The parameters can be changed according to the needs of the operator. Do not change the settings of the Maintenance screen.

Similar documents
KRAMER ELECTRONICS LTD. USER MANUAL

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

Model: AV D Keyboard Controller. User Manual. Please Read this User Manual throughout before using.

INSTALATION PROCEDURE

Intelligent Security and Fire Ltd

SNG-2150C User s Guide

Quick Guide Book of Sending and receiving card

T2210HD/T2210HDA 21.5 Wide-Screen LCD Monitor User Manual

SAT IF distribution system

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

9 Analyzing Digital Sources and Cables

Usermanual. P2K-HL3E1 1080p HDMI Extender over IP P2K-HL3E1-P 1080p HDMI Extender over IP with PoE P2K-HRSL3E1 / P2K-LHRS1E3

SXGA096 DESIGN REFERENCE BOARD

RF Solution for LED Display Screen

PC/HDTV to PC/HDTV converter (CP-251F)

RMS 8424S Quick Start

DiD. LCD Video Monitor & Video Wall Universal User Manual. Digital Information Display

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

CCE900-IP-TR. User s Guide

VSP 198CVS Quick Start

Xi an NovaStar Tech Co., Ltd. User's Manual. LED Video Controller VX4S/VX4. Rev1.1.2 NS

G3 NET 2K USER MANUAL

CNC872 Series CNC System Application for Cutting Machines

KRAMER ELECTRONICS LTD. USER GUIDE MODEL: VP-790 Blending Projected Images on a Curved Screen. P/N: Rev 1

12.1 Inch CGA EGA VGA SVGA LCD Panel - ID #492

VIDEO GRABBER. DisplayPort. User Manual

EEG A1452 SCTE-104 Inserter Frame Card

F7000NV ROBOT VISION OPERATING MANUAL

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

P-2 Installing the monitor (continued) Carry out as necessary

DP Tuner 80 Remote Control Software User Manual. Version:08 Issue Date:May 10, 2018

Projector Management Application Version 7.00 Instruction Guide

2D/3D Multi-Projector Stacking Processor. User Manual AF5D-21

VS-TV. User manual. Virtual Matrix ENGLISH

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

VGA to Video Converter ID# 424 Operation Manual

Owners SW-LCD 2.0 Manual & Specifications

PYROPTIX TM IMAGE PROCESSING SOFTWARE

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5

Single cable multiswich programmer PC102W

VBOX 3i Dual Antenna Measures Slip and Pitch/Roll (RLVB3iSL)

Part names (continued) Remote control

Show Designer 3. Software Revision 1.15

Precautions and Disclaimers What You Can Do with Geometry Manager Pro Check Your Computer System requirements...

15 Inch CGA EGA VGA to XGA LCD Wide Viewing Angle Panel ID# 833

26 Inch CGA/EGA/VGA/DVI to WXGA/1080p LCD - ID#703

1. Update Software in Meter

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

DVI-3580a. 4K MultiViewer Switcher / Scaler. Quick Start Guide. Introduction

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

Video Server SED-2100R/S. Quick Installation Guide

GS122-2L. About the speakers:

VBOX3i Dual Antenna. Measures Slip and Pitch/Roll (RLVB3iSL) Features

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

V9A01 Solution Specification V0.1

LedSync820C LED Video Processor USER S MANUAL

Video wall Precautions when moving and handling. Precaution. Please adhere to the warning signs printed on the box.

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

LedSet User s Manual V Official website: 1 /

VGA AUDIO SWITCHER S MANUAL

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

CGA to EGA to VGA Converter (Multi) ID#425

Rear Panel / Side Panel Jacks (LN26A450C1D, LN40A450C1D)

ASF 2050 COMBO USER MANUAL

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Broadcast A/V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

QuickSpecs. HP VH27 27-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. Exit

Broadcast A / V Division M-LYNX-702 V.3. Dual 7 LCD Display. User Manual

IMPORTANT SAFETY INSTRUCTIONS

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

22" Touchscreen LED Monitor USER'S GUIDE

Extra long-range RFID (proximity) card reader

Syntor X Flash Memory Module Revision C

ASSEMBLY AND CALIBRATION

VISION. Data VS2 DATAVS2. Phone: Fax: Web:

IMPORTANT SAFETY INSTRUCTIONS Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions

SHOWLINE SL NITRO 510C LED STROBE LUMINAIRE SPECIFICATIONS.

Statement Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as Novastar ). It is our great pleasure to offer this

Bang & Olufsen presentation Technical overview BtB

Table of Contents TABLE OF CONTENTS. Vivid Drive 23N User Manual Rev. 1

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

USB-0100TX USB Fast Ethernet Converter. User s Guide

PART 1 PRODUCT (GENERAL)...1.

VBOX 3i. 100Hz GPS Data Logger (VB3i-V3) Features

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

REMOTELY CONTROL SCANDO HD

MINI HIGH SPEED DOME CAMERA. User Manual

ivw-ud322 / ivw-ud322f

GI V E YOUR TA LENT THE TOOL S IT DESERV ES.

Statement Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as Novastar ). It is our great pleasure to offer this

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Safety Precautions and Maintenance

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

Rear Panel / Side Panel Jacks

CrossLine Generator Operation Manual

HITACHI. Instruction Manual VL-21A

User Guide

Operating Instructions

Transcription:

2.13 Parameter Settings The parameters can be changed according to the needs of the operator. 1 Display the Setting screen. 1) Press the MENU button on the layout screen. The pop-up menu is displayed. 2) Press the Setting button. The Setting screen is displayed. 2 2 Select the screen that includes the desired parameters. Select from among [System Setting] to [Communication]. See page 84 for parameters on each screen. The System Setting screen has three pages. Pressing the >> or << button switches the page. Do not change the settings of the Maintenance screen. If the settings are changed, they may not work properly. 3 Press the desired parameter item to be changed. The selected parameter item will turn green. The numeric keypad or pop-up menu will appear. 4 Change the setting. Numeric keypad Enter a new value. Pop-up menu Select a new setting from the menu. 5 Return to the Menu screen. Press the EXIT button. 6 Return to the layout screen. Press the EXIT button. 83

Parameter items and setting contents <System Setting 1 screen> 1 : Language: ENGLISH, JAPANESE Factory setting: ENGLISH Selects the language to be displayed. 2 : PTN Memory: INTERNAL, EXTERNAL Factory setting: INTERNAL Selects whether registered shape data is saved in the LT-1000 (INTERNAL) or external devices such as RD-100 (EXTERNAL). 3 : JOB# Input Interface: TENKEY, KEYPAD Selects the numeric keypad or keyboard to enter a JOB#. Select KEYPAD (keyboard) to enter alphabet characters. 4 : PTN# Input Interface: TENKEY, KEYPAD Selects the numeric keypad or keyboard to enter a PTN#. Select KEYPAD (keyboard) to enter alphabet characters. 5 : Trace Start on Scanning Barcode: ON, OFF When the setting is ON, starting the barcode scanning starts tracing automatically. Both-eye tracing is performed for frames and right pattern tracing is performed for patterns. 6 : Trace Data Auto Set: ON, OFF When the setting is OFF, pressing the DATA SET button calls up the trace result. When the setting is ON, starting the trace grays out all buttons on the layout screen. The trace result is automatically displayed on the screen after tracing. When tracing is performed on any screen other than layout, pressing the DATA SET button calls up the trace result. 7 : VCA Data Display: Rx, A, B Factory setting: Rx When the setting is A,B, the values of A, B, and ED appear instead of PD,, Axis. A: Horizontal length of the shape B: Vertical length of the shape ED: Double the distance between the boxing center and furthest edge Size D: Size adjustment value (diameter), units: mm Size C: Size adjustment value (circumference), units: mm This setting is available only when the Communication Interface parameter on the Communication screen is set to VCA-A, VCA-B, or VCA- C. 84

8 : VCA Layout Screen: NORMAL, SIMPLE Factory setting: NORMAL When the setting is SIMPLE, the input fields other than FPD, Size, JOB#, and frame type disappear. This setting is available only when the VCA Data Display parameter is A,B. 9 : VCA Trace Data Auto Transfer: ON, OFF When the setting is ON, the traced data is automatically transferred to the server after tracing. This setting is available only when the VCA Data Display parameter is A,B. 2 10 : VCA JOB# Input: ON, OFF When the setting is OFF, the JOB# input field disappears. This setting is available only when the VCA Data Display parameter is A,B. 11 : VCA Trace Data Type: Single, Both Factory setting: Both Sets whether to use the data mirrored from the right-eye lens shape or actual traced data as the trace data for the left-eye lens in both-eye tracing. Single: The traced data for the left-eye lens is regarded as the data mirrored from the right-eye lens shape. Both: The actual traced data is used. This setting is available only when the Communication Interface parameter on the Communication screen is set to VCA-A, VCA-B, or VCA-C. <System Setting 2 screen> 1 : Layout Preset:. Sets the default optical center height ( ). 2 : Set Layout Both Eyes: ON, OFF Selects whether or not the optical center height is entered individually for the right and left eye sides. When the setting is ON, entering the optical center height of either eye side enters the same value in the other eye side. 3 : Polish/S.B. Setting: LE, SE/ME Factory setting: SE/ME Selects the edger to be connected. Select LE for the LE-9000 series and SE/ME for the ME-1000 or SE-9090 Express. The selectable options for polishing and safety beveling depend on the selected edger. 85

4 : Soft Mode Switch: ON, OFF Sets the Soft button, which turns soft processing mode on or off, to be displayed on the layout screen or not. 5 : Active Setting of Multi Focal: ON, OFF Selects whether or not the layout mode can be changed to Active for bifocal lenses. When the setting is OFF, the passive mode is automatically selected. 6 : Rx. All Input: ON, OFF Sets so that JOB data cannot be sent if necessary layout data and prescription are not entered. When the setting is ON, the fields that needs to be entered are displayed in yellow after specifying frames (or after loading trace data). The field color changes to gray when the field is entered. Pressing the Send button while any fields remain yellow displays a message informing that necessary item fields remain. 7 : Frame Curve Input (Single-eye Tracing): ON, OFF Sets whether or not to edit the frame curve value in single-eye tracing. When the setting is ON, pressing the Change button after single-eye tracing allows the frame curve value to be edited. However, the frame curve value cannot be edited unless the FPD or DBL value has been already entered when the Rx All Input parameter is set to ON. 8 : Frame Angle Input (Single-eye Tracing): ON, OFF Sets whether or not to edit the frame tilt angle in single-eye tracing. When the setting is ON, pressing the Change button after single-eye tracing allows the frame tilt angle to be edited. However, the frame tilt angle cannot be edited unless the FPD or DBL value has been already entered when the Rx All Input parameter is set to ON. 9 : Hi-curve Frame Trace Function: ON, OFF Sets whether or not to display the Hi-curve button on the Layout screen for high base curve frame tracing. Only when the setting is ON and the frame type is Metal or Plastic, Hi-curve button is displayed. It is possible to be set to ON in the following cases: The Communication Interface parameter is set to LAN. The Communication Interface parameter is set to VCA-A, VCA-B, or VCA-C, and the VCA Trace Data Type parameter is set to Both. 10 : Hi-curve Frame Setting Function: ON, OFF Sets whether or not to display the Hi-curve button on the Layout screen for high base curve processing setting. Only when the setting is ON, the frame type is Metal or Plastic, and the layout mode is Passive, High base curve processing setting is possible. It is not possible to be set to ON when the Communication Interface parameter is set to STD. 86

11 : VCA-B DBL Value: Normal, Actual Factory setting: Normal Selects calculation method of the DBL value displayed after both-eye tracing. Normal: DBL=FPD-(right lens width + left lens width) The calculated value may be smaller than the actual DBL of the frame. Actual: Actual measured value is displayed. This setting is available only when the Communication Interface parameter on the Communication screen is set to VCA-B. <System Setting 3 screen> 2 1 : Groove Setting Function: ON, OFF Selects whether or not the Groove button is displayed on the layout screen for nylor frames. 2 : Default Groove Setting: ON, OFF Selects whether grooving is on or off as default for nylor frames. When the Groove Setting Function parameter is set to OFF, this setting is not available. 3 : Default Groove Position:. Sets the default groove position (unit: mm). 4 : Default Groove Depth:. Sets the default groove depth (unit: mm). 5 : Default Groove Width:. Sets the default groove width (unit: mm). 6 : JOB/PTN Data Clear: ON, OFF When the setting is ON, entering the JOB No. or PTN No. automatically clears the lens shape and each prescription returns to the default values. 7 : Patient s View: ON, OFF When the setting is ON, the display of the lens shape and each prescription on the Layout screen is inversed. 8 : Show ED (Effective Diameter): ON, OFF When the setting is ON, the ED value (minimum lens diameter necessary for processing) is displayed on the Layout screen. The ED value is a reference value. Layout screen when the Patient s View parameter is set to ON. 87

<Communication screen> 1 : Communication Interface: LAN, VCA-A, VCA-B, STD Selects a communication format. LAN: LAN format VCA-A: VCA format (preset initialize). Use the sent circumference without being processed in the VCA (OMA) communication. VCA-B: VCA format (preset initialize). Recalculate the 3-D circumference from the frame curve in the VCA (OMA) communication. VCA-C:VCA format (preset initialize). Process based on the sent 3-D circumference in the VCA (OMA) communication. *3 STD: Nidek standard format. Select this option when the LT-1000 is connected only to a PC. Set LAN when using the LAN connector for communication and VCA-A, VCA-B, VCA-C, or STD when using the RS-232C connector. In the VCA-A, VCA-B, or VCA-C setting, the following functions are not available. Lens material: Acrylic, Urethane Guided processing Lens type: Others 2 : CLIENT/HOST: CLIENT, HOST Selects whether the LT-1000 is host or client in the network. 3 : Communication Port: ETHERNET, RS-232C Selects whether the LAN or RS-232C connector is used for LAN access. ETHERNET is automatically selected when the Communication Interface parameter is set to LAN and RS-232C is selected when the parameter is set to VCA-A, VCA-B, VCA-C, or STD. 4 : RS-232C Baudrate: 38400, 9600 Factory setting: 38400 Sets the communication speed (baud rate) for data communication using the RS-232C connector. 5 : RS-232C Hardware Flow Control: ON, OFF Sets RS-232C hardware flow control on or off. *3. To set to VCA-C, use the internal tracer unit with corresponding version software. Contact NIDEK or your authorized distributor for upgrading the tracer unit. 88

6 : STD/VCA LT-900 Compatible Mode: ON, OFF When the setting is ON, the STD/VCA communication is available in the format compatible with the LT-900. 7 : VCA Output A, B, and ED: ON, OFF When the setting is ON, the upload data to the VCA host includes each value of A, B, and ED. The labels are as follows: A: HBOX B: VBOX ED: MBD Layout screen when the STD LT-900 Compatible Mode is set to ON 2 8 : VCA Number of Radii: 500, 512, 800, 1000 Factory setting: 500 Sets the number of shape points to be presented first to the VCA host during the initialization session in the VCA communication. 9 : VCA-B Circumference Offset for Frame:. Sets the value to be added to the circumference when tracing a frame in the VCA-B setting. Unit: mm The shape will be changed so that the circumference value becomes the set circumference value plus this offset value. Thus, the actual value may be different from the setting value. 10 : VCA-B Circumference Offset for Pattern:. Sets the value to be added to the circumference when tracing a pattern in the VCA-B setting. Unit: mm The shape will be changed so that the circumference value becomes the set circumference value plus this offset value. Thus, the actual value may be different from the setting value. 11 : VCA Output Z Data: ON, OFF When the setting is ON, the upload data to the VCA host includes Z data. *4 This setting is available only when the Communication Interface parameter is set to VCA-A or VCA-B. The setting is always ON for VCA-C. 12 : VCA Output Groove Position by BEVP: ON, OFF When the setting is ON, groove position information is sent to VCA host by using the labels BEVP, BEVM, and BEVC. *4. To set to ON, use the internal tracer unit with corresponding version software. Contact NIDEK or your authorized distributor for upgrading the tracer unit. 89

<Network 1 screen> Change settings on the Network screen if necessary. <Network 2 screen> Change settings on the Network screen if necessary. 90