Automated Connector Processing Tackles Exploding FTTP Connector Market

Similar documents
Innovations in PON Cost Reduction

Symmetrical Services Over HFC Networks. White Paper

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO (BBOX) BLACKBOX.COM/PRETERMFIBER

Electric Co-op Solutions Guide

WDM Video Overlays on EFM Access Networks

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

3M No Polish Jacketed SC/APC Connector

OptiTect Premier Local Convergence Cabinet An Evolant Solutions Product

Upgrade of 450/550 MHz Cable Systems to 600 MHz Using a Phase Area Approach. Robb Balsdon Vice President, Engineering Services Rogers Engineering

Illinois Telephone Users Group. Peoria, IL June 6, 2007

Review of the Comcast. Fort Collins Cable System. Technical Characteristics

3M No Polish Jacketed SC/APC Connector

Verizon New England Inc. Application for a Compliance Order Certificate for Rhode Island Service Areas 1 and 4. Exhibit 3

HFC CABLE SYSTEM REVIEW

3A+G Technology & Turnkey Production Solution XFS COMMUNICATIONS, INC.

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product

Re: Implementation of Section 304 of the Telecommunications Act of 1996, Commercial Availability of Navigation Devices, CS Docket 97-80

Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned

LTX Optical Distribution Panels. Ordering Guide

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC

Model DM8000-U Optical Transmitter Direct Modulation, DWDM, Low Distortion, Wideband

Optical Fiber in the Local Loop: Approaches to the Triple Play Richard Mack page 226

Development of optical transmission module for access networks

TriAccessTM. Solutions for Advanced CATV & High-Speed Data

Prisma D-PON System ONT and Upstream Receiver

Opti Max Nodes Digital Return System

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

Ver. 1.0sb 1550nm Erbium Doped Fiber Amplifier MX-A5100 Series Technical Specification

TriAccess Solutions. Advanced CATV & High-Speed Data

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

Emerging Subsea Networks

ULTRA HIGH DENSITY SOLUTION GUIDE

Impacts on Cable HFC Networks

EDFA Erbium Doped Fibre Amplifier

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Enabling home networking for digital entertainment TM. IEEE Presentation. March 2005

Hands-On Real Time HD and 3D IPTV Encoding and Distribution over RF and Optical Fiber

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

OPTICAL FIBERCONNECT. Version 3.

ED5229GT-E Series. Page 1 of 8

CHP Max Headend Optics Platform CHP CORWave II

OPTICAL DISTRIBUTION STATION -

Course Title: SE 4C03 Winter Title of Project: Cable Modems. Name of researcher: Mohammed Kadoura

Chapter 2. Analysis of ICT Industrial Trends in the IoT Era. Part 1

Overcoming Nonlinear Optical Impairments Due to High- Source Laser and Launch Powers

Lensed Fibers & Tapered Ends Description:

QFN. QFN Fiber Node INSTALLATION & OPERATION MANUAL.

OpticalProducts. Illuminating Your Network. Testing the World s Networks

CABLE S FIBER OUTLOOK SURVEY REPORT

Prisma II Optical Amplifiers for Fiber to the Home (FTTH)

APPENDIX D TECHNOLOGY. This Appendix describes the technologies included in the assessment

Fiber drop cable solutions. Flexible solutions for the evolving networks of tomorrow

Fiber Optics Redefined

GPON installation in high rise buildings via Fiber Tree system

DOCSIS 3.1 Development and its Influence on Business

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4

SECTION 4 TABLE OF CONTENTS

FORWARD PATH TRANSMITTERS

Model GS Port Node 1 GHz with 65/86 MHz split

Prisma Optical Networks Ancillary Modules

DROP HARDENING. January 21, 2015

InterReach Fusion Data Sheet

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

FIBER OPTIC POSITRONIC INDUSTRIES. Interconnection Systems. RoHS Compliant Options Available! Catalog A-011 Rev.

CABLE TV on fiber. CABLE TV FIBERLINK Pass 100+ TV channels on 1 SingleMode fiber with no need for amps

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Follow The Leader In Shielded Technology

General Questions. Q: What s the big deal about fiber? Why is it better than what I have today? Q: How is the fiber going to be installed to my home?

Agilent 81600B Tunable Laser Source Family

Cost Effective High Split Ratios for EPON. Hal Roberts, Mike Rude, Jeff Solum July, 2001

Crossing the. Diplex Chasm. to 85 MHz. Author: Todd Gingrass Cable & Media Solutions

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

Fusion SOC Deployment for Reliable FTTH Network. Mehabub Ali Mondal & W S Choi Ilsintech Trading India Pvt Ltd 13 th April 2017

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description

WHITE PAPER. Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

fibre optic r solutions multiple dwelling Bringing units In just One Pass 3M One Pass Fibre Pathway One Floor of fibre with One Crew in One Pass

Market- versus Technology-Driven R&D in Optical Communications Industry. Winston I. Way, April 23, 2008

SC Connector. Fiber Optic Connectors. MDR Electronics

Understanding IPTV "The Players - The Technology - The Industry - The Trends - The Future"

Optical Component Environmental Test System

Fiber to the Home. the New Empowerment. Paul E. Green, Jr May 19, Ref.: Book of same title, John Wiley and Sons, 2005

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

MPS Webinar Technical Series

Agilent 87075C Multiport Test Set Product Overview

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

FOGGY DOCSIS AN ENABLENCE ARTICLE WRITTEN BY JIM FARMER, CTO APRIL,

Connectix Cabling Systems

Proposal of Distributing 4 SAT IF Signals To 209 Homes within 3Km Over Fiber Cable

Transcription:

Automated Connector Processing Tackles Exploding FTTP Connector Market By Joyce Kilmer and Duane Dinkel Sagitta Inc 7 Oser Avenue Hauppauge, NY 11788 Tel: 631 952 9440 Fax: 631 952-9144 www.sagitta.com Abstract With Verizon, SBC, and BellSouth s initiative to use Fiber to the Premises (FTTP) as a means to leapfrog the limited consumer bandwidth provided by DSL and Cable Modems and Verizon s recent awarding of FTTP contracts to its key suppliers, fiber optic connector usage is predicted to soar. Automation of the key pinch points of connector termination process, where most of the yield fallout occurs in a manual production, is imperative in order to reach the aggressive FTTP cost and quality targets. Integration of the polishing, cleaning, and inspection processes is shown to be an effective solution for high volume batch processing of the APC connectors as required by the burgeoning FTTP build outs. Intro Verizon has committed to deploying FTTP services (i.e. The Triple Play) to 1 million homes in the US this year, 2 million in 05, and over 4 million in 06, at which point SBC has indicated it will also begin its initial FTTP rollout. The Passive Optical Network (PON) architecture selected by these local carriers is based upon preconnectorized fiber optic splitters and drop cables which are to be deployed in the Outside Plant (OSP).

Preconnectorized cables and modules have been selected such that service can be incrementally deployed to subscribing customers in a simple plug and play fashion by lower skilled craft personnel. The initial part of the project now underway is to build out the feeder and distribution portion of the network so that a majority of the homes in a target area are passed by and then can be easily connected when an individual subscriber opts to take the high bandwidth services offered by the local carrier. The architecture of the network is based upon fiber optic feeder cables (typically 12, 24 or 48 fiber count) that are fusion spliced to preconnectorized splitter modules within the Service Area Interconnect (SAI) or Fiber Distribution Hub (See Figure 1). Also, within the SAI are preconnectorized distribution cables (often as high as 432 fiber count!) that are fusion spliced to the distribution side of the network. Higher skilled construction crews do all of this initial fusion splicing, but are not need to subsequently connect individual subscribers. Premises Feeder Cable Distribution Cable SAI Fiber Drop Drop Terminal ONT x 1 x 32 splitter x x x Fusion Splice APC Connector End Figure 1 - APC Connectors in FTTP OSP Once a customer subscribes to the service, a craftsperson connects one of the preconnectorized splitter output ports to the corresponding preconnectorized distribution cable port in the SAI and installs an ONT at the customer premises. The craftsperson then utilizes a laser range finder to determine the distance from the drop terminal to the ONT in order to select the correct length of preconnectorized drop cable (typically ranging

from 50 to 250 ft) in order to complete the final connection from the drop terminal to the subscriber s ONT. For a centralized PON based architecture utilizing preconnectorized splitters in the SAI and preconnectorized drops to the ONT, we see 6 APC connector ends are located in 3 different OSP cabinets as follows: SAI Fiber Distribution Hub where Splitter is located: Connector on Splitter scales with homes subscribing Connector on preconnectorized Distribution Cable scales with homes passed Drop Terminal Fiber Terminal where preconnectorized Fiber Drop Cable is dropped to the ONT on the side of the house: Connector on preconnectorized Distribution Cable scales with homes passed Connector on preconnectorized Drop Cable scales with homes subscribing ONT: Connector on preconnectorized Drop Cable scales with homes subscribing Connector end that is inside the ONT is typically a fiber stub within a receptacle based TROSA scales with homes subscribing Thus, we see 2 connector ends are required for each home passed and another 4 connector ends are required when a home subscribes for service. APC Connectors Fiber optic connectors are typically deployed within inside plant (ISP) environments, i.e., within Central Offices (COs) or within Controlled Environment Vaults (CEVs). The only fiber optic connector type that has been field proven in an OSP environment is the angled physical contact (APC) connector. CATV companies have been successfully using APC connectors in the OSP for over fifteen years. However, for CATV companies, APC connector usage is typically limited because: CATV fiber spans are typically thin (i.e., use low fiber count cables) CATV only uses connectors for the node service cables interfacing with active electronics in the OSP CATV applications typically prefer to fusion splice their plant to minimize the back reflection that can degrade their analog signaling Carrier to Noise Ratio (CNR). However, there is an advantage to having the active amplifiers that are deployed in their Hybrid Fiber Coax (HFC) networks to be connectorized because maintenance can be eased. The only connector that meets their Return Loss requirements for their analog signaling (i.e., 65dB) is APC connectors. Since Verizon desires to have their FTTP build outs capable of handling multiple transmission protocols, they too have chosen to utilize APC connectors. The additional

benefit of utilizing APC connectors in PON architecture is that you can avoid the use of terminators on the unused splitter ports. Unused splitter ports with standard flat polished UPC connectors must be terminated to avoid the large air/glass reflectance (~14.5dB) that can disrupt the upstream lasers in the OLTs. Fiber optic terminators are a simple device that act as an optical sink minimizing back reflection; but, are yet another optical component that the carrier must inventory. Standardizing on APC connectors eliminates the need to terminate the used ports as unterminated APC connectors have ~65dB Return Loss from their angle polished air/glass interfaces. Verizon s decision to utilize APC connectors is the first true mass deployment of this connector type. While connector suppliers had ramped up capacity for other fiber optic connector types during the Telecom Bubble, the APC connector business remained somewhat of a lower volume niche market. Based on the projection of homes passed and subscribed by Verizon and the number of APC end per subscriber seen in Figure 1, combined with the additional connectors that will be required within the Fiber Distribution frames (FDFs) and OLTs to terminate the feeder cables in the CO we find explosive APC growth is anticipated (see Figure 2). US FTTP Projections (APC Ends) Connector Ends (000) 35,000 30,000 25,000 20,000 15,000 10,000 5,000 0 31,200 16,400 8,400 240 4,000 2003 2004 2005 2006 2007 Figure 2: FTTP Connector Growth Automation to the Rescue Fiber optic connector manufactures had built up an inventory of fiber optic connector terminating and polishing equipment during the Telecom Bubble. The ability to attain new or slightly used equipment on the grey market combined with the movement of production to low labor cost countries overseas gave little incentive to connectivity manufactures to invest in new capital equipment. However the bulk of that equipment was for polishing and terminating 2.5mm (SC) or 1.25mm (LC) ferrule based connectors

with flat UPC polished ends. APC connectors never had such huge volumes, even during the Telecom Bubble, for manufactures to explore high volume production capabilities for these connectors. APC connectors are inherently more difficult to produce than UPC connectors. Angle tolerances (typically 8+/-0.2 º) must be accurately controlled in addition to the standard geometrical parameters of: apex offset, radius of curvature, and fiber height. To make APC connectors today, manufactures typically must use standard bench top polishers and are limited to 12 port polishing jigs in order to produce quality product. The most practical way to increase connector production capacity is to increase the number of parts you polish at one time. However, maintaining the strict geometric tolerance required for APC connectors while increasing your batch size is challenging. Consequently, even moving to an 18 port jig for APC connectors on a manual polisher is precarious. By employing novel adaptive process controls on our polishing head, Sagitta has created standard processes for both the extended chamfer (aka cone or pencil tipped ) as well as step based APC ferrules [1] for batch polishing 48 APC connectors at a time enabling throughputs in excess of 200 APC ends per hour. Highly efficient use of the films coupled with optimal process recipes ensure low cost of consumables. Furthermore, automated inspection algorithms eliminate the operator subjectivity involved in the manual visual inspection of polished connector end faces. Typical geometrical results attained with Sagitta s Gemini-Cx vs. industry standards for APC connector are shown below: Angle ( ) Apex Offset (µm) ROC (mm) Industry Standards 7.8 8.2 < 50 5-12 Typical Gemini Results 8 +/- 0.07 22 +/- 10 7 +/- 0.8 Table 1: Typical Results vs. Industry Standards Guaranteed yield improvements and consumable cost savings combined with labor savings make this type of automation a compelling value proposition even in low labor cost countries. But more importantly, it may enable a US manufacturer to maintain domestic production, close to their FTTP customer. Unit cost comparisons between a typical US manufacturer employing manual processes and Gemini automation is summarized below:

US Gemini (in US) Cost Component Qty Scrap U/C Cost Qty Scrap U/C Cost BOM SC/APC Housing Parts 1 3% $1.10 $1.10 1 2% $1.10 $1.10 Ferrule 1 3% $0.80 $0.80 1 2% $0.80 $0.80 Boot 1 2% $0.25 $0.25 1 1% $0.25 $0.25 SM Fiber (2m) 2 2% $0.04 $0.08 2 2% $0.04 $0.08 Consumables 1 3% $0.32 $0.32 1 2% $0.15 $0.15 Packaging 1 1% $0.09 $0.09 1 1% $0.09 $0.09 Total Material Cost $2.64 $2.47 DL & Overhead Direct Labor 0.17 $11.80 $1.97 0.02 $12.00 $0.18 Overhead fixed and variable 0.60 $1.18 0.60 $0.11 Depreciation (5 yr, SL) $0.06 $0.13 Scrap Costs 2.8% $0.16 1.9% $0.05 Misc. (Freight, etc.) $0.08 $0.08 Total DL & Overhead Cost $3.45 $0.55 Total MFG COGS $6.09 $3.02 Table 2: Unit Cost Comparisons Automation of the polishing, cleaning, and inspection processes of fiber optic connector manufacturing is imperative in order to reach the aggressive FTTP cost and quality targets. Sagitta s Gemini-Cx is an effective solution for high volume batch processing of the APC connectors now being required by the burgeoning FTTP build outs. References: [1] Contreras et al, Method of Achieving Excellent APC Connector End Face Parameters Using Chamfered Ferrules, IEEE Electronic Components and Technology Conference, p. 535, 1999.