND SOLE WARRANTY AND CHORE- TIME EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIM- ITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PAR- TICULAR PURPOSE SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Any exceptions to this warranty must be authorized in writing by an officer of the company. Chore-Time reserves the right to change models and specifications at any time without notice or obligation to improve previous models. *See separate "WARRANTY ADDITION" as to these products CHORE-TIME EQUIPMENT, A Division of CTB, Inc. P.O. Box 2000, Milford, Indiana 46542-2000 U.S.A. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 2

Support Information The CHORE-TIME Flag Drop Feeding System is designed to convey livestock feed types. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury and/or death. This manual is designed to provide comprehensive planning, installation, wiring, and parts listing information. The Table of Contents provides a convenient overview of the information in this manual. The Table of Contents also specifies which pages contain information for the sales personal, installer, and consumer (end user). IMPORTANT: CE stands for certified Europe. It is a standard which equipment must meet or exceed in order to be sold in Europe. CE provides a benchmark for safety and manufacturing issues. CE is required only on equipment sold in Europe. CHORE-TIME Equipment recognizes CE Mark and pursues compliance in all applicable products. Please fill in the CE-Mark serial number in the blank space provided for future reference. (CE-mark serial number) Please include the names and address of your CHORE-TIME Distributor Please fill in the following information about your Chore-Time Flag Drop Feeding System. Keep this manual in a clean, dry place for future reference. Distributor s Name Distributor s Address Distributor s Phone Installer s Name Installer s Address Installer s Phone System Specifications Feed Delivery System Supplying Date of Purchase Date of Installation 1. Regular Screwdriver 2. Allen Wrenches 3. Box-End Wrenches 4. Drive Ratchet and Sockets 5. Locking Pliers 6. File 7. Saw to cut PVC Tubes 8. 1.5, 2.5, or 3" Hole Saw or Sabre Saw 9. Screw-Hook Driver 10. Bolt Cutters or Hack Saw Tools needed to install your Flag System include: CHORE-TIME FLAG Drop Feeding System Installation Manual Page 3 11. PVC Cleaning Solvent 12. Wire Cutters 13. Wire Strippers 14. Adequate Size and Quantity of Electrical Wire 15. Electrical Drill and Drill Bits 16. Abrasive Cut-off Saw (for steel systems only) 17. Oxy-Acetylene Torch and Brazing Rod 18. Another person to help!!

Table of Contents Topic Page User* Warranty Information... 2 Support Information... 3 Tools needed to install your Flag System include:... 3 Related Instruction Manuals... 4 Safety Information... 5-6 Introduction... 6 Fill System Power Unit Selection Guide (in feet)... 7 Fill System Power Unit Selection Guide (in meter)... 8 Installation... 9-11 Wiring the System... 11 Setting the Delay... 11 Alternate Flag System Layout Diagrams (#1 through #4)... 12-13 Flag System Wiring Diagrams... 14-26 Parts List... 27-29 C, D C, D I C, D, I C, I C, I C, I C, I I I C, I C, D, I I C, D, I *Legend: C = Customer (end user), D = Distributor (sales), I = Installer of equipment Related Instruction Manuals Inst. No. Two Motor Tandem System Manual (Model 75, 90, HMC) Circulating Feed Delivery System Manual (Model 75, 90, HMC) Extended Length System Manual (Model 75, 90, HMC) AGRI-TIME Digital Time Clock Manual Interval Timer Manual Model 55, 75, 90, & HMC FLEX-AUGER Fill System Manual Proximity Drop Tube Switch Instruction Mechanical Drop Tube Switch Instruction Proximity Boot Switch Instruction Drop Feeding Installation Manual MA524 MA773 MA709 MF1115 MA951 MA1000 MA1044 MA1099 MA1060 MA854 Note: Some of the instructions listed above are available in various languages. Contact your CHORE- TIME Distributor for additional manuals. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 4

SAFETY INFORMATION Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety signs. Using the equipment for purposes other than specified in this manual may cause personal injury or damage to the equipment. Safety Alert Symbol This is a safety alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. CHORE-TIME equipment is designed to be installed and operated as safely as possible...however, hazards do exist. Signal Words Signal words are used in conjunction with the safety alert symbol to identify the severity of the warning. DANGER...indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. WARNING...indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. CAUTION...indicates a hazardous situation which, if not avoided, MAY result in minor or moderate injury. DANGER WARNING CAUTION DANGER: MOVING AUGER This decal is placed on the Clean-Out Cover of the FLEX-AUGER Control Unit. Severe personal injury will result, if the electrical power is not disconnected, prior to servicing the equipment. DANGER: ELECTRICAL HAZARD Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 5

SAFETY INFORMATION CAUTION Use caution when working with the Auger. Springing auger may cause personal injury. Introduction: The CHORE-TIME Flag System is designed to be used in installations that have one Fill System supplying several lines of feeders, as shown in Figure 1, on page 9. The Alternate Flag System Layout Diagrams on pages 12 and 13 show alternative Fill System layout options. The Flag System uses a Model 75 or Model 90 FLEX-AUGER Fill System to supply two or more Flag Feeder Lines. A Delay/Relay Kit is recommended for use on flag fill systems to avoid potential short cycling. The FLEX-AUGER Fill System supplying the Flag System must be sized properly to provide enough feed, without over-charging the system. The following chart specifies the feed delivery rates of the Model 75 and Model 90 FLEX-AUGER Fill Systems operated at 216 RPM, 348 RPM, and 425 RPM. Feed Delivery System Capacities Model 75 Model 90 216 RPM 30 lbs./min. 13.6 kg./min. 60 lbs./min. 27.2 kg./min. 348 RPM 50 lbs./min. 22.7 kg./min. 100 lbs./min. 45.4 kg./min. 425 RPM 60 lbs./min. 27.2 kg./min. 120 lbs./min 54.4 kg./min. The feed delivery rate of a Single Transfer Boot is 20 lbs./min. or 9 kg./min. Note: The feed delivery rate of a Twin Transfer Boot is 40 lbs./min. or 18 kg./min. (20 lbs./min. (9 kg./min.) per side. Flag Lines up to 200 feet (61 m) require using a 1/3 H.P., 1-Phase, 60 Hz, 220 V Power Unit (Part No. 3259-34). Flag lines between 200 feet (61 m) and 400 feet (122 m) require using a 1/2 H.P., 1-Phase, 60 Hz, 220 V Power Unit (Part No. 3259-39). Two 1/2 H.P. Power Units are available for 50 Hz applications. They are primarily for Flag Systems up to 400 feet (122 m). See the Power Unit Parts Listing on page 29. Refer to the Fill System Power Unit Selection Guide on page 7 (in feet) or page 8 (in meters) to determine which Power Unit is required for your individual system. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 6

Fill System Power Unit Selection Guide (in feet) 230 V, 60 Hz, Single Phase Power Units Model 75 Fill System Model 90 Fill System 348 RPM 425 RPM 348 RPM 425 RPM No. of Flag up to 81 to 151 to up to 61 to 121 to up to 31 to 91 to up to 21 to 71 to Lines 80 150 200 60 120 160 30 90 150 20 70 120 2 3259-51 3259-52 3259-49 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 - - - - - - - - - - - - 3259-77 3259-78 3259-79 - - - - - - - - - - - - - - - - - - - - - - - - 4 - - - - - - - - - - - - 3259-77 3259-78 3259-79 - - - - - - - - - - - - - - - - - - - - - - - - 5 - - - - - - - - - - - - - - - - - - - - - - - - 3259-51 3259-52 3259-49 - - - - - - - - - - - - 6 or more - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3259-77 3259-78 3259-79 230 V, 50 Hz, Single Phase Power Units Model 75 Fill System Model 90 Fill System 348 RPM 348 RPM No. of Flag up to 61 to 151 to up to 31 to 91 to Lines 60 150 200 30 90 150 2 3259-88 3259-88 3259-89 - - - - - - - - - - - - 3 3259-88 3259-88 3259-89 - - - - - - - - - - - - 4 3259-88 3259-88 3259-89 - - - - - - - - - - - - 5 - - - - - - - - - - - - 3259-87 3259-88 3259-89 6 - - - - - - - - - - - - 3259-87 3259-88 3259-89 220/380 V, 50 Hz, Three Phase Power Units Model 75 Fill System Model 90 Fill System 348 RPM 348 RPM No. of Flag up to 61 to 151 to up to 31 to 91 to Lines 60 150 200 30 90 150 2 3259-103 3259-104 3259-105 - - - - - - - - - - - - 3 3259-103 3259-104 3259-105 - - - - - - - - - - - - 4 3259-103 3259-104 3259-105 - - - - - - - - - - - - 5 - - - - - - - - - - - - 3259-103 3259-104 3259-105 6 - - - - - - - - - - - - 3259-103 3259-104 3259-105 CHORE-TIME FLAG Drop Feeding System Installation Manual Page 7

Fill System Power Unit Selection Guide (in meters) 230 V, 60 Hz, Single Phase Power Units Model 75 Fill System Model 90 Fill System 348 RPM 425 RPM 348 RPM 425 RPM No. of Flag up to 24.7 to 46 to up to 18.6 to 36.9 to up to 9.4 to 27.7 to up to 6.4 to 21.6 to Lines 24.3 m 45.7 m 61 m 18.3 m 36.6 m 48.8 m 9.1 m 27.4 m 45.7 m 6.1 m 21.3 m 36.6 m 2 3259-51 3259-52 3259-49 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 - - - - - - - - - - - - 3259-77 3259-78 3259-79 - - - - - - - - - - - - - - - - - - - - - - - - 4 - - - - - - - - - - - - 3259-77 3259-78 3259-79 - - - - - - - - - - - - - - - - - - - - - - - - 5 - - - - - - - - - - - - - - - - - - - - - - - - 3259-51 3259-52 3259-49 - - - - - - - - - - - - 6 or more - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3259-77 3259-78 3259-79 230 V, 50 Hz, Single Phase Power Units Model 75 Fill System Model 90 Fill System 348 RPM 348 RPM No. of Flag up to 18.6 to 46 to up to 9.4 to 27.7 to Lines 18.3 m 45.7 m 61 m 9.1 m 27.4 m 45.7 m 2 3259-88 3259-88 3259-89 - - - - - - - - - - - - 3 3259-88 3259-88 3259-89 - - - - - - - - - - - - 4 3259-88 3259-88 3259-89 - - - - - - - - - - - - 5 - - - - - - - - - - - - 3259-87 3259-88 3259-89 6 - - - - - - - - - - - - 3259-87 3259-88 3259-89 220/380 V, 50 Hz, Three Phase Power Units Model 75 Fill System Model 90 Fill System 348 RPM 348 RPM No. of Flag up to 18.6 to 46 to up to 9.4 to 27.7 to Lines 18.3 m 45.7 m 61 m 9.1 m 27.4 m 45.7 m 2 3259-103 3259-104 3259-105 - - - - - - - - - - - - 3 3259-103 3259-104 3259-105 - - - - - - - - - - - - 4 3259-103 3259-104 3259-105 - - - - - - - - - - - - 5 - - - - - - - - - - - - 3259-103 3259-104 3259-105 6 - - - - - - - - - - - - 3259-103 3259-104 3259-105 CHORE-TIME FLAG Drop Feeding System Installation Manual Page 8

Installation: Refer to Figures 1 through 5 for proper component installation information. 1. Install the FLEX-AUGER Fill System as specified in the Installation Manual (MA1000) supplied with the Fill System Control Unit. Install an Outlet Drop Assembly at each flag line location. Remove the Funnel from the Control Unit. Figure 1. Flag System Layout Diagram 2. An Adapter Plate (Part No. 7856) is required to connect the Fill System Control Unit to the last flag line. The Adapter Plate must be ordered separately. Secure the Adapter Plate to the Transfer Boot w/ Proximity Switch, using 1/4-20 hardware supplied. Secure the Transfer Boot/Adapter Plate assembly to the bottom of the Control Unit, using the 10-24 hardware supplied with the Control Unit. See Figure 2. Make sure the outlet end of the boot is directed toward the feeder line. Key Description 1 Adapter Plate 2 Transfer Boot 3 Proximity Boot Switch 4 Fill System Control (Model 75 or 90) 5 Outlet End of Boot 6 Flag Line CHORE-TIME FLAG Drop Feeding System Installation Manual Page 9 Figure 2. Fill System Control Unit/Terminal Boot Installation

3. Assemble a Transfer Plate to the top of each of the remaining Transfer Boots, using the 1/4-20 eye bolts supplied. See Figure 3. Key Description 1 Clean-Out Cover 2 Outlet Drop 3 Transfer Plate 4 Transfer Boot Figure 3. Transfer Boot Installation (w/o Prox. Boot Switch). 4. Suspend a Boot and Transfer Plate assembly directly below each Outlet Assembly. Make sure the outlet end of the boot is directed toward the feeder line. The bottom of the Outlet Assembly should pass through the hole in the Transfer Plate. Note: The Transfer Plate hole is sized for a Model 75 Outlet Drop. Enlarge the hole by removing the knock-out for Model 90 Outlet Drops. It may be necessary to install a Proximity Boot Switch in a Transfer Boot to prevent excessive empty auger running time. See Figure 4. Consider installing a Proximity Boot Switch in any line that would run more than 10 minutes without feed. Key Description 1 Proximity Boot Switch 2 Outlet Drop 3 Transfer Plate 4 Transfer Boot Figure 4. Transfer Boot Installation (w/ Prox. Boot Switch). 5. Install the individual feeder lines, feeders, and Control Units as specified in the specific installation manual(s). NOTE: The individual feeder lines must be suspended from the ceiling or rafters. Do not use the Fill System Auger Tubes to support the weight of the feeder line. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 10

6. Install the Delay/Relay Kit near the Fill System Power Unit. 7. For lines over 400 (122 m), a Transfer Boot (w/switch), Adapter Plate, and Control Unit are required. Install as shown in Figure 5 near the center of the line. Key Description 1 Control Unit 2 Transfer Boot 3 Adapter Plate 4 Proximity Boot Switch 5 Outgoing Feed 6 Incoming Feed Figure 5. Control Unit/Extension Boot Installation--required for systems over 400 feet (122 m). Wiring the system: The Flag System components may be configured in a variety of ways, as specified in Figures 1 and 6-9. Determine which layout diagram matches your system and refer to the appropriate wiring diagram for wiring connections. Note: 1-Phase Control Wiring diagrams for Standard and Alternate Flag Systems #1 are shown on page 14. 3-Phase Control Wiring diagrams for Standard and Alternate Flag Systems #1 are shown on page 15. System Wiring Diagrams for the Standard and Alternate Flag System #1 layouts are provided on pages 16 through 19. 1-Phase Control Wiring diagrams for Alternate Flag Systems #2, #3, & #4 are shown on page 20. 3-Phase Control Wiring diagrams for Alternate Flag Systems #2, #3, & #4 are shown on page 21. System Wiring Diagrams for the Alternate Flag Systems #2, #3, & #4 layouts are provided on pages 22 through 26. Setting the Delay: Set the 2 to 30 second delay as required to prevent the Fill System Control Unit from short cycling. Setting the delay to approximately 15 seconds is usually a good starting point. The amount of delay may need to be fine tuned to match feed type, system performance, etc. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 11

Alternate Flag System Layout Diagram #1 Figure 6. Twin Boot Flag System Layout Alternate Flag System Layout Diagram #2 CHORE-TIME FLAG Drop Feeding System Installation Manual Page 12 Figure 7. Return Flag System Layout

Alternate Flag System Layout Diagram #3 Figure 8. Circulating Flag System Layout Alternate Flag System Layout Diagram #4 CHORE-TIME FLAG Drop Feeding System Installation Manual Page 13 Figure 9. Return-to-Bin Flag System Layout

Flag System Control Options (for 1-Phase Standard and Alternate #1 Flag Systems only) CHORE-TIME FLAG Drop Feeding System Installation Manual Page 14

Flag System Control Options (for 3-Phase Standard and Alternate #1 Flag Systems only) CHORE-TIME FLAG Drop Feeding System Installation Manual Page 15

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 16 Flag System Control Options (for 1-Phase Standard Flag Systems only) Electrical Specifications: Voltage: 230 V. Hz.: 50/60 Phase: Single

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 17 Flag System Control Options (for 3-Phase Standard Flag Systems only) Electrical Specifications: Voltage: 3 X 220 V. 3 X 380 V. + N 3 X 415 V. + N Hz.: 60 Phase: Three

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 18 Flag System Control Options (for 1-Phase Alternate #1 Flag Systems only) Electrical Specifications: Voltage: 230 V. Hz.: 50/60 Phase: Single

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 19 Flag System Control Options (for 3-Phase Alternate #1 Flag Systems only) Electrical Specifications: Voltage: 3 X 220 V. 3 X 380 V. + N 3 X 415 V. + N Hz.: 60 Phase: Three

Flag System Control Options (for 1-Phase Alternate #2, #3, & #4 Flag Systems only) CHORE-TIME FLAG Drop Feeding System Installation Manual Page 20

Flag System Control Options (for 3-Phase Alternate #2, #3, & #4 Flag Systems only) CHORE-TIME FLAG Drop Feeding System Installation Manual Page 21

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 22 Flag System Control Options (for 1-Phase Alternate #2 Flag Systems only) Flag System Control Options (for 1-Phase Alternate #3 Flag Systems only)

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 23 Flag System Control Options (for 1-Phase Alternate #2 & #3 Flag Systems only) Electrical Specifications: Voltage: 230 V. Hz.: 50/60 Phase: Single

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 24 Flag System Control Options (for 3-Phase Alternate #2 & #3 Flag Systems only) Electrical Specifications: Voltage: 3 X 220 V 3 X 380 V + N 3 X 415 + N Hz.: 60 Phase: Three

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 25 Flag System Control Options (for 1-Phase Alternate #4 Flag Systems only) Electrical Specifications: Voltage: 230 V Hz.: 50/60 Phase: Single

CHORE-TIME FLAG Drop Feeding System Installation Manual Page 26 Flag System Control Options (for 3-Phase Alternate #4 Flag Systems only) Electrical Specifications: Voltage: 3 X 220 V 3 X 380 V + N 3 X 415 V + N Hz.: 60 Phase: Three

Transfer Boot Assembly Single Part No.: 35727 Twin Part No.: 35942 Key Description Part No. 1 Transfer Cover 29872 2 Clean-Out Cover 6301 3 5/16-18 Wing Nut 2146 4 Sealing Washer 8491 5 1/4-20 Eyebolt 1928 6 Back Plate Assembly 6298 7* 1/4-20 x 2 Socket Hd C.S. 5083-4 8* Drive Tube 30932 9* Driver Block 4642 10 5 Stub Tube 8555 11 2 Clamp 29520 12 Cap 29523 13 Stub Tube 4163 14** Set Collar 1386 15** Anchor Bearing 39407 16** Socket Screw 6850-6 17** Auger Clamp 39205 18** Flag Anchor 39414 Key Description Part No. 19 Model 55 Tube Clamp 35726 20 Boot Body Weldment (Single)35646 21 Boot Body Weldment (Twin) 35936 22 Twin Flag Baffle 35941 23*** Adapter Plate 7856 24 Single Flag Boot Baffle 35646 -- Danger Decal 2527-9 *These items may be ordered as an assembly under CHORE-TIME Part No. 30931. **These items may be ordered as an assembly under CHORE-TIME Part No. 39408. ***The Adapter Plate is not included with the Transfer Boot Assemblies. It must be ordered separately. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 27

3259-0 Fill System Power Units for Flag Systems 3259-49 3259-51 3259-52 3259-77 3259-78 3259-79 3259-88 Item Description Part No. Part No. Part No. Part No. Part No. Part No. Part No. 1 Motor 6857 5050 5051 5050 5051 6857 6305 2 90 Degree Connector 4228 4228 4228 4228 4228 4228 4228 3 Anti-Short Bushing 6304 6304 6304 6304 6304 6304 6304 4 Pipe Plug 2755 2755 2755 2755 2755 2755 2755 5 Gearhead 3261-7 3261-7 3261-7 3261-10 3261-10 3261-6 3261-10 6 Vent Plug 3523 3523 3523 3523 3523 3523 3523 7 S Hook 4270 4270 4270 4270 4270 4270 4270 8 Pinion Assembly 6104 5046 5046 5046 5046 3249 5046 9 Magnetic Pipe Plug 30160 30160 30160 30160 30160 30160 30160 3259-89 3259-103 3259-104 3259-105 Item Description Part No. Part No. Part No. Part No. 1 Motor 26157 28035 28034 28035 2 90 Degree Connector 4228 4228 4228 4228 3 Anti-Short Bushing 6304 6304 6304 6304 4 Pipe Plug 2755 2755 2755 2755 5 Gearhead 3261-10 3261-10 3261-10 3261-10 6 Vent Plug 3523 3523 3523 3523 7 S Hook 4270 4270 4270 4270 8 Pinion Assembly 6104 5046 5046 6104 9 Magnetic Pipe Plug 30160 30160 30160 30160 Power Unit Assembly Part Numbers: Part Number HP RPM Phase Hz Voltage 3259-49 1 HP 348 RPM Single Phase 60 Hz 230 3259-51 1/2 HP 348 RPM Single Phase 60 Hz 230 3259-52 3/4 HP 348 RPM Single Phase 60 Hz 230 3259-77 1/2 HP 425 RPM Single Phase 60 Hz 230 3259-78 3/4 HP 425 RPM Single Phase 60 Hz 230 3259-79 1 HP 425 RPM Single Phase 60 Hz 230 3259-88 3/4 HP 348 RPM Single Phase 50 Hz 220 3259-89 1 HP 348 RPM Single Phase 50 Hz 220 3259-103 1/2 HP 348 RPM Three Phase 50 Hz 220/380-415 3259-104 3/4 HP 348 RPM Three Phase 50 Hz 220/380-415 3259-105 1 HP 348 RPM Three Phase 50 Hz 220/380-415 CHORE-TIME FLAG Drop Feeding System Installation Manual Page 28

3259-0 Flag Line Power Units 3259-34 3259-39 3259-98 3259-100 Item Description Part No. Part No. Part No. Part No. 1 Motor 4229 5703 5977 28031 2 90 Degree Connector 4228 4228 4228 4228 3 Anti-Short Bushing 6304 6304 6304 6304 4 Pipe Plug 2755 2755 2755 2755 5 Gearhead 3261-5 3261-5 3261-11 3261-11 6 Vent Plug 3523 3523 3523 3523 7 S Hook 4270 4270 4270 4270 8 Pinion Assembly 5046 5046 5046 5046 9 Magnetic Pipe Plug 30160 30160 30160 30160 Power Unit Assembly Part Numbers: Part Number HP RPM Phase Hz Voltage 3259-34 1/3 HP 348 RPM Single Phase 60 Hz 230 3259-39 1/2 HP 348 RPM Single Phase 60 Hz 230 3259-98 1/2 HP 348 RPM Single Phase 50 Hz 220 3259-100 1/2 HP 348 RPM Three Phase 50 Hz 220/380-415 CHORE-TIME FLAG Drop Feeding System Installation Manual Page 29

Proximity Boot Switch Assembly Part No.: 34779 Item Description Part No. 1 Retainer Bracket 30942 2 Box Plate 24321 3 Window Plate 7842 4 Switch Cover Plate 30941 5 Adjustable Clamp 3527 6 Proximity Plate Weldment 34758 7 Sealing Washer 8491 8 5/16-18 Wing Nut 2146 9 230 V. Relay 34654 10 Switch Box Gasket 6777 11 Switch Box Cover 6776 12 1/2" Liquid Tight Connector 23779 13 Switch Box 24702 14 Proximity Switch 34255 Delay Relay Kit Part No. 30953 Key Description Part No. 1 Switch Box Cover 6776 2 Decal 2529-400 3 Gasket 6777 4 Switch Box 33814 5 1/2" Liquid Tight Connector 23779 6 ON Delay Timer 24411 7 Relay 24335 8 Box Plate 24321 Miscellaneous Components Key Description Part No. 1 10 PVC Tube 7955 2* Auger 25058F-0 -- Extension Boot Control Unit 6500-8 *Auger may be ordered in lengths from 50 ft. (15.2 m) to 400 ft. (122 m). Example: 25058F-150 would represent 150 ft. (45.7 m) of 25058F Auger. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 30

This Page Intentionally Left Blank. CHORE-TIME FLAG Drop Feeding System Installation Manual Page 31

THANK-YOU for purchasing a Chore-Time Flag Delivery System. Made to work. Built to last. Revisions to this Manual Page No Description of Change 6 Added 216 RPM information 16-26 Corrected graphics 27 Bearing and Anchor Assembly Part No. 30933 replaced with Part No. 39408 Contact your nearby Chore-Time distributor or representative for additional parts and information. Chore-Time Equipment, A Division of CTB, Inc. P.O. Box 2000, Milford, Indiana 46542-2000 U.S.A. Phone: 219-658-4101 E-Mail: ctb@ctbinc.com Printed in the U.S.A.